keyword
https://read.qxmd.com/read/34916383/dosimetric-validation-of-acuros%C3%A2-xb-algorithm-for-rapidarc%C3%A2-treatment-technique-a-post-software-upgrade-analysis
#21
JOURNAL ARTICLE
Lalit Kumar, Manindra Bhushan, Vimal Kishore, Girigesh Yadav, Om Prakash Gurjar
AIM: To validate the Acuros® XB (AXB) algorithm in Eclipse treatment planning system (TPS) for RapidArc™ (RA) technique following the software upgrades. MATERIALS AND METHODS: A Clinac-iX (2300CD) linear accelerator and Eclipse TPS (Varian Medical System, Inc., Palo Alto, USA) was used for commissioning of AXB algorithm using a 6 megavolts photon beam. Percentage depth dose (PDD) and profiles for field size 2 cm × 2 cm, 4 cm × 4 cm, 6 cm × 6 cm, 10 cm × 10 cm, 20 cm × 20 cm, 30 cm × 30 cm to 40 cm × 40 cm were taken...
October 2021: Journal of Cancer Research and Therapeutics
https://read.qxmd.com/read/34740518/dosimetric-comparison-and-validation-of-eclipse-anisotropic-analytical-algorithm-aaa-and-acurosxb-axb-algorithms-in-rapidarc-based-radiosurgery-plans-of-patients-with-solitary-brain-metastasis
#22
JOURNAL ARTICLE
Sharika Venugopal Menon, Raghukumar P, Saju Bhasi, Zhenia Gopalakrishnan, Sarin B, Shilpa K, Raghuram K Nair
Stereotactic radiosurgery (SRS) is increasingly being used to manage solitary or multiple brain metastasis. This study aims to compare and validate Anisotropic Analytical Algorithm (AAA) and AcurosXB (AXB) algorithms of Eclipse Treatment Planning System (TPS) in RapidArc-based SRS plans of patients with solitary brain metastasis. Twenty patients with solitary brain metastasis who have been already treated with RapidArc SRS plans calculated using AAA plans were selected for this study. These plans were recalculated using AXB algorithm keeping the same arc orientations, multi-leaf collimator apertures, and monitor units...
April 2022: Medical Dosimetry: Official Journal of the American Association of Medical Dosimetrists
https://read.qxmd.com/read/34702859/the-new-srs-fsrt-technique-hyperarc-for-benign-brain-lesions-a-dosimetric-analysis
#23
JOURNAL ARTICLE
Hsiu-Wen Ho, Ching-Chieh Yang, Hsiu-Man Lin, Hsiao-Yun Chen, Chun-Chiao Huang, Shih-Chang Wang, Yu-Wei Lin
To evaluate the potential benefit of HyperArc (HA) fractionated stereotactic radiotherapy (FSRT) for the benign brain lesion. Sixteen patients with a single deep-seated, centrally located benign brain lesion treated by CyberKnife (CK, G4 cone-based model) were enrolled. Treatment plans for HA with two different optimization algorithms (SRS NTO and ALDO) and coplanar RapidArc (RA) were generated for each patient to meet the corresponding treatment plan criteria. These four FSRT treatment plans were divided into two groups-the homogeneous delivery group (HA-SRS NTO and coplanar RA) and the inhomogeneous delivery group (HA-ALDO and cone-based CK)-to compare for dosimetric outcomes...
October 26, 2021: Scientific Reports
https://read.qxmd.com/read/34596491/volumetric-modulated-arc-therapy-versus-intensity-modulated-proton-therapy-in-the-irradiation-of-infra-diaphragmatic-hodgkin-lymphoma-in-female-patients
#24
JOURNAL ARTICLE
Johannes Rosenbrock, Christian Baues, Andres Vasquez-Torres, Alessandro Clivio, Antonella Fogliata, Peter Borchmann, Simone Marnitz, Luca Cozzi
PURPOSE: To investigate the role of infra diaphragmatic intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT) for female Hodgkin Lymphoma (HL) patients and to estimate the risk of secondary cancer and ovarian failure. METHODS: A comparative treatment planning study was performed on 14 patients, and the results were compared according to conventional dose-volume metrics. In addition, estimates of the excess absolute risk (EAR) of secondary cancer induction were determined for the bowel, the bladder and the rectum...
October 1, 2021: Acta Oncologica
https://read.qxmd.com/read/34532425/risk-factors-for-radiation-induced-lymphopenia-in-patients-with-breast-cancer-receiving-adjuvant-radiotherapy
#25
JOURNAL ARTICLE
Fang Chen, Hao Yu, Hong Zhang, Yaqing Nong, Qian Wang, Haiman Jing, Ying Han, Junjie Wu, Zheng Zhou, Li Yang, Zhiyuan Xu, Yaya Liu, Pingfu Fu, Jian-Yue Jin, Victor Hsue, Amy Chang, Feng-Ming Spring Kong
BACKGROUND: This study aimed to investigate radiation-induced lymphopenia and its potential risk factors in patients with breast cancer receiving adjuvant radiotherapy. METHODS: Breast cancer patients received adjuvant radiotherapy (RT) at our hospital with peripheral lymphocyte counts (PLC) at pre-and immediately after RT (post-RT) were eligible. The primary endpoints were any grade of lymphopenia post-RT and nadir-PLC/pre-PLC <0.8. Patient characteristics, tumor factors, and treatment factors were collected for risk assessment...
August 2021: Annals of Translational Medicine
https://read.qxmd.com/read/34434574/dosimetric-impact-of-acuros-xb-on-cervix-radiotherapy-using-rapidarc-technique-a-dosimetric-study
#26
JOURNAL ARTICLE
Lalit Kumar, Vimal Kishore, Manindra Bhushan, Pawan Kumar, Rahul Lal Chaudhary
BACKGROUND: Acuros XB (AXB) may predict better rectal toxicities and treatment outcomes in cervix carcinoma. The aim of the study was to quantify the potential impact of AXB computations on the cervix radiotherapy using the RapidArc (RA ) technique as compared to anisotropic analytical algorithm (AA) computations. MATERIALS AND METHODS: A cohort of 30 patients previously cared for cervix carcinoma (stages II-IIIB) was selected for the present analysis. The RA plans were computed using AA and AXB dose computation engines under identical beam setup and MLC pattern...
2021: Reports of Practical Oncology and Radiotherapy
https://read.qxmd.com/read/34257570/imat-igrt-treatment-with-simultaneous-integrated-boost-as-dose-escalation-for-patients-with-cervical-cancer-a-single-institution-prospective-pilot-study
#27
JOURNAL ARTICLE
Zoltán Lőcsei, Klára Sebestyén, Zsolt Sebestyén, Eszter Fehér, Dorottya Soltész, Zoltán Musch, László Csaba Mangel
Purpose: The aim of this study was to introduce the simultaneous integrated boost (SIB) technique to assess the safety of replacement of the brachytherapy (BT) boost for ineligible patients with cervical cancer receiving radiochemotherapy (RCT). Methods: Fourteen patients were enrolled between 2015 and 2018. SIB was delivered using RapidArc technique at doses of 2.4 Gy per fraction during pelvic irradiation with 50.4/1.8 Gy in seven patients (to a total dose of 67.2 Gy) with limited volume disease...
2021: Pathology Oncology Research: POR
https://read.qxmd.com/read/34127013/a-novel-external-beam-radiotherapy-method-for-cervical-cancer-patients-using-virtual-straight-or-bending-boost-areas-an-in-silico-feasibility-study
#28
JOURNAL ARTICLE
Luca Cozzi, Sushil Beriwal, Esa Kuusela, Supriya Chopra, Hester Burger, Nanette Joubert, Antonella Fogliata, Jai Prakash Agarwal, Pat Kupelian
AIM: To investigate the potential role of a novel spatially fractionated radiation therapy (SFRT) method where heterogeneous dose patterns are created in target areas with virtual rods, straight or curving, of variable position, diameter, separation and alignment personalised to a patient's anatomy. The images chosen for this study were CT scans acquired for the external beam part of radiotherapy. METHODS: Ten patients with locally advanced cervical cancer were retrospectively investigated with SFRT...
June 14, 2021: Radiation Oncology
https://read.qxmd.com/read/33730113/-dosimetric-analysis-of-linac-based-stereotactic-irradiation-of-brain-tumours-in-cirs-shane-phantom
#29
JOURNAL ARTICLE
Dalma Mihály, Barbara Melles-Bencsik, Tamás Pócza, Gábor Kontra, Tibor Major, András Bajcsay, Csaba Polgár, Csilla Pesznyák
The aim of the study was to compare the different stereotactic treatment plans and dose calculation algorithms for small targets with film dosimetry in anthropomorphic phantom. Treatment plans were prepared for multiple targets with single setup isocenter. Plans for three different irradiation techniques were generated using conformal arc with four non-coplanar arcs, RapidArc with two coplanar full arcs and RapidArc with four non-coplanar arcs in the Varian Eclipse v13.7.16 TPS. Conformal arc and RapidArc plans were calculated using AAA, Acuros XBDm and XBDw algorithms...
March 17, 2021: Magyar Onkologia
https://read.qxmd.com/read/33287650/the-potential-role-of-intensity-modulated-proton-therapy-in-hepatic-carcinoma-in-mitigating-the-risk-of-dose-de-escalation
#30
JOURNAL ARTICLE
Luca Cozzi, Tiziana Comito, Mauro Loi, Antonella Fogliata, Ciro Franzese, Davide Franceschini, Elena Clerici, Giacomo Reggiori, Stefano Tomatis, Marta Scorsetti
PURPOSE: To investigate the role of intensity-modulated proton therapy (IMPT) for hepatocellular carcinoma (HCC) patients to be treated with stereotactic body radiation therapy (SBRT) in a risk-adapted dose prescription regimen. METHODS: A cohort of 30 patients was retrospectively selected as "at-risk" of dose de-escalation due to the proximity of the target volumes to dose-limiting healthy structures. IMPT plans were compared to volumetric modulated arc therapy (VMAT) RapidArc (RA) plans...
January 2020: Technology in Cancer Research & Treatment
https://read.qxmd.com/read/33153875/dosimetric-impact-of-switching-from-aaa-to-acuros-dose-to-water-and-dose-to-medium-for-rapidarc-plans-of-nasopharyngeal-carcinomas
#31
COMPARATIVE STUDY
R Sayah, T Felefly, L Zouein, J El Barouky, N Khater, N Farah, C Roukoz, C El Khoury, F Azoury, D Nehme Nasr, E Nasr
PURPOSE: This work aims to evaluate the dosimetric consequences of replacing the Anisotropic Analytical Algorithm (AAA) by Acuros XB (AXB), dose-to-water (Dw) or dose-to-medium (Dm), for RapidArc plans of nasopharyngeal carcinomas (NPC). MATERIALS AND METHODS: Seventeen NPC plans created with AAA (v15.6) were recalculated with AXB (v15.6) Dw and Dm. The dose-volume parameters to the planning target volumes (PTV) and relevant organs at risk (OAR) were compared. The high dose PTV was divided into bone, air and tissue components and the comparison was performed for each of them...
December 2020: Cancer Radiothérapie: Journal de la Société Française de Radiothérapie Oncologique
https://read.qxmd.com/read/33089021/interinstitutional-plan-quality-assessment-of-2-linac-based-single-isocenter-multiple-metastasis-radiosurgery-techniques
#32
JOURNAL ARTICLE
Haisong Liu, Evan M Thomas, Jun Li, Yan Yu, David Andrews, James M Markert, John B Fiveash, Wenyin Shi, Richard A Popple
Purpose: Interest and application of stereotactic radiosurgery for multiple brain metastases continue to increase. Various planning systems are available for linear accelerator (linac)-based single-isocenter multiple metastasis radiosurgery. Two of the most advanced systems are BrainLAB Multiple Metastases Elements (MME), a dynamic conformal arc (DCA) approach, and Varian RapidArc (RA), a volumetric modulated arc therapy (VMAT) approach. In this work, we systematically compared plan quality between the 2 techniques...
September 2020: Advances in Radiation Oncology
https://read.qxmd.com/read/32727407/assessment-of-the-results-and-hematological-side-effects-of-3d-conformal-and-imrt-arc-therapies-delivered-during-craniospinal-irradiation-of-childhood-tumors-with-a-follow-up-period-of-five-years
#33
JOURNAL ARTICLE
Zoltán Lőcsei, Róbert Farkas, Kornélia Borbásné Farkas, Klára Sebestyén, Zsolt Sebestyén, Zoltán Musch, Ágnes Vojcek, Noémi Benedek, László Mangel, Gábor Ottóffy
BACKGROUND: Craniospinal irradiation (CSI) of childhood tumors with the RapidArc technique is a new method of treatment. Our objective was to compare the acute hematological toxicity pattern during 3D conformal radiotherapy with the application of the novel technique. METHODS: Data from patients treated between 2007 and 2014 were collected, and seven patients were identified in both treatment groups. After establishing a general linear model, acute blood toxicity results were obtained using SPSS software...
July 29, 2020: BMC Cancer
https://read.qxmd.com/read/32676685/the-role-of-a-knowledge-based-dose-volume-histogram-predictive-model-in-the-optimisation-of-intensity-modulated-proton-plans-for-hepatocellular-carcinoma-patients-training-and-validation-of-a-novel-commercial-system
#34
JOURNAL ARTICLE
Luca Cozzi, Reynald Vanderstraeten, Antonella Fogliata, Feng-Ling Chang, Po-Ming Wang
PURPOSE: To investigate the performance of a knowledge-based RapidPlan, for optimisation of intensity-modulated proton therapy (IMPT) plans applied to hepatocellular cancer (HCC) patients. METHODS: A cohort of 65 patients was retrospectively selected: 50 were used to "train" the model, while the remaining 15 provided independent validation. The performance of the RapidPlan model was benchmarked against manual optimisation and was also compared to volumetric modulated arc therapy (RapidArc) photon plans...
July 16, 2020: Strahlentherapie und Onkologie: Organ der Deutschen Röntgengesellschaft ... [et Al]
https://read.qxmd.com/read/32659502/arc-welding-noise-assessment-from-the-measured-ultrasound-pressure-levels-part-iii-modern-welding-techniques
#35
JOURNAL ARTICLE
Piotr Szłapa, Wojciech Marczak
The new method of the assessment of total sound pressure levels and their A-weighting-filtered counterparts from the sound pressure levels in a selected high-frequency band, reported in previous papers from this series, was tested for four modern techniques of welding: RapidArc, CMT, AC Pulse, and Cold Arc. The measurement results for 113 welding runs were divided into two groups. These in the first group served as data for calculations of the correlation equations for the sound pressure levels, while the others were applied as control ones...
July 2, 2020: Ultrasonics
https://read.qxmd.com/read/32641082/dosimetric-comparison-between-rapidarc-and-hyperarc-techniques-in-salvage-stereotactic-body-radiation-therapy-for-recurrent-nasopharyngeal-carcinoma
#36
COMPARATIVE STUDY
Hsiu-Wen Ho, Steve P Lee, Hisu-Man Lin, Hsiao-Yun Chen, Chun-Chiao Huang, Shih-Chang Wang, Ching-Chieh Yang, Yu-Wei Lin
BACKGROUND: To evaluate dosimetric differences of salvage irradiations using two commercially available volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) techniques: RapidArc (RA) and HyperArc (HA), for recurrent nasopharyngeal carcinoma (NPC) after initial radiation therapy. METHODS: Ten patients with recurrent NPC status previously treated with radiation therapy were considered suitable candidates for salvage SBRT using VMAT approach...
July 8, 2020: Radiation Oncology
https://read.qxmd.com/read/32532351/clinical-implication-in-the-use-of-the-aaa-algorithm-versus-the-axb-in-nasopharyngeal-carcinomas-by-comparison-of-tcp-and-ntcp-values
#37
COMPARATIVE STUDY
Antonella Bufacchi, Orietta Caspiani, Giulia Rambaldi, Luca Marmiroli, Giuseppe Giovinazzo, Mattia Polsoni
PURPOSE: Retrospective analysis of volumetric modulated arc therapy treatment plans to investigate qualitative, possible, clinical consequences of the use of AAA versus AXB in nasopharyngeal cancer (NPC) cases. METHODS: The dose distribution of 26 treatment plans, produced using RapidArc technique and AAA algorithm, were recalculated using AXB and the same number of monitor units provided by AAA and clinically delivered to each patient. The potential clinical effect of dosimetric differences in the planning target volume (PTV) and in organs at risk (OAR) were evaluated by comparing TCP and NTCP values...
June 12, 2020: Radiation Oncology
https://read.qxmd.com/read/32448296/volumetric-modulated-arc-therapy-versus-intensity-modulated-proton-therapy-in-neoadjuvant-irradiation-of-locally-advanced-oesophageal-cancer
#38
JOURNAL ARTICLE
Eren Celik, Wolfgang Baus, Christian Baues, Wolfgang Schröder, Alessandro Clivio, Antonella Fogliata, Marta Scorsetti, Simone Marnitz, Luca Cozzi
BACKGROUND: To investigate the role of intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT), realised with RapidArc and RapidPlan methods (RA_RP) for neoadjuvant radiotherapy in locally advanced oesophagal cancer. METHODS: Twenty patients were retrospectively planned for IMPT (with two fields, (IMPT_2F) or with three fields (IMPT_3F)) and RA_RP and the results were compared according to dose-volume metrics. Estimates of the excess absolute risk (EAR) of secondary cancer induction were determined for the lungs...
May 24, 2020: Radiation Oncology
https://read.qxmd.com/read/32334484/cyberknife-helical-tomotherapy-and-rapid-arc-sib-sbrt-treatment-plan-comparison-for-carcinoma-prostate
#39
JOURNAL ARTICLE
Bijina T K, Ganesh K M, Pichandi A, Muthuselvi C A
BACKGROUND: This study was conducted to dosimetrically compare plan quality of Simultaneous Integrated Boost - Stereotactic Body Radiotherapy (SIB-SBRT) generated for different techniques such as Cyberknife (CK), Helical Tomotherapy (HT) and RapidArc (RA) for carcinoma prostate with same treatment margins. MATERIALS AND METHODS: SIB-SBRT plans were generated for CK, HT and RA for thirteen CT data sets. The dose prescription was 45Gy in 5 fractions to GTV45 and 37...
April 1, 2020: Asian Pacific Journal of Cancer Prevention: APJCP
https://read.qxmd.com/read/32075389/long-term-clinical-results-of-igrt-in-prostate-cancer-treatment
#40
JOURNAL ARTICLE
M- Doležel, K- Odrážka, J Vaňásek, J Štuk, A Hlávka, M Vítková, V Ulrych, T Kohlová, Z Vlachová, A Hafuda, I Hartmann
BACKGROUND: The combination of intensity modulated radiation therapy (IMRT) and image guided radiotherapy (IGRT) plays a significant role in sparing normal tissue during prostate cancer treatment. We report the clinical outcomes of 260 patients treated with high-dose IGRT as well as the toxicity of high-dose IGRT in these patients. MATERIALS AND METHODS: From September 2008 to February 2012, 260 men with clinically localized prostate cancer underwent radical radiotherapy...
2020: Klinická Onkologie: Casopis Ceské a Slovenské Onkologické Spolecnosti
keyword
keyword
82626
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.