keyword
https://read.qxmd.com/read/37064370/a-comparison-of-computed-tomography-imaging-with-histopathology-in-the-sensitivity-and-correlation-of-evaluating-coronary-arterial-calcification
#21
JOURNAL ARTICLE
Yun-Fei Liu, Yan-He Ma, Chang-Yue Wang, Xiang-Li Zhang, Ke-Ke Liang, Jing Tao, Lin Guo, Bu-Lang Gao
BACKGROUND: The sensitivity and correlation of coronary computed tomography angiography (CTA) as compared with histopathology are unknown in evaluating coronary arterial calcification. In this study, we retrospectively evaluated qualitatively and quantitatively the sensitivity and correlation of coronary CTA compared with histopathology in assessing coronary arterial calcification. METHODS: This study was conducted on 12 randomly selected cadavers aged over 40 years at the time of death, and 53 segments of coronary arteries from these 12 cadavers were obtained from the Human Anatomy Laboratory of Tianjin Medical University...
April 1, 2023: Quantitative Imaging in Medicine and Surgery
https://read.qxmd.com/read/37046543/image-quality-analysis-of-photon-counting-ct-compared-with-dual-source-ct-a-phantom-study-for-chest-ct-examinations
#22
JOURNAL ARTICLE
Marine Deleu, Jean-Baptiste Maurice, Laura Devos, Martine Remy, François Dubus
A comparison was made between the image quality of a photon-counting CT (PCCT) and a dual-source CT (DSCT). The evaluation of image quality was performed using a Catphan CT phantom, and the physical metrics, such as the noise power spectrum and task transfer function, were measured for both PCCT and DSCT at three CT dose indices (1, 5 and 10 mGy). Polyenergetic and virtual monoenergetic reconstructions were used to evaluate the performance differences by simulating a Gaussian spot with a radius of 5 mm and calculating the detectability index...
April 3, 2023: Diagnostics
https://read.qxmd.com/read/37015832/comparison-of-first-generation-and-third-generation-dual-source-computed-tomography-for-detecting-coronary-artery-disease-in-patients-evaluated-for-transcatheter-aortic-valve-replacement
#23
JOURNAL ARTICLE
Matthias Renker, Robert Steinbach, U Joseph Schoepf, Ulrich Fischer-Rasokat, Yeong-Hoon Choi, Christian W Hamm, Andreas Rolf, Won-Keun Kim
PURPOSE: This study compared image quality and evaluability of coronary artery disease (CAD) in routine preparatory imaging for transcatheter aortic valve replacement using 64-slice (first-generation) to 192-slice (third-generation) dual-source computed tomography(DSCT). MATERIALS AND METHODS: The CT data sets of 192 patients (122 women, median age 82 y) without severe renal dysfunction or known CAD were analyzed retrospectively. Half were examined using first-generation DSCT (June 2014 to February 2016) and the other half with third-generation DSCT (April 2016 to April 2017)...
April 3, 2023: Journal of Thoracic Imaging
https://read.qxmd.com/read/37004360/impact-of-the-automatic-tube-current-modulation-atcm-system-on-virtual-monoenergetic-image-quality-for-dual-source-ct-a-phantom-study
#24
JOURNAL ARTICLE
D Dabli, Quentin Durand, J Frandon, Fabien de Oliveira, Maxime Pastor, J P Beregi, J Greffier
PURPOSE: To assess the impact of the automatic tube current modulation (ATCM) on virtual monoenergetic images (VMIs) quality in dual-source CT(DSCT). MATERIALS AND METHODS: Acquisitions were performed on DSCT using the Mercury phantom. The acquisition parameters for an abdomen-pelvic examination with single-energy CT(SECT) and dual-energy CT(DECT) imaging were used. Acquisitions were performed for each imaging mode using fixed mAs and ATCM. The mAs value was set to obtain a volume CT dose index of 11 mGy in fixed mAs acquisitions...
March 31, 2023: Physica Medica: PM
https://read.qxmd.com/read/36856300/coronary-cta-for-acute-chest-pain-in-the-emergency-department-comparison-of-64-detector-row-single-source-and-third-generation-dual-source-scanners
#25
JOURNAL ARTICLE
Ji Hoon Kim, Song-Ee Baek, Young Jin Kim, Young Joo Suh
Background: When performing coronary CTA in the emergency department (ED), a contemporary scanner with improved temporal resolution may eliminate the need to administer beta blockers for heart rate (HR) control, thereby expediting workup. Objective: To compare ED length-of-stay (LOS), image quality, frequency of nondiagnostic examinations, and other clinical outcomes between patients undergoing coronary CTA in the ED by a single-source CT (SSCT) scanner with HR control versus a dual-source CT (DSCT) scanner without HR control...
March 1, 2023: AJR. American Journal of Roentgenology
https://read.qxmd.com/read/36703218/nomogram-based-on-spectral-ct-quantitative-parameters-and-typical-radiological-features-for-distinguishing-benign-from-malignant-thyroid-micro-nodules
#26
JOURNAL ARTICLE
Zuhua Song, Qian Li, Dan Zhang, Xiaojiao Li, Jiayi Yu, Qian Liu, Zongwen Li, Jie Huang, Xiaodi Zhang, Zhuoyue Tang
PURPOSE: To analyse the predictive effect of a nomogram combining dual-layer spectral computed tomography (DSCT) quantitative parameters with typical radiological features in distinguishing benign micro-nodule from thyroid microcarcinoma (TMC). METHODS: Data from 342 instances with thyroid micro-nodules (≤1 cm) who underwent DSCT (benign group: n = 170; malignant group: n = 172) were reviewed. Typical radiological features including micro-calcification and enhanced blurring, and DSCT quantitative parameters including attenuation on virtual monoenergetic images (40 keV, 70 keV and 100 keV), the slope of the spectral HU curve (λHU), normalized iodine concentration (NIC), and normalized effective atomic number (NZeff) in the arterial phase (AP) and venous phase (VP), were measured and compared between the benign and malignant groups...
January 26, 2023: Cancer Imaging: the Official Publication of the International Cancer Imaging Society
https://read.qxmd.com/read/36539919/application-of-dual-source-computed-tomography-in-the-diagnosis-of-thyroid-cancer-and-evaluation-of-biological-behaviors
#27
JOURNAL ARTICLE
Wenhui Wu, Xuewen Fang, Jianming Li, An Zhang, Yujian Zou, Xiaolin Zheng
OBJECTIVE: Thyroid cancer (TC) is an extremely prevailing malignant endocrine tumor. Therefore, effective diagnostic tools are necessary. This study explored the application value of dual-source computed tomography (DSCT) in TC diagnosis and biological behavior assessment. METHODS: This study retrospectively selected 68 TC patients and another 74 benign patients with thyroid adenoma, nodular goiter, or adenomatous hyperplasia. All patients were confirmed by pathological examination and underwent DSCT examination...
December 20, 2022: Journal of Clinical Ultrasound: JCU
https://read.qxmd.com/read/36320865/the-daily-swab-test-collection-problem
#28
JOURNAL ARTICLE
Roberto Aringhieri, Sara Bigharaz, Alessandro Druetto, Davide Duma, Andrea Grosso, Alberto Guastalla
Digital Contact Tracing (DCT) has been proved to be an effective tool to counteract the new SARS-CoV-2 or Covid-19. Despite this widespread effort to adopt the DCT, less attention has been paid to the organisation of the health logistics system that should support the tracing activities. Actually, the DCT poses a challenge to the logistics of the local health system in terms of number of daily tests to be collected and evaluated, especially when the spreading of the virus is soaring. In this paper we introduce a new optimisation problem called the Daily Swab Test Collection (DSTC) problem, that is the daily problem of collecting swab tests at home in such a way to guarantee a timely testing to people notified by the app to be in contact with a positive case...
October 27, 2022: Annals of Operations Research
https://read.qxmd.com/read/35909023/three-dimensional-reconstruction-with-dual-source-computed-tomography-for-evaluating-graft-deformation-and-bone-tunnel-position-following-reconstruction-of-the-anterior-cruciate-ligament
#29
JOURNAL ARTICLE
Guangzheng Li, Yang Xie, Bin Xu
OBJECTIVE: Considering the limitations of MRI and X-ray and few studies on the use of dual-source computed tomography (DSCT) in anterior cruciate ligament (ACL) reconstruction are limited, this study explored the clinical application of DSCT for three-dimensional reconstruction of graft deformation and bone tunnel position images following ACL reconstruction. METHODS: The data of 123 patients who underwent single-bundle ACL reconstruction under arthroscopy from January 2017 to October 2021 were retrieved...
July 23, 2022: Medical Engineering & Physics
https://read.qxmd.com/read/35832127/differential-diagnosis-of-preinvasive-lesions-in-small-pulmonary-nodules-by-dual-source-computed-tomography-imaging
#30
JOURNAL ARTICLE
Hongjun Yan, Ye Hua, Tingcui Zhang, Wen Liu
This study was aimed to explore the differential diagnosis value of preinvasive lesions/minimally invasive adenocarcinoma and invasive adenocarcinoma manifesting as small pulmonary nodules under dual source computed tomography (DSCT) imaging. The patients with nodular manifestations of adenocarcinoma in situ (AIS)/microinfiltrating adenocarcinoma (MIA) were selected as group X, including 14 cases. A total of 31 cases with nodular infiltrating adenocarcinoma were selected as group Y. The enhanced dual-energy image obtained by DSCT dual-energy scan was transferred to the software to obtain the energy image and iodine distribution map...
2022: Computational and Mathematical Methods in Medicine
https://read.qxmd.com/read/35774215/comparison-of-high-pitch-prospective-electrocardiogram-gated-pulmonary-ct-angiography-with-standard-ct-pulmonary-angiography-on-dual-source-ct-for-detection-of-subsegmental-pulmonary-embolism-in-patients-suspected-of-acute-pulmonary-embolism
#31
JOURNAL ARTICLE
Rohini Thakur, Manphool Singhal, Ashutosh Nath Aggrawal, Ujjwal Gorsi, Navneet Sharma, Ashish Bhalla, Niranjan Khandelwal
Purpose: Objective of this study was to compare high-pitch prospective electrocardiogram (ECG)-gated computed tomography (CT) pulmonary angiography (HP-PECG-gated CTPA) with standard-pitch non-ECG-gated CT pulmonary angiography (SP-NECG-gated CTPA) on 128-slice dual-source CT (DSCT) for the detection of subsegmental pulmonary embolism (SSPE) in patients suspected of acute pulmonary embolism (APE) with radiation and contrastoptimized protocols. Cardiac-related motion artefacts, lung image quality, and quantitative parameter (pulmonary arterial enhancement, radiation exposure, and contrast) volumes were also compared...
2022: Polish Journal of Radiology
https://read.qxmd.com/read/35760710/radiation-dose-reduction-in-contrast-enhanced-abdominal-ct-comparison-of-photon-counting-detector-ct-with-2nd-generation-dual-source-dual-energy-ct-in-an-oncologic-cohort
#32
JOURNAL ARTICLE
Robin Wrazidlo, Lukas Walder, Arne Estler, Ralf Gutjahr, Bernhard Schmidt, Sebastian Faby, Jan Fritz, Konstantin Nikolaou, Marius Horger, Florian Hagen
RATIONAL AND OBJECTIVES: Comparison of radiation dose and image quality in routine abdominal and pelvic contrast-enhanced computed tomography (CECT) between a photon-counting detector CT (PCD-CT) and a dual energy dual source CT (DSCT). MATERIALS AND METHODS: 70 oncologic patients (mean age 66 ± 12 years, 29 females) were prospectively enrolled between November 2021 and February 2022. Abdominal CECT were clinically indicated and performed first on a 2nd -generation DSCT and at follow-up on a 1st -generation dual-source PCD-CT...
June 24, 2022: Academic Radiology
https://read.qxmd.com/read/35736867/image-quality-and-radiation-dose-of-contrast-enhanced-chest-ct-acquired-on-a-clinical-photon-counting-detector-ct-vs-second-generation-dual-source-ct-in-an-oncologic-cohort-preliminary-results
#33
JOURNAL ARTICLE
Florian Hagen, Lukas Walder, Jan Fritz, Ralf Gutjahr, Bernhard Schmidt, Sebastian Faby, Fabian Bamberg, Stefan Schoenberg, Konstantin Nikolaou, Marius Horger
Our aim was to compare the image quality and patient dose of contrast-enhanced oncologic chest-CT of a first-generation photon-counting detector (PCD-CT) and a second-generation dual-source dual-energy CT (DSCT). For this reason, one hundred consecutive oncologic patients (63 male, 65 ± 11 years, BMI: 16−42 kg/m2) were prospectively enrolled and evaluated. Clinically indicated contrast-enhanced chest-CT were obtained with PCD-CT and compared to previously obtained chest-DSCT in the same individuals...
June 3, 2022: Tomography: a Journal for Imaging Research
https://read.qxmd.com/read/35705551/image-quality-and-radiation-dose-of-dual-source-high-pitch-computed-tomography-in-pediatric-congenital-heart-disease
#34
JOURNAL ARTICLE
Dmitrij Kravchenko, Christopher Hart, Stephan Garbe, Julian A Luetkens, Alexander Isaak, Narine Mesropyan, Mathieu Vergnat, Judith Leyens, Ulrike Attenberger, Daniel Kuetting
To explore the image quality and radiation dose of dual source high-pitch cardiac computed tomography with tailored contrast injection protocols for pediatric congenital heart disease patients (CHD). In total, 27 infants with CHD (median age 109 days [IQR 6-199]) were retrospectively analyzed regarding dose length product (DLP) and effective dose (ED) after undergoing cardiothoracic CT imaging. Scan parameters were adjusted on a dual source/detector CT (DSCT) to minimize radiation dose while maintaining adequate quality...
June 15, 2022: Scientific Reports
https://read.qxmd.com/read/35587754/the-association-between-number-of-teeth-and-cognitive-frailty-in-older-adults-a-cross-sectional-study
#35
JOURNAL ARTICLE
X-M Zhang, X Wu, W Chen
OBJECTIVES: This study aimed to explore the association between number of teeth and cognitive frailty in American older adults. DESIGN: Cross-sectional study. SETTING: Community. PARTICIPANTS: The participants were 1,531 community-dwelling older adults aged 60 or older from the NHANES database. METHODS: Frailty was assessed using a 49-item frailty index, with a cut-off value for frailty of more than 0...
2022: Journal of Nutrition, Health & Aging
https://read.qxmd.com/read/35580575/pulmonary-ct-scans-of-white-rabbits-using-the-selective-photon-shield-technique-of-the-third-generation-dual-source-ct
#36
JOURNAL ARTICLE
Wenjie Sun, Hui Tan, Yi Wang, An Xie, Xianzheng Tan, Peng Liu, Dan Xu, Feng Huang
This study aims to optimise the protocol for the low-dose pulmonary computed tomography (CT) scanning of infants by studying the effects of the selective photon shield (SPS) technique of the third-generation dual-source CT (DSCT) on the image quality and radiation dose of a chest CT in white rabbits under different tube currents. Twelve white rabbits of a similar weight to an infant were selected and randomly divided into an experimental group and a control group. The experimental groups (A1-A5) were scanned at low dose by the third-generation DSCT using SPS under different tube current × time (60, 50, 40, 30, and 20 mAs)...
June 20, 2022: Journal of Radiological Protection: Official Journal of the Society for Radiological Protection
https://read.qxmd.com/read/35558972/lung-volume-determination-by-dual-source-computed-tomography-in-infants-with-pulmonary-artery-sling-a-case-control-study
#37
JOURNAL ARTICLE
Qiuyi Cai, Bing Wen, Jianlin Li, Liangbo Hu, Jian Liu, Hao Yang
Background: Pulmonary artery sling (PAS) is associated with tracheal stenosis and left pulmonary artery (LPA) dysplasia in infants, both developmental abnormalities that may lead to pulmonary hypoplasia and lung volume changes. As such, we aimed to monitor the effects of tracheal stenosis and pulmonary vascular malformation on lung volumes in infants with PAS and their correlation with lung volumes in infants with PAS using dual-source computed tomography (DSCT). Methods: A case-control study was performed...
April 2022: Translational Pediatrics
https://read.qxmd.com/read/35508600/cta-analysis-of-482-cases-of-coronary-artery-fistula-a-large-scale-imaging-study
#38
JOURNAL ARTICLE
Renhui Cai, Xiaojing Ma, Xinxiang Zhao, Juan Xu, Li Zhu, Leizhi Ku
OBJECTIVE: The prevalence of coronary artery fistula (CAF) based on coronary angiography has been reported. However, with the popularity of coronary computerized tomography angiography (CTA), CAFs have been found more and more by chance. The purpose of this study was to determine the prevalence and types of CAFs detected by coronary CTA, and to explore the differences in the size of fistulas, the number of complicated aneurysms, and fistulas among different types. MATERIALS AND METHODS: From January 2016 to December 2020, 96,037 patients underwent coronary CTA in our hospital...
May 4, 2022: Journal of Cardiac Surgery
https://read.qxmd.com/read/35472649/image-quality-and-dose-exposure-of-contrast-enhanced-abdominal-ct-on-a-1st-generation-clinical-dual-source-photon-counting-detector-ct-in-obese-patients-vs-a-2nd-generation-dual-source-dual-energy-integrating-detector-ct
#39
JOURNAL ARTICLE
Florian Hagen, Johannes Hofmann, Robin Wrazidlo, Ralf Gutjahr, Bernhard Schmidt, Sebastian Faby, Konstantin Nikolaou, Marius Horger
PURPOSE: To compare the radiation dose as well as the image quality of contrast-enhanced abdominal 1st-generation Photon-Counting Detector CT (PCD-CT) to a 2nd-generation Dual-Source Dual-Energy-Integrating-Detector CT (DSCT) in obese patients. METHOD: 51 overweight (BMI ≥ 25 kgm2) patients (median age: 67.00 years; IQR: 59.00-73.00, median BMI 32.15 kgm2; IQR: 28.70-35.76) who underwent clinically indicated, contrast-enhanced abdominal-CT in portal-venous phase on both 2nd-generation DSCT and on a commercially available 1st-generation PCD-CT were prospectively included the degree of obesity was defined by BMI-calculation (overweight, obesity grade I/30-34...
June 2022: European Journal of Radiology
https://read.qxmd.com/read/35313178/verbal-learning-working-memory-and-attention-vigilance-may-be-candidate-phenotypes-of-bipolar-ii-depression-in-chinese-han-nationality
#40
JOURNAL ARTICLE
Zhizhong Hu, Maorong Hu, Xin Yuan, Huijuan Yu, Jingzhi Zou, Yanyan Zhang, Zihang Lu
OBJECTIVES: Bipolar II depression (BD-II) is a subtype of bipolar disorder with recurrent depressive, manic, and frequent depressive episodes as the main clinical manifestations. This study aimed to compare the cognitive function of patients with BD-II with those of healthy siblings and controls to explore the internal phenotype of BD-II in the field of cognitive function. METHODS: 66 BD-II patients, 58 healthy siblings, and 55 healthy controls were assessed with the Trail Making Test (TMT), Digit Symbol Coding Test (DSCT), Category Fluency, Hopkins Verbal Learning Test-Revised (HVLTR), Brief Visuospatial Memory Test-Revised (BVMT-R), Wechsler Memory Scale 3rd ed...
March 18, 2022: Acta Psychologica
keyword
keyword
42052
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems