keyword
MENU ▼
Read by QxMD icon Read
search

Circulatory assist device

keyword
https://www.readbyqxmd.com/read/29164425/outflow-graft-anastomosis-site-design-could-be-correlated-to-aortic-valve-regurgitation-under-left-ventricular-assist-device-support
#1
Kei Iizuka, Tomohiro Nishinaka, Yuki Ichihara, Takuma Miyamoto, Kenji Yamazaki
Aortic valve regurgitation (AR) is a critical complication during circulatory support with a left ventricular assist device (LVAD). The time-course of AR and related factors, including outflow graft anastomosis site design, were investigated. Twenty-three patients who had continuous-flow LVAD implantation and were supported for more than 6 months were investigated. AR grade (none, 0; trivial, 0.5; mild, 1; mild-moderate, 1.5; moderate, 2; moderate-severe, 2.5; severe, 3) and aortic valve opening were evaluated with echocardiography...
November 21, 2017: Journal of Artificial Organs: the Official Journal of the Japanese Society for Artificial Organs
https://www.readbyqxmd.com/read/29156019/the-aspartate-transaminase-alanine-transaminase-deritis-ratio-predicts-mid-term-mortality-and-renal-and-respiratory-dysfunction-after-left-ventricular-assist-device-implantation
#2
Kevin Pilarczyk, Henning Carstens, Jens Heckmann, Ali Canbay, Achim Koch, Nikolaus Pizanis, Heinz Jakob, Markus Kamler
OBJECTIVES: Preoperative liver dysfunction is a well-known risk factor for adverse events after major surgery. However, there is only little data regarding the precise role of the Model of End-Stage Liver Disease (MELD) score and the De Ritis ratio (DRR, alanine transaminase/aspartate aminotransferase) as a predictor for outcome after left ventricular assist device (LVAD) implantation. METHODS: A retrospective analysis of all patients undergoing LVAD implantation at our institution between January 2012 and August 2014 was performed...
October 1, 2017: European Journal of Cardio-thoracic Surgery
https://www.readbyqxmd.com/read/29153637/quality-of-life-and-functional-capacity-outcomes-in-the-momentum-3-trial-at-6-months-a-call-for-new-metrics-for-left-ventricular-assist-device-patients
#3
Jennifer A Cowger, Yoshifumi Naka, Keith D Aaronson, Douglas Horstmanshof, Sanjeev Gulati, Debbie Rinde-Hoffman, Sean Pinney, Sirtaz Adatya, David J Farrar, Ulrich P Jorde
BACKGROUND: The Multicenter Study of MAGLEV Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3 (MOMENTUM 3) clinical trial demonstrated improved 6-month event-free survival, but a detailed analysis of health-related quality of life (HR-QOL) and functional capacity (FC) was not presented. Further, the effect of early serious adverse events (SAEs) on these metrics and on the general ability to live well while supported with a left ventricular assist system (LVAS) warrants evaluation...
October 24, 2017: Journal of Heart and Lung Transplantation
https://www.readbyqxmd.com/read/29153214/-psychological-support-for-patients-with-a-ventricular-assist-device
#4
Laurence Le Helias
In the case of end-stage heart failure, the medical-surgical team can suggest the use of an external circulatory assist device as a definitive therapy. Living with this assistance requires a certain amount of adaptation on the part of the patients and their family, but can significantly improve quality of life. Support groups give them the opportunity to talk about their new life and receive psychological support.
November 2017: Soins; la Revue de Référence Infirmière
https://www.readbyqxmd.com/read/29153213/-circulatory-assistance-an-alternative-to-heart-transplantation
#5
Jean-Christian Roussel, Thomas Sénage
Circulatory assistance is developing as a treatment for patients with end-stage heart failure. There are two alternative devices: a univentricular circulatory assist pump, or a total artificial heart. It is used to bridge the time to transplantation and, increasingly, as a definitive alternative to a heart transplant.
November 2017: Soins; la Revue de Référence Infirmière
https://www.readbyqxmd.com/read/29150326/concomitant-mitral-valve-procedures-in-patients-undergoing-implantation-of-continuous-flow-left-ventricular-assist-devices-an-intermacs-database-analysis
#6
Jason O Robertson, David C Naftel, Susan L Myers, Ryan J Tedford, Susan M Joseph, James K Kirklin, Scott C Silvestry
BACKGROUND: Management of existing mitral valve (MV) disease in patients undergoing left ventricular assist device (LVAD) implantation remains controversial. METHODS: Among continuous-flow LVAD patients with moderate to severe mitral regurgitation entered into the Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) database between April 2008 and March 2014 (n = 4,930), outcomes were compared between patients who underwent MV repair (MVr, n = 252), MV replacement (MVR, n = 11) and no MV procedure (no MVP, n = 4,667)...
October 10, 2017: Journal of Heart and Lung Transplantation
https://www.readbyqxmd.com/read/29146417/association-between-percutaneous-hemodynamic-support-device-and-survival-from-cardiac-arrest-in-the-state-of-michigan
#7
Andrew Pressman, Kelly N Sawyer, William Devlin, Robert Swor
INTRODUCTION: The role of circulatory support in the post-cardiac arrest period remains controversial. Our objective was to investigate the association between treatment with a percutaneous hemodynamic support device and outcome after admission for cardiac arrest. METHODS: We performed a retrospective study of adult patients with admission diagnosis of cardiac arrest or ventricular fibrillation (VF) from the Michigan Inpatient Database, treated between July 1, 2010, and June 30, 2013...
October 17, 2017: American Journal of Emergency Medicine
https://www.readbyqxmd.com/read/29141690/resternotomy-does-not-adversely-affect-outcome-after-left-ventricular-assist-device-implantation
#8
Maria Papathanasiou, Loukas Tsourelis, Nikolaus Pizanis, Achim Koch, Markus Kamler, Tienush Rassaf, Peter Luedike
BACKGROUND: Resternotomy in cardiac surgery is considered a risk factor for postoperative complications. Previous studies have demonstrated an ambiguous relationship between resternotomy and clinical outcomes. Registry data from a mixed population of durable circulatory support devices suggest that history of cardiac surgery is a risk factor for mortality. Our study investigates the prognostic significance of resternotomy in a homogenous cohort of left ventricular assist device (LVAD) recipients...
November 15, 2017: European Journal of Medical Research
https://www.readbyqxmd.com/read/29140423/ventricular-assist-device-implantation-in-a-young-patient-with-non-compaction-cardiomyopathy-and-hereditary-spherocytosis
#9
Katharina Huenges, Bernd Panholzer, Jochen Cremer, Assad Haneya
A case of a 15-year-old female patient with acute heart failure due to non-compaction cardiomyopathy and hereditary anaemia (hereditary spherocytic elliptocytosis) requiring ventricular assist device implantation as a bridge to transplantation is presented. The possible effects of mechanical stress on erythrocytes potentially induced by mechanical circulatory support remains unclear, but it may lead to haemolytic crisis in patients suffering from hereditary anaemia. In our case, ventricular assist device therapy was feasible, and haematological complications did not occur within 6 weeks of bridging our patient to heart transplantation...
November 10, 2017: European Journal of Cardio-thoracic Surgery
https://www.readbyqxmd.com/read/29129374/the-jarvik-2000-left-ventricular-assist-device-as-a-bridge-to-transplantation-japanese-registry-for-mechanically-assisted-circulatory-support
#10
Hiroki Kohno, Goro Matsumiya, Yoshiki Sawa, Minoru Ono, Yoshikatsu Saiki, Akira Shiose, Kenji Yamazaki, Yoshiro Matsui, Hiroshi Niinami, Hikaru Matsuda, Soichiro Kitamura, Takeshi Nakatani, Shunei Kyo
BACKGROUND: The Jarvik 2000 ventricular assist device features a miniaturized intraventricular pump and an intermittent low-speed function that facilitates aortic valve opening. Despite its long history, little is known about the Jarvik device with regard to post-implantation outcomes. METHODS: Prospectively collected data from 13 participating hospitals were extracted from the Japanese Registry for Mechanically Assisted Circulatory Support database to analyze mortality, morbidity and de-novo aortic regurgitation...
October 24, 2017: Journal of Heart and Lung Transplantation
https://www.readbyqxmd.com/read/29117042/impact-of-patient-distance-from-ventricular-assist-device-implanting-center-on-short-and-long-term-outcomes
#11
Ashwin K Ravichandran, Palak Shah, Ramesh Singh, Keith D Aaronson, Francis D Pagani, John Stulak, Shannon M Dunlay, Todd F Dardas, Nahush A Mokadam, Christopher T Salerno, Jennifer A Cowger
Highly specialized left ventricular assist device care is not readily available in many areas, potentially limiting access to therapy. This retrospective analysis examines the relationship of outcomes by patient distance from implanting left ventricular assist device center within the Mechanical Circulatory Support Research Network. Zip codes were used to calculate patient distance, with the primary outcome of interest being 3-year survival by distance from the surgical center. Secondary outcomes included 90-day survival and incident event rates for the following: gastrointestinal bleeding, infection, cerebral event, and pump thrombosis...
November 7, 2017: ASAIO Journal: a Peer-reviewed Journal of the American Society for Artificial Internal Organs
https://www.readbyqxmd.com/read/29117039/optimization-of-axial-pump-characteristic-dimensions-and-induced-hemolysis-for-mechanical-circulatory-support-devices
#12
Theodosios Korakianitis, Mohammad A Rezaienia, Gordon M Paul, Eldad J Avital, Martin T Rothman, Sahand Mozafari
The application of axial pumps as ventricular assist devices (VADs) requires significant modifications to the size and characteristics of industrial pumps due to the difference in flow fields of industrial and medical pumps. Industrial pumps operate in the region of Reynolds number Re = 108, whereas axial blood pumps operate in Re < 10. The common pump design technique is to rely on the performance of previously designed pumps using the concept of fluid dynamic similarity. Such data are available for industrial pumps as specific speed-specific diameter (ns-ds) graphs...
November 7, 2017: ASAIO Journal: a Peer-reviewed Journal of the American Society for Artificial Internal Organs
https://www.readbyqxmd.com/read/29112104/cardiogenic-shock-due-to-end-stage-heart-failure-and-acute-myocardial-infarction-characteristics-and-outcome-of-temporary-mechanical-circulatory-support
#13
Hoong Sern Lim, Neil Howell
BACKGROUND: Mechanical circulatory support (MCS) is increasingly used in cardiogenic shock, but outcomes may differ between patients with acute myocardial infarction (AMI) or end-stage heart failure (ESHF). This study aimed to describe the characteristics of patients with cardiogenic shock due to AMI and ESHF. METHODS: Single centre study of consecutive patients with cardiogenic shock due to AMI (n = 26) and ESHF (n = 42) who underwent MCS (extracorporeal life support, Impella or temporary ventricular assist devices)...
November 3, 2017: Shock
https://www.readbyqxmd.com/read/29110794/anesthetic-management-of-the-patient-with-a-ventricular-assist-device
#14
REVIEW
Marie-Louise Meng, Jessica Spellman
The use of long- and short-term mechanical circulatory support in the form of ventricular assist device (VAD) has increased over the last decade. Although cardiothoracic anesthesiologists care for these patients during device placement, increasingly higher numbers of general anesthesiologists are involved in the management of VAD patients during noncardiac surgery and procedures. An understanding of devices, their indications, and complications is essential to the anesthesiologists caring for these patients...
June 2017: Best Practice & Research. Clinical Anaesthesiology
https://www.readbyqxmd.com/read/29107545/infectious-complications-of-ventricular-assist-device-use-in-children-in-the-united-states-data-from-the-pediatric-interagency-registry-for-mechanical-circulatory-support-pedimacs
#15
Scott R Auerbach, Marc E Richmond, Kurt R Schumacher, Dalia Lopez-Colon, Max B Mitchell, Mark W Turrentine, Ryan S Cantor, Robert A Niebler, Pirooz Eghtesady
BACKGROUND: Infections are frequent in pediatric ventricular assist device (VAD) patients. In this study we aimed to describe infections in durable VAD patients reported to Pedimacs. METHODS: Durable VAD data from the Pedimacs registry (September 19, 2012 to December 31, 2015) were analyzed. Infections were described with standard descriptive statistics, Kaplan-Meier analysis and competing outcomes analysis. RESULTS: There were 248 implants in 222 patients, with a mean age and a median follow-up of 11 ± 6...
October 3, 2017: Journal of Heart and Lung Transplantation
https://www.readbyqxmd.com/read/29106559/outcome-of-heart-transplantation-after-bridge-to-transplant-strategy-using-various-mechanical-circulatory-support-devices
#16
Daisuke Yoshioka, Boyangzi Li, Hiroo Takayama, Reshad A Garan, Veli K Topkara, Jiho Han, Paul Kurlansky, Melana Yuzefpolskaya, Paolo C Colombo, Yoshifumi Naka, Koji Takeda
OBJECTIVES: Orthotopic heart transplantation (OHT) is limited by a chronic shortage of donors. With the evolution of technology, more patients have been bridged to transplant (BTT) through various pathways using various types of mechanical circulatory support. We compared short- and long-term outcomes among these various strategies of BTT. METHODS: We retrospectively reviewed 410 patients who had OHT between January 2009 and April 2015. Patients were divided into 4 groups according to BTT status: primary OHT without bridging (Group A, n  = 246); bridge with implantable continuous-flow left ventricular assist device (CF-LVAD) (Group B, n  = 130); bridge with short-term mechanical circulatory support (Group C, n  = 16) and bridge with multiple mechanical circulatory supports, including short-term mechanical circulatory support and CF-LVAD (Group D, n  = 18)...
July 4, 2017: Interactive Cardiovascular and Thoracic Surgery
https://www.readbyqxmd.com/read/29095733/left-lateral-thoracotomy-for-centrifugal-continuous-flow-left-ventricular-assist-device-placement-an-analysis-from-the-mechanical-circulatory-support-research-network
#17
Simon Maltais, Lucman A Anwer, Vakhtang Tchantchaleishvili, Nicholas A Haglund, Shannon M Dunlay, Keith D Aaronson, Francis D Pagani, Jennifer Cowger, Christopher T Salerno, Palak Shah, Zain Khalpey, Jan Schmitto, John M Stulak
Continuous-flow left ventricular assist devices (CF-LVADs) have revolutionized the management of patients with advanced heart failure. Alternative implant strategies are increasingly used for device placement. We reviewed our experience from the Mechanical Circulatory Support Research Network registry with the HeartWare centrifugal CF-LVAD (HVAD). From May 2004 to August 2015, 1,150 patients underwent primary CF-LVAD implantation at our institutions. Within this group, a total of 283 patients (25%) were implanted with the HVAD...
October 31, 2017: ASAIO Journal: a Peer-reviewed Journal of the American Society for Artificial Internal Organs
https://www.readbyqxmd.com/read/29094607/predictors-of-survival-and-ability-to-wean-from-short-term-mechanical-circulatory-support-device-following-acute-myocardial-infarction-complicated-by-cardiogenic-shock
#18
A Reshad Garan, Christina Eckhardt, Koji Takeda, Veli K Topkara, Kevin Clerkin, Justin Fried, Amirali Masoumi, Ryan T Demmer, Pauline Trinh, Melana Yuzefpolskaya, Yoshifumi Naka, Dan Burkhoff, Ajay Kirtane, Paolo C Colombo, Hiroo Takayama
BACKGROUND: Cardiogenic shock following acute myocardial infarction (AMI-CS) portends a poor prognosis. Short-term mechanical circulatory support devices (MCSDs) provide hemodynamic support for patients with cardiogenic shock but predictors of survival and the ability to wean from short-term MCSDs remain largely unknown. METHODS: All patients > 18 years old treated at our institution with extra-corporeal membrane oxygenation or short-term surgical ventricular assist device for AMI-CS were studied...
November 1, 2017: European Heart Journal. Acute Cardiovascular Care
https://www.readbyqxmd.com/read/29094485/clinical-and-histopathological-effects-of-heart-failure-drug-therapy-in-advanced-heart-failure-patients-on-chronic-mechanical-circulatory-support
#19
Anna B Catino, Peter Ferrin, James Wever-Pinzon, Benjamin D Horne, Omar Wever-Pinzon, Abdallah G Kfoury, Lauren McCreath, Nikolaos A Diakos, Stephen McKellar, Antigone Koliopoulou, Michael J Bonios, Mohammad Al-Sarie, Iosif Taleb, Elizabeth Dranow, James C Fang, Stavros G Drakos
AIMS: Adjuvant heart failure (HF) drug therapy in patients undergoing chronic mechanical circulatory support (MCS) is often used in conjunction with a continuous-flow left ventricular assist device (LVAD), but its potential impact is not well defined. The objective of the present study was to examine the effects of conventional HF drug therapy on myocardial structure and function, peripheral organ function and the incidence of adverse events in the setting of MCS. METHODS AND RESULTS: Patients with chronic HF requiring LVAD support were prospectively enrolled...
November 1, 2017: European Journal of Heart Failure
https://www.readbyqxmd.com/read/29094038/intracorporeal-heat-distribution-from-fully-implantable-energy-sources-for-mechanical-circulatory-support-a-computational-proof-of-concept-study
#20
Jacopo Biasetti, Aliaksei Pustavoitau, Pier Giorgio Spazzini
Mechanical circulatory support devices, such as total artificial hearts and left ventricular assist devices, rely on external energy sources for their continuous operation. Clinically approved power supplies rely on percutaneous cables connecting an external energy source to the implanted device with the associated risk of infections. One alternative, investigated in the 70s and 80s, employs a fully implanted nuclear power source. The heat generated by the nuclear decay can be converted into electricity to power circulatory support devices...
2017: Frontiers in Bioengineering and Biotechnology
keyword
keyword
98496
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"