https://www.readbyqxmd.com/read/26471067/accuracy-of-the-masimo-set%C3%A2-lncs-neo-peripheral-pulse-oximeter-in-cyanotic-congenital-heart-disease
#1
Michael J Griksaitis, Gemma E Scrimgeour, John V Pappachan, Andrew J Baldock
UNLABELLED: Introduction Non-invasive peripheral pulse oximeters are routinely used to measure oxyhaemoglobin saturation (SpO2) in cyanotic congenital heart disease. These probes are calibrated in healthy adult volunteers between arterial saturations of ~75 and 100%, using the gold standard of co-oximetry on arterial blood samples. There are little data to attest their accuracy in cyanotic congenital heart disease. Aims We aimed to assess the accuracy of a commonly used probe in children with cyanotic congenital heart disease...
August 2016: Cardiology in the Young
https://www.readbyqxmd.com/read/25978517/accuracy-of-pulse-oximeters-in-detecting-hypoxemia-in-patients-with-chronic-thromboembolic-pulmonary-hypertension
#2
Tomoki Kohyama, Kiyoshi Moriyama, Riichiro Kanai, Mariko Kotani, Kohji Uzawa, Toru Satoh, Tomoko Yorozu
PURPOSE: Pulse oximetry is routinely used to continuously and non-invasively monitor arterial oxygen saturation (SaO2). When oxygen saturation by pulse oximeter (SpO2) overestimates SaO2, hypoxemia may be overlooked. We compared the SpO2 - SaO2 differences among three pulse oximeters in patients with chronic thromboembolic pulmonary hypertension (CTEPH) who spent their daily lives in a poor oxygen state. MATERIAL AND METHOD: This prospective observational study recruited 32 patients with CTEPH undergoing elective cardiac catheterization...
2015: PloS One
https://www.readbyqxmd.com/read/23477959/accuracy-of-carboxyhemoglobin-detection-by-pulse-co-oximetry-during-hypoxemia
#3
RANDOMIZED CONTROLLED TRIAL
John R Feiner, Mark D Rollins, Jeffrey W Sall, Helge Eilers, Paul Au, Philip E Bickler
BACKGROUND: Carbon monoxide poisoning is a significant problem in most countries, and a reliable method of quick diagnosis would greatly improve patient care. Until the recent introduction of a multiwavelength "pulse CO-oximeter" (Masimo Rainbow SET(®) Radical-7), obtaining carboxyhemoglobin (COHb) levels in blood required blood sampling and laboratory analysis. In this study, we sought to determine whether hypoxemia, which can accompany carbon monoxide poisoning, interferes with the accurate detection of COHb...
October 2013: Anesthesia and Analgesia
https://www.readbyqxmd.com/read/21048100/the-accuracy-of-noninvasive-and-continuous-total-hemoglobin-measurement-by-pulse-co-oximetry-in-human-subjects-undergoing-hemodilution
#4
COMPARATIVE STUDY
Mark R Macknet, Martin Allard, Richard L Applegate, James Rook
BACKGROUND: Total hemoglobin (tHb) is one the most frequently ordered laboratory measurements. Pulse CO-Oximetry™ (Masimo Corp., Irvine, CA) is a multi-wavelength spectrophotometric method for noninvasive and continuous hemoglobin monitoring (SpHb). In this study, we evaluated the accuracy of SpHb compared with laboratory CO-Oximeter measurement of tHb from arterial blood samples in 20 healthy volunteer subjects undergoing hemodilution. METHODS: After enrollment, approximately 500 mL of blood was drawn from subjects through an arterial or venous catheter...
December 2010: Anesthesia and Analgesia
https://www.readbyqxmd.com/read/20841412/improved-accuracy-of-methemoglobin-detection-by-pulse-co-oximetry-during-hypoxia
#5
John R Feiner, Philip E Bickler
BACKGROUND: Methemoglobin in the blood cannot be detected by conventional pulse oximetry and may bias the oximeter's estimate (Spo(2)) of the true arterial functional oxygen saturation (Sao(2)). A recently introduced "pulse CO-oximeter" (Masimo Rainbow SET® Radical-7) that measures SpMet, a noninvasive measurement of the percentage of methemoglobin in arterial blood (%MetHb), was shown to read spuriously high values during hypoxia. In this study we sought to determine whether the manufacturer's modifications have improved the device's ability to detect and accurately measure methemoglobin and deoxyhemoglobin simultaneously...
November 2010: Anesthesia and Analgesia
https://www.readbyqxmd.com/read/20007731/accuracy-of-methemoglobin-detection-by-pulse-co-oximetry-during-hypoxia
#6
John R Feiner, Philip E Bickler, Paul D Mannheimer
BACKGROUND: Methemoglobin in the blood cannot be detected by conventional pulse oximetry, although it can bias the oximeter's estimate (Spo2) of the true arterial functional oxygen saturation (Sao2). A recently introduced "Pulse CO-Oximeter" (Masimo Rainbow SET(R) Radical-7 Pulse CO-Oximeter, Masimo Corp., Irvine, CA) is intended to additionally monitor noninvasively the fractional carboxyhemoglobin and methemoglobin content in blood. The purpose of our study was to determine whether hypoxia affects the new device's estimated methemoglobin reading accuracy, and whether the presence of methemoglobin impairs the ability of the Radical-7 and a conventional pulse oximeter (Nonin 9700, Nonin Medical Inc...
July 2010: Anesthesia and Analgesia
https://www.readbyqxmd.com/read/17660732/evaluation-of-analytic-and-motion-resistant-performance-of-the-mindray-9006-pulse-oximeter
#7
Liming Peng, Cunliang Yan, Hong Lu, Yong Xia
BACKGROUND: The Mindray 9006 is a newly developed pulse oximeter. The performance of noninvasive monitoring of arterial oxygen saturation by pulse oximetry (SpO(2)) and pulse rate (PR) with the Mindray 9006 was evaluated. MATERIAL/METHODS: Twenty healthy volunteers participated in this study. The Mindray 9006 was evaluated according to guidelines including HS3-A, EP5-A, and EP9-A2 published by the CLSI, and ISO 9919. A blinded side-by-side comparison of the Mindray 9006 and the Masimo MS-3 oximeter was also performed...
August 2007: Medical Science Monitor: International Medical Journal of Experimental and Clinical Research
1
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"