We have located links that may give you full text access.
EVALUATION STUDIES
JOURNAL ARTICLE
Catheter dysfunction and thrombosis of double-lumen hemodialysis catheters placed in the femoral vein.
Clinical Nephrology 2002 September
OBJECTIVE: Intraluminal thrombosis of the catheter was thought to be a major cause of catheter dysfunction. We evaluated if thrombi appear in the luminal side or outside of the catheters placed in the femoral vein in 21 hemodialysis patients.
METHODS: 23 double-lumen catheter (25 cm long and 4 mm diameter polyurethane) strippings were consecutively performed. Mean catheter dwell time was 17.9 +/- 11.2 days (2-45 days). The femoral vein was observed with ultrasound echography, and thrombo-venous ratio (thrombus diameter/vein diameter) was calculated. X-rays were also taken to clearly visualize the thrombi followed by contrast medium injection through the catheter.
RESULTS: Tube-shaped thrombi were echographically detected in 22 of 23 catheters (95.7%) when the catheter was stripped. Ten catheters (43.5%) were stripped due to the reduced blood flow, and tube-shaped thrombi were observed in the femoral vein, whereas no thrombus was found in the intraluminal side of the catheter. In 7 of 23 patients (30.4%) with leg edema on the same side of the catheter, the thrombovenous ratio was 78.9 +/- 7.4%, which was higher than that in the patients without leg edema (52.1 +/- 11.1%).
CONCLUSION: The tube-shaped thrombi, formed around the double-lumen catheter, may cause catheter dysfunction and reduced venous return of the lower legs. The catheter should be removed as soon as thrombosis is diagnosed, especially when accompanied by leg edema.
METHODS: 23 double-lumen catheter (25 cm long and 4 mm diameter polyurethane) strippings were consecutively performed. Mean catheter dwell time was 17.9 +/- 11.2 days (2-45 days). The femoral vein was observed with ultrasound echography, and thrombo-venous ratio (thrombus diameter/vein diameter) was calculated. X-rays were also taken to clearly visualize the thrombi followed by contrast medium injection through the catheter.
RESULTS: Tube-shaped thrombi were echographically detected in 22 of 23 catheters (95.7%) when the catheter was stripped. Ten catheters (43.5%) were stripped due to the reduced blood flow, and tube-shaped thrombi were observed in the femoral vein, whereas no thrombus was found in the intraluminal side of the catheter. In 7 of 23 patients (30.4%) with leg edema on the same side of the catheter, the thrombovenous ratio was 78.9 +/- 7.4%, which was higher than that in the patients without leg edema (52.1 +/- 11.1%).
CONCLUSION: The tube-shaped thrombi, formed around the double-lumen catheter, may cause catheter dysfunction and reduced venous return of the lower legs. The catheter should be removed as soon as thrombosis is diagnosed, especially when accompanied by leg edema.
Full text links
Related Resources
Trending Papers
Heart failure with preserved ejection fraction: diagnosis, risk assessment, and treatment.Clinical Research in Cardiology : Official Journal of the German Cardiac Society 2024 April 12
Proximal versus distal diuretics in congestive heart failure.Nephrology, Dialysis, Transplantation 2024 Februrary 30
Efficacy and safety of pharmacotherapy in chronic insomnia: A review of clinical guidelines and case reports.Mental Health Clinician 2023 October
World Health Organization and International Consensus Classification of eosinophilic disorders: 2024 update on diagnosis, risk stratification, and management.American Journal of Hematology 2024 March 30
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app
All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.
By using this service, you agree to our terms of use and privacy policy.
Your Privacy Choices
You can now claim free CME credits for this literature searchClaim now
Get seemless 1-tap access through your institution/university
For the best experience, use the Read mobile app