keyword
MENU ▼
Read by QxMD icon Read
search

Cardiac output monitoring

keyword
https://www.readbyqxmd.com/read/28822023/pulse-contour-derived-cardiac-output-measurements-in-morbid-obesity-influence-of-actual-ideal-and-adjusted-bodyweight
#1
Chantal A Boly, Pieter Schraverus, Floris van Raalten, Jan-Willem Coumou, Christa Boer, Simone van Kralingen
The non-invasive Nexfin cardiac output (CO) monitor shows a low level of agreement with the gold standard thermodilution method in morbidly obese patients. Here we investigate whether this disagreement is related to excessive bodyweight, and can be improved when bodyweight derivatives are used instead. We performed offline analyses of cardiac output recordings of patient data previously used and partly published in an earlier study by our group. In 30 morbidly obese patients (BMI > 35 kg/m(2)) undergoing laparoscopic gastric bypass, cardiac output was simultaneously determined with PiCCO thermodilution and Nexfin pulse-contour method...
August 18, 2017: Journal of Clinical Monitoring and Computing
https://www.readbyqxmd.com/read/28820609/cardio-pulmonary-interactions-physiologic-basis-and-clinical-applications
#2
Michael R Pinsky
The hemodynamic effects of ventilation can be grouped into three concepts: 1) spontaneous ventilation is exercise; 2) changes in lung volume alter autonomic tone, pulmonary vascular resistance, and can compress the heart in the cardiac fossa; 3) spontaneous inspiratory efforts decrease intrathoracic pressure (ITP) increasing venous return and impeding left ventricular (LV) ejection; whereas positive pressure ventilation decreases venous return and unloads LV ejection. Spontaneous inspiratory efforts may induce acute LV failure and cardiogenic pulmonary edema...
August 18, 2017: Annals of the American Thoracic Society
https://www.readbyqxmd.com/read/28819317/intradialytic-central-venous-oxygen-saturation-is-associated-with-clinical-outcomes-in-hemodialysis-patients
#3
Lili Chan, Hanjie Zhang, Anna Meyring-Wösten, Israel Campos, Doris Fuertinger, Stephan Thijssen, Peter Kotanko
Central venous oxygen saturation (ScvO2) in the superior vena cava is predominantly determined by cardiac output, arterial oxygen content, and oxygen consumption by the upper body. While abnormal ScvO2 levels are associated with morbidity and mortality in non-uremic populations, ScvO2 has received little attention in hemodialysis patients. From 1/2012 to 8/2015, 232 chronic hemodialysis patients with central venous catheters as vascular access had their ScvO2 monitored during a 6-month baseline period and followed for up to 36 months...
August 17, 2017: Scientific Reports
https://www.readbyqxmd.com/read/28804906/efficacy-of-a-mephentermine-based-product-as-a-vasopressor-and-a-cardiac-performance-enhancer-when-given-intramuscularly-to-cattle
#4
D N Q Cunha, C L Del Rio, B L Youngblood, E L Ferris, G E Geist, Y Ueyama, L C Franz, S Mathur, R L Hamlin
The goal of this study was to confirm the vasopressor and cardiac effects of POTENAY(®) INJETÁVEL (POT), a mephentermine-based product, given to cattle with induced vascular/cardiac depression. Ten healthy Holstein cattle (206 ± 13 kg) followed a randomized-complete-block design (RCBD) utilizing crossover study design. Each animal randomly received (1 ml/25 kg, IM) of either POT (n = 10) or volume-matched placebo control (0.9%NaCl, CP, n = 10). A subset of animals (n = 5) received POT first (day 0) while the remaining (n = 5) received CP; after a six-day washout period, cattle received the opposite compound...
August 14, 2017: Journal of Veterinary Pharmacology and Therapeutics
https://www.readbyqxmd.com/read/28803717/noninvasive-stroke-volume-variation-using-electrical-velocimetry-for-predicting-fluid-responsiveness-in-dogs-undergoing-cardiac-surgery
#5
Kazumasu Sasaki, Tatsushi Mutoh, Tomoko Mutoh, Yasuyuki Taki, Ryuta Kawashima
OBJECTIVE: To evaluate the ability of a noninvasive cardiac output monitoring system with electrical velocimetry (EV) for predicting fluid responsiveness in dogs undergoing cardiac surgery. STUDY DESIGN: Prospective experimental trial. ANIMALS: A total of 30 adult Beagle dogs. METHODS: Stroke volume (SV), stroke volume variation (SVV) and cardiac index were measured using the EV device in sevoflurane-anaesthetized, mechanically ventilated dogs undergoing thoracotomies for experimental creation of right ventricular failure...
January 11, 2017: Veterinary Anaesthesia and Analgesia
https://www.readbyqxmd.com/read/28803439/comparison-of-the-ability-of-escco-and-volume-view-to-measure-trends-in-cardiac-output-in-patients-undergoing-cardiac-surgery
#6
Stephanie Dache, Nicolas Van Rompaey, Alexandre Joosten, Olivier Desebbe, Sarah Saxena, Frederic Vanden Eynden, Caroline Van Aelbrouck, Isabelle Huybrechts, Luc Van Obbergh, Luc Barvais
BACKGROUND: Cardiac output (CO) is a physiological variable that should be monitored during cardiac surgery. The purpose of this study was to assess the trending ability of two CO monitors, esCCO (Nihon Kohden™, Tokyo, Japan) and Volume View (VV) (Edwards Lifesciences, Irvine, USA). METHODS: A total of 19 patients were included in the study. Before cardiopulmonary bypass (CPB), CO was measured simultaneously using both esCCO and VV devices before and after three CO-modifying manoeuvres (passive leg raise [PLR], the end expiratory occlusion test [EEOT] and positive end expiratory pressure [PEEP] at 10 cm H₂O)...
2017: Anaesthesiology Intensive Therapy
https://www.readbyqxmd.com/read/28798198/wearable-ballistocardiogram-and-seismocardiogram-systems-for-health-and-performance
#7
Mozziyar Etemadi, Omer T Inan
Cardiovascular diseases (CVDs) are prevalent in the US and many forms of CVDs primarily affect the mechanical aspects of heart function. Wearable technologies for monitoring the mechanical health of the heart and vasculature could enable proactive management of CVDs through titration of care based on physiological status, as well as preventative wellness monitoring to help promote lifestyle choices that reduce the overall risk of developing CVDs. Additionally, such wearable technologies could be used to optimize human performance in austere environments...
August 10, 2017: Journal of Applied Physiology
https://www.readbyqxmd.com/read/28795669/-evaluation-of-volume-overload-in-critical-patients-by-monitoring-change-of-cardiac-output-under-bed-head-raising-combined-with-passive-leg-raising
#8
Long Zhang, Luhao Wang, Weixiong Luo, Meihua Mei, Youjuan Chen, Bin Ouyang
OBJECTIVE: To investigate whether the change of cardiac output (CO) with bed head raising (BHR) combined with passive leg raising (PLR) can be used to assess volume overload in critical patients. METHODS: A prospective observational diagnostic trial was designed. The patients who underwent fluid resuscitation 6 hours or more, and admitted to intensive care unit (ICU) of Meizhou People's Hospital in Guangdong Province from January to December in 2016 were enrolled...
August 2017: Zhonghua Wei Zhong Bing Ji Jiu Yi Xue
https://www.readbyqxmd.com/read/28780659/preconception-counseling-for-women-with-cardiac-disease
#9
REVIEW
Mark A Clapp, Sarah N Bernstein
All providers who care for reproductive-aged women with cardiac disease should assess these patients' desires and plans for pregnancy at every encounter. For those considering pregnancy, preconception counseling, often performed by a maternal-fetal medicine specialist, can help patients understand the potential implications of pregnancy on their health and estimate the risks of an adverse cardiac event prior to conceiving. There are cardiac conditions, such as pulmonary hypertension and aortic stenosis, in which pregnancy may be contraindicated given the high morbidity and mortality; there are tools available to help quantify a patient's risk...
September 2017: Current Treatment Options in Cardiovascular Medicine
https://www.readbyqxmd.com/read/28765741/experience-with-mechanical-circulatory-support-for-medically-intractable-low-cardiac-output-in-a-pediatric-intensive-care-unit
#10
Jung Bin Park, Jae Gun Kwak, Hong-Gook Lim, Woong-Han Kim, Jeong Ryul Lee, Yong Jin Kim
BACKGROUND AND OBJECTIVES: Mechanical circulatory support with extracorporeal membrane oxygenation (ECMO) and ventricular assist device has always been the optimal choice for treating the majority of medically intractable low cardiac output case. We retrospectively investigated our institution's outcomes and variables associated with a high risk of mortality. SUBJECTS AND METHODS: From 1999 to 2014, 86 patients who were of pediatric age or had grown-up congenital heart disease underwent mechanical circulatory support for medically intractable low cardiac output in our pediatric intensive care unit...
July 2017: Korean Circulation Journal
https://www.readbyqxmd.com/read/28762449/the-value-of-internal-jugular-vein-collapsibility-index-in-sepsis
#11
Murat Haliloğlu, Beliz Bilgili, Alper Kararmaz, İsmail Cinel
BACKGROUND: Rapid, accurate, and reproducible assessment of intravascular volume status is crucial in order to predict the efficacy of volume expansion in septic patients. The aim of this study was to verify the feasibility and usefulness of the internal jugular vein collapsibility index (IJV-CI) as an adjunct to the inferior vena cava collapsibility index (IVC-CI) to predict fluid responsiveness in spontaneously-breathing patients with sepsis. METHODS: Three stages of sonographic scanning were performed...
July 2017: Ulusal Travma Ve Acil Cerrahi Dergisi, Turkish Journal of Trauma & Emergency Surgery: TJTES
https://www.readbyqxmd.com/read/28753499/non-invasive-cardiac-output-monitoring-nicom-%C3%A2-can-predict-the-evolution-of-uteroplacental-disease-results-of-the-prospective-handle-study
#12
Cathy Monteith, Lisa McSweeney, Colm R Breatnach, Anne Doherty, Lucy Shirren, Elizabeth C Tully, Patrick Dicker, Fergal D Malone, Afif El-Khuffash, Etaoin Kent
OBJECTIVES: We aimed to firstly identify the different haemodynamic profiles amongst nulliparous women who develop either gestational hypertension (GH), pre-eclampsia (PE), normotensive fetal growth restriction (FGR) versus unaffected pregnancies using non-invasive cardiac output monitoring (NICOM(®)). Our second primary objective was to assess the ability of NICOM(®) derived variables to predict the evolution of PE, GH and FGR. STUDY DESIGN: Low risk nulliparous women were enrolled in a single center prospective observational study...
July 20, 2017: European Journal of Obstetrics, Gynecology, and Reproductive Biology
https://www.readbyqxmd.com/read/28747363/changes-in-cardiac-output-and-cerebral-oxygenation-during-prone-and-supine-sleep-positioning-in-healthy-term-infants
#13
Tai-Wei Wu, Rey-In Lien, Istvan Seri, Shahab Noori
OBJECTIVE: To investigate the changes in systemic and cerebral haemodynamics between supine and prone sleep in healthy term infants during the early postnatal period. DESIGN/METHODS: Healthy term infants without congenital anomalies, patent ductus arteriosus and/or small for gestational age status were enrolled. Infants were placed in supine (SP1), prone (PP) and back in supine (SP2) position for 15 min each while asleep. Cardiac output (CO) and stroke volume (SV) were assessed by electrical velocimetry (EV) and echocardiography (echo), and cerebral regional oxygen saturation (CrSO2) in the frontal lobes was monitored by near-infrared spectroscopy...
July 26, 2017: Archives of Disease in Childhood. Fetal and Neonatal Edition
https://www.readbyqxmd.com/read/28746233/preoperative-thromboelastometry-for-the-prediction-of-increased-chest-tube-output-in-cardiac-surgery-a-retrospective-study
#14
Waldemar Gozdzik, Barbara Adamik, Grzegorz Wysoczanski, Anna Gozdzik, Maciej Rachwalik, Tomasz Skalec, Andrzej Kübler
Bleeding following cardiac surgery is a serious event with potentially life-threatening consequences. Preoperative recognition of coagulation abnormalities and detection of cardiopulmonary bypass (CPB) related coagulopathy could aid in the start of preventive treatment strategies that minimize perioperative blood loss. Most algorithms that analyze thromboelastometry coagulation tests in elective cardiac surgery do not include test results performed before surgery. We evaluated preoperative rotational thromboelastometry test results for their ability to predict blood loss during and after cardiac surgery...
July 2017: Medicine (Baltimore)
https://www.readbyqxmd.com/read/28733057/clinical-validation-of-non-invasive-cardiac-output-monitoring-in-healthy-pregnant-women
#15
Kelsey McLaughlin, Stephen P Wright, John C P Kingdom, John D Parker
OBJECTIVE: Non-invasive hemodynamic monitoring has the potential to be a valuable clinical tool for the screening and management of hypertensive disorders of pregnancy. The objective of this study was to validate the clinical utility of the non-invasive cardiac output monitoring (NICOM) system in pregnant women. METHODS: Twenty healthy pregnant women with a singleton pregnancy at 22 to 26 weeks' gestation were enrolled in this study. Measures of heart rate, stroke volume, and cardiac output were obtained through NICOM and compared with Doppler echocardiography...
July 18, 2017: Journal of Obstetrics and Gynaecology Canada: JOGC, Journal D'obstétrique et Gynécologie du Canada: JOGC
https://www.readbyqxmd.com/read/28731900/micro-and-macro-circulatory-changes-during-sepsis-and-septic-shock-in-a-rat-model
#16
Tianfeng Hua, Xiaobo Wu, Wei Wang, Hao Li, Jennifer Bradley, Mary Ann Peberdy, Joseph P Ornato, Wanchun Tang
Microcirculation is the motor of sepsis. In the present study, we investigated whether microcirculatory alterations occur prior to changes of systemic hemodynamics in a rat model of cecum ligation and puncture (CLP)-induced sepsis. We further investigated renal microcirculatory changes during sepsis and compared those with buccal microcirculation. Twelve male Sprague-Dawley rats were randomized into a sham control group (n = 6) and a CLP group (n = 6). Perfused microvessel density (PVD) and microvascular flow index (MFI) were evaluated using sidestream dark field (SDF) video microscopy at baseline, 60, 120, 180, 240, 300, and 360 minutes following CLP...
July 20, 2017: Shock
https://www.readbyqxmd.com/read/28719470/diurnal-variation-and-repeatability-of-arterial-stiffness-and-cardiac-output-measurements-in-the-third-trimester-of-uncomplicated-pregnancy
#17
Mohamed W Osman, Francesca Leone, Mintu Nath, Asma Khalil, David R Webb, Thompson G Robinson, Hatem A Mousa
AIM: To investigate same day repeated measures and diurnal variation of arterial stiffness, cardiac output (CO), stroke volume (SV) and total peripheral resistance (TPR) during the third trimester of normal pregnancy. METHODOLOGY: Pulse wave velocity (PWV) and augmentation index (AIx) were recorded using the Arteriograph, while CO, SV and TPR were recorded using noninvasive cardiac output monitoring. The measurements were obtained in the third trimester of pregnancy from 21 healthy pregnant women at four time points (morning, afternoon, evening and midnight) over a 24-h period...
July 14, 2017: Journal of Hypertension
https://www.readbyqxmd.com/read/28719069/inaccuracy-of-a-continuous-arterial-pressure-waveform-monitor-when-used-for-congenital-cardiac-catheterization
#18
Michael D Seckeler, Katri Typpo, Jendar Deschenes, Ruth Higgins, Ricardo Samson, Peter Lichtenthal
OBJECTIVE: To determine the accuracy of a continuous cardiac output monitor (FloTrac sensor) for measuring cardiac index in children with congenital heart disease undergoing cardiac catheterization. Cardiac index is a critical hemodynamic parameter measured during catheterizations in children with congenital heart disease. This has been challenging to measure accurately and many clinicians rely on predictive equations for calculating cardiac index. DESIGN: Prospective, nonrandomized trial...
July 18, 2017: Congenital Heart Disease
https://www.readbyqxmd.com/read/28709156/gastrointestinal-impedance-spectroscopy-to-detect-hypoperfusion-during-hemorrhage
#19
Andreas Bloch, Andreas Kohler, Horst Posthaus, David Berger, Laura Santos, Stephan Jakob, Jukka Takala, Matthias Haenggi
BACKGROUND: Changes in tissue impedance (Ω) have been proposed as early signs of impaired tissue perfusion. We hypothesized that hemorrhage may induce early changes in alimentary tract tissue impedance and that these can be detected by impedance spectroscopy. We evaluated impedance spectroscopy in an acute hemorrhage model in pigs. METHODS: Twenty anesthetized pigs were randomized to stepwise hemorrhage to mean arterial blood pressure (MAP) targets of 60 mm Hg, 50 mm Hg, 45 mm Hg, and 40 mm Hg, followed by retransfusion in two steps, or control (n = 10 each)...
August 2017: Shock
https://www.readbyqxmd.com/read/28708664/esmolol-administration-to-control-tachycardia-in-an-ovine-model-of-peritonitis
#20
Koji Hosokawa, Fuhong Su, Fabio Silvio Taccone, Emiel Hendrik Post, Adriano José Pereira, Antoine Herpain, Jacques Creteur, Jean-Louis Vincent
BACKGROUND: Excessive adrenergic signaling may be harmful in sepsis. Using β-blockers to reduce sympathetic overactivity may modulate sepsis-induced cardiovascular, metabolic, immunologic, and coagulation alterations. Using a randomized ovine fecal peritonitis model, we investigated whether administration of a short-acting β-blocker, esmolol, could control tachycardia without deleterious effects on hemodynamics, renal perfusion, cerebral perfusion, cerebral metabolism, or outcome. METHODS: After induction of fecal peritonitis, 14 anesthetized, mechanically ventilated, and hemodynamically monitored adult female sheep were randomly assigned to receive a continuous intravenous infusion of esmolol to control heart rate between 80 and 100 bpm (n = 7) or a saline infusion (control group, n = 7)...
July 13, 2017: Anesthesia and Analgesia
keyword
keyword
73723
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"