Journal Article
Research Support, Non-U.S. Gov't
Add like
Add dislike
Add to saved papers

Refractive error after triple and non-simultaneous procedures: is the application of a standard constant keratometry value in IOL power calculation advisable?

PURPOSE: The purpose of this investigation was to determine whether or not the use of a standard constant keratometry value in cases of preoperative abnormal keratometry values in biometry for triple procedures is advisable.

METHODS: Cataract surgery and penetrating keratoplasty were performed in 82 eyes; 53 eyes underwent triple procedures and 29 eyes underwent non-simultaneous procedures. A standard constant keratometry value of 42.50 D was applied in 18 triple-procedure eyes because the preoperative measured keratometry values were outwith the normal range (41-47 D). The spherical equivalent and expected values were compared after a mean follow-up of 20.5 months.

RESULTS: Cases in the triple-procedure group that achieved spherical equivalent within +/- 2.0 D of expected values included nine of 18 eyes (50%) in which a standard constant keratometry value of 42.50 D was applied, three of 17 eyes (18%) in which keratometry values outwith the normal range were applied (p = 0.044), and eight of 18 eyes (45%) in which keratometry values within the normal range were applied (p = 0.862). Cases in the non-simultaneous procedure group that achieved spherical equivalent within +/- 2.0 D of expected values included 22 of 24 eyes (92%) in which keratometry values within the normal range were applied (p = 0.0025), and five of five eyes (100%) in which a standard constant keratometry value was applied.

CONCLUSIONS: The application of a standard constant keratometry value of 42.50 D for intraocular lens power calculation in triple procedures can be recommended if abnormal keratometry values were measured previously. If possible, non-simultaneous procedures should take priority.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app