keyword
MENU ▼
Read by QxMD icon Read
search

Immediate implant placement

keyword
https://www.readbyqxmd.com/read/28802762/clinical-application-of-autogenous-partially-demineralized-dentin-matrix-prepared-immediately-after-extraction-for-alveolar-bone-regeneration-in-implant-dentistry-a-pilot-study
#1
T Minamizato, T Koga, Takashi I, Y Nakatani, M Umebayashi, Y Sumita, T Ikeda, I Asahina
The aim of this study was to examine the efficacy and safety of autogenous partially demineralized dentin matrix (APDDM) prepared onsite, for clinical application in bone regeneration procedures related to implant dentistry, including socket preservation, alveolar ridge augmentation, and maxillary sinus floor augmentation. In this study, 16 patients underwent dental implant placement using APDDM transplantation. There were no systemic or local complications (including surgical site infection) in any of the cases, and oral rehabilitation using dental implants was successful in all cases for at least 2 years after attachment of the suprastructure...
August 9, 2017: International Journal of Oral and Maxillofacial Surgery
https://www.readbyqxmd.com/read/28790165/prognostic-value-of-fractional-flow-reserve-measured-immediately-after-drug-eluting-stent-implantation
#2
Zsolt Piroth, Gabor G Toth, Pim A L Tonino, Emanuele Barbato, Soheila Aghlmandi, Nick Curzen, Gilles Rioufol, Nico H J Pijls, William F Fearon, Peter Jüni, Bernard De Bruyne
BACKGROUND: The predictive value of fractional flow reserve (FFR) measured immediately after percutaneous coronary intervention (PCI) with drug-eluting stent placement has not been prospectively investigated. We investigated the potential of post-PCI FFR measurements to predict clinical outcome in patients from FAME 1 and 2 trials (Fractional Flow Reserve or Angiography for Multivessel Evaluation). METHODS AND RESULTS: All patients of FAME 1 and FAME 2 who had post-PCI FFR measurement were included...
August 2017: Circulation. Cardiovascular Interventions
https://www.readbyqxmd.com/read/28781070/immediate-implant-placement-and-complete-mouth-rehabilitation-with-cad-cam-titanium-frameworks-and-cemented-crowns-for-a-patient-with-severe-periodontal-disease-a-clinical-report
#3
Pei Wang, Chunbo Tang, Yi Tang, Yunong Wu
The technique of immediate implantation has been widely used to reduce treatment time and bone loss after extraction. However, immediate implant placement in infected extraction sockets is generally contraindicated. This clinical report describes a treatment protocol for immediate implantation after the extraction of teeth with generalized chronic periodontitis. The technique used for the oral rehabilitation used computer-assisted design and computer-assisted manufacturing (CAD-CAM) titanium frameworks and cemented zirconia crowns...
August 4, 2017: Journal of Prosthetic Dentistry
https://www.readbyqxmd.com/read/28766018/s2-ai-screw-placement-with-the-aide-of-electronic-conductivity-device-monitoring-a-retrospective-analysis
#4
Faheem A Sandhu, Jason E McGowan, Daniel R Felbaum, Hasan R Syed, Kyle B Mueller
STUDY DESIGN: A retrospective analysis of two consecutive patients who underwent a novel surgical technique. OBJECTIVE: A report of a novel surgical technique utilizing an electronic conductivity device guidance to aide placement of S2-Alar-Iliac (S2-AI) instrumentation. Electronic conductivity guidance for instrumentation of the thoracolumbar spine is an accepted means of improving intraoperative accuracy. Although commercially available for percutaneous techniques, there is a paucity of literature regarding its use...
August 1, 2017: European Spine Journal
https://www.readbyqxmd.com/read/28753195/freehand-versus-guided-surgery-factors-influencing-accuracy-of-dental-implant-placement
#5
William Choi, Bao-Chau Nguyen, Andrew Doan, Sabine Girod, Brice Gaudilliere, Dyani Gaudilliere
INTRODUCTION: Patient anatomy, practitioner experience, and surgical approach are all factors that influence implant accuracy. However, the relative importance of each factor is poorly understood. The present study aimed to identify which factors most critically determine implant accuracy to aid the practitioner in case selection for guided versus freehand surgery. METHODS: One practitioner's ideal implant angulation and position was compared with his achieved position radiographically for 450 implants placed using a conventional freehand method...
July 20, 2017: Implant Dentistry
https://www.readbyqxmd.com/read/28744958/post-extraction-implant-placement-into-infected-versus-non-infected-sites-a-multicenter-retrospective-clinical-study
#6
Francesco Zuffetti, Matteo Capelli, Fabio Galli, Massimo Del Fabbro, Tiziano Testori
PURPOSE: The aim of this study was to assess whether immediate implant placement into post-extraction sites presenting a chronic infection poses a greater risk of implant failure than immediate placement in non-infected sites. MATERIALS AND METHODS: Records of patients who underwent extraction and immediate implant placement into both infected and non-infected sites from January 1998 to September 2014 at 5 different dental centers were considered for inclusion. Included records were subjected to statistical analysis of survival rates, along with a number of other patient-, implant-, surgery-, and prosthesis-related variables...
July 26, 2017: Clinical Implant Dentistry and related Research
https://www.readbyqxmd.com/read/28739320/immediate-implant-placement-into-posterior-sockets-with-or-without-buccal-bone-dehiscence-defects-a-retrospective-cohort-study
#7
Chen Hu, Ting Gong, Weimin Lin, Quan Yuan, Yi Man
OBJECTIVES: To evaluate bone reconstruction and soft tissue reactions at immediate implants placed into intact sockets and those with buccal bone dehiscence defects. METHODS: Fifty-nine internal connection implants from four different manufacturers were immediately placed in intact sockets(non-dehiscence group, n=40), and in alveoli with buccal bone dehiscence defects: 1) Group 1(n= N10), the defect depth measured 3-5 mm from the gingival margin. 2) Group 2(n=9), the depth ranged from 5mm to 7mm...
July 21, 2017: Journal of Dentistry
https://www.readbyqxmd.com/read/28734634/immediate-implant-placement-the-fate-of-the-buccal-crest-a-retrospective-cone-beam-computed-tomography-study
#8
E Groenendijk, T A Staas, F E J Graauwmans, E Bronkhorst, L Verhamme, T Maal, G J Meijer
This retrospective study aimed to analyse the fate of the buccal crest after immediate implant placement (IIP) through the use of cone beam computed tomography (CBCT). In 16 consecutive patients, an implant was placed in a more palatal position after extraction, thereby creating a gap of at least 2mm between the implant and the buccal crest. Subsequently, this gap was filled with a bone substitute. Preoperatively, immediate postoperatively, and late postoperatively, a CBCT was made to measure the thickness of the buccal crest...
July 19, 2017: International Journal of Oral and Maxillofacial Surgery
https://www.readbyqxmd.com/read/28731896/freehand-versus-guided-surgery-factors-influencing-accuracy-of-dental-implant-placement
#9
William Choi, Bao-Chau Nguyen, Andrew Doan, Sabine Girod, Brice Gaudilliere, Dyani Gaudilliere
INTRODUCTION: Patient anatomy, practitioner experience, and surgical approach are all factors that influence implant accuracy. However, the relative importance of each factor is poorly understood. The present study aimed to identify which factors most critically determine implant accuracy to aid the practitioner in case selection for guided versus freehand surgery. METHODS: One practitioner's ideal implant angulation and position was compared with his achieved position radiographically for 450 implants placed using a conventional freehand method...
August 2017: Implant Dentistry
https://www.readbyqxmd.com/read/28727471/cutting-edge-implant-rehabilitation-design-and-management-a-tapered-abutment-approach
#10
Mark Bishara, Gregori M Kurtzman
Immediate implant placement can pose challenges surgically and, ultimately, restoratively. Yet immediate placement has become the standard when adequate bone is present to achieve primary stability and site infection is minimal. To avoid prosthetic complications and ensure the implant is encased in bone after healing, proper planning must consider that implant placement does not necessarily need to follow the trajectory of the root socket. As discussed in this article, maxillary anterior sites have potential issues related to the "triangle of bone" that are not encountered in molar sites and demand different approaches to ensure treatment success...
July 2017: Compendium of Continuing Education in Dentistry
https://www.readbyqxmd.com/read/28717791/residual-root-preparation-%C3%A2-for-socket-shield-procedures-%C3%A2-a-facial-window-approach
#11
Phillip Roe, Joseph Y K Kan, Kitichai Rungcharassaeng
Two common complications that occur following immediate implant placement and provisionalization procedures in the anterior maxilla are changes to the facial periimplant soft tissue levels and the facial contours. To counteract these changes, different techniques and treatments have been recommended. The recently introduced socket-shield technique (SST) appears to be a viable treatment option for stabilizing the facial osseous and gingival architecture; however, preparation of the root fragment can present challenges...
2017: International Journal of Esthetic Dentistry
https://www.readbyqxmd.com/read/28716703/bridge-to-surgery-best-practice-protocol-derived-from-early-clinical-experience-with-the-bridge-occlusion-balloon-federated-agreement-from-the-eleventh-annual-lead-management-symposium
#12
Bruce L Wilkoff, Charles Kennergren, Charles J Love, Steven P Kutalek, Laurence M Epstein, Roger Carrillo
No abstract text is available yet for this article.
July 14, 2017: Heart Rhythm: the Official Journal of the Heart Rhythm Society
https://www.readbyqxmd.com/read/28713743/bone-ring-augmentation-around-immediate-implants-a-clinical-and-radiographic-study
#13
Girish B Giraddi, Aamir Malick Saifi
PURPOSE: The purpose of this study was to evaluate the efficacy of bone ring augmentation technique for three-dimensional augmentation of severely defective sockets along with placement of immediate dental implants. MATERIALS AND METHODS: A clinical study was conducted on 14 patients with 15 defective sockets requiring extractions and immediate implant placement. Following extraction, bone ring with an implant osteotomy, harvested from chin, was sculptured and fitted into the extraction socket...
January 2017: Annals of Maxillofacial Surgery
https://www.readbyqxmd.com/read/28713661/pre-surgical-provisional-prosthesis-for-immediate-non-occlusal-loaded-flapless-implant
#14
Athiban Inbarajan, Fathima Banu, Padmanabhan Tv, Anand Kumar, Madhan Seenivasan
A 49-year-old patient reported for immediate replacement of missing maxillary anterior teeth with implant-retained prosthesis. Elevation of flap alters the mucosal level, causes discomfort, and delays the restorative procedure. To maintain the esthetics, flapless surgery was planned. Since placement of an implant is pre-planned in a predetermined site, fabrication of the prostheses before commencement of the surgery, especially when replacing the teeth in the anterior region, could be a viable option. This case report explains the method of fabrication of the provisional restoration for flapless surgery in the presurgical phase...
June 13, 2017: Curēus
https://www.readbyqxmd.com/read/28713600/periodontics-implantology-and-prosthodontics-integrated-the-zenith-driven-rehabilitation
#15
Fausto Frizzera, Mateus Tonetto, Guilherme Cabral, Jamil Awad Shibli, Elcio Marcantonio
A customized treatment plan is important to reach results that will satisfy the patient providing esthetics, function, and long-term stability. This type of oral rehabilitation requires professionals from different dental specialties where communication is a major key point. Digital Smile Design allows the practitioners to plan and discuss the patient's condition to establish the proper treatment plan, which must be driven by the desired zenith position. The ideal gingival position will guide the professionals and determine the need to perform surgical procedures or orthodontic movement before placing the final restorations...
2017: Case Reports in Dentistry
https://www.readbyqxmd.com/read/28709673/stereophotogrammetric-impression-making-for-polyoxymethylene-milled-immediate-partial-fixed-dental-prostheses
#16
Miguel Gómez-Polo, Cristina Gómez-Polo, Jaime Del Río, Rocío Ortega
Immediate post-extraction and same-day placement of interim prostheses have increased patient acceptance of implant-supported prostheses. However, for immediate prostheses supported by multiple implants, meeting passive fit and esthetic standards is often challenging. In this clinical report, implant photogrammetry was combined with conventionally obtained digitized casts to prepare an interim, milled prosthesis from a polyoxymethylene (POM) disk, using computer-aided design and computer-aided manufacturing techniques...
July 11, 2017: Journal of Prosthetic Dentistry
https://www.readbyqxmd.com/read/28708470/safety-and-efficacy-of-an-absorbable-filter-in-the-inferior-vena-cava-to-prevent-pulmonary-embolism-in-swine
#17
Steven Y Huang, Mitchell Eggers, Mark J McArthur, Katherine A Dixon, Amanda McWatters, Stephen Dria, Lori R Hill, Marites P Melancon, Joseph R Steele, Michael J Wallace
Purpose To evaluate the immediate and long-term safety as well as thrombus-capturing efficacy for 5 weeks after implantation of an absorbable inferior vena cava (IVC) filter in a swine model. Materials and Methods This study was approved by the institutional animal care and use committee. Eleven absorbable IVC filters made from polydioxanone suture were deployed via a catheter in the IVC of 11 swine. Filters remained in situ for 2 weeks (n = 2), 5 weeks (n = 2), 12 weeks (n = 2), 24 weeks (n = 2), and 32 weeks (n = 3)...
July 14, 2017: Radiology
https://www.readbyqxmd.com/read/28705072/short-and-long-term-results-after-endovascular-management-of-vascular-complications-during-transfemoral-aortic-valve-implantation
#18
Thomas Heger, Stefanie Strauß, Erwin Blessing, Martin Andrassy, Christian Erbel, Oliver J Müller, Emmanuel Chorianopoulos, Sven Pleger, Florian Leuschner, Grigorios Korosoglou, Raffi Bekeredjian, Hugo A Katus, Britta Vogel
Background Vascular injury and access site complications in the contemporary setting of transcatheter aortic valve implantation (TAVI) are known to be associated with increased mortality and morbidity. The aim of our study was to analyse the feasibility and safety of percutaneous treatment of such vascular complications using a stent graft. Methods Between January 2010 and April 2013, 36 TAVI patients developed severe access site complications and underwent subsequent interventional treatment with a covered stent...
July 14, 2017: Acta Cardiologica
https://www.readbyqxmd.com/read/28696960/sinus-floor-augmentation-with-ambient-blood-and-an-absorbable-collagen-sponge-a-prospective-pilot-clinical-study
#19
Antoine Berberi, Nabih Nader, Rita Bou Assaf, Hussein Fayyad-Kazan, Saad Khairalah, Nabil Moukarzel
PURPOSE: The aim of this study was to clinically, radiologically, and histologically evaluate a sinus augmentation technique using a resorbable collagen sponge to maintain space between the Schneiderian membrane and the residual crestal bone. MATERIALS AND METHODS: Patients with partially edentulous maxillae were clinically and radiographically evaluated for implant placement. A total of 10 consecutive patients with the bone height for implant placement (<4.0 mm) were enrolled in the study...
July 10, 2017: Implant Dentistry
https://www.readbyqxmd.com/read/28689908/the-insertion-torque-depth-curve-integral-as-a-measure-of-implant-primary-stability-an-in%C3%A2-vitro-study-on-polyurethane-foam-blocks
#20
Danilo Alessio Di Stefano, Paolo Arosio, Giorgio Gastaldi, Enrico Gherlone
STATEMENT OF PROBLEM: Recent research has shown that dynamic parameters correlate with insertion energy-that is, the total work needed to place an implant into its site-might convey more reliable information concerning immediate implant primary stability at insertion than the commonly used insertion torque (IT), the reverse torque (RT), or the implant stability quotient (ISQ). Yet knowledge on these dynamic parameters is still limited. PURPOSE: The purpose of this in vitro study was to evaluate whether an energy-related parameter, the torque-depth curve integral (I), could be a reliable measure of primary stability...
July 6, 2017: Journal of Prosthetic Dentistry
keyword
keyword
45166
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"