keyword
MENU ▼
Read by QxMD icon Read
search

Doppler

keyword
https://www.readbyqxmd.com/read/27914183/interphalangeal-joint-sonography-of-symptomatic-hand-osteoarthritis-clinical-and-functional-correlation
#1
Natalia de Oliva Spolidoro Paschoal, Jamil Natour, Flavia S Machado, Hilda Alcântara Veiga de Oliveira, Rita Nely Vilar Furtado
OBJECTIVES: To assess the correlation between inflammatory sonographic findings (grayscale synovial hypertrophy and power Doppler) and clinical and functional assessments in hand osteoarthritis (symptomatic interphalangeal joints) and to correlate the intraobserver and interobserver reliability of these findings. METHODS: A prospective double-blind study of 60 interphalangeal joints was conducted. The joints were assessed 6 times per year by clinician and sonographer observers...
December 3, 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27914180/burned-out-testis-tumors-in-asymptomatic-infertile-men-multiparametric-sonography-and-mri-findings
#2
Laurence Rocher, Ludivine Glas, Marie France Bellin, Sophie Ferlicot, Vincent Izard, Gerard Benoit, Laurence Albiges, Karim Fizazi, Jean-Michel Correas
Multiparametric testicular ultrasound and magnetic resonance imaging (MRI) findings were analyzed in a series of 10 infertile asymptomatic men presenting with pathologically confirmed burned-out testicular tumors. Color/power Doppler ultrasound (CDUS), shear wave elastography (SWE), contrast-enhanced ultrasonography (CEUS), and MRI were performed on 10, 5, 6, and 7 patients, respectively. All lesions appeared as a hypoechoic and hypovascular nodular area at CDUS, SWE, CEUS CDUS, and CEUS (if performed). Shear wave elastography showed a stiffer nodular area compared with the surrounding/contralateral tissues (13 versus 2 kPa); MRI revealed a well-delineated nodular area in hypointense signal on T2, a high apparent diffusion coefficient value, and a lack of enhancement...
December 3, 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27914173/color-doppler-sonography-of-extradigital-glomus-tumors
#3
Orlando Catalano, Fernando Alfageme Roldän, Francesco Maria Solivetti, Maria Scotto di Santolo, Marcio Bouer, Ximena Wortsman
We retrospectively collected cases of surgically proven extradigital glomus tumor (EDGT) and reviewed their demographic, clinical, and sonography features. A total of 18 single, subcutaneous EDGTs were gathered. All but one were located in the extremities. EDGTs typically appear as a small, hypoechoic, homogeneous, or slightly inhomogeneous, well-delimited nodule, disposed horizontally and painful under probe pressure. Intranodular vascularization is always present. Feeding artery and efferent vein are typical but inconstant findings...
December 3, 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27913807/determination-of-a-threshold-compromise-value-for-the-perfusion-index-by-laser-doppler-imaging-after-digital-revascularization
#4
Y-Y Chu, D-Y Yu, C-W Chang, F Fang, H-T Liao
: We have used laser Doppler imaging to monitor the microcirculation of replanted digits during the post-operative period in 103 patients who underwent either replantation after traumatic amputation or toe-to-finger reconstruction. The blood flow (perfusion unit) in each revascularized digit was compared with that of an unaffected digit. The perfusion index was defined as the perfusion value of a revascularized digit divided by the perfusion value of the neighbouring normal digit. The ideal threshold value of the perfusion index (0...
December 1, 2016: Journal of Hand Surgery, European Volume
https://www.readbyqxmd.com/read/27913565/a-24-year-old-male-with-a-painful-and-cold-lower-extremity
#5
Eric A Robinson, Zain I Khalpey, Rajesh Janardhanan
CLINICAL INTRODUCTION: A 24-year-old male presented to the emergency department with intense pain in his right lower extremity. He has a medical history significant for systemic lupus erythematosus and antiphospholipid syndrome. He also had four prior episodes of deep venous thromboses on rivaroxaban. The patient stated that early in the morning, he started to feel intense pain that started from his knee and progressed to his calf, with associated numbness and paraesthesia. On physical examination, the limb felt cold with absent right popliteal and dorsalis pedis pulses...
December 2, 2016: Heart: Official Journal of the British Cardiac Society
https://www.readbyqxmd.com/read/27913338/intracardiac-vortex-dynamics-by-high-frame-rate-doppler-vortography-i-in-vivo-i-comparison-with-vector-flow-mapping-and-4-d-flow-mri
#6
Julia Faurie, Mathilde Baudet, Kondo Claude Assi, Dominique Auger, Guillaume Gilbert, Francois Tournoux, Damien Garcia
Recent studies have suggested that intracardiac vortex flow imaging could be of clinical interest to early diagnose the diastolic heart function. Doppler vortography has been intro-duced as a simple color Doppler method to detect and quantify intraventricular vortices. This method is able to locate a vortex core based on the recognition of an antisymmetric pattern in the Doppler velocity field. Because the heart is a fast-moving organ, high frame rates are needed to decipher the whole blood vortex dynamics during diastole...
November 29, 2016: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
https://www.readbyqxmd.com/read/27911329/comparison-of-model-based-indices-of%C3%A2-cerebral-autoregulation-and-vasomotor-reactivity-using-transcranial-doppler-versus-near-infrared-spectroscopy-in%C3%A2-patients-with-amnestic-mild-cognitive-impairment
#7
Vasilis Z Marmarelis, Dae C Shin, Takashi Tarumi, Rong Zhang
We recently introduced model-based "physiomarkers" of dynamic cerebral autoregulation and CO2 vasomotor reactivity as an aid for diagnosis of early-stage Alzheimer's disease (AD) [1], where significant impairment of dynamic vasomotor reactivity (DVR) was observed in early-stage AD patients relative to age-matched controls. Milder impairment of DVR was shown in patients with amnestic mild cognitive impairment (MCI) using the same approach in a subsequent study [2]. The advocated approach utilizes subject-specific data-based models of cerebral hemodynamics to quantify the dynamic effects of resting-state changes in arterial blood pressure and end-tidal CO2 (the putative inputs) upon cerebral blood flow velocity (the putative output) measured at the middle cerebral artery via transcranial Doppler (TCD)...
November 28, 2016: Journal of Alzheimer's Disease: JAD
https://www.readbyqxmd.com/read/27911009/echocardiographic-predictors-of-outcome-in-patients-with-chronic-obstructive-pulmonary-disease
#8
Ivan Stankovic, Robert Marcun, Aleksandra Janicijevic, Jerneja Farkas, Sasa Kadivec, Ivan Ilic, Aleksandar N Neskovic, Mitja Lainscak
BACKGROUND: We aimed to assess the relationship between echocardiographic characteristics and mortality in patients with chronic obstructive pulmonary disease (COPD). METHODS: We prospectively studied 154 patients (mean age 71 ± 10 years, 71% male) with COPD. All patients underwent transthoracic Doppler echocardiography within 48 hours of hospital admission. Primary endpoint was all-cause mortality during a median period of 22 months. RESULTS: Mildly elevated tricuspid regurgitation pressure and mitral E/e' ratio were the most commonly encountered echocardiographic abnormalities, observed in 60% and 56% of patients, respectively...
December 2, 2016: Journal of Clinical Ultrasound: JCU
https://www.readbyqxmd.com/read/27910698/laser-induced-fluorescence-measurements-of-axial-velocity-velocity-shear-and-parallel-ion-temperature-profiles-during-the-route-to-plasma-turbulence-in-a-linear-magnetized-plasma-device
#9
S Chakraborty Thakur, K Adriany, J J Gosselin, J McKee, E E Scime, S H Sears, G R Tynan
We report experimental measurements of the axial plasma flow and the parallel ion temperature in a magnetized linear plasma device. We used laser induced fluorescence to measure Doppler resolved ion velocity distribution functions in argon plasma to obtain spatially resolved axial velocities and parallel ion temperatures. We also show changes in the parallel velocity profiles during the transition from resistive drift wave dominated plasma to a state of weak turbulence driven by multiple plasma instabilities...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910688/first-fast-ion-d-alpha-fida-measurements-and-simulations-on-c-2u
#10
N G Bolte, D Gupta, L Stagner, M Onofri, S Dettrick, E M Granstedt, P Petrov
The first measurements of fast-ion D-alpha (FIDA) radiation have been acquired on C-2U, Tri Alpha Energy's advanced, beam-driven field-reversed configuration (FRC). These measurements are also forward modeled by FIDASIM. This is the first measurement and simulation of FIDA carried out on an FRC topology. FIDA measurements are made of Doppler-shifted Balmer-alpha light from neutralized fast ions using a bandpass filter and photomultiplier tube. One adjustable line-of-sight measured signals at eight locations and eight times during the FRC lifetime over 26 discharges...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910678/first-results-from-the-thomson-scattering-diagnostic-on-proto-mpex
#11
T M Biewer, S Meitner, J Rapp, H Ray, G Shaw
A Thomson scattering (TS) diagnostic has been successfully implemented on the prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory. The diagnostic collects the light scattered by plasma electrons and spectroscopically resolves the Doppler shift imparted to the light by the velocity of the electrons. The spread in velocities is proportional to the electron temperature, while the total number of photons is proportional to the electron density. TS is a technique used on many devices to measure the electron temperature (Te) and electron density (ne) of the plasma...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910672/improved-spatial-calibration-for-the-cxrs-system-on-east
#12
X H Yin, Y Y Li, J Fu, D Jiang, S Y Feng, Y Q Gu, Y Cheng, B Lyu, Y J Shi, M Y Ye, B N Wan
A Charge eXchange Recombination Spectroscopy (CXRS) diagnostic system has been developed to measure profiles of ion temperature and rotation since 2014 on EAST. Several techniques have been developed to improve the spatial calibration of the CXRS diagnostic. The sightline location was obtained by measuring the coordinates of three points on each sightline using an articulated flexible coordinate measuring arm when the vessel was accessible. After vacuum pumping, the effect of pressure change in the vacuum vessel was evaluated by observing the movement of the light spot from back-illuminated sightlines on the first wall using the newly developed articulated inspection arm...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910670/alignment-and-absolute-wavelength-calibration-of-imaging-bragg-spectrometers
#13
G Bertschinger, O Marchuk, R Barnsley
In the present and the next generation of fusion devices, imaging Bragg spectrometers are key diagnostics to measure plasma parameters in the hot core, especially ion temperature and plasma rotation. The latter quantities are routinely obtained using the Doppler-width and -shift of the emitted spectral lines, respectively. Line shift measurements require absolute accuracies Δλ/λ of about 10 ppm, where λ-is the observed wavelength. For ITER and the present fusion devices, spectral lines of He-and H-like argon, iron, and krypton as well as Ne-like tungsten are foreseen for the measurements...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910662/a-novel-multi-channel-quadrature-doppler-backward-scattering-reflectometer-on-the-hl-2a-tokamak
#14
Zhongbing Shi, Wulu Zhong, Min Jiang, Zengchen Yang, Boyu Zhang, Peiwan Shi, Wei Chen, Jie Wen, Chengyuan Chen, Bingzhong Fu, Zetian Liu, Xuantong Ding, Qingwei Yang, Xuru Duan
A novel 16-channel fixed frequency Doppler backward scattering (DBS) reflectometer system has been developed on the HL-2A tokamak. This system is based on the filter-based feedback loop microwave source (FFLMS) technique, which has lower phase noise and lower power variation compared with present tunable frequency generation and comb frequency array generation techniques [J. C. Hillesheim et al. Rev. Sci. Instrum. 80, 083507 (2009) and W. A. Peebles et al. Rev. Sci. Instrum. 81, 10D902 (2010)]. The 16-channel DBS system is comprised of four × four-frequency microwave transmitters and direct quadrature demodulation receivers...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910643/quasi-optical-design-for-systems-to-diagnose-the-electron-temperature-and-density-fluctuations-on-east
#15
Qifo Cao, Yong Liu, Hailin Zhao, Tianfu Zhou, Ang Ti, Liqun Hu
A system to simultaneously diagnose the electron temperature and density fluctuations is proposed for Experimental Advanced Superconducting Tokamak device. This system includes a common quasi-optical antenna, a correlation electron cyclotron emission (CECE) system that is used to measure the electron temperature fluctuations and a Doppler backscattering (DBS) system that is used to measure the electron density fluctuations. The frequency range of the proposed CECE system is 108-120 GHz, and this corresponds to a radial coverage of normalized radius ((R - R0)/a, R0 = 1850 mm, a = 450 mm) from 0...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910630/sensitivity-of-mse-measurements-on-the-beam-atomic-level-population
#16
C Ruiz, S T A Kumar, F S B Anderson, D T Anderson
The effect of variation in atomic level population of a neutral beam on the Motional Stark Effect (MSE) measurements is investigated in the low density plasmas of HSX stellarator. A 30 KeV, 4 A, 3 ms hydrogen diagnostic neutral beam is injected into HSX plasmas of line averaged electron density ranging from 2 to 4 ⋅ 10(18) m(-3) at a magnetic field of 1 T. For this density range, the excited level population of the hydrogen neutral beam is expected to undergo variations. Doppler shifted and Stark split Hα and Hβ emissions from the beam are simultaneously measured using two cross-calibrated spectrometers...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910615/measurement-of-diagnostic-neutral-beam-parameters-on-j-text
#17
J R Wang, Z F Cheng, Z Li, Y Li, J Luo, X L Zhang, G Zhuang
A Doppler frequency shift spectrum (DFSS) system composed of two spectrometers has been developed for the joint Texas experimental tokamak to measure diagnostic neutral beam parameters including the beam energy fractions, intensity distributions, and divergences. The beam energy fractions are derived from measurements of H-alpha (Hα) emission using collisional excitation cross sections. The beam intensity distributions are obtained using an 11-channel measurement with a reconstruction technique. The beam divergences are obtained from spectrum broadening and geometric calculations...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910612/jet-diagnostic-enhancements-in-preparation-for-dt-operations
#18
J Figueiredo, A Murari, C Perez Von Thun, D Marocco, M Tardocchi, F Belli, M García Muñoz, A Silva, S Soare, T Craciunescu, M Santala, P Blanchard, I Balboa, N Hawkes
In order to complete the exploitation of the JET ITER-like Wall and to take full benefit from deuterium-tritium experiments on JET, a set of diagnostic system refurbishments or upgrades is in progress. These diagnostic enhancements focus mainly on neutron, gamma, fast ions, instabilities, and operations support. These efforts intend to provide better spatial, temporal, and energy resolution while increasing measurement coverage. Also previously non-existing capabilities, such as Doppler reflectometry is now available for scientific exploitation...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910605/fast-ion-d%C3%AE-spectrum-diagnostic-in-the-east
#19
Y M Hou, C R Wu, J Huang, W W Heidbrink, M G von Hellermann, Z Xu, Z Jin, J F Chang, Y B Zhu, W Gao, Y J Chen, B Lyu, R J Hu, P F Zhang, L Zhang, W Gao, Z W Wu, Y Yu, M Y Ye
In toroidal magnetic fusion devices, fast-ion D-alpha diagnostic (FIDA) is a powerful method to study the fast-ion feature. The fast-ion characteristics can be inferred from the Doppler shifted spectrum of Dα light according to charge exchange recombination process between fast ions and probe beam. Since conceptual design presented in the last HTPD conference, significant progress has been made to apply FIDA systems on the Experimental Advanced Superconducting Tokamak (EAST). Both co-current and counter-current neutral beam injectors are available, and each can deliver 2-4 MW beam power with 50-80 keV beam energy...
November 2016: Review of Scientific Instruments
https://www.readbyqxmd.com/read/27910558/preliminary-measurements-of-the-edge-magnetic-field-pitch-from-2-d-doppler-backscattering-in-mast-and-nstx-u-invited
#20
R G L Vann, K J Brunner, R Ellis, G Taylor, D A Thomas
The Synthetic Aperture Microwave Imaging (SAMI) system is a novel diagnostic consisting of an array of 8 independently phased antennas. At any one time, SAMI operates at one of the 16 frequencies in the range 10-34.5 GHz. The imaging beam is steered in software post-shot to create a picture of the entire emission surface. In SAMI's active probing mode of operation, the plasma edge is illuminated with a monochromatic source and SAMI reconstructs an image of the Doppler back-scattered (DBS) signal. By assuming that density fluctuations are extended along magnetic field lines, and knowing that the strongest back-scattered signals are directed perpendicular to the density fluctuations, SAMI's 2-D DBS imaging capability can be used to measure the pitch of the edge magnetic field...
November 2016: Review of Scientific Instruments
keyword
keyword
4816
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"