https://read.qxmd.com/read/35804172/intra-and-inter-operator-concordance-of-the-resonance-frequency-analysis-a-cross-sectional-and-prospective-clinical-study
#21
JOURNAL ARTICLE
Raquel Antequera-Diaz, Maria-Pilar Quesada-García, Cristina Vallecillo, Marta Vallecillo-Rivas, Esther Muñoz-Soto, Maria-Victoria Olmedo-Gaya
OBJECTIVE: Resonance frequency analysis (RFA) provides an evaluation of implant stability over time. This analysis is a non-invasive, precise, and objective method. Several studies compare the RFA system with other devices. However, few investigations analyze repeatability and reproducibility between different operators. The aim of this study was to evaluate the intra- and inter-operator concordance of the Osstell® ISQ. MATERIAL AND METHODS: RFA measurements were performed with Osstell® ISQ in a total of 37 implants placed in 21 patients...
July 8, 2022: Clinical Oral Investigations
https://read.qxmd.com/read/35749706/effect-of-photobiomodulation-therapy-on-peri-implant-bone-healing-in-extra-short-implants-in-a-rabbit-model-a-pilot-study
#22
JOURNAL ARTICLE
Turan Emre Kuzu, Kübra Öztürk, Cem A Gürgan, Aslihan Üşümez, Arzu Yay, Özge Göktepe
Objective: To evaluate the effects of photobiomodulation therapy (PBMT) at distinct energy levels on peri-implant bone healing in extra-short implants in a experimental rabbit model. Background: The effect of PBMT on peri-implant bone healing in short implants remains unclear. This explored the effect of PBMT on extra-short implants in terms of bone-implant contact (BIC) length and rate, and implant stability quotient (ISQ). Methods: Fifteen white New Zealand rabbits were randomly divided into five groups. In all groups, extra-short implants (3...
June 2022: Photobiomodulation, photomedicine, and laser surgery
https://read.qxmd.com/read/35695945/assessment-of-absorbable-gelatin-sponge-for-maxillary-sinus-floor-elevation-versus-anorganic-bovine-bone-minerals-a-randomized-clinical-trial
#23
JOURNAL ARTICLE
Fatma Kandel, Mohamed Shawky, Amr Gibaly, Mohamed Mounir, Niveen Askar, Mohammed Atef
PURPOSE: The present study compared the absorbable gelatin sponge as a space-filling material versus anorganic bone bovine mineral (ABBM) in maxillary sinus augmentation with simultaneous endosseous dental implant placement. METHODS: Eighteen maxillary sinus floor elevation cases were randomly allocated into two groups. The first group received ABBM, while the second group received an absorbable gelatin sponge as a space-filling material. For both groups, CBCT scans were obtained immediately postoperatively and six months later to calculate the difference in sinus floor bone gain...
June 13, 2022: Oral and Maxillofacial Surgery
https://read.qxmd.com/read/35591407/primary-implant-stability-analysis-of-different-dental-implant-connections-and-designs-an-in-vitro-comparative-study
#24
JOURNAL ARTICLE
Perry Raz, Haya Meir, Shifra Levartovsky, Alon Sebaoun, Ilan Beitlitum
Primary implant stability can be evaluated at the time of placement by measuring the insertion torque (IT). However, another method to monitor implant stability over time is resonance frequency analysis (RFA). Our aim was to examine the effect of bone type, implant design, and implant length on implant primary stability as measured by IT and two RFA devices (Osstell and Penguin) in an in vitro model. Ninety-six implants were inserted by a surgical motor in an artificial bone material, resembling soft and dense bone...
April 23, 2022: Materials
https://read.qxmd.com/read/35580961/the-influence-of-implant-design-on-implant-stability-in-low-density-bone-under-guided-surgical-template-in-inexperienced-surgeons-a-pilot-randomized-controlled-clinical-trial-using-resonance-frequency-analysis
#25
RANDOMIZED CONTROLLED TRIAL
Pinmuk Supachaiyakit, Pravej Serichetaphongse, Wareeratn Chengprapakorn
INTRODUCTION: There are several factors that greatly influence implant stability with implant design being a paramount factor; however, few studies investigate its impact. AIM: To investigate the implant stability in relation to two different implant designs, a cylindrical shaped single-threaded design (CS/ST) and a tapered shaped double-threaded design (TS/DT) using resonance frequency analysis over the first 8 weeks after implantation. MATERIALS AND METHODS: Twenty-eight implants were randomly allocated using computer-generated random numbers into two groups and were placed as single tooth implant in the posterior arch in human jaw as specimens...
August 2022: Clinical Implant Dentistry and related Research
https://read.qxmd.com/read/35567659/evaluation-of-crestal-sinus-floor-elevations-using-versah-burs-with-simultaneous-implant-placement-at-residual-bone-height%C3%A2-%C3%A2-%C3%A2-2-0-_%C3%A2-%C3%A2-6-0%C3%A2-mm-a-prospective-clinical-study
#26
JOURNAL ARTICLE
Jenna Z Alhayati, Auday M Al-Anee
PURPOSE: To evaluate the efficacy of Versah drills in breaching the maxillary sinus floor while keeping the membrane intact, as well as measure the implant stability (primary stability at the time of implant placement by the osseous densification of the residual bone height (RBH) of ≥ 2.0 _ < 6.0 mm, and secondary stability after 6 months of osseous healing period). METHODS: This prospective clinical study, which included twenty crestal sinus floor elevations, was conducted on 17 patients (10 males and 7 females, ages 29 to 70 years)...
June 2023: Oral and Maxillofacial Surgery
https://read.qxmd.com/read/35432788/evaluation-of-bone-density-by-cone-beam-computed-tomography-and-its-relationship-with-primary-stability-of-dental-implants
#27
JOURNAL ARTICLE
Sina Haghanifar, Ali Malekzadeh Shafaroudi, Pegah Nasiri, Mostafa Mirzaie Amin, Javad Mehrani Sabet
Background: One of the critical factors determining the success of dental implants is primary stability. This study aimed to determine the density of jawbones in the implant candidate sites via cone-beam computed tomography (CBCT) and its correlation with the values obtained from resonance frequency analysis during surgery. Materials and Methods: In this descriptive-analytic study seventeen implant sites requiring implant placement were selected. Impressions were sent to the laboratory to construct a surgical guide via the stereolithographic method...
2022: Dental Research Journal
https://read.qxmd.com/read/35362702/-clinical-efficacy-of-hydroxyapatite-and-tricalcium-phosphate-modified-with-hyaluronic-acid-in-the-treatment-of-patients-with-periimplantitis
#28
JOURNAL ARTICLE
M M Garunov, L A Grigoriyants, A G Stepanov, S V Apresyan, D V Simonyan
THE AIM OF THE STUDY: Was to assess the effectiveness of the use of hydroxyapatite (HAP) and tricalcium phosphate (TCF) modified with hyaluronic acid in the treatment of patients with periimplantitis. MATERIALS AND METHODS: Clinical studies were conducted in 128 patients (44% male and 56% female) aged up to 55 years, who sought dental care with the main diagnosis of periimplant mucositis and periimplantitis. To compare the features of osseointegration of dental implants under bone remodeling three groups of patients were formed: one control and 2 main ones...
2022: Stomatologii︠a︡
https://read.qxmd.com/read/34930876/the-effect-of-bone-density-measured-by-cone-beam-computed-tomography-and-implant-dimensions-on-the-stability-of-dental-implants
#29
JOURNAL ARTICLE
Ali Tareef Noaman, Salwan Y Bede
The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ)...
December 20, 2021: Journal of Craniofacial Surgery
https://read.qxmd.com/read/34919618/primary-and-secondary-stability-of-extrashort-4-mm-implants-in-the-edentulous-mandible-preliminary-results-of-a-prospective-clinical-trial
#30
RANDOMIZED CONTROLLED TRIAL
Gabriela Panca Sabatini, Rangel Lidani, Tarla Thaynara Oliveira Dos Santos, Analucia Philippi, Luis André Mezzomo
PURPOSE: To compare the primary and secondary stability of conventional (≥ 8-mm) and extrashort (4-mm) implants in edentulous patients using different methods of assessment. MATERIALS AND METHODS: Patients underwent implant surgery and were randomly allocated into two groups: test, with two conventional implants in the anterior region and two extrashort (4-mm) implants in the posterior region; and control, with two conventional (≥ 8-mm) implants in the anterior region only...
November 2021: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/34639933/reliability-and-correlation-of-different-devices-for-the-evaluation-of-primary-implant-stability-an-in-vitro-study
#31
JOURNAL ARTICLE
Perry Raz, Haya Meir, Shifra Levartovsky, Maia Peleg, Alon Sebaoun, Ilan Beitlitum
Our aim was to analyze the correlation between the IT evaluated by a surgical motor and the primary implant stability (ISQ) measured by two RFA devices, Osstell and Penguin, in an in vitro model. This study examines the effect of bone type (soft or dense), implant length (13 mm or 8 mm), and implant design (CC: conical connection; IH: internal hexagon), on this correlation. Ninety-six implants were inserted using a surgical motor (IT) into two types of synthetic foam blocks. Initial measurements for both the peak IT and ISQ were recorded at the point when implant insertion was stopped by the surgical motor, and the final measurements were recorded when the implant was completely inserted into the synthetic blocks using only the RFA devices...
September 24, 2021: Materials
https://read.qxmd.com/read/34411221/primary-and-secondary-stability-of-implants-with-hydrophilic-surfaces-in-the-posterior-maxilla-a-split-mouth-randomized-controlled-clinical-trial
#32
RANDOMIZED CONTROLLED TRIAL
Pablo Pádua Barbosa, Thales Martins Cruvinel, Celso Eduardo Sakakura, Guilherme José Pimentel Lopes de Oliveira, Elizangela Cruvinel Zuza
PURPOSE: The aim of this split-mouth randomized clinical trial was to evaluate the primary and secondary stability of implants with hydrophilic surfaces in comparison to implants with conventional surfaces in the posterior region of the maxilla. MATERIALS AND METHODS: Twenty patients with a bilateral edentulous ridge in the posterior area of the maxilla randomly received implants with two types of surfaces: (1) implants with the surface modified by double acid-etching and sandblasting (DAS, n = 20); and (2) implants with the surface modified by double acid-etching and sandblasting, stored in 0...
July 2021: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/34312973/resonance-frequency-analysis-with-two-different-devices-after-conventional-implant-placement-with-ridge-preservation-a-prospective-pilot-cohort-study
#33
JOURNAL ARTICLE
Joost E I G Brouwers, Sharon Buis, Philip G de Groot, Bas de Laat, Jasper A Remijn
BACKGROUND: Primary and secondary implant stability is of high importance for survival and success of dental implants in the short and long term. Measurements of implant stability during healing provide the opportunity to monitor the course of the osseointegration process. PURPOSE: To compare implant stability quotient (ISQ) by resonance frequency analysis (RFA), recorded with two different devices after implant placement. MATERIALS AND METHODS: Patients with the need of single tooth extraction in posterior sites of the maxilla and the mandible were treated in a surgical center...
October 2021: Clinical Implant Dentistry and related Research
https://read.qxmd.com/read/34290171/measurement-of-dental-implant-stability-by-two-different-techniques
#34
JOURNAL ARTICLE
A Kocak-Buyukdere, G Kayabay
Objectives: To measure dental implant stability by two noninvasive methods which are vibration characteristics of the periodontium Periotest® and resonance frequency analysis Osstell. The objective of this comparative study was to assess the correlation of these 2 techniques in clinic. Materials and Methods: Implant stability of 54 clinically stable unloaded implants in 10 males and females (mean age: 52.05 ± 8.42) was measured in triplicate by Osstell and Periotest® . The measurements were taken first in the same day of the surgery and the second was 4 weeks later...
July 2021: Nigerian Journal of Clinical Practice
https://read.qxmd.com/read/34233364/relation-between-insertion-torque-and-implant-stability-quotient-a-clinical-study
#35
JOURNAL ARTICLE
João Paulo do Vale Souza, Clóvis Lamartine de Moraes Melo Neto, Lucas Tavares Piacenza, Emily Vivianne Freitas da Silva, André Luiz de Melo Moreno, Paulo Augusto Penitente, Juliana Lujan Brunetto, Daniela Micheline Dos Santos, Marcelo Coelho Goiato
OBJECTIVES:  This study aimed to assess the relation between the insertion torque and implant stability quotient (ISQ recorded immediately and 6 months after implant placement). MATERIALS AND METHODS:  Twenty-five patients over the age of 18 years were selected for this study. One implant was placed per patient after tooth extraction. The implant site needed 15 mm in height and 8 mm in width. All implants had the same size (11.5 × 3.75 mm) and brand (Hexagonal Morse cone, DSP Biomedical)...
July 7, 2021: European Journal of Dentistry
https://read.qxmd.com/read/33909730/one-year-results-assessing-the-performance-of-prosthetic-rehabilitations-in-the-posterior-maxilla-supported-by-4-mm-extrashort-implants-splinted-to-10-mm-implants-a-prospective-case-series
#36
JOURNAL ARTICLE
Rok Gašperšič, Michel Dard, Susy Linder, Čedomir Oblak
PURPOSE: The aim of this study was to evaluate the survival and success rates of oral rehabilitations in a shortened maxillary dental arch and expanded maxillary sinus with 4-mm extrashort implants splinted to longer ones. MATERIALS AND METHODS: One 10-mm and one/two extrashort 4-mm titanium-zirconium SLActive tissue-level dental implants were inserted into 11 patients with limited vertical bone availability due to an expanded maxillary sinus antrum. Immediately and 6 months after insertion, implant stability resonance frequency analysis (RFA) values were assessed with an Osstell device...
March 2021: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/33902551/the-early-loading-of-different-surface-modified-implants-a-randomized-clinical-trial
#37
JOURNAL ARTICLE
Kinga Körmöczi, György Komlós, Petra Papócsi, Ferenc Horváth, Árpád Joób-Fancsaly
BACKGROUND: Various surface treatment options have been adopted with the aim to improve osseointegration, reducing the overall treatment time. Implant stability of early loaded implants with different modified surfaces was compared in the present study. METHODS: Patients were selected from the Department of Oro-Maxillofacial Surgery and Stomatology at Semmelweis University. Patients randomly received SA (alumina sandblasted and acid-etched), NH (bioabsorbable apatite nanocoating) or SLA (large-grit sandblasted and acid-etched) surface implants...
April 26, 2021: BMC Oral Health
https://read.qxmd.com/read/33760051/comparison-of-reliability-of-three-resonance-frequency-analysis-devices-an-in-vitro-study
#38
JOURNAL ARTICLE
Burcu Diker, Nurettin Diker, Onjen Tak
The purpose of the present study was to investigate the intra-observer and inter-observer reliability of three resonance frequency analysis (RFA) devices and to compare the implant stability quotient (ISQ) values according to implant macro design and diameter in two different bone densities. A total of 64 implants (Neoss Proactive) of varying diameters (3.5 and 4.0 mm) and implant macro design (tapered and straight) were placed in two artificial bone blocks (the density of type 2 and 3). The implant primary stability was measured using Osstell IDx, Osstell Beacon and Penguin RFA...
March 24, 2021: Journal of Oral Implantology
https://read.qxmd.com/read/33494103/correlation-of-implant-stability-between-two-noninvasive-methods-using-submerged-and-nonsubmerged-healing-protocols-a-randomized-clinical-trial
#39
RANDOMIZED CONTROLLED TRIAL
Marwa Abdel AAl, Mahmoud El Far, Nora Mohamed Sheta, Ahmed Fayyad, Eman El Desouky, Nouran Abdel Nabi, Magdy Ibrahim
Various invasive and noninvasive methods have been used for measuring primary implant stability. Periotest damping device and resonance frequency analysis with the Osstell device have been classified as noninvasive methods. Primary and secondary implant stability measurements using both devices have given reproducible quantitative values. In this clinical randomized trial, a general correlation was evaluated between the implant stability recorded using both Osstell and Periotest devices on the day of implant installation and 3 months after healing for the submerged and nonsubmerged loading protocols...
December 1, 2020: Journal of Oral Implantology
https://read.qxmd.com/read/33378455/comparison-of-the-primary-stability-of-orthodontic-miniscrews-after-repeated-insertion-cycles
#40
JOURNAL ARTICLE
Felipe Nenen, Nicolás Garnica, Víctor Rojas, Rodrigo Oyonarte
OBJECTIVES: To compare the primary stability of miniscrews after repeated cycles of insertion through insertion torque (IT) measurements and resonance frequency analysis (RFA). MATERIALS AND METHODS: Sixty titanium miniscrews were divided into two groups according to the insertion protocol: one with predrilled sites and the other self-drilled into porcine iliac crest bone specimens. Each group had three cycles of reinsertion. After each insertion, the IT and RFA were measured...
December 30, 2020: Angle Orthodontist
keyword
keyword
63709
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.