keyword
https://read.qxmd.com/read/26651176/investigation-of-the-response-variability-of-ionization-chambers-for-the-standard-transfer-of-sir-spheres-%C3%A2
#21
JOURNAL ARTICLE
C Thiam, C Bobin, V Lourenço, V Chisté, M-N Amiot, X Mougeot, D Lacour, F Rigoulay, L Ferreux
The present paper addresses the calibration of well-type ionization chambers (ICs) used at LNE-LNHB as standard transfer instruments to calibrate hospitals in the case of SIR-Spheres(®)(90)Y resin microspheres (Sirtex, Australia). Developed for interventional oncology, this radiopharmaceutical is directly injected in the liver for cancer treatment via a selective internal radiation therapy. The present work was carried out in the framework of the European project "Metrology for molecular radiotherapy" (MetroMRT)...
March 2016: Applied Radiation and Isotopes
https://read.qxmd.com/read/26129385/we-g-bra-09-microsphere-brachytherapy-failure-mode-and-effects-analysis-in-a-dual-vendor-environment
#22
JOURNAL ARTICLE
K C Younge, C I Lee, M Feng, P Novelli, J M Moran, J I Prisciandaro
PURPOSE: To improve the safety and quality of a dual-vendor microsphere brachytherapy program with failure mode and effects analysis (FMEA). METHODS: A multidisciplinary team including physicists, dosimetrists, a radiation oncologist, an interventional radiologist, and radiation safety personnel performed an FMEA for our dual-vendor microsphere brachytherapy program employing SIR-Spheres (Sirtex Medical Limited, Australia) and Theraspheres (BTG, England). We developed a program process tree and step-by-step instructions which were used to generate a comprehensive list of failure modes...
June 2015: Medical Physics
https://read.qxmd.com/read/26127666/su-e-t-02-90y-microspheres-dosimetry-calculation-with-voxel-s-value-method-a-simple-use-in-the-clinic
#23
JOURNAL ARTICLE
F Maneru, A Otal, M Gracia, N Gallardo, J Olasolo, N Fuentemilla, L Bragado, M Martin-Albina, S Lozares, S Pellejero, S Miquelez, A Rubio
PURPOSE: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with (90)Y microspheres. Dose distributions are obtained and visualized over CT images. METHODS: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare...
June 2015: Medical Physics
https://read.qxmd.com/read/26116112/heterogeneity-of-microsphere-distribution-in-resected-liver-and-tumour-tissue-following-selective-intrahepatic-radiotherapy
#24
JOURNAL ARTICLE
Jonas Högberg, Magnus Rizell, Ragnar Hultborn, Johanna Svensson, Olof Henrikson, Johan Mölne, Peter Gjertsson, Peter Bernhardt
BACKGROUND: Selective arterial radioembolisation of liver tumours has increased, because of encouraging efficacy reports; however, therapeutic parameters used in external beam therapy are not applicable for understanding and predicting potential toxicity and efficacy, necessitating further studies of the physical and biological characteristics of radioembolisation. The aim was to characterise heterogeneity in the distribution of microspheres on a therapeutically relevant geometric scale considering the range of yttrium-90 ((90)Y) β-particles...
December 2014: EJNMMI Research
https://read.qxmd.com/read/25937772/transcatheter-embolization-therapy-in-liver-cancer-an-update-of-clinical-evidences
#25
REVIEW
Yì-Xiáng J Wáng, Thierry De Baere, Jean-Marc Idée, Sébastien Ballet
Transarterial chemoembolization (TACE) is a form of intra-arterial catheter-based chemotherapy that selectively delivers high doses of cytotoxic drug to the tumor bed combining with the effect of ischemic necrosis induced by arterial embolization. Chemoembolization and radioembolization are at the core of the treatment of liver hepatocellular carcinoma (HCC) patients who cannot receive potentially curative therapies such as transplantation, resection or percutaneous ablation. TACE for liver cancer has been proven to be useful in local tumor control, to prevent tumor progression, prolong patients' life and control patient symptoms...
April 2015: Chinese Journal of Cancer Research
https://read.qxmd.com/read/25579458/primary-standardization-of-sir-spheres-based-on-the-dissolution-of-the-90-y-labeled-resin-microspheres
#26
JOURNAL ARTICLE
V Lourenço, C Bobin, V Chisté, D Lacour, F Rigoulay, M Tapner, C Thiam, L Ferreux
The project "Metrology for molecular radiotherapy" is a collaborative European project initiated to bring together expertize in ionizing radiation metrology and nuclear medicine research. This project deals with the development of personalized dosimetry to individual patients who are undergoing molecular radiotherapy (also known as targeted radionuclide therapy). The general aim is to provide a metrological traceability to primary standards for individual dosimetry in the case of molecular radiotherapy. In particular, one objective is the standardization of (90)Y-labeled resin microspheres SIR-Spheres (Sirtex, Sydney, Australia) used for the treatment of liver cancer by radioembolization...
March 2015: Applied Radiation and Isotopes
https://read.qxmd.com/read/25487708/selective-internal-radiation-therapy-sirt-with-yttrium-90-resin-microspheres-plus-standard-systemic-chemotherapy-regimen-of-folfox-versus-folfox-alone-as-first-line-treatment-of-non-resectable-liver-metastases-from-colorectal-cancer-the-sirflox-study
#27
RANDOMIZED CONTROLLED TRIAL
Peter Gibbs, Val Gebski, Mark Van Buskirk, Kenneth Thurston, David N Cade, Guy A Van Hazel
BACKGROUND: In colorectal cancer (CRC), unresectable liver metastases are linked to poor prognosis. Systemic chemotherapy with regimens such as FOLFOX (combination of infusional 5-fluorouracil, leucovorin and oxaliplatin) is the standard first-line treatment. The SIRFLOX trial was designed to assess the efficacy and safety of combining FOLFOX-based chemotherapy with Selective Internal Radiation Therapy (SIRT or radioembolisation) using yttrium-90 resin microspheres (SIR-SpheresR; Sirtex Medical Limited, North Sydney, Australia)...
December 1, 2014: BMC Cancer
https://read.qxmd.com/read/25472660/radioembolisation-with-yttrium%C3%A2-90-microspheres-versus-sorafenib-for-treatment-of-advanced-hepatocellular-carcinoma-sarah-study-protocol-for-a-randomised-controlled-trial
#28
RANDOMIZED CONTROLLED TRIAL
Valérie Vilgrain, Mohamed Abdel-Rehim, Annie Sibert, Maxime Ronot, Rachida Lebtahi, Laurent Castéra, Gilles Chatellier
BACKGROUND: Untreated advanced hepatocellular carcinoma (HCC) is linked to poor prognosis. While sorafenib is the current recommended treatment for advanced HCC, radioembolisation (RE; also called selective internal radiation therapy or SIRT) with yttrium-90 microspheres has shown efficacy in cohort studies. However, there are no head-to-head trials comparing radiation therapy with yttrium-90 microspheres and sorafenib in advanced HCC. The SARAH trial has been designed to compare the efficacy and safety of sorafenib therapy and RE using yttrium-90 resin microspheres (SIR-Spheres™; Sirtex Medical Limited, North Sydney, Australia) in patients with advanced HCC...
December 3, 2014: Trials
https://read.qxmd.com/read/25369020/quantitative-and-qualitative-assessment-of-yttrium-90-pet-ct-imaging
#29
JOURNAL ARTICLE
Ali Asgar Attarwala, Flavia Molina-Duran, Karen-Anett Büsing, Stefan O Schönberg, Dale L Bailey, Kathy Willowson, Gerhard Glatting
Yttrium-90 is known to have a low positron emission decay of 32 ppm that may allow for personalized dosimetry of liver cancer therapy with (90)Y labeled microspheres. The aim of this work was to image and quantify (90)Y so that accurate predictions of the absorbed dose can be made. The measurements were performed within the QUEST study (University of Sydney, and Sirtex Medical, Australia). A NEMA IEC body phantom containing 6 fillable spheres (10-37 mm ∅) was used to measure the 90Y distribution with a Biograph mCT PET/CT (Siemens, Erlangen, Germany) with time-of-flight (TOF) acquisition...
2014: PloS One
https://read.qxmd.com/read/25011439/foxfire-protocol-an-open-label-randomised-phase-iii-trial-of-5-fluorouracil-oxaliplatin-and-folinic-acid-oxmdg-with-or-without-interventional-selective-internal-radiation-therapy-sirt-as-first-line-treatment-for-patients-with-unresectable-liver-only-or-liver
#30
RANDOMIZED CONTROLLED TRIAL
Susan J Dutton, Nicola Kenealy, Sharon B Love, Harpreet S Wasan, Ricky A Sharma
BACKGROUND: Colorectal cancer (CRC) is the second most common malignancy in Europe and a leading cause of cancer-related death. Almost 50% of patients with CRC develop liver metastases, which heralds a poor prognosis unless metastases can be downsized to surgical resection or ablation. The FOXFIRE trial examines the hypothesis that combining radiosensitising chemotherapy (OxMdG: oxaliplatin, 5-fluorouracil and folic acid) with Selective Internal Radiation Therapy (SIRT or radioembolisation) using yttrium-90 resin microspheres (SIR-Spheres®; Sirtex Medical Limited, North Sydney, Australia) as a first-line treatment for liver-dominant metastatic CRC will improve clinical outcomes when compared to OxMdG chemotherapy alone...
July 9, 2014: BMC Cancer
https://read.qxmd.com/read/23707371/comparison-of-the-survival-and-tolerability-of-radioembolization-in-elderly-vs-younger-patients-with-unresectable-hepatocellular-carcinoma
#31
MULTICENTER STUDY
Rita Golfieri, Josè Ignacio Bilbao, Livio Carpanese, Roberto Cianni, Daniele Gasparini, Samer Ezziddin, Philipp Marius Paprottka, Francesco Fiore, Alberta Cappelli, Macarena Rodriguez, Giuseppe Maria Ettorre, Adelchi Saltarelli, Onelio Geatti, Hojjat Ahmadzadehfar, Alexander R Haug, Francesco Izzo, Emanuela Giampalma, Bruno Sangro, Giuseppe Pizzi, Ermanno Notarianni, Alessandro Vit, Kai Wilhelm, Tobias F Jakobs, Secondo Lastoria
BACKGROUND & AIMS: The European Network on Radioembolization with Yttrium-90 resin microspheres study group (ENRY) conducted a retrospective study to evaluate the outcomes among elderly (≥ 70 years) and younger patients (<70 years) with unresectable hepatocellular carcinoma (HCC) who received radioembolization at 8 European centers. METHODS: Patients with confirmed diagnosis of unresectable HCC who either progressed following resection or locoregional treatment and/or who were considered poor candidates for chemoembolization were evaluated by a multidisciplinary team for radioembolization with (90)Y-resin microspheres (SIR-Spheres; Sirtex Medical)...
October 2013: Journal of Hepatology
https://read.qxmd.com/read/23354961/safety-of-repeated-yttrium-90-radioembolization
#32
JOURNAL ARTICLE
Marnix G E H Lam, John D Louie, Andrei H Iagaru, Michael L Goris, Daniel Y Sze
PURPOSE: Repeated radioembolization (RE) treatments carry theoretically higher risk of radiation-induced hepatic injury because of the liver's cumulative memory of previous exposure. We performed a retrospective safety analysis on patients who underwent repeated RE. METHODS: From 2004 to 2011, a total of 247 patients were treated by RE. Eight patients (5 men, 3 women, age range 51-71 years) underwent repeated treatment of a targeted territory, all with resin microspheres (SIR-Spheres; Sirtex, Lane Cove, Australia)...
October 2013: Cardiovascular and Interventional Radiology
https://read.qxmd.com/read/23079691/radiation-exposure-during-liver-surgery-after-treatment-with-90-y-microspheres-evaluated-with-computer-simulations-and-dosimeter-measurements
#33
JOURNAL ARTICLE
Jonas Högberg, Magnus Rizell, Ragnar Hultborn, Johanna Svensson, Olof Henrikson, Peter Gjertsson, Peter Bernhardt
PURPOSE: Two patients with liver tumours were planned for a combined treatment, including surgery with preceding injections of β(-) radiation emitting (90)Y microspheres (SIRTEX(®)). The aim of this paper is to present a method of pre-surgical computer simulations of the absorbed dose rate on the surface of tumour tissue, combined with measurements of the actual absorbed dose rate on resected tissue, in order to estimate the absorbed dose to a surgeon's fingers during such surgery procedures...
December 2012: Journal of Radiological Protection: Official Journal of the Society for Radiological Protection
https://read.qxmd.com/read/21939859/radioembolization-for-primary-and-metastatic-liver-cancer
#34
REVIEW
Khairuddin Memon, Robert J Lewandowski, Laura Kulik, Ahsun Riaz, Mary F Mulcahy, Riad Salem
The incidence of hepatocellular carcinoma is increasing. Most patients present beyond potentially curative options and are usually affected by underlying cirrhosis. In this scenario, transarterial therapies, such as radioembolization, are rapidly gaining acceptance as a potential therapy for hepatocellular carcinoma and liver metastases. Radioembolization is a catheter-based liver-directed therapy that involves the injection of micron-sized embolic particles loaded with a radioisotope by use of percutaneous transarterial techniques...
October 2011: Seminars in Radiation Oncology
https://read.qxmd.com/read/21494856/eanm-procedure-guideline-for-the-treatment-of-liver-cancer-and-liver-metastases-with-intra-arterial-radioactive-compounds
#35
JOURNAL ARTICLE
Francesco Giammarile, Lisa Bodei, Carlo Chiesa, Glenn Flux, Flavio Forrer, Françoise Kraeber-Bodere, Boudewijn Brans, Bieke Lambert, Mark Konijnenberg, Françoise Borson-Chazot, Jan Tennvall, Markus Luster
Primary liver cancers (i.e. hepatocellular carcinoma or cholangiocarcinoma) are worldwide some of the most frequent cancers, with rapidly fatal liver failure in a large majority of patients. Curative therapy consists of surgery (i.e. resection or liver transplantation), but only 10-20% of patients are candidates for this. In other patients, a variety of palliative treatments can be given, such as chemoembolization, radiofrequency ablation or recently introduced tyrosine kinase inhibitors, e.g. sorafenib. Colorectal cancer is the second most lethal cancer in Europe and liver metastases are prevalent either at diagnosis or in follow-up...
July 2011: European Journal of Nuclear Medicine and Molecular Imaging
https://read.qxmd.com/read/21461737/the-prognostic-value-of-functional-tumor-volume-and-total-lesion-glycolysis-in-patients-with-colorectal-cancer-liver-metastases-undergoing-90y-selective-internal-radiation-therapy-plus-chemotherapy
#36
JOURNAL ARTICLE
Seza A Gulec, Rekha R Suthar, Tushar C Barot, Kenneth Pennington
PURPOSE: Functional tumor volume (FTV) and total lesion glycolysis (TLG) are measures of metabolic activity of tumors determined by fluorodeoxyglucose (FDG) positron emission tomography (PET)/CT images. These parameters could potentially have clinical value in response to treatment evaluation and disease prognostication. The objectives of this study were to investigate the relationship between functional tumor parameters (FTV and TLG) and clinical outcomes in patients with colorectal cancer liver metastases (CRCLM) undergoing (90)Y-resin microsphere selective internal radiation therapy (SIRT) (SIR-Spheres®, Sirtex Medical Limited, Lane Cove, NSW, Australia)...
July 2011: European Journal of Nuclear Medicine and Molecular Imaging
https://read.qxmd.com/read/20693154/a-serious-complication-of-selected-internal-radiation-therapy-case-report-and-literature-review
#37
REVIEW
Katrin M Sjoquist, David Goldstein, Lourens Bester
The use of selective internal radiation therapy (SIRT) with SIR-Spheres(R) (Sirtex, Sydney, Australia) is increasingly recognized as a potential therapeutic modality of primary and secondary malignant liver tumors. A number of treatment-related complications have been described despite technical expertise and detailed pretreatment investigations to assess suitability. We describe a case of gastric ulceration from nontargeted deposition of SIR-spheres(R) in the gastric mucosa with life-threatening consequences...
2010: Oncologist
https://read.qxmd.com/read/20180183/radioembolization-for-the-treatment-of-unresectable-liver-cancer-initial-experience-at-a-single-center
#38
JOURNAL ARTICLE
Bora Peynircioğlu, Barbaros Cil, Fani Bozkurt, Ece Aydemir, Omer Uğur, Ferhun Balkanci
PURPOSE: Radioembolization with yttrium-90 microsphere (Y-90) therapy with SIR-Spheres (Sirtex Medical, Lane Cove, Australia) was approved by the Turkish Ministry of Health in April 2008. In this study, we present the preliminary experience at a tertiary care center with early follow-up results of Y-90 therapy, as well as a review of the related literature. MATERIALS AND METHODS: Complete evaluation for radioembolization was performed in 10 patients (8 males, 2 females; mean age, 52...
March 2010: Diagnostic and Interventional Radiology: Official Journal of the Turkish Society of Radiology
https://read.qxmd.com/read/19694577/y-90-microsphere-therapy-prevention-of-adverse-events
#39
JOURNAL ARTICLE
Cheryl C Schultz, Janice Campbell, Donovan Bakalyar, Michele Beauvais, Wenzheng Feng, Michael Savin
OBJECTIVE: Thirty-three (33) events that were inconsistent with intended treatment for 471 Y-90 microsphere deliveries were analyzed from 2001 to 2007. METHOD: Each occurrence was categorized, based on root-cause analysis, as a device/product defect and/or operator error event. Events were further categorized, if there was an adverse outcome, as spill/leak, termination, recatheterization, dose deviation, and/or a regulatory medical event. RESULTS: Of 264 Y-90 Therasphere (MDS Nordion, Ottawa, Ontario, Canada) treatments, 15 events were reported (5...
August 2009: Cancer Biotherapy & Radiopharmaceuticals
https://read.qxmd.com/read/17359531/safety-and-efficacy-of-y-90-microsphere-treatment-in-patients-with-primary-and-metastatic-liver-cancer-the-tumor-selectivity-of-the-treatment-as-a-function-of-tumor-to-liver-flow-ratio
#40
JOURNAL ARTICLE
Seza A Gulec, Geraldine Mesoloras, William A Dezarn, Patrick McNeillie, Andrew S Kennedy
BACKGROUND: Treatment records and follow-up data on 40 patients with primary and metastatic liver malignancies who underwent a single whole-liver treatment with Y-90 resin microspheres (SIR-Spheres Sirtex Medical, Lake Forest, IL) were retrospectively reviewed. The objective of the study was to evaluate the anatomic and physiologic determinants of radiation dose distribution, and the dose response of tumor and liver toxicity in patients with liver malignancies who underwent hepatic arterial Y-90 resin microsphere treatment...
2007: Journal of Translational Medicine
keyword
keyword
55053
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.