keyword
https://read.qxmd.com/read/38616989/can-adipokine-fam19a5-be-a-biomarker-of-metabolic-disorders
#21
REVIEW
Agnieszka Wesołek-Leszczyńska, Katarzyna Pastusiak, Paweł Bogdański, Monika Szulińska
AIM: One of the most critical functions of adipose tissue is the production of adipokines, ie, numerous active substances that regulate metabolism. One is the newly discovered FAM19A5, whose older name is TAFA-5. PURPOSE: The study aimed to review the literature on the FAM19A5 protein. METHODS: The review was conducted in December 2023 using the PubMed (Medline) search engine. Sixty-four papers were included in the review. RESULTS: This protein exhibits the characteristics of an adipokine with positive features for maintaining homeostasis...
2024: Diabetes, Metabolic Syndrome and Obesity
https://read.qxmd.com/read/38616032/12-13-dihome-attenuates-high-glucose-induced-calcification-of-vascular-smooth-muscle-cells-through-repressing-cpt1a-mediated-hmgb1-succinylation
#22
JOURNAL ARTICLE
Huahua Li, Lingling Zou, Jin Zheng, Tao Yang
Diabetes is closely associated with vascular calcification (VC). Exorbitant glucose concentration activates pro-calcific effects in vascular smooth muscle cells (VSMCs). This study enrolled 159 elderly patients with type 2 diabetes and divided them into three groups, T1, T2 and T3, according to brachial-ankle pulse wave velocity(BaPWV). There were statistically significant differences in the waist circumference, waist hip ratio, systolic blood pressure, 12,13-diHOME (a lipokin) concentration among T1, T2 and T3...
April 12, 2024: Experimental Cell Research
https://read.qxmd.com/read/38615192/characteristic-fingerprint-spectrum-of-%C3%AE-synuclein-mutants-on-terahertz-time-domain-spectroscopy
#23
JOURNAL ARTICLE
Xiaofang Zhao, Chenlong Yang, Xin Chen, Yu Sun, Weihai Liu, Qinggang Ge, Jun Yang
OBJECTIVE: Alpha-Synuclein (α-Syn), a presynaptic neuronal protein encoded by the SNCA gene, is involved in the pathogenesis of Parkinson's disease. Point mutations and multiplications of the α-Syn (A30P and A53T) are correlated with early-onset Parkinson's disease characterized by rapid progression and poor prognosis. Currently, the clinical identification of SNCA variants, especially disease-related A30P and A53T mutants, remains challenging and also time-consuming. This study has aimed to develop a novel label-free detection method for distinguishing the SNCA mutants using transmission terahertz (THz) time-domain spectroscopy...
April 13, 2024: Biophysical Journal
https://read.qxmd.com/read/38615025/extreme-terahertz-magnon-multiplication-induced-by-resonant-magnetic-pulse-pairs
#24
JOURNAL ARTICLE
C Huang, L Luo, M Mootz, J Shang, P Man, L Su, I E Perakis, Y X Yao, A Wu, J Wang
Nonlinear interactions of spin-waves and their quanta, magnons, have emerged as prominent candidates for interference-based technology, ranging from quantum transduction to antiferromagnetic spintronics. Yet magnon multiplication in the terahertz (THz) spectral region represents a major challenge. Intense, resonant magnetic fields from THz pulse-pairs with controllable phases and amplitudes enable high order THz magnon multiplication, distinct from non-resonant nonlinearities such as the high harmonic generation by below-band gap electric fields...
April 13, 2024: Nature Communications
https://read.qxmd.com/read/38613009/maternal-seafood-consumption-during-pregnancy-and-cardiovascular-health-of-children-at-11-years-of-age
#25
JOURNAL ARTICLE
Ariadna Pinar-Martí, Sílvia Fernández-Barrés, Iolanda Lázaro, Serena Fossati, Silvia Fochs, Núria Pey, Martine Vrijheid, Dora Romaguera, Aleix Sala-Vila, Jordi Julvez
Nutrition is critical during pregnancy for the healthy growth of the developing infant, who is fully dependent on maternal dietary omega-3 supply for development. Fatty fish, a main dietary source of omega-3, is associated with decreased cardiovascular risk in adults. We conducted a longitudinal study based on a mother-offspring cohort as part of the project Infancia y Medio Ambiente (INMA) in order to assess whether fish intake during pregnancy relates to cardiovascular health in children. A total of 657 women were included and followed throughout pregnancy until birth, and their children were enrolled at birth and followed up until age 11-12...
March 27, 2024: Nutrients
https://read.qxmd.com/read/38612693/the-effect-of-low-intensity-pulsed-ultrasound-on-bone-regeneration-and-the-expression-of-osterix-and-cyclooxygenase-2-during-critical-size-bone-defect-repair
#26
JOURNAL ARTICLE
Darian Volarić, Gordana Žauhar, Jie Chen, Ana Terezija Jerbić Radetić, Hrvoje Omrčen, Antonio Raič, Roko Pirović, Olga Cvijanović Peloza
Low-intensity pulsed ultrasound (LIPUS) is a form of ultrasound that utilizes low-intensity pulsed waves. Its effect on bones that heal by intramembranous ossification has not been sufficiently investigated. In this study, we examined LIPUS and the autologous bone, to determine their effect on the healing of the critical-size bone defect (CSBD) of the rat calvaria. The bone samples underwent histological, histomorphometric and immunohistochemical analyses. Both LIPUS and autologous bone promoted osteogenesis, leading to almost complete closure of the bone defect...
March 30, 2024: International Journal of Molecular Sciences
https://read.qxmd.com/read/38610441/differential-sampling-of-ac-waveforms-based-on-a-commercial-digital-to-analog-converter-for-reference
#27
JOURNAL ARTICLE
Yanping Wang, Xiaogang Sun, Jianting Zhao, Kunli Zhou, Yunfeng Lu, Jifeng Qu, Pengcheng Hu, Qing He
This paper introduces an innovative differential sampling technique for calibrating AC waveforms, leveraging a commercially available 16-bit digital-to-analog converter (DAC) as the reference standard. The novelty of this approach lies in its enhanced stability over traditional direct sampling methods, especially as the frequency of the AC waveform increases. Notably, this technique provides a cost-effective sampler alternative to the differential sampling methods that rely on a programmable Josephson voltage standard (PJVS)...
March 30, 2024: Sensors
https://read.qxmd.com/read/38610378/coded-excitation-for-ultrasonic-testing-a-review
#28
REVIEW
Chenxin Weng, Xu Gu, Haoran Jin
Originating in the early 20th century, ultrasonic testing has found increasingly extensive applications in medicine, industry, and materials science. Achieving both a high signal-to-noise ratio and high efficiency is crucial in ultrasonic testing. The former means an increase in imaging clarity as well as the detection depth, while the latter facilitates a faster refresh of the image. It is difficult to balance these two indicators with a conventional short pulse to excite the probe, so in general handling methods, these two factors have a trade-off...
March 28, 2024: Sensors
https://read.qxmd.com/read/38610298/visualizing-a-cold-stress-specific-pulse-wave-in-traditional-pulse-diagnosis-tight-pulse-correlated-with-vascular-changes-in-the-radial-artery-induced-by-a-cold-pressor-trial
#29
JOURNAL ARTICLE
Jichung Song, Jae Young Choi, Byung-Wook Lee, Dongmyung Eom, Chang-Hyun Song
Radial pulse diagnosis is the most common method to examine the human health state in Traditional East Asian Medicine (TEAM). A cold stress-related suboptimal health state (subhealth) is often undetectable during routine medical examinations, however, it can be detected through the palpation of specific pulse waves, particularly a 'tight pulse', in TEAM. Therefore, this study examined a correlation between 'tight pulse' and vascular changes in the radial artery (RA) induced by a cold pressor trial (CPT). Twenty healthy subjects underwent sequentially control trial and CPT with room-temperature and ice-cold water, respectively, on the right forearm...
March 25, 2024: Sensors
https://read.qxmd.com/read/38610240/a-non-inductive-coil-design-used-to-provide-high-frequency-and-large-currents
#30
JOURNAL ARTICLE
Qing Zhu, Yu Su
Currently, cutting-edge, high-frequency current sources are limited by switching devices and wire materials, and the output current cannot take into account the demands of a high peak and low rise time at the same time. Based on the output demand of a current source, a non-inductive coil for providing high-frequency, high current sources with low rise times is designed. The coil is appropriately designed according to the principle of the ampere-turn method, where several turns of wire are utilized to linearly synthesize the current to obtain high-frequency currents with amplitudes up to 30 kA...
March 22, 2024: Sensors
https://read.qxmd.com/read/38608063/electrocardiogram-prediction-of-atrial-fibrillation-risk-after-stroke-a-protocol-for-systematic-review-and-meta-analysis
#31
JOURNAL ARTICLE
Xiaoli Cheng, Xiaoli Wang
BACKGROUND: Atrial fibrillation (AF) is one of the most common clinical arrhythmias. This study aims to predict the risk of post-stroke AF through electrocardiographic changes in sinus rhythm. METHODS: We searched the MEDLINE (PubMed) and EMBASE databases to identify relevant research articles published until August 2023. Prioritized items from systematic reviews and meta-analyses were screened, and data related to AF detection rate were extracted. A meta-analysis using a random-effects model was conducted for data synthesis and analysis...
April 12, 2024: Medicine (Baltimore)
https://read.qxmd.com/read/38607608/endothelial-dysfunction-influences-augmented-aortic-hemodynamic-responses-to-metaboreflex-activation-in-postmenopausal-women
#32
JOURNAL ARTICLE
Mauricio A Martinez, Katherine N Dillon, Yejin Kang, Arun Maharaj, Stephen M Fischer, Arturo Figueroa
PURPOSE: Postmenopausal women experience augmented aortic hemodynamic responses to isometric handgrip (IHG) exercise and metaboreflex activation post-exercise muscle ischemia (PEMI). Relationships between endothelial function brachial artery flow-mediated dilation (FMD) and aortic stiffness carotid-femoral pulse wave velocity (cfPWV) with aortic pulsatile hemodynamics during IHG and PEMI have not been determined. The relationships between aortic hemodynamic responses to PEMI were evaluated...
April 12, 2024: European Journal of Applied Physiology
https://read.qxmd.com/read/38607466/representing-stimulus-motion-with-waves-in-adaptive-neural-fields
#33
JOURNAL ARTICLE
Sage Shaw, Zachary P Kilpatrick
Traveling waves of neural activity emerge in cortical networks both spontaneously and in response to stimuli. The spatiotemporal structure of waves can indicate the information they encode and the physiological processes that sustain them. Here, we investigate the stimulus-response relationships of traveling waves emerging in adaptive neural fields as a model of visual motion processing. Neural field equations model the activity of cortical tissue as a continuum excitable medium, and adaptive processes provide negative feedback, generating localized activity patterns...
April 12, 2024: Journal of Computational Neuroscience
https://read.qxmd.com/read/38607148/continuous-wave-pumped-monolayer-ws-2-lasing-for-photonic-barcoding
#34
JOURNAL ARTICLE
Haodong Cheng, Junyu Qu, Wangqi Mao, Shula Chen, Hongxing Dong
Micro/nano photonic barcoding has emerged as a promising technology for information security and anti-counterfeiting applications owing to its high security and robust tamper resistance. However, the practical application of conventional micro/nano photonic barcodes is constrained by limitations in encoding capacity and identification verification (e.g., broad emission bandwidth and the expense of pulsed lasers). Herein, we propose high-capacity photonic barcode labels by leveraging continuous-wave (CW) pumped monolayer tungsten disulfide (WS2 ) lasing...
March 30, 2024: Nanomaterials
https://read.qxmd.com/read/38606642/cardiac-mri-evaluation-of-aortic-biophysical-properties-in-paediatric-turner-syndrome
#35
JOURNAL ARTICLE
Somjate Suntratonpipat, Kiera Pajunen, Elizabeth Rosolowsky, Carolina A Escudero, Rose Girgis, Richard B Thompson, Joseph J Pagano, Edythe B Tham
BACKGROUND: Aortopathy in Turner syndrome is associated with aortic dilation, and the risk of dissection is increased when the aortic size index is ≥ 2-2.5 cm/m2 . We evaluated the aortic biophysical properties in paediatric Turner syndrome using cardiac MRI to determine their relationship to aortic size index. METHODS: Turner syndrome patients underwent cardiac MRI to evaluate ventricular function, aortic dimensions, and biophysical properties (aortic stiffness index, compliance, distensibility, pulse wave velocity, and aortic and left ventricular elastance)...
April 12, 2024: Cardiology in the Young
https://read.qxmd.com/read/38605306/glucose-control-during-pregnancy-in-patients-with-type-1-diabetes-correlates-with-fetal-hemodynamics-a-prospective-longitudinal-study
#36
JOURNAL ARTICLE
Patrik Simjak, Katerina Anderlova, Dagmar Smetanová, Michal Kršek, Miloš Mráz, Martin Haluzík
BACKGROUND: Maternal diabetes adversely affects fetal cardiovascular system development. Previous studies have reported that the fetuses of mothers with diabetes exhibit both structural and functional changes; nevertheless, prior studies have not examined the association between glucose control and fetal cardiac morphology and performance. Thus, the objective was to determine the association between fetal cardiac morphology and function and maternal glucose control in type 1 diabetes and to compare the differences in measured cardiac parameters between the fetuses of mothers with diabetes and healthy controls...
April 11, 2024: BMC Pregnancy and Childbirth
https://read.qxmd.com/read/38605163/emission-of-five-oam-dispersive-waves-in-dispersion-engineered-double-ring-core-fiber
#37
JOURNAL ARTICLE
Wenpu Geng, Yuxi Fang, Changjing Bao, Zhongqi Pan, Yang Yue
Beams carrying orbital angular momentum (OAM) have exhibited significant potential across various fields, such as metrology, image coding, and optical communications. High-performance broadband coherent OAM sources are critical to the operation of optical systems. The emission of dispersive waves facilitates the efficient transfer of energy to distant spectral domains while preserving the coherence among the generated frequency components. Light sources that maintain consistency over a wide range can increase the efficiency of optical communication systems and improve the measurement accuracy in imaging and metrology...
April 11, 2024: Scientific Reports
https://read.qxmd.com/read/38601660/association-between-six-different-types-of-anthropometric-indices-and-arterial-stiffness-measured-by-brachial-ankle-pulse-wave-velocity-in-hypertensive-chinese-adults
#38
JOURNAL ARTICLE
Feng Hu, Wei Zhou, Tao Wang, Chao Yu, Lingjuan Zhu, Huihui Bao, Xiaoshu Cheng
BACKGROUND: The associations of body fat parameters with arterial stiffness measured by brachial-ankle pulse wave velocity in hypertensive patients were scarce. METHODS: This cross-sectional study analyzed 4322 hypertensive adults. The correlations between the anthropometric indexes (body mass index [BMI], waist circumference, waist-tohip ratio [WHR], waist-to-height ratio [WHtR], a body shape index [ABSI], body round index [BRI]) and ba-PWV values were analyzed using multivariable linear regression model...
April 15, 2024: Heliyon
https://read.qxmd.com/read/38601023/repetitive-pulsed-wave-ultrasound-stimulation-suppresses-neural-activity-by-modulating-ambient-gaba-levels-via-effects-on-astrocytes
#39
JOURNAL ARTICLE
Tatsuya Mishima, Kenta Komano, Marie Tabaru, Takefumi Kofuji, Ayako Saito, Yoshikazu Ugawa, Yasuo Terao
Ultrasound is highly biopermeable and can non-invasively penetrate deep into the brain. Stimulation with patterned low-intensity ultrasound can induce sustained inhibition of neural activity in humans and animals, with potential implications for research and therapeutics. Although mechanosensitive channels are involved, the cellular and molecular mechanisms underlying neuromodulation by ultrasound remain unknown. To investigate the mechanism of action of ultrasound stimulation, we studied the effects of two types of patterned ultrasound on synaptic transmission and neural network activity using whole-cell recordings in primary cultured hippocampal cells...
2024: Frontiers in Cellular Neuroscience
https://read.qxmd.com/read/38600957/arterial-stiffness-assessment-in-coronary-microvascular-dysfunction-and-heart-failure-with-preserved-ejection-fraction-an-initial-report-from-the-wise-cvd-continuation-study
#40
JOURNAL ARTICLE
P Rezaeian, C L Shufelt, J Wei, C Pacheco, G Cook-Wiens, D Berman, B Tamarappoo, L E Thomson, M D Nelson, R D Anderson, J Petersen, E M Handberg, C J Pepine, C N Bairey Merz
BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) is the most common cardiac complication in patients with coronary microvascular dysfunction (CMD), yet its underlying pathways remain unclear. Aortic pulse-wave velocity (aPWV) is an indicator of large artery stiffness and a predictor for cardiovascular disease. However, aPWV in CMD and HFpEF is not well characterized and may provide understanding of disease progression. METHODS: Among participants without obstructive coronary artery disease, we evaluated 51 women with suspected CMD and 20 women and men with evidence of HFpEF...
May 2024: American heart journal plus: cardiology research and practice
keyword
keyword
67638
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.