keyword
https://read.qxmd.com/read/37036297/novel-use-of-an-irrigated-ablation-catheter-to-monitor-real-time-hemodynamics-during-ablation
#21
JOURNAL ARTICLE
Neal K Bhatia, Shahriar Iravanian, Namita Ravi, Soroosh Kiani, Michael S Lloyd, Stacy B Westerman, Faisal M Merchant, Mikhael F El-Chami, Azizul Hoque, Anand D Shah
INTRODUCTION: Hemodynamic decompensation during catheter ablation occurs due to prolonged procedure time and irrigant delivery directly into the cardiac chambers. Real-time hemodynamic monitoring of patients undergoing catheter ablation procedures may identify patients at risk of decompensation; we set out to assess the feasibility of a novel, real-time, intracardiac pressure monitoring system using a standard irrigated ablation catheter. METHODS: We studied 13 consecutive who underwent pressure measurement of the left atrium (LA) and left ventricle (LV) via transeptal access with a Swan Ganz (SG) catheter followed by two commercially available irrigated ablation catheters...
April 10, 2023: Journal of Cardiovascular Electrophysiology
https://read.qxmd.com/read/36999270/the-role-of-new-pulmonary-artery-wedge-pressure-formula-to-predict-diastolic-dysfunction-in-obstructive-sleep-apnea
#22
JOURNAL ARTICLE
Telly Kamelia, Lukman Hakim Makmun
BACKGROUND: Heart failure (HF) is a common condition with high morbidity and mortality  in  Obstructive Sleep Apnea (OSA), especially in obese patient. The causes of HF are often abnormal conduction pathways, pump filling and/or heart valves. Right heart catheterization using Swan-Ganz catheter remains the gold standard to determine pulmonary hemodynamics, but it is costly and invasive. Herein, we propose a new formula for non-invasive Pulmonary artery wedge pressure (PAWP) measurement using tissue Doppler echocardiography...
January 2023: Acta Medica Indonesiana
https://read.qxmd.com/read/36970297/catheter-directed-thrombolysis-as-an-emergent-intervention-for-failed-vacuum-thrombectomy-of-pulmonary-embolism
#23
Syed H Haq, Jordan Hinegardner-Hendricks, Cliff Cole, Amanda Laird, Sidra R Shah, Sandeep M Patel, William Cole
Acute pulmonary embolism [PE] in the setting of hemodynamic instability and right ventricular strain is a complex presentation and typically is associated with high mortality rates. Prompt recognition and early intervention are critical to the survival of these patient. In such cases, current guidelines recommend use of systemic thrombolytics, along with as needed cardiopulmonary support. If contraindications are present, mechanical thrombectomy is advised. However, guidelines poorly define the next steps in intervention if mechanical thrombectomy were to fail...
April 2023: Respirology Case Reports
https://read.qxmd.com/read/36960260/a-case-of-post-operative-jaundice-after-cardiac-surgery
#24
Fortune O Alabi, Christopher O Alabi, Brent Waldon, Fred C Umeh, George Palmer
Hyperbilirubinemia is a common gastrointestinal complication seen post-cardiac surgery. Here, we describe a case of a 72-year-old male with a past medical history of chronic obstructive pulmonary disease, chronic kidney disease (CKD), pulmonary hypertension, and valvular heart disease with severe aortic stenosis, severe mitral and tricuspid regurgitations who underwent elective aortic valve replacement (AVR), mitral valve replacement (MVR), and tricuspid valve (TV) repair; in addition, he required left thoracotomy for the repair of pulmonary artery perforation from a Swan-Ganz catheter that resulted in a large left pleural bleed...
February 2023: Curēus
https://read.qxmd.com/read/36918339/ex-situ-oxygenated-hypothermic-machine-perfusion-in-donation-after-circulatory-death-heart-transplantation-following-either-direct-procurement-or-in-situ-normothermic-regional-perfusion
#25
JOURNAL ARTICLE
Niels Moeslund, Imran A Ertugrul, Michiel A Hu, Frederik Flyvholm Dalsgaard, Lars Bo Ilkjaer, Pia Ryhammer, Michael Pedersen, Michiel E Erasmus, Hans Eiskjaer
BACKGROUND: Heart transplantation in donation after circulatory death (DCD) relies on warm perfusion using either in situ normothermic regional perfusion (NRP) or ex situ normothermic machine perfusion. In this study, we explore an alternative: oxygenated hypothermic machine perfusion (HMP) using a novel clinically applicable perfusion system, which is compared to NRP with static cold storage (SCS). METHODS: In a porcine model, a DCD setting was simulated, followed by either (1) NRP and SCS (2) NRP and HMP with the XVIVO Heart preservation system or (3) direct procurement (DPP) and HMP...
June 2023: Journal of Heart and Lung Transplantation
https://read.qxmd.com/read/36746901/secondary-migration-of-a-pre-existing-central-venous-catheter-due-to-a-swan-ganz-catheter-insertion-a-case-report
#26
Joonho Cho, Byung Hoon Yoo, Jihwan Park, Yun Hee Lim, In-Jung Jun, Kye-Min Kim
BACKGROUND: The entanglement of multiple central venous catheters is a rare and seriouscomplication. The Swan-Ganz catheter is a responsible for various cases. CASE: A 66-year-old male patient was under general anesthesia for a coronary artery bypassgraft surgery. As he had a pre-existing Perm catheter in the right subclavian vein, a SwanGanz catheter was inserted into the left internal jugular vein. Chest radiograph after catheterplacement revealed that the Perm catheter had migrated to the left brachiocephalic vein...
January 2023: Anesthesia and pain medicine
https://read.qxmd.com/read/36658027/intraoperative-changes-and-prognostic-implications-of-pulmonary-hypertension-in-patients-with-hypertrophic-obstructive-cardiomyopathy-undergoing-surgical-septal-myectomy
#27
JOURNAL ARTICLE
Xianying Liu, Kelly Ohlrich, Daniel Patrick McGrath, Fredrick Cobey, Nicole F Ruopp, Michael P Robich
OBJECTIVES: Patients with hypertrophic cardiomyopathy often have concomitant pulmonary hypertension, which has a negative prognostic effect in patients undergoing myectomy. Our objective was to investigate the effect of myectomy on pulmonary artery pressure obtained via Swan-Ganz catheter and characterize how changes in pulmonary artery systolic pressure may indicate outcomes in these patients. METHODS: We performed a single-center retrospective analysis of 271 patients with recordings of intraoperative pulmonary artery pressures during surgical myectomy...
October 6, 2022: Journal of Thoracic and Cardiovascular Surgery
https://read.qxmd.com/read/36640419/temporary-balloon-occlusion-test-can-overestimate-the-risk-of-acute-pulmonary-edema-after-transcatheter-atrial-septal-defect-closure
#28
JOURNAL ARTICLE
Koji Nakagawa, Teiji Akagi, Yoichi Takaya, Takashi Miki, Yasufumi Kijima, Rie Nakayama, Norihisa Toh, Nobuhiro Nishii, Kazufumi Nakamura, Hiroshi Morita, Hiroshi Ito
BACKGROUND: Atrial septal defect (ASD) closure can cause acute pulmonary edema. Before transcatheter closure is performed, temporary balloon occlusion test (BOT) is recommended in patients with left ventricular dysfunction to predict the risk of pulmonary edema. However, the accuracy of BOT has not been verified. This study aimed to compare hemodynamic differences between BOT and transcatheter closure. METHODS: A total of 42 patients with a single ASD over age 18 years who underwent BOT before transcatheter ASD closure between October 2010 and May 2020 were analyzed...
January 14, 2023: Catheterization and Cardiovascular Interventions
https://read.qxmd.com/read/36337385/pulmonary-artery-catheter-knot-in-a-liver-transplantation-a-rare-complication
#29
Felipe L Silva, José L U M Gomes, Walkiria W V Boas, Gabriela V de Freitas
The pulmonary artery catheter (PAC) measures hemodynamic parameters in real time, providing valuable data for the management of the critical patient. Nevertheless, its use is associated with several complications. Knot formation is a rare complication related to PAC insertion. A 51-year-old patient with complicated ethanolic liver cirrhosis underwent orthotopic liver transplantation. Invasive hemodynamic monitoring was performed using a Swan-Ganz pulmonary artery catheter (PAC) inserted through the right internal jugular vein...
October 2022: Saudi Journal of Anaesthesia
https://read.qxmd.com/read/36148201/combined-tricuspid-valve-repair-and-orthotopic-liver-transplantation-in-a-patient-with-severe-tricuspid-regurgitation-and-pulmonary-hypertension
#30
Nimit Kasliwal, Cheng Yang, Eric J Martinez, Robert F Hebeler, Saravanan Ramamoorthy
Severe pulmonary hypertension and severe tricuspid regurgitation are often considered strict contraindications for orthotopic liver transplantation. A combined approach of tricuspid repair and subsequent liver transplantation could provide a novel approach for patients with severe pulmonary hypertension and tricuspid regurgitation to undergo orthotopic liver transplantation. A 62-year-old male with a history of end-stage renal disease on hemodialysis, cirrhosis, and third-degree atrioventricular heart block status post single lead pacemaker insertion presented for an orthotopic liver transplant...
August 2022: Curēus
https://read.qxmd.com/read/36106602/effects-of-retroperitoneal-or-transperitoneal-pneumoperitoneum-on-inferior-vena-cava-hemodynamics-and-cardiopulmonary-function-a-prospective-real-time-comparison
#31
JOURNAL ARTICLE
Cheng Peng, Hao Shen, Senming Cao, Shengpan Wu, Qingbo Huang, Shichao Li, Hong Zhao Li, Xu Zhang, Baojun Wang, Jiangbei Cao, Xin Ma
OBJECTIVE: To evaluate the effects of CO2 pneumoperitoneum on venous hemodynamics and cardiopulmonary function during transperitoneal or retroperitoneal laparoscopic surgery. METHODS: A single institution prospective study. 43 patients with renal cell carcinoma undergoing retroperitoneal (22) or transperitoneal (21) laparoscopic partial nephrectomy were enrolled. Hemodynamic functions were monitored by Swan-Ganz and radial artery catheters. Transesophageal echocardiography was used to measure the diameter and blood flow of the inferior vena cava (IVC)...
September 15, 2022: Journal of Endourology
https://read.qxmd.com/read/36097922/-consensus-on-the-operation-of-pulmonary-artery-catheterization
#32
JOURNAL ARTICLE
(no author information available yet)
Right heart catheterization(RHC) is a technique of inserting a catheter into the right heart and pulmonary artery via a peripheral vein, to evaluate hemodynamics and oxygen dynamics. When Swan-Ganz catheter is used, it is called pulmonary artery catheterization (PAC). PAC plays an important role in the diagnosis and evaluation of pulmonary hypertension (PH), and hemodynamic assessment of critically ill patients. We developed this consensus to improve the overall quality of RHC operation, especially the PAC standardization in the diagnosis and evaluation of PH, thereby to promote the diagnosis and treatment of PH in China...
September 12, 2022: Chinese Journal of Tuberculosis and Respiratory Diseases
https://read.qxmd.com/read/36058343/right-heart-catheterization-timing-and-outcomes-of-cardiogenic-shock-analysis-from-the-national-readmission-database
#33
REVIEW
Ahmed M Elzanaty, Ahmed Maraey, Mahmoud Khalil, Hadeer Elsharnoby, Salik Nazir, George V Moukarbel
INTRODUCTION: Recent studies showed significant mortality benefit with right heart catheterization (RHC) use in cardiogenic (CS). The optimal timing of RHC in those patients is unknown owing to the lack of available data. METHODS: The Nationwide Readmission Database 2016-2018 was queried for hospitalizations with CS. We excluded patients presented with cardiac arrest or with a history of ventricular assist devices or heart transplantation. Complex samples multivariable logistic, cox, and linear regression models were used to determine the association between RHC timing in the index admission (<2 days [early RHC] vs ≥ 2 days [late RHC]) and in-hospital outcomes (mortality, acute kidney injury [AKI], mechanical circulatory device use [MCD], index length of stay [LOS], hospital charges), and all-cause 30-day readmissions...
September 1, 2022: Current Problems in Cardiology
https://read.qxmd.com/read/36054647/effects-of-remote-haemodynamic-guided-heart-failure-management-in-patients-with-different-subtypes-of-pulmonary-hypertension-insights-from-the-mems-hf-study
#34
JOURNAL ARTICLE
Birgit Assmus, Christiane E Angermann, Basil Alkhlout, Folkert W Asselbergs, Steffen Schnupp, Jasper J Brugts, Peter Nordbeck, Qian Zhou, Marie-Elena Brett, Greg Ginn, Philip B Adamson, Michael Böhm, Stephan Rosenkranz
INTRODUCTION: The CardioMEMS European Monitoring Study for Heart Failure (MEMS-HF) investigated safety and efficacy of pulmonary-artery-pressure (PAP)-guided remote patient management (RPM) in New York Heart Association (NYHA) Class III outpatients with at least one hospitalization for heart failure (HFH) during the previous 12 months. This pre-specified subgroup analysis investigated whether RPM effects depended on presence and subtype of pulmonary hypertension (PH). METHODS AND RESULTS: In 106/234 MEMS-HF participants, Swan-Ganz catheter tracings obtained during sensor implant were available for off-line manual analysis jointly performed by two experts...
August 23, 2022: European Journal of Heart Failure
https://read.qxmd.com/read/36004247/larger-pulmonary-artery-to-ascending-aorta-ratios-are-associated-with-decreased-survival-of-patients-undergoing-pulmonary-endarterectomy
#35
JOURNAL ARTICLE
Panja M Boehm, Stefan Schwarz, Jürgen Thanner, Cecilia Veraar, Mario Gerges, Christian Gerges, Irene Lang, Paul Apfaltrer, Helmut Prosch, Shahrokh Taghavi, Walter Klepetko, Hendrik Jan Ankersmit, Bernhard Moser
Objectives: The ratio of pulmonary artery (PA) and ascending aorta (AA) diameters has recently been shown to be a useful indicator for disease severity and predictor of outcome in patients with pulmonary hypertension and heart failure. This study aimed at evaluating the applicability of this ratio for perioperative risk assessment of patients with chronic thromboembolic pulmonary hypertension undergoing pulmonary endarterectomy. Methods: In this retrospective cohort study on 149 patients undergoing pulmonary endarterectomy between 2013 and 2020, the preoperative PA to AA ratio was analyzed on axial computed tomography...
June 2022: JTCVS open
https://read.qxmd.com/read/35982723/successful-percutaneous-embolization-of-an-intraoperative-swan-ganz-catheter-related-pulmonary-artery-injury
#36
Pranav Suri, Charles Kitley
Intraoperative pulmonary artery injury due to Swan Ganz catheterization is a rare but potentially life-threatening injury which demands rapid recognition and treatment. Subsequent pseudoaneurysm formation can occur if not immediately recognized, and percutaneous embolization is a viable option for treatment in most settings. We report a case of a 59-year-old female who underwent coronary artery bypass surgery and suffered an intraoperative Swan Ganz catheter-related injury which led to life threatening hemorrhage with subsequent pulmonary artery pseudoaneurysm formation that was successfully embolized...
October 2022: Radiology Case Reports
https://read.qxmd.com/read/35923377/performance-of-multiple-pretrained-bert-models-to-automate-and-accelerate-data-annotation-for-large-datasets
#37
JOURNAL ARTICLE
Ali S Tejani, Yee S Ng, Yin Xi, Julia R Fielding, Travis G Browning, Jesse C Rayan
Purpose: To develop and evaluate domain-specific and pretrained bidirectional encoder representations from transformers (BERT) models in a transfer learning task on varying training dataset sizes to annotate a larger overall dataset. Materials and Methods: The authors retrospectively reviewed 69 095 anonymized adult chest radiograph reports (reports dated April 2020-March 2021). From the overall cohort, 1004 reports were randomly selected and labeled for the presence or absence of each of the following devices: endotracheal tube (ETT), enterogastric tube (NGT, or Dobhoff tube), central venous catheter (CVC), and Swan-Ganz catheter (SGC)...
July 2022: Radiology. Artificial intelligence
https://read.qxmd.com/read/35809084/the-potential-of-arterial-pulse-wave-analysis-in-burn-resuscitation-a-pilot-in-vivo-study
#38
JOURNAL ARTICLE
Ghazal ArabiDarrehDor, Yi-Ming Kao, Mary A Oliver, Babita Parajuli, Bonnie C Carney, John W Keyloun, Lauren T Moffatt, Jeffrey W Shupp, Jin-Oh Hahn, David M Burmeister
While urinary output (UOP) remains the primary endpoint for titration of intravenous fluid resuscitation, it is an insufficient indicator of fluid responsiveness. Although advanced hemodynamic monitoring (including arterial pulse wave analysis (PWA)) is of recent interest, the validity of PWA-derived indices in burn resuscitation extremes has not been established. The goal of this paper is to test the hypothesis that PWA-derived cardiac output (CO) and stroke volume (SV) indices as well as pulse pressure variation (PPV) and systolic pressure variation (SPV) can play a complementary role to UOP in burn resuscitation...
July 9, 2022: Journal of Burn Care & Research: Official Publication of the American Burn Association
https://read.qxmd.com/read/35676916/bedside-ultrasound-to-assess-acute-central-venous-pressure-change-during-treatment-of-decompensated-heart-failure
#39
JOURNAL ARTICLE
Shumail Fatima, William Lambert, Mehdi Nouraie, John Pacella
Background: Accurate volume status assessment is crucial for the treatment of acute decompensated heart failure (ADHF). Volume status assessment by physical exam is often inaccurate, necessitating invasive measurement with right heart catheterization (RHC), which carries safety, pragmatic (scheduling, holding anticoagulants, etc.), and financial burdens. Therefore, a reliable, non-invasive, cost-effective alternative is desired. Previously, we developed an ultrasound (US) based technique to measure internal jugular vein (IJV) compliance during RHC which was used for single time point central venous pressure (CVP) predictions...
August 2022: IJC Heart & Vasculature
https://read.qxmd.com/read/35666028/continuous-cardiac-output-measured-with-a-swan-ganz-catheter-reacts-too-slowly-in-animal-experiments-with-sudden-circulatory-failure
#40
JOURNAL ARTICLE
Sigríður Olga Magnúsdóttir, Carsten Simonsen, Bodil Steen Rasmussen, Peter Enemark Lund, Benedict Kjaergaard
BACKGROUND: In many animal experiments, it is vital to detect sudden changes in cardiac output (CO). This porcine study compared CO that was measured with a Swan-Ganz pulmonary catheter with the gold standard (which was a transit-time flow probe around the pulmonary artery) during interventions that caused hemodynamic instability. METHODS: In one series, 7 pigs were exposed to sudden changes in CO. In another series, 9 pigs experienced more prolonged changes in CO...
September 2022: Animal Models and Experimental Medicine
keyword
keyword
65509
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.