keyword
https://read.qxmd.com/read/36742071/quantification-of-paravalvular-leaks-associated-with-tavi-implants-using-4d-mri-in-an-aortic-root-phantom-made-possible-by-the-use-of-3d-printing
#21
JOURNAL ARTICLE
Philipp Aigner, Eleonora Sella Bart, Sebastiano Panfili, Tito Körner, Markus Mach, Martin Andreas, Markus Königshofer, Simone Saitta, Alberto Redaelli, Albrecht Schmid, Francesco Moscato
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound...
2023: Frontiers in Cardiovascular Medicine
https://read.qxmd.com/read/36542648/impact-of-implantation-technique-on-conduction-disturbances-for-tavr-with-the-self-expanding-portico-navitor-valve
#22
JOURNAL ARTICLE
Xi Wang, Ivan Wong, Vilhelmas Bajoras, Maarten Vanhaverbeke, Philippe Nuyens, Gintautas Bieliauskas, Troels Højsgaard Jørgensen, Mao Chen, Ole De Backer, Lars Sondergaard
BACKGROUND: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. AIMS: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/NavitorTM transcatheter heart valve (THV; Abbott). METHODS: A TAVR-population treated with Portico/NavitorTM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system...
December 21, 2022: Catheterization and Cardiovascular Interventions
https://read.qxmd.com/read/36484239/real-world-multiple-comparison-of-transcatheter-aortic-valves-insights-from-the-multicenter-observant-ii-study
#23
MULTICENTER STUDY
Giuliano Costa, Marco Barbanti, Stefano Rosato, Fulvia Seccareccia, Giuseppe Tarantini, Massimo Fineschi, Stefano Salizzoni, Roberto Valvo, Corrado Tamburino, Fausto Biancari, Giovanni Baglio, Gennaro Santoro, Massimo Baiocchi, Paola D'Errigo
BACKGROUND: Head-to-head comparisons of devices for transcatheter aortic valve implantation (TAVI) are mostly limited to 2-arm studies so far. The aim of this study was to compare simultaneously outcomes of the most used, second- and third-generation transcatheter aortic valves in a real-world population. METHODS: A total of 2728 patients undergoing TAVI with different second- and third-generation devices, and enrolled in the multicenter, prospective OBSERVANT II study (Observational Study of Effectiveness of TAVI With New Generation Devices for Severe Aortic Stenosis Treatment) from December 2016 to September 2018 were compared according to the transcatheter aortic valve received...
December 2022: Circulation. Cardiovascular Interventions
https://read.qxmd.com/read/36431866/visual-and-physical-degradation-of-the-black-and-white-mosaic-of-a-roman-domus-under-palazzo-valentini-in-rome-a-preliminary-study
#24
JOURNAL ARTICLE
Claudia Colantonio, Paola Baldassarri, Pasquale Avino, Maria Luisa Astolfi, Giovanni Visco
Palazzo Valentini, the institutional head office of Città Metropolitana di Roma Capitale, stands in in a crucial position in the Roman archaeological and urban contexts, exactly between the Fora valley, Quirinal Hill slopes, and Campus Martius. It stands on a second-century A.D. complex to which belong, between other archeological remains, two richly decorated aristocratic domus. One of these buildings, the domus A , presents an outward porticoed room with a fourth-century AD central impluvium (open air part of the atrium designed to carry away rainwater) with a black/white tiled mosaic pavement, the preservation status of which is compromised by an incoherent degradation product that has caused gradual detachment of the mosaic tiles...
November 11, 2022: Molecules: a Journal of Synthetic Chemistry and Natural Product Chemistry
https://read.qxmd.com/read/36398043/successful-closure-of-the-ventricular-septal-defect-a-rare-complication-after-transcatheter-aortic-valve-replacement
#25
Saadet Demirtas Inci, Murat Tulmaç, Cagatay Tunca, Tolgahan Efe, Hakan Güllü
In this report, we present a patient with ventricular septal defect (VSD) that was detected at follow-up one month after transcatheter aortic valve implantation (TAVI) and successfully closed percutaneously. Before the procedure, a 29 mm Portico self-expanding aortic valve prosthesis was placed in the heavy calcific aortic valve position, and then the balloon was dilated due to aortic insufficiency and excellent results were obtained. One month after TAVI, the patient complained of shortness of breath at rest, and on physical examination a pansystolic murmur was detected...
2022: Journal of Cardiovascular and Thoracic Research
https://read.qxmd.com/read/36344392/30-day-outcomes-with-the-portico-transcatheter-heart-valve-insights-from-a-multi-centre-australian-observational-study
#26
JOURNAL ARTICLE
Anthony C Camuglia, Christopher Mw Cole, Nicholas Boyne, Sam M Hayman, Stephen V Cox, Peter T Moore, Jerrett K Lau, Sinny Delacroix, Anna Emilie Williamson, MyNgan Duong, Nisha Schwarz, Joseph K Montarello, Stephen G Worthley
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established therapy for the treatment of aortic valve disease in appropriately selected patients. Previous studies using the self-expanding Portico transcatheter heart valve (THV), (Abbott Structural Heart, St Paul, MN, USA) have demonstrated the technical feasibility of this system albeit in the hands of relatively inexperienced Portico users. The objective of this study was to assess the real-world safety and efficacy of the Portico THV (with and without the FlexNav delivery system, Abbott Structural Heart) at the 30-day timepoint in an Australian cohort...
November 4, 2022: Heart, Lung & Circulation
https://read.qxmd.com/read/36142947/comparison-of-transcatheter-aortic-valve-implantation-devices-in-aortic-stenosis-a-network-meta-analysis-of-42-105-patients
#27
JOURNAL ARTICLE
Ala Abu Dogosh, Ahlam Adawi, Aref El Nasasra, Carlos Cafri, Orit Barrett, Gal Tsaban, Rami Barashi, Edward Koifman
Background: In recent years, trans-catheter aortic valve implantation (TAVI) has emerged as an excellent alternative to surgical aortic valve replacement (SAVR). Currently, there are several approved devices on the market, yet comparisons among them are scarce. We aimed to compare the various devices via a network meta-analysis. Methods: We performed a network meta-analysis including randomized controlled trials (RCTs) and propensity-matched studies that provide comparisons of either a single TAVI with SAVR or two different TAVI devices and report clinical outcomes...
September 8, 2022: Journal of Clinical Medicine
https://read.qxmd.com/read/36066987/results-of-new-generation-self-expanding-transcatheter-portico%C3%B1-%C3%B0-valve-implantation-in-patients-with-degenerative-aortic-stenosis
#28
JOURNAL ARTICLE
A E Komlev, T E Imaev, A S Kolegaev, P M Lepilin, M I Makeev, R S Akchurin
Aim    To evaluate 30-day results of the transcatheter correction of degenerative aortic stenosis using a novel self-expandable valve, PorticoTM.Material and methods    Transcatheter aortic valve implantation (TAVI) was performed in 42 patients with an intermediate surgical risk (mean age, 74.3±6.5 years, 8 men, 34 women, EuroSCORE II risk, 2.5 (1.5;4.1)) with severe degenerative aortic stenosis (AS). 20 (48 %) patients had ischemic heart disease; 8 (19%) of patients had atrial fibrillation, and 16 (38%) of patients had type 2 diabetes mellitus...
August 30, 2022: Kardiologiia
https://read.qxmd.com/read/36043277/clinical-and-neurocognitive-outcomes-after-transcatheter-aortic-valve-implantation-tavi-with-cerebral-protection-initial-experience-with-a-novel-dual-filter-device-in-southeast-asia
#29
JOURNAL ARTICLE
Paul Toon Lim Chiam, Nien Shen Chan, Yean Teng Lim, Choon Pin Lim, Dinesh Nair, Tai Tian Lim, Chao Yang Soon, Brian Chung Hoe Khoo, Jimmy Lim, Kok Soon Tan, Leslie Lam, Peter Yan, Yau Wei Ooi, Mei Sian Chong
INTRODUCTION: Transcatheter aortic valve implantation (TAVI) is increasingly performed in patients with severe aortic stenosis. A novel dual-filter system to reduce cerebral embolism during TAVI recently became available. We aimed to assess the feasibility, safety, and clinical and neurocognitive outcomes of TAVI with cerebral protection in Asian patients. METHODS: 40 consecutive patients undergoing TAVI with cerebral protection were enrolled. All procedures were performed via femoral access using the self-expanding Evolut R/PRO or Portico, or the balloon-expandable SAPIEN 3 bioprostheses...
May 2022: Singapore Medical Journal
https://read.qxmd.com/read/36013084/procedural-safety-and-device-performance-of-the-portico%C3%A2-valve-from-experienced-tavi-centers-30-day-outcomes-in-the-multicenter-confidence-registry
#30
JOURNAL ARTICLE
Helge Mollmann, Axel Linke, Luis Nombela-Franco, Martin Sluka, Juan Francisco Oteo Dominguez, Matteo Montorfano, Won-Keun Kim, Martin Arnold, Mariuca Vasa-Nicotera, Lenard Conradi, Anthony Camuglia, Francesco Bedogni, Ganesh Manoharan
A total of 1001 subjects (82.0 years, 62.5% female, 63.7% NYHA III/IV at baseline) with severe aortic stenosis at high surgical risk were enrolled in the prospective CONFIDENCE registry and treated with a Portico™ transcatheter heart valve (THV) using either a first-generation delivery system (DS) or the FlexNav™ DS. The objective of this registry is to characterize the procedural safety and device performance of the Portico™ THV at 30 days. The study collected 'standard-of-care' clinical and device performance data, with adverse events adjudicated by an independent clinical event committee according to the Valve Academic Research Consortium-2 criteria...
August 18, 2022: Journal of Clinical Medicine
https://read.qxmd.com/read/35977925/integrity-of-cerebellar-tracts-associated-with-the-risk-of-bipolar-disorder
#31
JOURNAL ARTICLE
Le Hou, Bess Yin-Hung Lam, Nichol M L Wong, Weicong Lu, Ruoxi Zhang, Yuping Ning, Kangguang Lin
This study examined the structural brain differences across individuals of different BD stages and the risks of developing bipolar disorder (BD) associated with these brain differences. A total of 221 participants who were recruited from the Guangzhou Brain Hospital and the community were categorized into four groups: NC (healthy control) (N = 77), high risk (HR) (N = 42), ultra-high risk (UHR) (N = 38), and bipolar disorder (BD) (N = 64) based on a list of criteria. Their demographics, clinical characteristics, and diffusion magnetic resonance imaging (dMRI) data were collected...
August 17, 2022: Translational Psychiatry
https://read.qxmd.com/read/35926919/coronary-access-following-redo-tavr-impact-of-thv-design-implant-technique-and-cell-misalignment
#32
JOURNAL ARTICLE
David Meier, Mariama Akodad, Uri Landes, Aaron M Barlow, Andrew G Chatfield, Althea Lai, Georgios Tzimas, Gilbert H L Tang, Thomas Puehler, Georg Lutter, Jonathon A Leipsic, Lars Søndergaard, David A Wood, John G Webb, Stephanie L Sellers, Janarthanan Sathananthan
BACKGROUND: The implications and potential challenges of coronary access after redo transcatheter aortic valve replacement (TAVR) are unknown. OBJECTIVES: The authors sought to evaluate the impact of different transcatheter heart valve (THV) designs, neoskirt height, implant technique, and cell misalignment on coronary access after redo TAVR. METHODS: Different THV designs (Sapien 3 [Edwards Lifesciences LLC], Evolut Pro [Medtronic], ACURATE neo [Boston Scientific Corporation], and Portico [Abbott Structural Heart]) and sizes were implanted inside Sapien XT (Edwards Lifesciences LLC) and Evolut R (Medtronic) THVs, which were modeled as the "failed" THVs, at different implant depths...
August 8, 2022: JACC. Cardiovascular Interventions
https://read.qxmd.com/read/35887990/multi-center-comparison-of-two-self-expanding-transcatheter-heart-valves-a-propensity-matched-analysis
#33
JOURNAL ARTICLE
Johannes Blumenstein, Clemens Eckel, Oliver Husser, Won-Keun Kim, Matthias Renker, Yeong-Hoon Choi, Christian W Hamm, Hani Al-Terki, Dagmar Sötemann, Leon Körbi, Vedat Tiyerili, Christina Grothusen, Luise Gaede, Guido Dohmen, Helge Möllmann
BACKGROUND: During the last years, several transcatheter aortic heart valves entered the clinical market and are commercially available. The prostheses differ regarding several technical and functional aspects. However, little is known regarding head-to-head comparative data of the ACURATE neo and the PORTICO valve prostheses. OBJECTIVES: The aim of this study was to compare two self-expanding transcatheter aortic heart valves (THV), the ACURATE neo and the PORTICO, with regard to in-hospital and 30-day outcomes, as well as early device failures...
July 21, 2022: Journal of Clinical Medicine
https://read.qxmd.com/read/35550389/development-of-atrioventricular-and-intraventricular-conduction-disturbances-in-patients-undergoing-transcatheter-aortic-valve-replacement-with-new-generation-self-expanding-valves-a-real-world-multicenter-analysis
#34
JOURNAL ARTICLE
Alex F Castro-Mejía, Ignacio Amat-Santos, Maria E Ortega-Armas, Jose A Baz, Raúl Moreno, Jose Diaz, Alejandro Travieso, Pilar Jimenez-Quevedo, Sandra Santos-Martínez, Angela McInerney, Guillermo Galeote, Victor Alfonso Jimenez Díaz, Jessica Roa Garrido, Gabriela Tirado-Conte, Alejandro Barrero, Luis Marroquin, Ivan Nuñez-Gil, Nieves Gonzalo, Antonio Fernandez-Ortiz, Javier Escaned, Luis Nombela-Franco
BACKGROUND: High degree cardiac conduction disturbances (HDCD) remain a major complication after transcatheter aortic valve replacement (TAVR), especially with self-expandable valves (SEV). Our aim was to investigate peri-procedural and in-hospital modification of atrioventricular and intracardiac conduction associated to new generation SEV implantation, and the development of new HDCD resulting in permanent pacemaker implantation (PPM) in patients undergoing TAVR. METHODS AND RESULTS: Three-hundred forty-four consecutive patients with severe aortic stenosis who underwent TAVR with a new generation SEV [Evolut-R/Pro (n = 130), Acurate-neo (n = 79), Portico (n = 75) and Allegra (n = 60)] were included...
May 9, 2022: International Journal of Cardiology
https://read.qxmd.com/read/35534616/tavi-ct-score-to-evaluate-the-anatomic-risk-in-patients-undergoing-transcatheter-aortic-valve-implantation
#35
JOURNAL ARTICLE
Nicola Corcione, Alberto Morello, Paolo Ferraro, Michele Cimmino, Michele Albanese, Martino Pepe, Palma Luisa Nestola, Salvatore Giordano, Luca Bardi, Giuseppe Biondi-Zoccai, Arturo Giordano
Transcatheter aortic valve implantation (TAVI) requires thorough preprocedural planning with non-invasive imaging, including computed tomography (CT). The plethora of details obtained with thoraco-abdominal CT represents a challenge for accurate and synthetic decision-making. We devised and tested a comprehensive score suitable to summarize CT exams when planning TAVI. An original comprehensive scoring system (TAVI-CT score) was devised, including details on cardiac, aortic, iliac and femoral artery features...
May 9, 2022: Scientific Reports
https://read.qxmd.com/read/35508295/tavi-with-acurate-neo-transcatheter-heart-valve-in-special-populations-a-systematic-review
#36
REVIEW
Leonidas Koliastasis, Ioannis Doundoulakis, Damianos G Kokkinidis, Anastasios Milkas, Maria Drakopoulou, George Benetos, Georgios Latsios, Andreas Synetos, Konstantina Aggeli, Dimitrios Tousoulis, Konstantinos Tsioufis, Konstantinos Toutouzas
BACKGROUND: The ACURATE neo transcatheter aortic valve is a self-expanding device suitable for both transfemoral and transapical approach, but specific groups of patients are under-represented in clinical trials. We aim to provide a comprehensive systematic review on TAVI with ACURATE neo in those special populations. METHODS: TAVI in bicuspid aortic valve, TAVI in patients with small aortic annulus, TAVI for pure aortic regurgitation and valve-in-valve procedures, were systematically reviewed...
May 1, 2022: Hellenic Journal of Cardiology: HJC
https://read.qxmd.com/read/35505271/redo-transcatheter-aortic-valve-implantation-with-the-allegra-transcatheter-heart-valve-insights-from-bench-testing
#37
JOURNAL ARTICLE
Mariama Akodad, Maximilian Kütting, Stephanie Sellers, Alina Kirsten, Philipp Marx, Isabel Kim, Anson Cheung, Jonathon Leipsic, Lars Søndergaard, Stefan Toggweiler, David A Wood, John G Webb, Janarthanan Sathananthan
PURPOSE: Failure of transcatheter heart valves (THV) may potentially be treated with repeat transcatheter aortic valve implantation (redo TAVI). We assessed hydrodynamic performance, stability and pinwheeling utilizing the ALLEGRA (New Valve Technology, Hechingen, Germany) THV, a CE approved and marketed THV in Europe, inside different THVs. METHODS: Redo TAVI was simulated with the 27 mm ALLEGRA THV at three implantation depths (-4 mm, 0 mm and +4 mm) in seven different 'failed' THVs: 26 mm Evolut Pro, 25 mm Lotus, 25 mm JenaValve, 25 mm Portico, 23 mm Sapien 3, 27 mm ALLEGRA and M ACURATE neo...
May 3, 2022: Cardiovascular Engineering and Technology
https://read.qxmd.com/read/35124106/incidence-clinical-impact-and-predictors-of-thrombocytopenia-after-transcatheter-aortic-valve-replacement
#38
JOURNAL ARTICLE
Gabriela Tirado-Conte, Carlos H Salazar, Angela McInerney, Alejandro Cruz-Utrilla, Pilar Jiménez-Quevedo, Javier Cobiella, Nieves Gonzalo, Manuel Carnero, Iván Núñez-Gil, Hernán Mejía-Rentería, Pablo Salinas, Fernando Macaya, Luis C Maroto, Isidre Vilacosta, Antonio Fernández-Ortiz, Javier Escaned, Carlos Macaya, Luis Nombela-Franco
BACKGROUND: Thrombocytopenia is a common, yet poorly understood, complication after transcatheter aortic valve replacement (TAVR). Balloon-expandable transcatheter heart valve has been associated with higher incidence of thrombocytopenia, compared with self-expandable valves. The aim of this study was to analyze the incidence, clinical impact and predictors of acquired thrombocytopenia in patients undergoing TAVR. METHODS: We performed an observational study from consecutive patients with severe aortic stenosis undergoing TAVR (n = 679) in a single center...
April 1, 2022: International Journal of Cardiology
https://read.qxmd.com/read/34979152/myval-versus-alternative-balloon-and-self-expandable-transcatheter-heart-valves-a-central-core-lab-analysis-of-conduction-disturbances
#39
JOURNAL ARTICLE
Sandra Santos-Martinez, Jonathan Halim, Alex Castro-Mejía, Federico De Marco, Carlo Trani, Pedro Martin, Fabio Infusino, Marco Ancona, Raul Moreno, Peter den Heijer, Luis Nombela-Franco, Francesco Bedogni, Gennaro Sardella, Matteo Montorfano, Ana Revilla-Orodea, Jose Raúl Delgado-Arana, Alejandro Barrero, Itziar Gómez-Salvador, Alexander J J IJsselmuiden, Alfredo Redondo, Hipólito Gutiérrez, Ana Serrador, Patrick W Serruys, J Alberto San Román, Ignacio J Amat-Santos
BACKGROUND: Several studies have compared surface electrocardiographic changes following different self-expandable (SE) (Evolut (Medtronic, USA); Acurate (Boston Scientific, USA); Portico (Abbott, USA); and Allegra (NVT, Germany)) and balloon-expandable (BE) Sapien-3 (Edwards Lifesciences, USA) transcatheter heart valves. We aimed to compare these prosthesis with the novel Myval BE prosthesis (Meril Life, India). METHODS: Academic European registry of consecutive patients with severe aortic stenosis who received any of the 6 aforementioned valves...
March 15, 2022: International Journal of Cardiology
https://read.qxmd.com/read/34599425/cusp-overlap-technique-should-it-become-the-standard-implantation-technique-for-self-expanding-valves
#40
REVIEW
Aditya Sengupta, Sophia L Alexis, Timothy Lee, Syed Zaid, Parasuram M Krishnamoorthy, Sahil Khera, Stamatios Lerakis, Malcolm Anastasius, George D Dangas, Samin K Sharma, Annapoorna S Kini, Gilbert H L Tang
PURPOSE OF REVIEW: Accurate imaging of the aortic root during valve implantation is crucial for proper prosthesis positioning during TAVR. The purpose of this review was to determine if routine use of the cusp-overlap view should be adopted for self-expanding valves. RECENT FINDINGS: The use of the cusp-overlap view with the Evolut, Portico, ACURATE neo/neo2, and JenaValve systems is associated with lower post-procedural new permanent pacemaker implantation rates when compared with the standard 3-cusp view, presumably due to more precise valve implantation relative to the conduction system by the non-coronary cusp...
October 1, 2021: Current Cardiology Reports
keyword
keyword
49672
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.