keyword
MENU ▼
Read by QxMD icon Read
search

Cardiac output monitoring

keyword
https://www.readbyqxmd.com/read/28934895/high-early-fluid-input-after-aneurysmal-subarachnoid-hemorrhage-combined-report-of-association-with-delayed-cerebral-ischemia-and-feasibility-of-cardiac-output-guided-fluid-restriction
#1
Leonie J M Vergouw, Mohamud Egal, Bas Bergmans, Diederik W J Dippel, Hester F Lingsma, Mervyn D I Vergouwen, Peter W A Willems, Annemarie W Oldenbeuving, Jan Bakker, Mathieu van der Jagt
BACKGROUND: Guidelines on the management of aneurysmal subarachnoid hemorrhage (aSAH) recommend euvolemia, whereas hypervolemia may cause harm. We investigated whether high early fluid input is associated with delayed cerebral ischemia (DCI), and if fluid input can be safely decreased using transpulmonary thermodilution (TPT). METHODS: We retrospectively included aSAH patients treated at an academic intensive care unit (2007-2011; cohort 1) or managed with TPT (2011-2013; cohort 2)...
January 1, 2017: Journal of Intensive Care Medicine
https://www.readbyqxmd.com/read/28928561/periprocedural-management-of-vein-of-galen-aneurysmal-malformation-patients-an-11-year-experience
#2
Ajay Prasad Hrishi, Karen Ruby Lionel
CONTEXT: The vein of Galen aneurysmal malformation (VGAM) is a rare arteriovenous malformation where a dilated median prosencephalic vein provides a low-resistance conduit for intracerebral blood flow resulting in high-output cardiac failure, severe pulmonary hypertension, with or without central nervous system symptoms secondary to hydrocephalus, in the neonatal and pediatric population. AIM: This study aims to analysis of the anesthetic management of this unique subset of patients with VGAM...
July 2017: Anesthesia, Essays and Researches
https://www.readbyqxmd.com/read/28927232/association-between-intradialytic-central-venous-oxygen-saturation-and-ultrafiltration-volume-in-chronic-hemodialysis-patients
#3
Hanjie Zhang, Lili Chan, Anna Meyring-Wösten, Israel Campos, Priscila Preciado, Jeroen P Kooman, Frank M van der Sande, Doris Fuertinger, Stephan Thijssen, Peter Kotanko
Background: Cardiac disease is highly prevalent in hemodialysis (HD) patients. Decreased tissue perfusion, including cardiac, due to high ultrafiltration volumes (UFVs) is considered to be one of the drivers of cardiac dysfunction. While central venous oxygen saturation (ScvO 2 ) is frequently used as an indicator of cardiac output in non-uremic populations, the relationship of ScvO 2 and UFV in HD patients remains unclear. Our aim was to determine how intradialytic ScvO 2 changes associate with UFV...
September 12, 2017: Nephrology, Dialysis, Transplantation
https://www.readbyqxmd.com/read/28925377/applied-upper-airway-resistance-instantly-affects-breath-components-a-unique-insight-into-pulmonary-medicine
#4
Pritam Sukul, Jochen Schubert, Svend Kamysek, Phillip Trefz, Wolfram Miekisch
Respiratory parameters such as flow or rate have complex effects onto exhalation of volatile substances and can hamper clinical interpretation of breath biomarkers. We investigated effects of progressively applied upper-airway resistances onto exhalation of volatile organic compounds (VOCs) in healthy humans. We performed real-time mass-spectrometric determination of breath volatiles in 50 subjects with parallel non-invasive hemodynamic monitoring, breath-resolved spirometry and capnometry during controlled tidal breathing (12 breaths/min)...
September 19, 2017: Journal of Breath Research
https://www.readbyqxmd.com/read/28912726/cardiovascular-and-muscular-consequences-of-work-matched-interval-type-of-concentric-and-eccentric-pedaling-exercise-on-a-soft-robot
#5
Martin Flück, Rebekka Bosshard, Max Lungarella
Eccentric types of endurance exercise are an acknowledged alternative to conventional concentric types of exercise rehabilitation for the cardiac patient, because they reduce cardiorespiratory strain due to a lower metabolic cost of producing an equivalent mechanical output. The former contention has not been tested in a power- and work-matched situation of interval-type exercise under identical conditions because concentric and eccentric types of exercise pose specific demands on the exercise machinery, which are not fulfilled in current practice...
2017: Frontiers in Physiology
https://www.readbyqxmd.com/read/28902662/circadian-hemodynamics-in-men-and-women-with-high-blood-pressure-dipper-vs-nondipper-and-racial-differences
#6
Andrew Sherwood, LaBarron K Hill, James A Blumenthal, Alan L Hinderliter
OBJECTIVE: The 'nondipping' pattern of circadian blood pressure (BP) variation is an established independent predictor of adverse cardiovascular outcomes. Although this phenomenon has been widely studied, its underlying circadian hemodynamics of cardiac output and systemic vascular resistance (SVR) have not been well characterized. We evaluated the hypothesis that BP nondipping would be associated with a blunted night-time reduction in SVR in a biracial sample of 140 (63 African-American and 77 white) men and women with elevated clinic BP (130-159/85-99 mmHg)...
September 11, 2017: Journal of Hypertension
https://www.readbyqxmd.com/read/28890555/perioperative-fluid-management-from-physiology-to-improving-clinical-outcomes
#7
REVIEW
Victoria A Bennett, Maurizio Cecconi
Perioperative fluid management is a key component in the care of the surgical patient. It is an area that has seen significant changes and developments, however there remains a wide disparity in practice between clinicians. Historically, patients received large volumes of intravenous fluids perioperatively. The concept of goal directed therapy was then introduced, with the early studies showing significant improvements in morbidity and mortality. The current focus is on fluid therapy guided by an individual patient's physiology...
August 2017: Indian Journal of Anaesthesia
https://www.readbyqxmd.com/read/28885662/differential-diagnosis-of-alterations-in-arterial-flow-and-tissue-oxygenation-on-venoarterial-extracorporeal-membrane-oxygenation
#8
Anna Hofer, Sylvia Leitner, Michaela Kreuzer, Jens Meier
BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) may be life-saving in several clinical situations, but it is also one of the most invasive therapeutic procedures, with significant potential for life-threatening complications. Pulse pressure waves are typically very small or even absent at the onset of ECMO therapy, and will reappear with the improvement of cardiac function. A low pulse pressure may indicate low cardiac output due to heart failure during sustained ECMO support...
September 5, 2017: International Journal of Artificial Organs
https://www.readbyqxmd.com/read/28868168/validity-of-pulse-pressure-variation-ppv-compared-with-stroke-volume-variation-svv-in-predicting-fluid-responsiveness
#9
Abhishek Rathore, Shalendra Singh, Ritesh Lamsal, Priya Taank, Debashish Paul
OBJECTIVE: Static monitors for assessing the fluid status during major surgeries and in critically ill patients have been gradually replaced by more accurate dynamic monitors in modern-day anaesthesia practice. Pulse pressure variation (PPV) and systolic pressure variation (SPV) are the two commonly used dynamic indices for assessing fluid responsiveness. METHODS: In this prospective observational study, 50 patients undergoing major surgeries were monitored for PPV and SPV: after the induction of anaesthesia and after the administration of 500 mL of isotonic crystalloid bolus...
August 2017: Turkish Journal of Anaesthesiology and Reanimation
https://www.readbyqxmd.com/read/28866972/comparison-of-continous-wave-doppler-ultrasound-monitor-and-echocardiography-to-assess-cardiac-output-in-intensive-care-patients
#10
Ahmad Elgendy, Ian M Seppelt, Andrew S Lane
BACKGROUND: Continuous-wave Doppler (CWD) ultrasound through the left ventricular outflow tract is one modality used for non-invasive cardiac output measurement. The ultrasonic cardiac output monitor (USCOM) is a relatively new monitor which uses a small, transcutaneous ultrasound probe to measure cardiac output with CWD via the suprasternal window. It is faster and less complex to train new users than conventional echocardiography. In addition to stroke volume (SV), the USCOM can calculate stroke volume variation (SVV) and the Smith-Madigan inotropy index (SMII), which is an estimate of the pre-load independent contractility of the myocardium...
September 2017: Critical Care and Resuscitation: Journal of the Australasian Academy of Critical Care Medicine
https://www.readbyqxmd.com/read/28864438/measuring-stroke-volume-impedance-cardiography-vs-phase-contrast-magnetic-resonance-imaging
#11
Matthew Borzage, Kimia Heidari, Thomas Chavez, Istvan Seri, John C Wood, Stefan Blüml
BACKGROUND: Determination of cardiac output requires measurement of both heart rate and stroke volume. Techniques for measuring heart rate are widespread, and 1 technique for bedside monitoring of stroke volume is electrical impedance cardiography. OBJECTIVES: To determine the accuracy and precision of stroke volume measured via impedance cardiography and whether the technique can be used to detect trends. METHODS: Eleven healthy research participants (22-52 years old) were examined with simultaneous impedance cardiography and phase-contrast magnetic resonance imaging at rest and during exercise...
September 2017: American Journal of Critical Care: An Official Publication, American Association of Critical-Care Nurses
https://www.readbyqxmd.com/read/28857520/a-combination-of-levobupivacaine-and-lidocaine-for-paravertebral-block-in-breast-cancer-patients-undergoing-quadrantectomy-causes-greater-hemodynamic-oscillations-than-levobupivacaine-alone
#12
RANDOMIZED CONTROLLED TRIAL
Miroslav Župčić, Sandra Graf Župčić, Viktor Duzel, Tatjana Šimurina, Livija Šakić, Jurica Fudurić, Jasminka Peršec, Milan Milošević, Zdenko Stanec, Anđelko Korušić, Stjepan Barišin
AIM: To test for differences in hemodynamic and analgesic properties in patients with breast cancer undergoing quadrantectomy with paravertebral block (PVB) induced with a solution of either one or two local anesthetics. METHOD: A prospective, single-center, randomized, double-blinded, controlled trial was conducted from June 2014 until September 2015. A total of 85 women with breast cancer were assigned to receive PVB with either 0.5% levobupivacaine (n=42) or 0...
August 31, 2017: Croatian Medical Journal
https://www.readbyqxmd.com/read/28856576/changes-in-transcranial-motor-evoked-potentials-during-hemorrhage-are-associated-with-increased-serum-propofol-concentrations
#13
Jeremy A Lieberman, John Feiner, Mark Rollins, Russ Lyon
Transcranial motor evoked potentials (TcMEPs) monitor the integrity of the spinal cord during spine surgery. Propofol-based anesthesia is favored in order to enhance TcMEP quality. During intraoperative hemorrhage, TcMEP amplitudes may be reduced. The serum concentration of propofol may increase during hemorrhage. No study has determined whether changes in TcMEPs due to hemorrhage are related to changes in propofol blood levels. We monitored TcMEPs, mean arterial pressure (MAP), and cardiac output (CO) and hemoglobin in pigs (n = 6) undergoing controlled progressive hemorrhage during a standardized anesthetic with infusions of propofol, ketamine, and fentanyl...
August 30, 2017: Journal of Clinical Monitoring and Computing
https://www.readbyqxmd.com/read/28833080/non-invasive-monitoring-of-the-cardiac-effects-of-continuous-intravenous-oxytocin-infusion-during-cesarean-delivery
#14
Hiroaki Tanaka, Kayo Tanaka, Makoto Tsuji, Shoichi Magawa, Fumi Hatano, Masafumi Nii, Tomoaki Ikeda
No abstract text is available yet for this article.
August 21, 2017: International Journal of Gynaecology and Obstetrics
https://www.readbyqxmd.com/read/28822023/pulse-contour-derived-cardiac-output-measurements-in-morbid-obesity-influence-of-actual-ideal-and-adjusted-bodyweight
#15
Chantal A Boly, Pieter Schraverus, Floris van Raalten, Jan-Willem Coumou, Christa Boer, Simone van Kralingen
The non-invasive Nexfin cardiac output (CO) monitor shows a low level of agreement with the gold standard thermodilution method in morbidly obese patients. Here we investigate whether this disagreement is related to excessive bodyweight, and can be improved when bodyweight derivatives are used instead. We performed offline analyses of cardiac output recordings of patient data previously used and partly published in an earlier study by our group. In 30 morbidly obese patients (BMI > 35 kg/m(2)) undergoing laparoscopic gastric bypass, cardiac output was simultaneously determined with PiCCO thermodilution and Nexfin pulse-contour method...
August 18, 2017: Journal of Clinical Monitoring and Computing
https://www.readbyqxmd.com/read/28820609/cardio-pulmonary-interactions-physiologic-basis-and-clinical-applications
#16
Michael R Pinsky
The hemodynamic effects of ventilation can be grouped into three concepts: 1) spontaneous ventilation is exercise; 2) changes in lung volume alter autonomic tone, pulmonary vascular resistance, and can compress the heart in the cardiac fossa; 3) spontaneous inspiratory efforts decrease intrathoracic pressure (ITP) increasing venous return and impeding left ventricular (LV) ejection; whereas positive pressure ventilation decreases venous return and unloads LV ejection. Spontaneous inspiratory efforts may induce acute LV failure and cardiogenic pulmonary edema...
August 18, 2017: Annals of the American Thoracic Society
https://www.readbyqxmd.com/read/28819317/intradialytic-central-venous-oxygen-saturation-is-associated-with-clinical-outcomes-in-hemodialysis-patients
#17
Lili Chan, Hanjie Zhang, Anna Meyring-Wösten, Israel Campos, Doris Fuertinger, Stephan Thijssen, Peter Kotanko
Central venous oxygen saturation (ScvO2) in the superior vena cava is predominantly determined by cardiac output, arterial oxygen content, and oxygen consumption by the upper body. While abnormal ScvO2 levels are associated with morbidity and mortality in non-uremic populations, ScvO2 has received little attention in hemodialysis patients. From 1/2012 to 8/2015, 232 chronic hemodialysis patients with central venous catheters as vascular access had their ScvO2 monitored during a 6-month baseline period and followed for up to 36 months...
August 17, 2017: Scientific Reports
https://www.readbyqxmd.com/read/28804906/efficacy-of-a-mephentermine-based-product-as-a-vasopressor-and-a-cardiac-performance-enhancer-when-given-intramuscularly-to-cattle
#18
D N Q Cunha, C L Del Rio, B L Youngblood, E L Ferris, G E Geist, Y Ueyama, L C Franz, S Mathur, R L Hamlin
The goal of this study was to confirm the vasopressor and cardiac effects of POTENAY(®) INJETÁVEL (POT), a mephentermine-based product, given to cattle with induced vascular/cardiac depression. Ten healthy Holstein cattle (206 ± 13 kg) followed a randomized-complete-block design (RCBD) utilizing crossover study design. Each animal randomly received (1 ml/25 kg, IM) of either POT (n = 10) or volume-matched placebo control (0.9%NaCl, CP, n = 10). A subset of animals (n = 5) received POT first (day 0) while the remaining (n = 5) received CP; after a six-day washout period, cattle received the opposite compound...
August 14, 2017: Journal of Veterinary Pharmacology and Therapeutics
https://www.readbyqxmd.com/read/28803717/noninvasive-stroke-volume-variation-using-electrical-velocimetry-for-predicting-fluid-responsiveness-in-dogs-undergoing-cardiac-surgery
#19
Kazumasu Sasaki, Tatsushi Mutoh, Tomoko Mutoh, Yasuyuki Taki, Ryuta Kawashima
OBJECTIVE: To evaluate the ability of a noninvasive cardiac output monitoring system with electrical velocimetry (EV) for predicting fluid responsiveness in dogs undergoing cardiac surgery. STUDY DESIGN: Prospective experimental trial. ANIMALS: A total of 30 adult Beagle dogs. METHODS: Stroke volume (SV), stroke volume variation (SVV) and cardiac index were measured using the EV device in sevoflurane-anaesthetized, mechanically ventilated dogs undergoing thoracotomies for experimental creation of right ventricular failure...
January 11, 2017: Veterinary Anaesthesia and Analgesia
https://www.readbyqxmd.com/read/28803439/comparison-of-the-ability-of-escco-and-volume-view-to-measure-trends-in-cardiac-output-in-patients-undergoing-cardiac-surgery
#20
Stephanie Dache, Nicolas Van Rompaey, Alexandre Joosten, Olivier Desebbe, Sarah Saxena, Frederic Vanden Eynden, Caroline Van Aelbrouck, Isabelle Huybrechts, Luc Van Obbergh, Luc Barvais
BACKGROUND: Cardiac output (CO) is a physiological variable that should be monitored during cardiac surgery. The purpose of this study was to assess the trending ability of two CO monitors, esCCO (Nihon Kohden™, Tokyo, Japan) and Volume View (VV) (Edwards Lifesciences, Irvine, USA). METHODS: A total of 19 patients were included in the study. Before cardiopulmonary bypass (CPB), CO was measured simultaneously using both esCCO and VV devices before and after three CO-modifying manoeuvres (passive leg raise [PLR], the end expiratory occlusion test [EEOT] and positive end expiratory pressure [PEEP] at 10 cm H₂O)...
2017: Anaesthesiology Intensive Therapy
keyword
keyword
73723
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"