Shannon W Hill, Christopher R Chapman, Samer Adeeb, Kajsa Duke, Lauren Beaupre, Martin J Bouliane
BACKGROUND: The Nice knot is a bulky double-stranded knot. Biomechanical data supporting its use as well as the number of half hitches required to ensure knot security is lacking. MATERIALS AND METHODS: Nice knots with, one, two, or three half-hitches were compared with the surgeon's and Tennessee slider knots with three half hitches. Each knot was tied 10 times around a fixed diameter using four different sutures: FiberWire (Arthrex, Naples, FL), Ultrabraid (Smith and Nephew, Andover, MA), Hi-Fi (ConMed Linvatec, Largo, FL) and Force Fiber (Teleflex Medical OEM, Gurnee, IL)...
January 2016: International Journal of Shoulder Surgery
Myung-Sun Kim, Dong Whan Kim, Young Eun Choi, Larry Bachman, Sae Hoon Kim
PURPOSE: To determine the effect of tendon thickness on the needle penetration ability of four different designs of antegrade suture passers. MATERIALS AND METHODS: Four antegrade suture passers were tested: (a) ExpresSew II (Depuy Mitek Inc., Raynham, MA), (b) Arthrex Scorpion (Arthrex, Naples, FL), (c) Concept (Linvatec Corp, Largo, FL), and (d) ElitePass (Smith and Nephew Endoscopy, Andover, MA). Bovine tendons were divided into five thickness groups: 3, 5, 7, 9 and 11 mm...
April 2015: International Journal of Shoulder Surgery
Wei-Ren Su, Florence Y Ling, Chih-Kai Hong, Chih-Hsun Chang, Cheng-Li Lin, I-Ming Jou
UNLABELLED: There are several options for LHB tenodesis; yet, there is no standard of care. This technical note describes an extramedullary all-suture anchor technique for LHB tenodesis that is similar to the extramedullary cortical button technique. The LHB tenodesis is performed by using the Y-Knot (1.3-mm; ConMed Linvatec, Largo, FL).The biceps tenotomy is completed arthroscopically, and a standard subpectoral approach is used for the tenodesis. A reamer is first used to drill through the anterior cortex of the humerus; subsequently, a 1...
February 2015: Knee Surgery, Sports Traumatology, Arthroscopy: Official Journal of the ESSKA
Tim Dwyer, Thomas L Willett, Andrew P Dold, Massimo Petrera, David Wasserstein, Danny B Whelan, John S Theodoropoulos
PURPOSE: The purpose of this study was to evaluate the biomechanical behavior of an all-suture glenoid anchor in comparison with a more conventional screw-in glenoid anchor, with regard to maximum load to failure and tensile displacement. METHODS: All mechanical testing was performed using an Instron ElectroPuls E1000 mechanical machine, with a 10 N pre-load and displacement rate of 10 mm/min. Force-displacement curves were generated, with calculation of maximum load, maximum displacement, displacement at 50 N and stiffness...
February 2016: Knee Surgery, Sports Traumatology, Arthroscopy: Official Journal of the ESSKA
M H Baums, Ch Sachs, T Kostuj, K Schmidt-Horlohé, W Schultz, H-M Klinger
PURPOSE: This laboratory study aimed to evaluate the loop security, knot security, cyclic loading resistance and load-to-failure rate of three different knot types with establishing a new experimental set-up. Additionally, the mode of failure of each knot was evaluated. METHODS: With the use of nonabsorbable, braided polyethylene sutures, USP size No. 2 [Hi-Fi(®); ConMed Linvatec], the arthroscopic knot types Dines, SMC as well as the surgeon's knot were tested using a material testing machine...
October 13, 2013: Knee Surgery, Sports Traumatology, Arthroscopy: Official Journal of the ESSKA
Jong Hun Lee, Jun Hyung Park
BACKGROUND: Ultrasound-aided fixation is a recently developed alternative method of treatment of zygomatico-maxillary (ZM) fracture, and it can resolve the problems of excessive torsion force and subsequent fractures of screws. We conducted this study to evaluate the clinical usefulness of ultrasound-aided fixation as compared with the conventional fixation method using a drill and an expander in patients with ZM fracture. METHODS: We conducted a retrospective study in 35 patients with ZM fracture who had been treated at our hospital during a period ranging from March of 2008 to December of 2010...
July 2013: Archives of Plastic Surgery
Adriana Martinez, Yung Han, Zeeshan M Sardar, Lorne Beckman, Thomas Steffen, Bruce S Miller, Paul A Martineau
PURPOSE: To examine the risk of glove tears associated with arthroscopic knot tying using 4 commonly used high-tensile strength sutures and 2 different types of gloves. METHODS: We analyzed 2 different surgical latex glove types (0.24-mm-thick powder-free and 0.32-mm-thick powdered) for perforation after arthroscopic knot tying with 4 different high-tensile strength sutures: Hi-Fi (ConMed Linvatec, Largo, FL), Ultrabraid (Smith & Nephew, Memphis, TN), FiberWire (Arthrex, Naples, FL), and Orthocord (DePuy Mitek, Raynham, MA)...
September 2013: Arthroscopy: the Journal of Arthroscopic & related Surgery
Justin R Knight, Marissa Daniels, William Robertson
Exertional compartment syndrome of the leg is a condition that can cause chronic debilitating pain in active persons during a variety of aerobic activities. Nonoperative treatments using stretching protocols and activity modifications are often unsuccessful, and thus several operative strategies have been used to treat this condition. A novel technique for endoscopically assisted fasciotomy for chronic exertional compartment syndrome is described. By use of a small laterally based incision and an arthroscope, polydioxanone sutures are passed percutaneously along the anterior and lateral compartments with the Spectrum suture-shuttling device (ConMed Linvatec, Largo, FL)...
May 2013: Arthroscopy Techniques
F Alan Barber, Morley A Herbert
PURPOSE: The purpose of this study was to evaluate the biomechanical and design characteristics of newer suture anchors under cyclic loading. METHODS: Suture anchors were tested in fresh porcine cortical and cancellous bone by cyclic loading (10 to 100 N for 200 cycles) followed by destructive testing parallel to the insertion axis at 12.5 mm per second. End points included ultimate failure load, displacement at 100 and 200 cycles, failure mode, and stiffness. Anchors tested included ReelX (Stryker Endoscopy, San Jose, CA); Footprint Ultra PK (4...
May 2013: Arthroscopy: the Journal of Arthroscopic & related Surgery
Pablo Eduardo Gelber, Juan Ignacio Erquicia, Xavier Pelfort, Marc Tey, Juan Carlos Monllau
A 16-year-old male who had undergone 6 months before an anterior cruciate ligament (ACL) reconstruction with an autologous hamstring graft fixed with a suspensory fixation device (XoButton device; ConMed Linvatec, Largo, FL), complained of a slightly painful mass in the distal posterolateral aspect of the thigh. The knee was otherwise stable. A 79 × 60 × 17 mm multilobulated tumor surrounding the implant device was observed in magnetic resonance images. The revision arthroscopy showed an intact ACL graft...
December 2013: Journal of Knee Surgery
Yee Han Dave Lee, John Nyland, Robert Burden, David N M Caborn
PURPOSE: To compare biomechanical fixation and gapping characteristics of a new all-inside meniscus repair method for radial meniscus lesion repair versus conventional inside-out suture repair under submaximal cyclic loading and load-to-failure test conditions. METHODS: Fresh-frozen porcine tibiae with attached lateral menisci and joint capsules were harvested and stored for 48 hours at -20°C. After thawing for 12 hours, equivalent-size healthy specimens were randomly assigned to 2 groups of 8 specimens each...
December 2012: Arthroscopy: the Journal of Arthroscopic & related Surgery
Dirk A Ottink, Stefan W A M van Zutphen, Ron van Doorn, Diederick B Wouters
PURPOSE: Previous experience has revealed excellent outcomes when using the Meniscus Arrow (Conmed Linvatec Ltd., Tampere, Finland) bioabsorable meniscal repair system for the fixation of small fracture fragments. This study describes the results of the fixation of Mason type 2 radial head fractures with these Arrows in a prospective series of 21 patients. METHODS: Between 2006 and 2010, a total of 21 patients were treated with Meniscus Arrows for the fixation of Mason type 2 fractures of the radial head during an open procedure...
January 2014: Knee Surgery, Sports Traumatology, Arthroscopy: Official Journal of the ESSKA
F Alan Barber, Morley A Herbert, Eric D Bava, Otis R Drew
PURPOSE: To evaluate the biomechanical characteristics of recently introduced ultrahigh-molecular-weight polyethylene suture-based, self-adjusting meniscal repair devices. METHODS: Updating a prior study published in 2009, we made vertical longitudinal cuts 3 mm from the periphery in fresh-frozen adult human menisci to simulate a bucket-handle meniscus tear. Each tear was then repaired by a single repair technique in 10 meniscus specimens. Group 1 menisci were repaired with a vertical mattress suture of No...
June 2012: Arthroscopy: the Journal of Arthroscopic & related Surgery
Onur Hapa, F Alan Barber, Ganim Süner, Raif Özden, Serkan Davul, Ergun Bozdağ, Emin Sünbüloğlu
PURPOSE: To biomechanically compare anterior cruciate ligament (ACL) tibial bony avulsion fixation by suture anchors, EndoButtons (Smith & Nephew, Andover, MA), and high-strength sutures subjected to cyclic loading. METHODS: Type III tibial eminence fractures were created in 49 ovine knees, and 7 different types of repairs were performed. Each repair group contained 7 specimens. The repair groups were as follows: No. 2 FiberWire (Arthrex, Naples, FL); No. 2 UltraBraid (Smith & Nephew); No...
May 2012: Arthroscopy: the Journal of Arthroscopic & related Surgery
Matthias F Pietschmann, Patrick Sadoghi, Eva Häuser, Andreas Scharpf, Mehmet F Gülecyüz, Christian Schröder, Volkmar Jansson, Peter E Müller
PURPOSE: The purpose was to evaluate whether the knot security of sliding and nonsliding knots with different sutures is influenced by dry or wet conditions. METHODS: We tested 5 suture materials, all of them US Pharmacopeia No. 2: PDS (polydioxanone) II (Ethicon, Somerville, NJ), Ethibond (Ethicon), and 3 ultrahigh-molecular weight polyethylene (UHMWPE) sutures-FiberWire (Arthrex, Naples, FL), Orthocord (DePuy Mitek, Raynham, MA), and Herculine (Linvatec, Largo, FL)...
December 2011: Arthroscopy: the Journal of Arthroscopic & related Surgery
Min Jung Park, Jason E Hsu, Carl Harper, Brian J Sennett, G Russell Huffman
PURPOSE: This study investigates factors associated with failure and reoperation after glenoid labrum repair. METHODS: We studied a nonconcurrent cohort of consecutive patients undergoing arthroscopic superior labrum repair at a single institution by 2 fellowship-trained surgeons over a 10-year period. RESULTS: There were 348 patients included in this study with a mean age of 33.4 years (95% confidence interval [CI], 32.1 to 35.9) and a mean clinical follow-up of 12...
October 2011: Arthroscopy: the Journal of Arthroscopic & related Surgery
Fumito Komatsu, Masato Takao, Ken Innami, Wataru Miyamoto, Takashi Matsushita
PURPOSE: The purpose of this study was to determine the clinical results of deep-fascial medial and lateral portals in performing endoscopic surgery for plantar fasciitis. METHODS: In 10 feet in 8 patients who were treated conservatively for more than 6 months with failure to relieve their symptoms, endoscopic surgery was performed. After the patient was placed in the supine position, a medial portal was made 5 mm deep to the plantar fascia and 10 mm anterior to its origin on the calcaneus under fluoroscopy...
August 2011: Arthroscopy: the Journal of Arthroscopic & related Surgery
F Alan Barber, Morley A Herbert, Onur Hapa, Jay H Rapley, Cameron A K Barber, James A Bynum, Scott A Hrnack
PURPOSE: To evaluate the biomechanical and design characteristics of newer suture anchors. METHODS: Suture anchors were tested in fresh porcine metaphyseal cortex and cancellous troughs by use of an established protocol. A mechanical testing machine applied tensile loads parallel to the axis of insertion at 12.5 mm/s until failure, and mean anchor failure strengths were calculated. The mode of failure was recorded. Rotator cuff anchors tested included the Doubleplay and Opus SpeedScrew (ArthroCare Sports Medicine, Sunnyvale, CA); PEEK Intraline and PEEK Zip (Stryker, San Jose, CA); Paladin, SuperRevo FT, and CrossFT (ConMed Linvatec, Largo, FL); Piton (Tornier, Warsaw, IN); Ti Screw, ALLthread PEEK, LactoScrew, ALLthread Ti, and ALLthread PEEK knotless (Biomet Sports Medicine, Warsaw, IN)...
July 2011: Arthroscopy: the Journal of Arthroscopic & related Surgery
Pablo Eduardo Gelber, Juan Erquicia, Ferrán Abat, Raúl Torres, Xavier Pelfort, Alfonso Rodriguez-Baeza, Xavier Alomar, Juan Carlos Monllau
PURPOSE: To compare drilling the femoral tunnel with an offset aimer and BullsEye guide (ConMed Linvatec, Largo, FL) to perform an anatomic single-bundle reconstruction of the anterior cruciate ligament (ACL) through the anteromedial portal. METHODS: Seven matched pairs of cadaveric knees were studied. The intent was to drill the femoral tunnel anatomically in all cases. In group A the femoral tunnel was drilled arthroscopically with an offset aimer. In group B the femoral tunnel was drilled arthroscopically with the BullsEye guide...
June 2011: Arthroscopy: the Journal of Arthroscopic & related Surgery
F Alan Barber, Onur Hapa, James A Bynum
PURPOSE: To compare isolated medial-row with isolated lateral-row anchor performance by use of cyclic loading followed by destructive testing in an in vitro cadaveric model. METHODS: Using 16 human cadaveric humeri without tendons, we rotated 4 medial-row (Bio-Corkscrew FT [Arthrex, Naples FL], CrossFT PK [ConMed Linvatec, Largo, FL], TwinFix PK FT [Smith & Nephew Endoscopy, Andover, MA], and Healix PK [DePuy Mitek, Raynham, MA]) and 4 lateral-row (PopLok PK [ConMed Linvatec], PEEK [polyetheretherketone] PushLock [Arthrex], Footprint PEEK [Smith & Nephew Endoscopy], and Versalok [DePuy Mitek]) anchors among different medial (articular cartilage edge) and lateral greater tuberosity sites (anterior, central, posterior)...
September 2010: Arthroscopy: the Journal of Arthroscopic & related Surgery
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"