keyword
MENU ▼
Read by QxMD icon Read
search

Cardiac output monitoring

keyword
https://www.readbyqxmd.com/read/28320891/the-normal-ranges-of-cardiovascular-parameters-measured-using-the-ultrasonic-cardiac-output-monitor
#1
Giles N Cattermole, P Y Mia Leung, Grace Y L Ho, Peach W S Lau, Cangel P Y Chan, Stewart S W Chan, Brendan E Smith, Colin A Graham, Timothy H Rainer
The ultrasonic cardiac output monitor (USCOM) is a noninvasive transcutaneous continuous wave Doppler method for assessing hemodynamics. There are no published reference ranges for normal values in adults (aged 18-60 years) for this device. This study aimed to (1) measure cardiovascular indices using USCOM in healthy adults aged 18-60 years; (2) combine these data with those for healthy children (aged 0-12), adolescents (aged 12-18), and the elderly (aged over 60) from our previously published studies in order to present normal ranges for all ages, and (3) establish normal ranges of USCOM-derived variables according to both weight and age...
March 2017: Physiological Reports
https://www.readbyqxmd.com/read/28320068/thoracic-electrical-bioimpedance-versus-suprasternal-doppler-in-emergency-care
#2
Mohammed H Elwan, Jeremy Hue, Samira J Green, Salah M Eltahan, Mark R Sims, Timothy J Coats
OBJECTIVE: There are a number of cardiac output (CO) monitors that could potentially be used in the ED. Two of the most promising methods, thoracic electrical bioimpedance and suprasternal Doppler, have not been directly compared. The aim of this study was to investigate the feasibility of CO monitoring using suprasternal Doppler and bioimpedance in emergency care and compare haemodynamic data obtained from both monitors. METHODS: Haemodynamic measurements were made on the same group of patients using bioimpedance (Niccomo, Medis, Germany) and suprasternal Doppler (USCOM, Sydney, Australia)...
March 20, 2017: Emergency Medicine Australasia: EMA
https://www.readbyqxmd.com/read/28295749/nitric-oxide-no-donors-and-haemodynamic-changes-in-fetal-growth-restriction
#3
G M Tiralongo, I Pisani, B Vasapollo, A Khalil, B Thilaganathan, H Valensise
OBJECTIVE: To evaluate maternal cardiovascular effects of nitric oxide (NO) donors in pregnancies complicated by fetal growth restriction (FGR) METHODS: 26 women with a diagnosis of FGR were treated with transdermal patches of NO donors and plasma volume expansion. We compared the treated group to a control historical FGR untreated group of patients evaluated longitudinally. We obtained haemodynamic indices using UltraSonic Cardiac Output Monitor system. RESULTS: At enrolment, the two groups were similar in terms of maternal and haemodynamic characteristics...
March 10, 2017: Ultrasound in Obstetrics & Gynecology
https://www.readbyqxmd.com/read/28290239/an-innovative-design-for-cardiopulmonary-resuscitation-manikins-based-on-a-human-like-thorax-and-embedded-flow-sensors
#4
Mark Thielen, Rohan Joshi, Frank Delbressine, Sidarto Bambang Oetomo, Loe Feijs
Cardiopulmonary resuscitation manikins are used for training personnel in performing cardiopulmonary resuscitation. State-of-the-art cardiopulmonary resuscitation manikins are still anatomically and physiologically low-fidelity designs. The aim of this research was to design a manikin that offers high anatomical and physiological fidelity and has a cardiac and respiratory system along with integrated flow sensors to monitor cardiac output and air displacement in response to cardiopulmonary resuscitation. This manikin was designed in accordance with anatomical dimensions using a polyoxymethylene rib cage connected to a vertebral column from an anatomical female model...
March 2017: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of Engineering in Medicine
https://www.readbyqxmd.com/read/28277383/the-use-of-vasopressors-during-spinal-anaesthesia-for-caesarean-section
#5
Warwick D Ngan Kee
PURPOSE OF REVIEW: Hypotension remains one of the most researched subjects in obstetric anaesthesia. The purpose of this study is to review the most recent published articles on the use of vasopressors during spinal anaesthesia for caesarean section. RECENT FINDINGS: Despite continued research indicating advantages of phenylephrine over ephedrine, practitioners in some countries continue to favour ephedrine. Recent research has continued to compare the two drugs with some work emerging on high-risk patients...
March 8, 2017: Current Opinion in Anaesthesiology
https://www.readbyqxmd.com/read/28269375/non-invasive-cardiac-output-monitoring-in-pharmacology-a-plethysmographie-solution-in-rats
#6
Timothe Flenet, Julie Fontecave-Jallon, Stephane Tanguy, Francois Boucher, Pierre Baconnier, Pierre-Yves Gumery
Cardiovascular monitoring is of great importance in pharmacology but there is a lack of convenient non-invasive alternatives. Hence, we aim to evaluate the relevance of inductive plethysmography (IP) in preclinical cardiac studies. An IP system was specifically designed for rat. Its evaluation carried out using a mechanical test bench has shown appropriate instrumental performances for cardiac monitoring in rats. Measurements were also performed during a volume overload hemodynamic challenge in vivo in rats...
August 2016: Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society
https://www.readbyqxmd.com/read/28268881/a-comparison-between-four-techniques-to-measure-cardiac-output
#7
A Pironet, P C Dauby, J G Chase, P Morimont, N Janssen, B Lambermont, S Davidson, T Desaive
Cardiac output is an important variable when monitoring hemodynamic status. In particular, changes in cardiac output represent the goal of several circulatory management therapies. Unfortunately, cardiac output is very difficult to estimate, either in experimental or clinical settings. The goal of this work is to compare four techniques to measure cardiac output: pressure-volume catheter, aortic flow probe, thermodilution, and the PiCCO monitor. These four techniques were simultaneously used during experiments of fluid and endotoxin administration on 7 pigs...
August 2016: Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society
https://www.readbyqxmd.com/read/28254076/computational-simulation-of-passive-leg-raising-effects-on-hemodynamics-during-cardiopulmonary-resuscitation
#8
Dong Ah Shin, Jiheum Park, Jung Chan Lee, Sang Do Shin, Hee Chan Kim
BACKGROUND AND OBJECTIVE: The passive leg-raising (PLR) maneuver has been used for patients with circulatory failure to improve hemodynamic responsiveness by increasing cardiac output, which should also be beneficial and may exert synergetic effects during cardiopulmonary resuscitation (CPR). However, the impact of the PLR maneuver on CPR remains unclear due to difficulties in monitoring cardiac output in real-time during CPR and a lack of clinical evidence. METHODS: We developed a computational model that couples hemodynamic behavior during standard CPR and the PLR maneuver, and simulated the model by applying different angles of leg raising from 0° to 90° and compression rates from 80/min to 160/min...
March 2017: Computer Methods and Programs in Biomedicine
https://www.readbyqxmd.com/read/28251598/diagnosis-of-cardiac-surgery-associated-acute-kidney-injury-differential-roles-of-creatinine-chitinase-3-like-protein-1-and-neutrophil-gelatinase-associated-lipocalin-a-prospective-cohort-study
#9
Jorien De Loor, Ingrid Herck, Katrien Francois, Astrid Van Wesemael, Lieve Nuytinck, Evelyne Meyer, Eric A J Hoste
BACKGROUND: A common and serious complication of cardiac surgery prompting early detection and intervention is cardiac surgery-associated acute kidney injury (CSA-AKI). Urinary chitinase 3-like protein 1 (UCHI3L1) was found to predict AKI associated with critical illness in adults. Our aims were therefore to evaluate whether UCHI3L1 can also be used to predict AKI associated with elective cardiac surgery in adults, and to compare this predictive ability with that of urinary neutrophil gelatinase-associated lipocalin (UNGAL), more frequently assessed early serum creatinine (SCr) measurements, and various two-biomarker panels...
December 2017: Annals of Intensive Care
https://www.readbyqxmd.com/read/28244881/oral-or-nasal-breathing-real-time-effects-of-switching-sampling-route-onto-exhaled-voc-concentrations
#10
Pritam Sukul, Peter Oertel, Svend Kamysek, Phillip Trefz
There is a need for standardisation in sampling and analysis of breath volatile organic compounds (VOCs) in order to minimise ubiquitous confounding effects. Physiological factors may mask concentration changes induced by pathophysiological effects. In humans, unconscious switching of oral and nasal breathing can occur during breath sampling, which may affect VOC patterns. Here, we investigated exhaled VOC concentrations in real-time while switching breathing routes. Breath from 15 healthy volunteers was analysed continuously by proton transfer reaction time-of-flight mass spectrometry during paced breathing (12 breaths min(-1))...
March 21, 2017: Journal of Breath Research
https://www.readbyqxmd.com/read/28241122/numerical-investigation-of-vasospasm-detection-by-extracranial-blood-velocity-ratios
#11
Jaiyoung Ryu, Nerissa Ko, Xiao Hu, Shawn C Shadden
BACKGROUND: Early diagnosis of vasospasm following subarachnoid hemorrhage can prevent cerebral ischemia and improve neurological outcomes. This study numerically evaluates the relevance of extracranial blood velocity indices to detect vasospasm. METHODS: A numerical model of cerebral blood flow was used to evaluate the hemodynamics associated with anterior and posterior vasospasm under normal and impaired cerebral autoregulation conditions. Extracranial blood velocities at the carotid and vertebral arteries and their ratios between ipsilateral and contralateral, anterior and posterior, and downstream and upstream arteries were monitored during vasospasm progression...
February 28, 2017: Cerebrovascular Diseases
https://www.readbyqxmd.com/read/28238244/nt-probnp-as-a-potential-marker-of-left-atrial-dysfunction-in-rheumatic-mitral-stenosis-correlation-with-left-atrial-function-after-pbmv
#12
Rashi Khare, Sudhanshu Dwivedi
BACKGROUND: Rheumatic heart disease is a common reason for cardiovascular morbidity and mortality. Plasma levels of N-terminal pro-brain natriuretic peptide (NT-proBNP) are known to rise in patients with MS, but the role of this compound as a non-invasive marker of left atrial (LA) dysfunction is yet to be established. The study aim was to correlate levels of NT-proBNP in patients with rheumatic mitral stenosis (MS), with echocardiographic parameters of LA function including tissue Doppler-derived strain/strain rate (S/Sr) indices, hemodynamic parameters of LA function, before and after percutaneous balloon mitral valvotomy (PBMV) for a follow up of one year...
September 2016: Journal of Heart Valve Disease
https://www.readbyqxmd.com/read/28227618/non-invasive-cardiac-output-monitoring-in-pharmacology-a-plethysmographie-solution-in-rats
#13
Timothe Flenet, Julie Fontecave-Jallon, Stephane Tanguy, Francois Boucher, Pierre Baconnier, Pierre-Yves Gumery, Timothe Flenet, Julie Fontecave-Jallon, Stephane Tanguy, Francois Boucher, Pierre Baconnier, Pierre-Yves Gumery, Pierre-Yves Gumery, Pierre Baconnier, Stephane Tanguy, Julie Fontecave-Jallon, Francois Boucher, Timothe Flenet
Cardiovascular monitoring is of great importance in pharmacology but there is a lack of convenient non-invasive alternatives. Hence, we aim to evaluate the relevance of inductive plethysmography (IP) in preclinical cardiac studies. An IP system was specifically designed for rat. Its evaluation carried out using a mechanical test bench has shown appropriate instrumental performances for cardiac monitoring in rats. Measurements were also performed during a volume overload hemodynamic challenge in vivo in rats...
August 2016: Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society
https://www.readbyqxmd.com/read/28227080/a-comparison-between-four-techniques-to-measure-cardiac-output
#14
A Pironet, P C Dauby, J G Chase, P Morimont, N Janssen, B Lambermont, S Davidson, T Desaive, A Pironet, P C Dauby, J G Chase, P Morimont, N Janssen, B Lambermont, S Davidson, T Desaive, T Desaive, B Lambermont, P C Dauby, N Janssen, P Morimont, A Pironet, J G Chase, S Davidson
Cardiac output is an important variable when monitoring hemodynamic status. In particular, changes in cardiac output represent the goal of several circulatory management therapies. Unfortunately, cardiac output is very difficult to estimate, either in experimental or clinical settings. The goal of this work is to compare four techniques to measure cardiac output: pressure-volume catheter, aortic flow probe, thermodilution, and the PiCCO monitor. These four techniques were simultaneously used during experiments of fluid and endotoxin administration on 7 pigs...
August 2016: Conference Proceedings: Annual International Conference of the IEEE Engineering in Medicine and Biology Society
https://www.readbyqxmd.com/read/28219104/captopril-does-not-potentiate-post-exercise-hypotension-a-randomized-crossover-study
#15
Andréia Cristiane Carrenho Queiroz, Julio Cesar Silva Sousa, Natan Daniel Silva, Eleonora Tobaldini, Katia Coelho Ortega, Edilamar Menezes de Oliveira, Patricia Chakur Brum, Nicola Montano, Decio Mion, Taís Tinucci, Claudia Lucia de Moraes Forjaz
To evaluate whether captopril (3×50 mg/day) potentiates post-resistance exercise hypotension (PREH) in hypertensives (HT), 12 HT men received captopril and placebo for 4 weeks each in a double-blinded, randomized-crossover design. On each therapy, subjects underwent 2 sessions: Control (C - rest) and Resistance Exercise (RE - 7 exercises, 3 sets to moderate fatigue, 50% of 1 RM -repetition maximum). Measurements were taken before and after 30-60 min (Post1) and 7 h (Post2), and ambulatory blood pressure (BP) was monitored for 24 h...
February 20, 2017: International Journal of Sports Medicine
https://www.readbyqxmd.com/read/28210936/does-obesity-affect-the-non-invasive-measurement-of-cardiac-output-performed-by-electrical-cardiometry-in-children-and-adolescents
#16
Luis Altamirano-Diaz, Eva Welisch, Ralf Rauch, Michael Miller, Teresa Sohee Park, Kambiz Norozi
Electrical cardiometry (EC) is a non-invasive and inexpensive method for hemodynamic assessment and monitoring. However, its feasibility for widespread clinical use, especially for the obese population, has yet to be determined. In this study, we evaluated the agreement and reliability of EC compared to transthoracic Doppler echocardiography (TTE) in normal, overweight, and obese children and adolescents. We measured stroke volume (SV) and cardiac output (CO) of 131 participants using EC and TTE simultaneously...
February 17, 2017: Journal of Clinical Monitoring and Computing
https://www.readbyqxmd.com/read/28208977/comparison-of-levosimendan-milrinone-and-dobutamine-in-treating-low-cardiac-output-syndrome-following-valve-replacement-surgeries-with-cardiopulmonary-bypass
#17
Sunny, Mohd Yunus, Habib Md Reazaul Karim, Manuj Kumar Saikia, Prithwis Bhattacharyya, Samarjit Dey
INTRODUCTION: Low Cardiac Output Syndrome (LCOS) following Cardiopulmonary Bypass (CPB) is common and associated with increased mortality. Maintenance of adequate cardiac output is one of the primary objectives in management of such patients. AIM: To compare Levosimendan, Milrinone and Dobutamine for the treatment of LCOS after CPB in patients who underwent valve replacement surgeries. MATERIALS AND METHODS: Sixty eligible patients meeting LCOS were allocated into three treatment groups: Group A-Levosimendan (loading dose 10μg/kg over 10 minutes, followed by 0...
December 2016: Journal of Clinical and Diagnostic Research: JCDR
https://www.readbyqxmd.com/read/28206993/hemodynamic-effects-of-sodium-bicarbonate-administration
#18
A C Katheria, M K Brown, K Hassan, D M Poeltler, D A Patel, V K Brown, J B Sauberan
OBJECTIVE: To describe the hemodynamic changes that occur with sodium bicarbonate (NaHCO3) administration in premature neonates. STUDY DESIGN: This retrospective study included premature neonates 23 to 31+6 weeks of gestational age who underwent continuous cardiac and cerebral monitoring as participants in prospective trials at our institution, and who received NaHCO3 infused over 30 min in the first 24 h of life. Blood pressure (BP), heart rate, cardiac output (CO), SpO2 and cerebral oximetry (StO2) were captured every 2 s...
February 16, 2017: Journal of Perinatology: Official Journal of the California Perinatal Association
https://www.readbyqxmd.com/read/28203792/accuracy-and-precision-of-non-invasive-cardiac-output-monitoring-devices-in-perioperative-medicine-a-systematic-review-and-meta-analysis%C3%A2
#19
A Joosten, O Desebbe, K Suehiro, L S-L Murphy, M Essiet, B Alexander, M-O Fischer, L Barvais, L Van Obbergh, D Maucort-Boulch, M Cannesson
No abstract text is available yet for this article.
March 1, 2017: British Journal of Anaesthesia
https://www.readbyqxmd.com/read/28187374/the-strengths-and-weaknesses-of-non-invasive-parameters-obtained-by-echocardiography-and-cardiopulmonary-exercise-testing-in-comparison-with-the-hemodynamic-assessment-by-the-right-heart-catheterization-in-patients-with-pulmonary-hypertension
#20
Katarzyna Ptaszyńska-Kopczyńska, Anna Krentowska, Emilia Sawicka, Anna Skoneczny, Małgorzata Jasiewicz, Małgorzata Knapp, Włodzimierz J Musiał, Bożena Sobkowicz, Karol A Kamiński
PURPOSE: Pulmonary hypertension (PH) diagnosis requires invasive assessment by right heart catheterization (RHC), but screening and monitoring are performed using non-invasive methods: echocardiography and cardiopulmonary exercise testing (CPET). The aim of the study was to assess correlations between the parameters obtained in non-invasive testing and RHC in patients with PH of different etiologies. MATERIAL/METHODS: The study included 53 medical records of PH patients (32 women) aged 29-81 years...
June 14, 2016: Advances in Medical Sciences
keyword
keyword
73723
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"