CASE REPORTS
JOURNAL ARTICLE
Add like
Add dislike
Add to saved papers

Minimally invasive atrial fibrillation ablation combined with a new technique for thoracoscopic stapling of the left atrial appendage: case report.

BACKGROUND: Surgical therapy for atrial fibrillation (AF) is becoming increasingly popular in the concomitant setting. Minimally invasive techniques are being developed for management of the patient with stand-alone AF. We report on our first case of a patient undergoing thoracoscopic microwave epicardial AF ablation combined with the incorporation of a new device for left atrial appendage (LAA) exclusion.

METHODS: The patient is a 62-year-old man with a 10-year history of drug-resistant paroxysmal AF. He had failed multiple electrical cardioversions, as well as a percutaneous attempt at left and right superior pulmonary vein (PV) isolation. On October 8, 2003, he was admitted to undergo an off-pump thoracoscopic epicardial microwave ablation. While the patient was under general anesthesia, 3 thoracoscopic access ports were created in the right chest. The pericardium was widely opened. Red rubber catheters were positioned in the transverse and oblique sinuses. The 2 catheters were retrieved on the left side and tied together, forming a guide to the Flex 10 microwave ablation probe (Guidant Corporation, Fremont, CA, USA). The Flex 10 sheath was positioned to encircle all 4 pulmonary veins. The position of the ablation catheter was confirmed visually to be behind the LAA. Sequential ablation was then performed in the segments of the Flex 10 to create a continuous ablation line around the PVs. A connecting lesion to the base of the LAA was then performed. The LAA was then stapled using the SurgASSIST computer-mediated thoracoscopic stapling system (Power Medical Intervention, New Hope, PA, USA).

RESULTS: The procedure was uneventful and lasted for a total of 2.5 hours. The patient was discharged home on postoperative day 2 in rate-controlled AF. He was successfully electrically cardioverted to normal sinus rhythm (NSR). At latest follow-up he remained in NSR and continued to take dofetilide (Tikosyn).

CONCLUSION: Thoracoscopic epicardial microwave ablation of AF is a technically feasible procedure with minimal risk. The computer deployment and motion controlled stapling system that we used in this case has the potential to become a safe and reliable alternative to conventional stapling instruments.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app