CLINICAL TRIAL
COMPARATIVE STUDY
JOURNAL ARTICLE
RANDOMIZED CONTROLLED TRIAL
RESEARCH SUPPORT, NON-U.S. GOV'T
Add like
Add dislike
Add to saved papers

Effect of intravenous versus epidural fentanyl on the minimum local analgesic concentration of epidural bupivacaine in labor.

Anesthesiology 2000 July
BACKGROUND: The minimum local analgesic concentration (MLAC) has been defined as the median effective local analgesic concentration (EC50) in a 20-ml volume for epidural analgesia in the first stage of labor. The aim of this study was to determine the relative local anesthetic sparing efficacies of intravenous and epidural fentanyl by comparison of their effects on the MLAC of bupivacaine.

METHODS: In this double-blind, randomized, prospective study, 84 parturients at < or = 7-cm cervical dilation who requested epidural analgesia were allocated to one of two groups. After lumbar epidural catheter placement, 20 ml bupivacaine (n = 44) or bupivacaine with 3 microg/ml (60 microg) fentanyl (n = 40) was administered. The plain bupivacaine group then received 60 microg intravenous fentanyl. The bupivacaine-fentanyl group received intravenous saline. The concentration of bupivacaine was determined by the response of the previous patient in that group to a higher or lower concentration using up-down sequential allocation. Analgesic efficacy was assessed using 100-mm visual analog pain scores, with < or = 10 mm within 30 min define as effective.

RESULTS: The MLAC of bupivacaine-intravenous fentanyl was 0.064% wt/vol (95% confidence interval, 0.049-0.080), and the MLAC of bupivacaine-epidural fentanyl was 0.034% wt/vol (95% confidence interval, 0.017-0.050). Epidural fentanyl significantly increased the analgesic potency of bupivacaine by a factor of 1.88 (95% confidence interval, 1.09-3.67) compared with intravenous fentanyl. The epidural fentanyl group demonstrated significantly higher dermatomal spread (P = 0.0064) and increased pruritus (P = 0. 01).

CONCLUSIONS: Epidural fentanyl significantly reduced the MLAC of bupivacaine when compared with intravenous fentanyl for the parturients in this study. The significantly enhanced local anesthetic sparing, dermatomal level, and pruritus with epidural fentanyl suggest a primarily spinal site of action.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app