keyword
https://read.qxmd.com/read/38635487/potential-indicators-of-intestinal-necrosis-in-portal-venous-gas-a-case-report-of-an-82-year-old-woman-on-long-term-hemodialysis-with-ascites-and-pneumatosis-coli
#21
JOURNAL ARTICLE
Yoshio Hisata, Naoko E Katsuki, Masaki Tago, Tomoyo Nishi, Tomotaro Nakashima, Yoshimasa Oda, Shu-Ichi Yamashita
BACKGROUND Several factors have been reported as possible predictors of intestinal necrosis in patients with portal venous gas (PVG). We describe potential indicators of intestinal necrosis in PVG identified by contrasting 3 episodes of PVG in a patient on hemodialysis against previously verified factors. CASE REPORT An 82-year-old woman undergoing hemodialysis was admitted to our hospital thrice for acute abdominal pain. On first admission, she was alert, with a body temperature of 36.3°C, blood pressure (BP) of 125/53 mmHg, pulse rate of 60/min, respiratory rate of 18/min, and 100% oxygen saturation on room air...
April 18, 2024: American Journal of Case Reports
https://read.qxmd.com/read/38634193/review-of-osmotic-dehydration-promising-technologies-for-enhancing-products-attributes-opportunities-and-challenges-for-the-food-industries
#22
JOURNAL ARTICLE
Ali Asghari, P Assana Zongo, Emmanuel Freddy Osse, Sara Aghajanzadeh, Vijaya Raghavan, Seddik Khalloufi
Osmotic dehydration (OD) is an efficient preservation technology in that water is removed by immersing the food in a solution with a higher concentration of solutes. The application of OD in food processing offers more benefits than conventional drying technologies. Notably, OD can effectively remove a significant amount of water without a phase change, which reduces the energy demand associated with latent heat and high temperatures. A specific feature of OD is its ability to introduce solutes from the hypertonic solution into the food matrix, thereby influencing the attributes of the final product...
May 2024: Comprehensive Reviews in Food Science and Food Safety
https://read.qxmd.com/read/38634171/association-between-arterial-pulse-waveform-analysis-and-mortality-in-patients-with-septic-shock-a-retrospective-cohort-study-using-japanese-diagnosis-procedure-combination-data
#23
JOURNAL ARTICLE
Koji Endo, Kayoko Mizuno, Satomi Yoshida, Koji Kawakami
Purpose: Specialized pressure transducers for arterial pulse waveform analysis (S-APWA) devices are dedicated kits connected to an arterial pressure catheter that monitors hemodynamic parameters, such as cardiac output, pulse pressure variation, and stroke volume variation, less invasively. While the association between the use of S-APWA devices and clinical outcomes in perioperative patients has been previously evaluated, its assessment in patients with septic shock remains inadequate. Materials and Methods: This retrospective cohort study utilized a nationwide Diagnosis Procedure Combination database in Japan...
April 18, 2024: Journal of Intensive Care Medicine
https://read.qxmd.com/read/38633637/an-innovative-approach-for-assessing-coronary-artery-lesions-fusion-of-wrist-pulse-and-photoplethysmography-using-a-multi-sensor-pulse-diagnostic-device
#24
JOURNAL ARTICLE
M A Xiaotian, Rui Guo, Chunke Zhang, Jianjun Yan, Guangyao Zhu, Wenjie Wu, Haixia Yan, Leixin Hong
Coronary heart disease (CHD) is a leading cause of mortality globally and poses a significant threat to public health. Coronary angiography (CAG) is a gold standard for the clinical diagnosis of CHD, but its invasiveness restricts its widespread application. In this study, we utilized a pulse diagnostic device equipped with pressure and photoelectric sensors to synchronously and non-invasively capture wrist pressure pulse waves and fingertip photoplethysmography (FPPG) of patients undergoing CAG. The extracted features were utilized in constructing random forest-based models to assessing the severity of coronary artery lesions...
April 15, 2024: Heliyon
https://read.qxmd.com/read/38633081/tissue-mimicking-materials-and-finger-phantom-design-for-pulse-oximetry
#25
JOURNAL ARTICLE
Andres J Rodriguez, Sandhya Vasudevan, Masoud Farahmand, Sandy Weininger, William C Vogt, Christopher G Scully, Jessica Ramella-Roman, T Joshua Pfefer
Pulse oximetry represents a ubiquitous clinical application of optics in modern medicine. Recent studies have raised concerns regarding the potential impact of confounders, such as variable skin pigmentation and perfusion, on blood oxygen saturation measurement accuracy in pulse oximeters. Tissue-mimicking phantom testing offers a low-cost, well-controlled solution for characterizing device performance and studying potential error sources, which may thus reduce the need for costly in vivo trials. The purpose of this study was to develop realistic phantom-based test methods for pulse oximetry...
April 1, 2024: Biomedical Optics Express
https://read.qxmd.com/read/38633076/fair-non-contact-blood-pressure-estimation-using-imaging-photoplethysmography
#26
JOURNAL ARTICLE
Hongli Fang, Jiping Xiong, Linying He
Hypertension is typically manifested as a latent symptom that requires detection through specialized equipment. This poses an inconvenience for individuals who need to undergo long-term blood pressure monitoring in their daily lives. Therefore, there is a need for a portable, non-contact method for estimating blood pressure. However, current non-contact blood pressure estimation methods often rely on relatively narrow datasets, lacking a broad range of blood pressure distributions. Additionally, their applicability is confined to controlled experimental environments...
April 1, 2024: Biomedical Optics Express
https://read.qxmd.com/read/38633075/preserving-shape-details-of-pulse-signals-for-video-based-blood-pressure-estimation
#27
JOURNAL ARTICLE
Xuesong Han, Xuezhi Yang, Shuai Fang, Yawei Chen, Qin Chen, Longwei Li, RenCheng Song
In recent years, imaging photoplethysmograph (iPPG) pulse signals have been widely used in the research of non-contact blood pressure (BP) estimation, in which BP estimation based on pulse features is the main research direction. Pulse features are directly related to the shape of pulse signals while iPPG pulse signals are easily disturbed during the extraction process. To mitigate the impact of pulse feature distortion on BP estimation, it is necessary to eliminate interference while retaining valuable shape details in the iPPG pulse signal...
April 1, 2024: Biomedical Optics Express
https://read.qxmd.com/read/38631171/high-frequency-high-power-dnp-epr-spectrometer-operating-at-7%C3%A2-t-magnetic-field
#28
JOURNAL ARTICLE
Alexander A Nevzorov, Antonin Marek, Sergey Milikisiyants, Alex I Smirnov
One of the most essential prerequisites for the development of pulse Dynamic Nuclear Polarization (DNP) is the ability to generate high-power coherent mm-wave pulses at the electron precession frequencies corresponding to the magnetic fields of modern high-resolution NMR spectrometers. As a major step towards achieving this goal, an Extended Interaction Klystron (EIK) pulse amplifier custom-built by the Communications and Power Industries, Inc. and producing up to 140 W at 197.8 GHz, was integrated with in-house built NMR/DNP/EPR spectrometer operating at 7 T magnetic field...
April 10, 2024: Journal of Magnetic Resonance
https://read.qxmd.com/read/38631076/exploring-oxygen-reserve-index-for-timely-detection-of-deoxygenation-in-canine-patients-recovering-from-anesthesia
#29
JOURNAL ARTICLE
Francesca Zanusso, Giulia Maria De Benedictis, Luca Bellini
Pulse oximetry (SpO2 ) identifies a decrease in the partial pressure of oxygen (PaO2 ) when it falls below 80 mmHg, while oxygen reserve index (ORi), a dimensionless index ranging from 0 to 1, detects PaO2 changes between 100 and 200 mmHg. This study investigates the usefulness of ORi in detecting impending deoxygenation before traditional SpO2 . Fifty-one dogs undergoing anesthesia were mechanically ventilated maintaining a fraction of inspired oxygen of 0.50 and an ORi of 1. Animals were classified according to their body condition score (BCS) as normal-fit (BCS 4-5/9), overweight (BCS 6-7/9), or obese (BCS 8-9/9)...
April 13, 2024: Research in Veterinary Science
https://read.qxmd.com/read/38629930/bayesian-plasma-model-selection-for-thomson-scattering
#30
JOURNAL ARTICLE
Jean Luis Suazo Betancourt, Samuel J Grauer, Junhwi Bak, Adam M Steinberg, Mitchell L R Walker
Laser Thomson scattering (LTS) is a measurement technique that can determine electron velocity distribution functions in plasma systems. However, accurately inferring quantities of interest from an LTS signal requires the selection of a plasma physics submodel, and comprehensive uncertainty quantification (UQ) is needed to interpret the results. Automated model selection, parameter estimation, and UQ are particularly challenging for low-density, low-temperature, potentially non-Maxwellian plasmas like those created in space electric propulsion devices...
April 1, 2024: Review of Scientific Instruments
https://read.qxmd.com/read/38627705/no-side-effects-on-rabbit-retina-or-vitreous-microenvironment-by-nd-yag-laser-vitreolysis
#31
JOURNAL ARTICLE
Tiezhu Lin, Mingqin Zhang, Bing Wu, Yuanlong An, Emmanuel Eric Pazo, Rong Li, Lijun Shen
BACKGROUND: To explore the safety of Neodymium:Yttrium-aluminum-garnet (Nd:YAG) laser vitreolysis based on the histological examination of the retina and the alteration of vitreous cytokines in the rabbits. METHODS: Nine male New Zealand rabbits underwent Nd:YAG laser vitreolysis of 10 mJ x 500 pulses in the left eyes, while the right eyes were used as controls. Intraocular pressure, color fundus photography, and ultrasound B scan were measured before, as well as 1 day, 4 weeks, and 12 weeks after Nd:YAG laser vitreolysis...
April 16, 2024: BMC Ophthalmology
https://read.qxmd.com/read/38625764/nonlinear-viscoelastic-modeling-of-finger-arteries-toward-smartphone-based-blood-pressure-monitoring-via-the-oscillometric-finger-pressing-method
#32
JOURNAL ARTICLE
Cederick Landry, Mark Freithaler, Vishaal Dhamotharan, Hadi Daher, Sanjeev G Shroff, Ramakrishna Mukkamala
OBJECTIVE: Oscillometric finger pressing is a smartphone-based blood pressure (BP) monitoring method. Finger photoplethysmography (PPG) oscillations and pressure are measured during a steady increase in finger pressure, and an algorithm computes systolic BP (SP) and diastolic BP (DP) from the measurements. The objective was to assess the impact of finger artery viscoelasticity on the BP computation. METHODS: Nonlinear viscoelastic models relating transmural pressure (finger BP - applied pressure) to PPG oscillations during finger pressing were developed...
April 16, 2024: IEEE Transactions on Bio-medical Engineering
https://read.qxmd.com/read/38616968/defining-ultra-massive-transfusion-through-a-systematic-review
#33
JOURNAL ARTICLE
Courtney H Meyer, Neal Mody Bailey, Sharon L Leslie, Kenya Thrasher, Zach Grady, M Sanders, Erica Moore, K W Nicely, Randi N Smith
BACKGROUND: Despite the widespread use of ultra-massive transfusion (UMT) as an intervention for trauma patients in hemorrhagic shock, no standard definition exists. We performed a systematic review to determine a consensus definition for UMT. METHODS: A search was performed from 1979-2022. The authors screened studies defining UMT and associated outcomes as defined by our prespecified PICO questions. The PRISMA guidelines were used. RESULTS: 1662 articles met criteria for eligibility assessment, 17 for full-text review and eight for data extraction...
February 2024: American Journal of Surgery
https://read.qxmd.com/read/38616511/multi-feature-chinese-western-medicine-integrated-prediction-model-for-diabetic-peripheral-neuropathy-based-on-machine-learning-and-shap
#34
JOURNAL ARTICLE
Aijuan Jiang, Jiajie Li, Lujie Wang, Wenshu Zha, Yixuan Lin, Jindong Zhao, Zhaohui Fang, Guoming Shen
BACKGROUND: Clinical studies have shown that diabetic peripheral neuropathy (DPN) has been on the rise, with most patients presenting with severe and progressive symptoms. Currently, most of the available prediction models for DPN are derived from general clinical information and laboratory indicators. Several Traditional Chinese medicine (TCM) indicators have been utilised to construct prediction models. In this study, we established a novel machine learning-based multi-featured Chinese-Western medicine-integrated prediction model for DPN using clinical features of TCM...
May 2024: Diabetes/metabolism Research and Reviews
https://read.qxmd.com/read/38616032/12-13-dihome-attenuates-high-glucose-induced-calcification-of-vascular-smooth-muscle-cells-through-repressing-cpt1a-mediated-hmgb1-succinylation
#35
JOURNAL ARTICLE
Huahua Li, Lingling Zou, Jin Zheng, Tao Yang
Diabetes is closely associated with vascular calcification (VC). Exorbitant glucose concentration activates pro-calcific effects in vascular smooth muscle cells (VSMCs). This study enrolled 159 elderly patients with type 2 diabetes and divided them into three groups, T1, T2 and T3, according to brachial-ankle pulse wave velocity(BaPWV). There were statistically significant differences in the waist circumference, waist hip ratio, systolic blood pressure, 12,13-diHOME (a lipokin) concentration among T1, T2 and T3...
April 12, 2024: Experimental Cell Research
https://read.qxmd.com/read/38615106/correlations-between-heart-sound-components-and-hemodynamic-variables
#36
JOURNAL ARTICLE
Yong-Seok Park, Hyun-Seok Kim, Seung-Ah Lee, Gyu-Sam Hwang, Woosuk Jung, Baehun Moon, Kyu-Min Kang, Woo-Young Seo, Jun-Gol Song, Sung-Hoon Kim
Although the esophageal stethoscope is used for continuous auscultation during general anesthesia, few studies have investigated phonocardiographic data as a continuous hemodynamic index. In this study, we aimed to induce hemodynamic variations and clarify the relationship between the heart sounds and hemodynamic variables through an experimental animal study. Changes in the cardiac contractility and vascular resistance were induced in anesthetized pigs by administering dobutamine, esmolol, phenylephrine, and nicardipine...
April 13, 2024: Scientific Reports
https://read.qxmd.com/read/38613985/a-new-method-of-pulse-control-in-cardiopulmonary-resuscitation-continuous-femoral-pulse-check
#37
JOURNAL ARTICLE
E Sonmez, B Taslidere, A Ozkan
OBJECTIVES: The reliability of manual pulse checks has been questioned but is still recommended in cardiopulmonary resuscitation (CPR) guidelines. The aim is to compare the 10-s carotid pulse check (CPC) between heart massage cycles with the continuous femoral pulse check (CoFe PuC) in CPR, and to propose a better location to shorten the interruption times for pulse check. METHODS: A prospective study was conducted on 117 Non-traumatic CPR patients between January 2020 and January 2022...
March 31, 2024: American Journal of Emergency Medicine
https://read.qxmd.com/read/38612116/microstructure-and-corrosion-of-mg-based-composites-produced-from-custom-made-powders-of-az31-and-ti6al4v-via-pulse-plasma-sintering
#38
JOURNAL ARTICLE
Anna Dobkowska, Mirosław Jakub Kruszewski, Jakub Ciftci, Bartosz Morończyk, Izabela Zgłobicka, Rafał Zybała, Łukasz Żrodowski
Magnesium (Mg) and its alloys offer promise for aerospace, railway, and 3D technology applications, yet their inherent limitations, including inadequate strength, pose challenges. Magnesium matrix composites, particularly with metallic reinforcements like titanium (Ti) and its alloys, present a viable solution. Therefore, this study investigates the impact of Ti6Al4V reinforcement on AZ31 magnesium alloy composites produced using pulse plasma sintering (PPS). Results show enhanced microhardness of the materials due to improved densification and microstructural refinement...
March 31, 2024: Materials
https://read.qxmd.com/read/38611401/the-effect-of-low-temperature-storage-on-the-lipid-quality-of-fish-either-alone-or-combined-with-alternative-preservation-technologies
#39
REVIEW
María Dolores Suárez-Medina, María Isabel Sáez-Casado, Tomás Martínez-Moya, Miguel Ángel Rincón-Cervera
Marine foods are highly perishable products due to their high content of polyunsaturated fatty acids, which can be readily oxidized to form peroxides and secondary oxidation products, thus conferring such foods undesirable organoleptic characteristics and generating harmful compounds that are detrimental to the health of consumers. The use of preservation methods that minimize lipid oxidation is required in the fishing and aquaculture industries. Low temperature storage (chilling or freezing) is one of the most commonly used preservation methods for fish and seafood, although it has been shown that the oxidation of the lipid fraction of such products is partially but not completely inhibited at low temperatures...
April 3, 2024: Foods (Basel, Switzerland)
https://read.qxmd.com/read/38611136/wear-behavior-of-epoxy-resin-reinforced-with-ceramic-nano-and-microparticles
#40
JOURNAL ARTICLE
Juana Abenojar, Yolanda Ballesteros, Mohsen Bahrami, Miguel Angel Martínez, Juan Carlos Del Real
Cavitation erosion poses a significant challenge in fluid systems like hydraulic turbines and ship propellers due to pulsed pressure from collapsing vapor bubbles. To combat this, various materials and surface engineering methods are employed. In this study, nano and micro scale particles of silicon carbide (SiC) or boron carbide (B4 C) were incorporated as reinforcement at 6% and 12% ratios, owing to their exceptional resistance to abrasive wear and high hardness. Microparticles were incorporated to assess the damage incurred during the tests in comparison to nanoparticles...
March 22, 2024: Polymers
keyword
keyword
38838
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.