Quantitation of film coating on Zantac 75 mg tablets and Epivir HBV 100 mg tablets by ICP-AES.

PURPOSE: To present a selective analytical Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES) method developed and validated for the quantitation of tablet film coatings containing titanium.

METHODS: Tablet samples were decomposed by either digestion or dry ashing. The amount of film tablet coating was calculated based on titanium content of the sample.

RESULTS: The reported ICP-AES method was accurate, precise, sensitive and linear for determination of titanium concentrations from 2.9 to 8.6 ppm.

CONCLUSION: This method provides an accurate determination of the amount of coating on a tablet and has general applicability for a variety of coating formulations containing different elements.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

Managing Alcohol Withdrawal Syndrome.Annals of Emergency Medicine 2024 March 26

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app