https://read.qxmd.com/read/38623668/spurious-high-platelet-count-without-plt-flag-s-in-a-patient-with-severe-aplastic-anaemia
#21
Luyun Peng, Rui Shi, Feng Lu, Ge Zhang
BACKGROUND: Platelet (PLT) count is one of the most important parameters of automated hematology, as spurious PLT reports could affect medical judgement and bring significant risks. In most cases, spurious PLT will not be reported for review criteria, which will be triggered by abnormal PLT histograms and PLT flag(s). Here, we present a case of severe aplastic anemia after hematopoietic stem cell transplantation with spurious high platelet count with normal histogram and no PLT flag(s)...
April 1, 2024: Clinical Laboratory
https://read.qxmd.com/read/38623664/early-prediction-of-bloodstream-infection-with-complete-blood-count-parameters-an-ex-vivo-human-whole-blood-model
#22
JOURNAL ARTICLE
Seyda Ignak, Ozlem Unay-Demirel, Meral Yuksel
BACKGROUND: Despite the advanced laboratory technologies available today, blood culture is the gold standard method in the diagnosis of bloodstream infections. Automated blood culture devices give blood culture results for laboratories approximately in 2 - 3 days up to 7 days. Moreover, some microorganisms like nonreproducible bacteria, fungi or viruses cannot be produced in culture. Among all samples taken for blood culture on suspicion of infection approximately 10% are determined as positive whereas the false positive rate due to contamination is 5%...
April 1, 2024: Clinical Laboratory
https://read.qxmd.com/read/38622069/multicolor-assay-on-a-chip-processed-by-robotic-operation-macpro-with-improved-diagnostic-accuracy-for-field-deployable-detection
#23
JOURNAL ARTICLE
Binyao Liu, Yixin Cheng, Xiang Pan, Wen Yang, Xiangpeng Li, Lele Wang, Haihang Ye, Tingrui Pan
The ability to deploy decentralized laboratories with autonomous and reliable disease diagnosis holds the potential to deliver accessible healthcare services for public safety. While microfluidic technologies provide precise manipulation of small fluid volumes with improved assay performance, their limited automation and versatility confine them to laboratories. Herein, we report the utility of multicolor assay-on-a-chip processed by robotic operation (MACpro), to address this unmet need. The MACpro platform comprises a robot-microfluidic interface and an eye-in-hand module that provides flexible yet stable actions to execute tasks in a programmable manner, such as the precise manipulation of the microfluidic chip along with different paths...
April 15, 2024: Analytical Chemistry
https://read.qxmd.com/read/38619294/comparison-evaluation-of-automated-nucleated-red-blood-cell-enumeration-by-sysmex-xn-1000-in-comparison-with-microscopic-reference-in-children-under-1-year
#24
JOURNAL ARTICLE
Sophie Brunner-Ziegler, Bernd Jilma, Gabriele Grimm, Petra Jilma-Stohlawetz
BACKGROUND: In newborns, elevated nucleated red blood cell (NRBC) levels can be associated with enhanced erythropoietic stress and might be predictive for adverse outcome. Also, the presence of NRBC in peripheral blood might lead to erroneous enumeration results of white blood cells in automated hematology analyzers. We aimed to assess the comparability of the Sysmex XN 1000 to manual slide reviews and correlation of NRBC with inflammation markers. METHODS: Specimens of 3397 children under 1 year were compared by automated and microscopic NRBC enumeration...
April 15, 2024: Journal of Clinical Laboratory Analysis
https://read.qxmd.com/read/38617587/comparison-of-elisa-with-automated-eclia-for-il-6-determination-in-covid-19-patients-an-italian-real-life-experience
#25
JOURNAL ARTICLE
Francesca Romano, Luisa Lanzilao, Edda Russo, Maria Infantino, Francesca Nencini, Giovanni Cappelli, Stefano Dugheri, Mariangela Manfredi, Alessandra Fanelli, Amedeo Amedei, Nicola Mucci
OBJECTIVES: Coronavirus disease 2019 (COVID-19) has a wide spectrum of clinical severity. A cytokine storm is associated with COVID-19 severity. Of these, IL-6 is significantly associated with higher mortality and is also a marker for predicting disease prognosis. IL-6 may act as a target for therapeutics and, a blockade of IL-6 function by Tocilizumab has been described as a treatment of the inflammatory process COVID-19-related. This study aims to describe our experience comparing two different methods, in detail Human IL-6 Instant ELISA and the Elecsys IL-6 based on ECLIA, for the IL-6 assessment...
March 2024: Practical Laboratory Medicine
https://read.qxmd.com/read/38616153/an-explainable-long-short-term-memory-network-for-surgical-site-infection-identification
#26
JOURNAL ARTICLE
Amber C Kiser, Jianlin Shi, Brian T Bucher
BACKGROUND: Currently, surgical site infection surveillance relies on labor-intensive manual chart review. Recently suggested solutions involve machine learning to identify surgical site infections directly from the medical record. Deep learning is a form of machine learning that has historically performed better than traditional methods while being harder to interpret. We propose a deep learning model, a long short-term memory network, for the identification of surgical site infection from the medical record with an attention layer for explainability...
April 13, 2024: Surgery
https://read.qxmd.com/read/38611001/clinical-validation-of-the-vitro-hpv-screening-assay-for-its-use-in-primary-cervical-cancer-screening
#27
JOURNAL ARTICLE
Beatriz Bellosillo, Raquel Ibáñez, Esther Roura, Laura Monfil, Laura Asensio-Puig, Isabel Álvarez, Mercè Muset, Yolanda Florencia, Sonia Paytubi, Álvaro de Andrés-Pablo, Susana Calvo, Laia Serrano-Munné, Miguel Ángel Pavón, Belen Lloveras
Many scientific societies have issued guidelines to introduce population-based cervical cancer screening with HPV testing. The Vitro HPV Screening assay is a fully automatic multiplex real-time PCR test targeting the L1 GP5+/GP6+ region of HPV genome. The assay detects 14 high risk (HR) HPV genotypes, identifying individual HPV16 and HPV18 genotypes, and the HPV-positive samples for the other 12 HR HPV types are subsequently genotyped with the HPV Direct Flow Chip test. Following international guidelines, the aim of this study was to validate the clinical accuracy of the Vitro HPV Screening test on ThinPrep-collected samples for its use as primary cervical cancer screening, using as comparator the validated cobas® 4800 HPV test...
March 28, 2024: Cancers
https://read.qxmd.com/read/38607807/comparison-of-the-solid-phase-red-cell-adherence-assay-and-tube-method-for-detection-and-identification-of-red-blood-cell-antibodies
#28
JOURNAL ARTICLE
Mohamed Abdelmonem, Alex Dussaq, Kathy Papakonstantino, Muharrem Yunce, Mrigender Singh Virk
OBJECTIVES: Identifying antibodies to red blood cell antigens is one of transfusion medicine's critical responsibilities. The International Society of Blood Transfusion recognizes 354 red blood cell antigens. Accurate identification of clinically significant alloantibodies is imperative for preventing hemolytic transfusion reactions and hemolytic disease of the fetus and newborn. We compared the performance of the tube (polyethylene glycol-indirect antiglobulin test [PEG-IAT]) and solid-phase red cell adherence assay techniques...
April 12, 2024: American Journal of Clinical Pathology
https://read.qxmd.com/read/38600723/quantitative-determination-of-r-s-methadone-in-human-serum-using-ultra-high-performance-supercritical-fluid-chromatography-tandem-mass-spectrometry-a-method-for-routine-use
#29
JOURNAL ARTICLE
Miriam Hansen, Hilde Havnen, Trine Naalsund Andreassen, Olav Spigset, Solfrid Hegstad
Methadone has two enantiomers, which exhibit differences in pharmacological effects, with R-methadone being the active and S-methadone the inactive enantiomer. A robust, simple and rapid method for chiral separation of the two enantiomers in serum samples using ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MSMS) has been developed and validated. Enantiomeric separation was achieved using a Chiralpak IH-3 column with a mobile phase consisting of CO2 and 30mM ammonium acetate in methanol/water (98/2, v/v)...
April 10, 2024: Drug Testing and Analysis
https://read.qxmd.com/read/38600621/generative-artificial-intelligence-to-produce-high-fidelity-blastocyst-stage-embryo-images
#30
JOURNAL ARTICLE
Ping Cao, Josien Derhaag, Edith Coonen, Han Brunner, Ganesh Acharya, Andres Salumets, Masoud Zamani Esteki
STUDY QUESTION: Can generative artificial intelligence (AI) models produce high-fidelity images of human blastocysts? SUMMARY ANSWER: Generative AI models exhibit the capability to generate high-fidelity human blastocyst images, thereby providing substantial training datasets crucial for the development of robust AI models. WHAT IS KNOWN ALREADY: The integration of AI into IVF procedures holds the potential to enhance objectivity and automate embryo selection for transfer...
April 10, 2024: Human Reproduction
https://read.qxmd.com/read/38599621/icodextrin-induced-acute-generalized-exanthematous-pustulosis-in-a-patient-with-peritoneal-dialysis
#31
Chun-Hao Liu, Chien-Chou Chen, Chih-Chien Sung
Icodextrin has been widely prescribed for peritoneal dialysis (PD) patients with inadequate ultrafiltration, but icodextrin induced acute generalized exanthematous pustulosis (AGEP) has been not well recognized in clinical practice. We described a young-aged female with IgA nephropathy and end stage kidney disease under continuous automated peritoneal dialysis. She developed skin erythema with exfoliation over the groin 7th day after initiation of icodextrin based PD dialysate. Initially, her scaling skin lesion with pinhead-sized pustules affected the bilateral inguinal folds, and then it extended to general trunk accompanied by pruritus...
April 10, 2024: Nephrology
https://read.qxmd.com/read/38598990/two-fields-are-better-than-one-a-multifunctional-semi-automated-setup-for-quantitative-measurements-of-parahydrogen-induced-signal-enhancement-at-low-and-high-fields
#32
JOURNAL ARTICLE
Franziska Theiss, Jonas Lins, Jan Kergassner, Laura Wienands, Sonja Döller, Gerd Buntkowsky
The rapid advancement of parahydrogen-induced hyperpolarization (PHIP) and its diverse array of applications highlights the critical need for enhanced signals in both 1 H NMR and heteronuclear NMR spectroscopy. Simultaneously, there is an increasing interest in utilizing benchtop NMR analysis across various laboratory settings. However, due to their lower magnetic fields, benchtop NMR spectrometers inherently produce weaker signal intensities. Here, PHIP is a well-established solution to this challenge. Consequently, we are expanding our cost-effective PHIP setup from a high-field NMR spectrometer (11...
April 9, 2024: Journal of Magnetic Resonance
https://read.qxmd.com/read/38597977/association-between-dietary-magnesium-intake-inflammation-and-neurodegeneration
#33
JOURNAL ARTICLE
Khawlah Alateeq, Erin I Walsh, Ananthan Ambikairajah, Nicolas Cherbuin
BACKGROUND: Consistent evidence shows that magnesium (Mg) intake is associated with lower blood pressure (BP), and that lower BP is associated with improved cerebral health. However, recent findings indicate that the positive effect of dietary Mg intake on cerebral health is not mediated by a decrease in BP. As Mg's anti-inflammatory action is a plausible alternative mechanism, the objective of this study was to investigate the associations between Mg intake and inflammation to determine whether it mediates any neuroprotective effect...
April 10, 2024: European Journal of Nutrition
https://read.qxmd.com/read/38597655/performance-of-two-modified-two-tier-algorithms-for-the-serologic-diagnosis-of-lyme-disease
#34
JOURNAL ARTICLE
Marie L Landry, Sajjad Hassan, Bruce G Rottmann, Stacey J Pesak, Michael Ordazzo, Michael Skrzyniarz, Steven Deponte, David R Peaper
UNLABELLED: We compared the performance of a new modified two-tier testing (MTTT) platform, the Diasorin Liaison chemiluminescent immunoassay (CLIA), to the Zeus enzyme-linked immunoassay (ELISA) MTTT and to Zeus ELISA/Viramed immunoblot standard two-tier testing (STTT) algorithm. Of 537 samples included in this study, 91 (16.9%) were positive or equivocal by one or more screening tests. Among these 91 samples, only 57 samples were concordant positive by first-tier screening tests, and only 19 of 57 were concordant by the three second-tier methods...
April 10, 2024: Journal of Clinical Microbiology
https://read.qxmd.com/read/38596899/transition-between-peritoneal-dialysis-modalities-impact-on-blood-pressure-levels-and-drug-prescription-in-a-national-multicentric-cohort
#35
JOURNAL ARTICLE
Marcus Dariva, Murilo Guedes, Vladimir Rigodon, Peter Kotanko, John W Larkin, Bruno Ferlin, Roberto Pecoits-Filho, Pasqual Barretti, Thyago Proença de Moraes
BACKGROUND: Hypertension is a leading cause of kidney failure, affects most dialysis patients and associates with adverse outcomes. Hypertension can be difficult to control with dialysis modalities having differential effects on sodium and water removal. There are two main types of peritoneal dialysis (PD), automated peritoneal dialysis (APD) and continuous ambulatory peritoneal dialysis (CAPD). It is unknown whether one is superior to the other in controlling blood pressure (BP). Therefore, the aim of our study was to analyse the impact of switching between these two PD modalities on BP levels in a nationally representative cohort...
April 10, 2024: Peritoneal Dialysis International
https://read.qxmd.com/read/38594837/the-dilution-evaluation-as-a-corrective-measure-for-interference-in-the-white-blood-cell-scattergram-in-beckman-coulter-dxh-900
#36
JOURNAL ARTICLE
Filipa P Freitas, Jorge Reis, Joana Oliveira, Pedro Mota Veiga, Ana Raquel Paiva, Rui Soares
BACKGROUND: The Beckman Coulter DxH 900 is a haematological analyser capable of counting and sizing blood cells, and obtaining a complete blood cell count (CBC). This analyses different parameters of red blood cells (RBC), platelets and white blood cells/leukocytes. Some automated CBC counters present limitations due to specimen characteristics, abnormal cells or both factors. In the presence of abnormalities, the DxH 900 has a flagging system, warning the laboratory technician that something needs to be verified...
April 9, 2024: Journal of Clinical Laboratory Analysis
https://read.qxmd.com/read/38593278/analysis-of-mandibular-jaw-movements-to-assess-ventilatory-support-management-of-children-with-obstructive-sleep-apnea-syndrome-treated-with-positive-airway-pressure-therapies
#37
JOURNAL ARTICLE
Julie Cassibba, Guillaume Aubertin, Jean Benoit Martinot, Nam Le Dong, Eglantine Hullo, Nicole Beydon, Audrey Dupont-Athénor, Guillaume Mortamet, Jean Louis Pépin
BACKGROUND: The polysomnography (PSG) is the gold-standard for obstructive sleep apnea (OSA) syndrome diagnosis and assessment under positive airway pressure (PAP) therapies in children. Recently, an innovative digital medicine solution, including a mandibular jaw movement (MJM) sensor coupled with automated analysis, has been validated as an alternative to PSG for pediatric application. OBJECTIVE: This study aimed to assess the reliability of MJM automated analysis for the assessment of residual apnea/hypopnea events during sleep in children with OSA treated with noninvasive ventilation (NIV) or continuous PAP (CPAP)...
April 9, 2024: Pediatric Pulmonology
https://read.qxmd.com/read/38593236/add-on-testing-stability-assessment-of-63-biochemical-analytes-in-centrifuged-and-capped-samples-stored-at-16%C3%A2-%C3%A2-c
#38
JOURNAL ARTICLE
Anne J Nielsen, Søren A Ladefoged, Jeppe B Madsen
OBJECTIVES: Integration of add-on testing in high-scale automated clinical laboratories constitute a valuable instrument not only for the clinicians and the general patient care, but also for the laboratory itself. Knowledge on sample quality and analytical stability upon storage is necessary to be able to offer add-on testing. The objectives of this study were to examine the analytical stability of 63 biochemical analytes in plasma and urine samples stored at 16 °C. METHODS: Samples were collected by professional laboratory technicians, analyzed at automated analyzers and stored in their primary, capped tube without separator for 10, 12, 16, 20 or 24 h at 16 °C...
April 10, 2024: Clinical Chemistry and Laboratory Medicine: CCLM
https://read.qxmd.com/read/38589790/association-of-haemato-biochemical-indices-and-blood-composite-ratios-with-microfilaridermia-in-onchocerciasis-patients
#39
JOURNAL ARTICLE
Linda Batsa Debrah, Charles Gyasi, Monica Ahiadorme, Abu Abudu Rahamani, Vera Serwaa Opoku, Prince Obeng, Jubin Osei-Mensah, Michael Agyemang Obeng, Derrick Adu Mensah, Alexander Yaw Debrah
BACKGROUND: Onchocerciasis causes chronic systemic inflammation. Several studies have used markers such as haemato-biochemical indices to predict the occurrence of systemic inflammation. This study assessed the variability and predictability of haemato-biochemical indices and blood composite ratios (BCRs) in microfilariae positive (MF+) and microfilariae negative (MF-) subgroups of onchocercomata participants. METHODS: One hundred and five (105) MF + and 34 MF- participants were retrospectively recruited into the study...
April 8, 2024: BMC Infectious Diseases
https://read.qxmd.com/read/38588779/rsv-genoscan-an-automated-pipeline-for-whole-genome-human-respiratory-syncytial-virus-rsv-sequence-analysis
#40
JOURNAL ARTICLE
Alexandre Dosbaa, Romane Guilbaud, Anna-Maria Franco Yusti, Valentine Marie Ferré, Charlotte Charpentier, Diane Descamps, Quentin Le Hingrat, Romain Coppée
BACKGROUND: Advances in high-throughput sequencing (HTS) technologies and reductions in sequencing costs have revolutionised the study of genomics and molecular biology by making whole-genome sequencing (WGS) accessible to many laboratories. However, the analysis of WGS data requires significant computational effort, which is the major drawback in implementing WGS as a routine laboratory technique. OBJECTIVE: Automated pipelines have been developed to overcome this issue, but they do not exist for all organisms...
April 6, 2024: Journal of Virological Methods
keyword
keyword
43380
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.