Mario Augusto Pereira Dias Chaves, Wilson Takashi Hida, Patrick Frenzel Tzeliks, Michelle Rodrigues Gonçalves, Fernando de Bortoli Nogueira, Celso Takashi Nakano, Antonio Francisco Pimenta Motta, André Gustavo Rolim de Araújo, Milton Ruiz Alves
PURPOSE: To compare the optical performance and visual outcomes between two diffractive multifocal lenses: AMO Tecnis® ZMB00 and AcrySof® ReSTOR® SN6AD1. METHODS: This prospective, non-randomized comparative study included the assessment of 74 eyes in 37 patients referred for cataract surgery and candidates for multifocal intraocular lens implants. Exclusion criteria included existence of any other eye disease, previous eye surgery, high axial myopia, preoperative corneal astigmatism of >1...
May 2016: Arquivos Brasileiros de Oftalmologia
https://www.readbyqxmd.com/read/27135091/analysis-of-defocus-curves-of-different-modern-multifocal-intraocular-lenses
#2
Ana B Plaza-Puche, Jorge L Alio
PURPOSE: To compare the visual performance in patients implanted with different modern multifocal intraocular lens (mfIOL) models using defocus curves. METHODS: This prospective, interventional, comparative, nonrandomized consecutive series of cases included 60 patients (45-87 years) who underwent binocular cataract surgery. Patients were divided into 4 groups depending on the intraocular lens (IOL) implanted after cataract surgery: group A, 15 patients with AT LISA tri 839MP IOL (Carl Zeiss Meditec); group B, 15 patients with FineVision trifocal IOL (PhysIOL); group C, 15 patients with ReSTOR SN6AD1 bifocal IOL (Alcon); and group D, 15 patients with Acri...
August 4, 2016: European Journal of Ophthalmology
https://www.readbyqxmd.com/read/27135090/impact-of-low-mesopic-contrast-sensitivity-outcomes-in-different-types-of-modern-multifocal-intraocular-lenses
#3
Ana B Plaza-Puche, Jorge L Alio, Esperanza Sala, Peter Mojzis
PURPOSE: To investigate the low mesopic contrast sensitivity function (LMCSF) of patients implanted with different modern optical bifocal and trifocal designs of multifocal intraocular lenses (mfIOLs). METHODS: This prospective, comparative, nonrandomized consecutive case series included 180 eyes that underwent cataract surgery. Six groups of eyes were differentiated: group A, eyes with the diffractive AT LISA tri 839MP; group B, eyes with diffractive FineVision; group C, eyes with the bifocal Lentis Mplus-LS313; group D, eyes with the diffractive bifocal Acri...
April 27, 2016: European Journal of Ophthalmology
https://www.readbyqxmd.com/read/26817132/-factors-affecting-uncorrected-visual-acuity-following-implantation-of-apodized-diffractive-intraocular-lenses
#4
Takahisa Koga, Tomoyo Koga
PURPOSE: To investigate the preoperative factors affecting postoperative uncorrected visual acuity (UCVA) equal to or more than 20/20. SUBJECTS AND METHODS: One hundred sixty seven eyes receiving apodized diffractive multifocal intraocular lenses (SN6AD1) were included in this study. In the eyes with corneal astigmatism of less than 1.0 D, a 2.4 mm clear temporal corneal incision was created. In those equal to or more than 1.0 D, 4.1 mm steepest meridian clear corneal incisions and/or limbal relaxing incisions were conducted...
December 2015: Nippon Ganka Gakkai Zasshi
https://www.readbyqxmd.com/read/26544562/straylight-measurements-in-two-different-apodized-diffractive-multifocal-intraocular-lenses
#5
COMPARATIVE STUDY
Ruth Lapid-Gortzak, Grzegorz Labuz, Ivanka J van der Meulen, Jan Willem van der Linden, M P Mourits, Tom J van den Berg
PURPOSE: To evaluate differences in straylight between eyes implanted with a hydrophilic multifocal IOL (Seelens MF; Hanita Lenses, Hanita, Israel) and a hydrophobic multifocal IOL (SN6AD1; Alcon Laboratories, Inc., Fort Worth, TX). METHODS: In a prospective cohort study, routinely obtained straylight measurements (C-Quant; Oculus Optikgeräte, Wetzlar, Germany) 3 months after standard phacoemulsification for either cataract or refractive lens procedures were compared...
November 2015: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/26417927/visual-performance-after-contralateral-implantation-of-multifocal-intraocular-lenses-with-3-0-and-4-0-diopter-additions
#6
Kunihiko Nakamura, Hiroko Bissen-Miyajima, Mami Yoshino, Shinichi Oki
PURPOSE: To evaluate visual performance after contralateral implantation of AcrySof ReSTOR aspheric intraocular lenses (IOLs) with +3.0 and +4.0 diopter near additions. DESIGN: This was a retrospective case study conducted at Tokyo Dental College Suidobashi Hospital in Tokyo, Japan. METHODS: Eleven patients who were implanted with the SN6AD1 IOL and the SN6AD3 IOL contralaterally were included in this study. The distance, intermediate (1 m, 50 cm), and near (40 and 30 cm) uncorrected and corrected binocular visual acuity (VA), contrast sensitivity, depth of focus, and patient satisfaction were assessed more than 1 month postoperatively...
November 2015: Asia-Pacific Journal of Ophthalmology
https://www.readbyqxmd.com/read/25974969/long-term-visual-function-and-patient-satisfaction-after-bilateral-implantation-and-combination-of-two-similar-multifocal-iols
#7
COMPARATIVE STUDY
Rodolfo Mastropasqua, Emilio Pedrotti, Mattia Passilongo, Graziella Parisi, Ivan Marchesoni, Giorgio Marchini
PURPOSE: To evaluate the visual outcome, spectacle independence, and patient satisfaction after implantation of two Acrysof ReSTOR (Alcon Laboratories, Inc., Fort Worth, TX) intraocular lenses (IOLs) with different addition power or their combination in both eyes. METHODS: One hundred twenty eyes of 60 patients with bilateral multifocal IOL implantation were divided into three groups of 20 consecutive patients each: the SV25T0 (the T0 group), the SN6AD1 (the D1 group), or a combination of both the SN6AD1 and SV25T0 (the combined group)...
May 2015: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/25674189/visual-and-optical-performances-of-multifocal-intraocular-lenses-with-three-different-near-additions-6-month-follow-up
#8
Mengmeng Wang, Christine Carole C Corpuz, Megumi Fujiwara, Minoru Tomita
PURPOSE: To compare the visual and optical outcomes of four multifocal intraocular lenses (IOLs) with three different near additions of +3.00 diopters (D), +3.75 D and +4.00 D. METHODS: In this prospective study, 133 eyes of 88 patients were implanted with one of the following IOLs: AcrySof(®) ReSTOR(®) SN6AD1 (+3.00 D) for Group A, Acriva(UD) Reviol BB MF 613 or BB MFM 611 (+3.75 D) for Group B, and AcrySof(®) ReSTOR(®) SN6AD3 (+4.00 D) for Group C. The visual acuity, refraction, intraocular pressure, tomography and corneal endothelial cell density (ECD) were compared between the three groups preoperatively and at 6 month postoperatively...
2015: Open Ophthalmology Journal
https://www.readbyqxmd.com/read/25537197/quality-of-vision-after-bilateral-multifocal-intraocular-lens-implantation-a-randomized-trial-at-lisa-809m-versus-acrysof-restor-sn6ad1
#9
RANDOMIZED CONTROLLED TRIAL
Vincenzo Maurino, Bruce D Allan, Gary S Rubin, Catey Bunce, Wen Xing, Oliver Findl
PURPOSE: To compare postoperative visual symptoms and spectacle freedom after bilateral implantation of the AT LISA 809M (Carl Zeiss Meditec, Jena, Germany) versus the AcrySof ReSTOR SN6AD1 (Alcon Laboratories, Irvine, CA) multifocal intraocular lens (IOL). DESIGN: Double-masked, prospective, randomized, controlled clinical trial. PARTICIPANTS: A total of 188 patients undergoing bilateral sequential cataract surgery or bilateral refractive lens exchange...
April 2015: Ophthalmology
https://www.readbyqxmd.com/read/25491591/accuracy-of-predicted-refraction-with-multifocal-intraocular-lenses-using-two-biometry-measurement-devices-and-multiple-intraocular-lens-power-calculation-formulas
#10
COMPARATIVE STUDY
Olga Reitblat, Ehud I Assia, Guy Kleinmann, Adi Levy, Graham D Barrett, Adi Abulafia
BACKGROUND: To evaluate the accuracy of predicted refraction using multifocal intraocular lenses (IOLs) with power calculation based on two biometric devices and multiple IOL power calculation formulas. DESIGN: A retrospective study conducted in a private practice ophthalmology clinic. PARTICIPANTS: Seventy-three eyes of 48 patients were evaluated. METHODS: Consecutive cases of eyes that had undergone successful cataract surgery with an implantation of a multifocal IOL (SN6AD1, Alcon Laboratories, Inc...
May 2015: Clinical & Experimental Ophthalmology
https://www.readbyqxmd.com/read/25375848/comparison-of-two-multifocal-intraocular-lens-designs-that-differ-only-in-near-add
#11
COMPARATIVE STUDY
Emilio Pedrotti, Rodolfo Mastropasqua, Mattia Passilongo, Graziella Parisi, Ivan Marchesoni, Giorgio Marchini
PURPOSE: To evaluate monocular functional outcomes after the implantation of the AcrySof ReSTOR SN6AD2 intraocular lens (IOL) (+2.5 diopters [D] near add) (Alcon Laboratories, Inc., Fort Worth, TX) and the AcrySof ReSTOR SN6AD1 IOL (+3.0 D near add) (Alcon Laboratories, Inc.). METHODS: This prospective, comparative, nonrandomized single-blind observational study comprised 62 eyes of 62 patients that underwent phacoemulsification and implantation of a multifocal IOL: SN6AD2 (31 eyes) (+2...
November 2014: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/24735662/-comparison-study-of-visual-function-and-patient-satisfaction-in-patients-with-monovision-and-patients-with-bilateral-multifocal-intraocular-lenses
#12
COMPARATIVE STUDY
Jing Mu, Hui Chen, Yizhuang Li
OBJECTIVE: To compare visual function and patient satisfaction in patients with bilateral diffractive multifocal intraocular lenses (IOL) and patients with monofocal IOL monovision. METHODS: Prospective nonrandomized controlled study. This study comprised consecutive bilateral cataract patients 45 cases (90eyes) between January 2011 and March 2012. All cases were divided into two groups: multifocal IOL group (23 patients) having implantation of AcrySof ReSTOR +3D(SN6AD1) multifocal IOL, monovision group (22 patients) having implantation of AcrySof IQ (SN60WF) IOL...
February 2014: [Zhonghua Yan Ke za Zhi] Chinese Journal of Ophthalmology
https://www.readbyqxmd.com/read/24724014/medium-term-visual-outcomes-of-apodized-diffractive-multifocal-intraocular-lens-with-3-00%C3%A2-d-addition-power
#13
Xiaohong Guo, Yi Sun, Bowen Zhang, Danying Zheng
Purpose. To evaluate 2-year visual acuities and questionnaire after bilateral implantation of SN6AD1 multifocal intraocular lens (MIOL) or SN60WF IOL. Methods. Patients randomly scheduled for bilateral implantation of SN6AD1 MIOL and SN60WF IOL with 2-year follow-up were enrolled. Uncorrected/corrected distance and near visual acuity, uncorrected intermediate visual acuity at 63 cm under high and low contrast, reading activity, the defocus curve, and a quality-of-life questionnaire were evaluated. Results...
2014: Journal of Ophthalmology
https://www.readbyqxmd.com/read/24400719/stereo-acuity-in-patients-implanted-with-multifocal-intraocular-lenses-is-the-choice-of-stereotest-relevant
#14
RANDOMIZED CONTROLLED TRIAL
Consuelo Varón, Miguel A Gil, Francisco Alba-Bueno, Genís Cardona, Fidel Vega, María S Millán, José A Buil
PURPOSE: A randomized and double-blinded study design was implemented to assess the stereo-acuity in patients symmetrically implanted with four types of multifocal intraocular lenses (MIOLs), compared to a monofocal lens (control group). In addition, the influence of the type of test employed for the evaluation of stereo-acuity was explored. MATERIALS AND METHODS: Six months after cataract intervention, stereo-acuity was measured with the Titmus and TNO stereotests in 143 patients implanted with one of the following MIOL lens types: hybrid spherical SN60D3, hybrid aspheric SN6AD1, diffractive aspheric ZMA00 and refractive spherical NXG1...
July 2014: Current Eye Research
https://www.readbyqxmd.com/read/24203806/optical-quality-differences-between-three-multifocal-intraocular-lenses-bifocal-low-add-bifocal-moderate-add-and-trifocal
#15
COMPARATIVE STUDY
David Madrid-Costa, Javier Ruiz-Alcocer, Teresa Ferrer-Blasco, Santiago García-Lázaro, Robert Montés-Micó
PURPOSE: To compare the in vitro optical quality at different focal points of two new bifocal intraocular lenses (IOLs) and one new trifocal IOL. METHODS: The AcrySof ReSTOR SV25T0 (+2.5 diopter [D] add) and the AcrySof ReSTOR SN6AD1 (+3.0 D add) with two main foci (Alcon Laboratories, Fort Worth, TX) and the AT LISA tri 839MP with three main foci (Carl Zeiss Meditec, Dublin, CA) were evaluated. The optical quality of the IOLs was measured with the PMTF optical bench (LAMBDA-X, Nivelles, Belgium)...
November 2013: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/24160381/comparison-of-visual-function-after-bilateral-implantation-of-inferior-sector-shaped-near-addition-and-diffractive-refractive-multifocal-iols
#16
COMPARATIVE STUDY
Andreia Martins Rosa, Maria Fátima Loureiro Silva, Conceição Lobo, Joaquim Bernardes Mira, Cláudia Louro Farinha, João Alberto Póvoa, Miguel Castelo-Branco, Joaquim Neto Murta
PURPOSE: To compare visual function after bilateral implantation of multifocal Lentis Mplus LS-312 (Group A) or Acrysof Restor SN6AD1 (Group B) intraocular lenses (IOLs). SETTING: Ophthalmology Unit, Centro Hospitalar e Universitário de Coimbra, and Visual Neuroscience Laboratory, IBILI, Faculty of Medicine, University of Coimbra, Coimbra, Portugal. DESIGN: Comparative case series. METHODS: Patients between 49 years and 76 years had bilateral cataract surgery with multifocal IOL implantation...
November 2013: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/23953097/working-age-cataract-patients-visual-results-reading-performance-and-quality-of-life-with-three-diffractive-multifocal-intraocular-lenses
#17
RANDOMIZED CONTROLLED TRIAL
Giovanni Cillino, Alessandra Casuccio, Mattia Pasti, Valeria Bono, Rita Mencucci, Salvatore Cillino
PURPOSE: To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). DESIGN: Two-center, randomized, prospective, double-masked study. PARTICIPANTS: Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL...
January 2014: Ophthalmology
https://www.readbyqxmd.com/read/23813113/comparison-of-far-and-near-contrast-sensitivity-in-patients-symmetrically-implanted-with-multifocal-and-monofocal-iols
#18
RANDOMIZED CONTROLLED TRIAL
Miguel A Gil, Consuelo Varón, Genís Cardona, Fidel Vega, José A Buil
PURPOSE: A prospective, randomized, double-masked, clinical trial was designed to evaluate distance and near contrast sensitivity (CS) in patients symmetrically, and randomly, implanted with 4 different multifocal intraocular lens (MIOL) designs (ReSTOR SN6AD1, ReSTOR SN60D3, ReZoom NXG, and Tecnis ZMA00) and a monofocal control group (Tecnis ZA9003), 6 months after cataract intervention. METHODS: Photopic, mesopic, and mesopic with glare distance CS, as well as photopic near CS, was evaluated with the CSV-1000 CS test and the Vistech VCTS 6000 system, respectively, in a group of 180 patients attending the ophthalmology department of Sant Pau Hospital, Barcelona, for cataract intervention and lens implantation...
January 2014: European Journal of Ophthalmology
https://www.readbyqxmd.com/read/23692884/comparison-of-bifocal-and-trifocal-diffractive-and-refractive-intraocular-lenses-using-an-optical-bench
#19
COMPARATIVE STUDY
Damien Gatinel, Yvette Houbrechts
PURPOSE: To assess the differences in optical performance of 9 multifocal IOLs using the same optical bench and to propose a possible comparison for surgeons. SETTING: Rothschild Foundation, Paris, France. DESIGN: Experimental study. METHODS: Nine IOLs (Acrysof Restor +3.0 diopter [D] SN6AD1, Acrysof Restor +4.0 D SN60D3, Acrysof aspheric monofocal SN60WF, Acri.Lisa 366D, Finevision Micro F, Tecnis ZM900, and Rezoom, Diffractiva Diff-s, and Lentis Mplus +3...
July 2013: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/23381387/comparison-of-a-hydrophilic-and-a-hydrophobic-apodized-diffractive-multifocal-intraocular-lens
#20
Jan Willem van der Linden, Ivanka J van der Meulen, Maarten P Mourits, Ruth Lapid-Gortzak
UNLABELLED: To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at distance and near. Patient satisfaction with a validated questionnaire, dysphotopsia and straylight measurement scores were recorded at 3 months post-operatively. The study group comprised 48 eyes and the control group 37 eyes...
October 2013: International Ophthalmology
keyword
keyword
33765
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"