Measurement of low breath-alcohol concentrations: laboratory studies and field experience.

Recent federal rules and traffic law changes impose breath-alcohol thresholds of 0.02 and 0.04 g/210 L upon some classes of motor vehicle operators, such as juveniles and commercial vehicle operators. In federally regulated alcohol testing in the workplace, removal of covered workers from safety-sensitive duties, and other adverse actions, also occur at breath-alcohol concentrations (BrACs) of 0.02 and 0.04 g/210 L. We therefore studied performance of vapor-alcohol and breath-alcohol measurement at low alcohol concentrations in the laboratory and in the field, with current-generation evidential analyzers. We report here chiefly our field experience with evidential breath-alcohol testing of drinking drivers on paired breath samples using 62 Intoxilyzer 5000-D analyzers, for BrACs of 0-0.059 g/210 L. The data from 62 law enforcement breath-alcohol testing sites were collected and pooled, with BrACs recorded to three decimal places, and otherwise carried out under the standard Oklahoma evidential breath-alcohol testing protocol. For 2105 pooled simulator control tests at 0.06-0.13 g/210 L the mean +/- SD of the differences between target and result were -0.001 +/- 0.0035 g/210 L and 0.003 +/- 0.0023 g/210 L for signed and absolute differences, respectively (spans -0.016-0.010, 0.000-0.016). For 2078 paired duplicate breath-alcohol measurements with the Intoxilyzer 5000-D, the mean +/- SD difference (BrAC1-BrAC2) were 0.002 +/- 0.0026 (span 0-0.020 g/210 L). Variability of breath-alcohol measurements was related inversely to the alcohol concentration. Ninety-nine percent prediction limits for paired BrAC measurements correspond to a 0.020 g/210 L maximum absolute difference, meeting the NSC/CAOD recommendation that paired breath-alcohol analysis results within 0.02 g/210 L shall be deemed to be in acceptable agreement. We conclude that the field system for breath-alcohol analysis studied by us can and does perform reliably and accurately at low BrACs.

Full text links

We have located links that may give you full text access.
Can't access the paper?
Try logging in through your university/institutional subscription. For a smoother one-click institutional access experience, please use our mobile app.

Related Resources

For the best experience, use the Read mobile app

Mobile app image

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app

All material on this website is protected by copyright, Copyright © 1994-2024 by WebMD LLC.
This website also contains material copyrighted by 3rd parties.

By using this service, you agree to our terms of use and privacy policy.

Your Privacy Choices Toggle icon

You can now claim free CME credits for this literature searchClaim now

Get seemless 1-tap access through your institution/university

For the best experience, use the Read mobile app