keyword
https://read.qxmd.com/read/37436178/comparative-characteristics-of-the-properties-of-dental-implants-depending-on-the-design-shape-and-surface-in-the-experiment
#1
JOURNAL ARTICLE
Dmytro Kaplun, David Avetikov, Кateryna Lokes, Olena Ivanytska
THE AIM OF THE STUDY: Compare the properties of different dental implants depending on the design, shape and surface area in the experiment. MATERIALS AND METHODS: Dental implants with similar sizes (5.5×10 mm) were selected: Vitaplant VPKS, Mega Gen AnyRidge and Alpha Dent Superior Active. The calculation of the total area of the implants was performed and the implants were immersed in a ferromagnetic substance. RESULTS AND DISCUSSION: The small number of turns and their small length of the Vitaplant implant cannot create a large surface area (this size of the implant has an area of 174...
2023: Stomatologija
https://read.qxmd.com/read/36439194/comparing-dual-zone-immediate-implant-placement-and-socket-shield-technique-for-ridge-width-changes-in-the-maxilla-a-prospective-cohort-study
#2
JOURNAL ARTICLE
Rola Muhammad Shadid
PURPOSE: The aim of this prospective cohort study was to assess the facial-palatal ridge dimensional changes that occurred at 8-10 months following flapless dual-zone (DZ) immediate implant placement and socket-shield (SS) immediate placement in the maxilla. MATERIALS AND METHODS: A total of 19 patients who received 20 implants were included, with 10 implants (MegaGen AnyRidge) placed for each treatment, DZ and SS. Cast models were made at 8-10 months after implant placement to assess the dimensional ridge changes by measuring the facial-palatal ridge width on implant sites (T) at six designated points starting from the gingival margin (0, 1, 2, 3, 5 and 7) and comparing it with the corresponding measurement on the contralateral tooth site (C)...
2022: Clinical, Cosmetic and Investigational Dentistry
https://read.qxmd.com/read/35689246/immediate-implant-placement-with-socket-shield-technique-in-the-maxilla-a-prospective-case-series-evaluation-at-1-year-follow-up
#3
JOURNAL ARTICLE
Rola Muhammed Shadid
BACKGROUND: The aims of this case series were to investigate the clinical, radiographic, implant success, complication incidence, esthetic, and patient-reported outcomes of 10 immediately placed implants associated with the socket shield technique at 12 months post-loading and to assess the ridge width changes that occurred at 8 months following implant placement. METHODS: A total of 10 patients received 10 socket shield immediate implants (MegaGen AnyRidge)...
June 10, 2022: Head & Face Medicine
https://read.qxmd.com/read/35456347/case-series-on-the-long-term-effect-of-three-different-types-of-maxillary-implant-supported-overdentures-on-clinical-outcomes-and-complications
#4
JOURNAL ARTICLE
Emitis Natali Naeini, Hugo De Bruyn, Ewald M Bronkhorst, Jan D'haese
(1) Long-term data on maxillary implant overdentures (IODs) are scarce. This case series evaluated three types of IODs supported by six, four or three implants (Anyridge® , Mega'Gen Implant Co., Ltd., Daegu, South-Korea), after 3-5 years in function. (2) A total of 31 patients, with 132 implants, were non-randomly allocated based on available bone or financial limitations. IOD-6 received a telescopic overdenture; IOD-4 a bar; and IOD-3, non-connected implants with locator abutments. Implant survival, bone level changes, probing pocket depth (PPD), plaque index, bleeding on probing (BOP), and technical, biological and aesthetic complications were registered...
April 18, 2022: Journal of Clinical Medicine
https://read.qxmd.com/read/34271405/innovative-implant-design-for-continuous-implant-stability-a-mechanical-and-histological-experimental-study-in-the-iliac-crest-of-goats
#5
JOURNAL ARTICLE
Jan Willem M Hoekstra, Bart Aja van Oirschot, John A Jansen, Jeroen Jjp van den Beucken
OBJECTIVES: this in vivo study reports on mechanical torque data as well as the biological evaluation up to 6 weeks after placement of implants with a unique wide knife thread design in a goat iliac crest model. We hypothesized that implants with this thread design would show substantial primary stability at a continuous level toward secondary stability. METHODS: 64 MegaGen Anyridge® implants were used with diameters 3.5 mm, 4.0 mm, 5.0 mm and 6.0 mm (n = 8)...
June 23, 2021: Journal of the Mechanical Behavior of Biomedical Materials
https://read.qxmd.com/read/32066431/influence-of-the-implant-abutment-connection-on-the-ratio-between-height-and-thickness-of-tissues-at-the-buccal-zenith-a-randomized-controlled-trial-on-188-implants-placed-in-104-patients
#6
JOURNAL ARTICLE
Davide Farronato, Pietro Mario Pasini, Mattia Manfredini, Cristian Scognamiglio, Andrea Alain Orsina, Marco Farronato
BACKGROUND: To compare tissue response to two implant systems, featuring internal hexed connections with different designs. METHODS: Patients enrolled in this randomized controlled trial were assigned to two groups. In Group 1, patients were treated with implants with a 5° conical internal hexed connection (Anyridge®, MegaGen, South Korea). In Group 2, patients were treated with implants with an internal hexed connection (Core®, Kristal, Italy). After implant placement and a provisionalisation period of 12 months, impressions were taken, stone casts were poured and digitised with a desktop scanner (D700®, 3Shape, Copenhagen, Denmark)...
February 17, 2020: BMC Oral Health
https://read.qxmd.com/read/31382675/factors-influencing-early-marginal-bone-loss-around-dental-implants-positioned-subcrestally-a-multicenter-prospective-clinical-study
#7
JOURNAL ARTICLE
Teresa Lombardi, Federico Berton, Stefano Salgarello, Erika Barbalonga, Antonio Rapani, Francesca Piovesana, Caterina Gregorio, Giulia Barbati, Roberto Di Lenarda, Claudio Stacchi
Early marginal bone loss (MBL) is a non-infective remodeling process of variable entity occurring within the first year after implant placement. It has a multifactorial etiology, being influenced by both surgical and prosthetic factors. Their impact remains a matter of debate, and controversial information is available, particularly regarding implants placed subcrestally. The present multicenter prospective clinical study aimed to correlate marginal bone loss around platform-switched implants with conical connection inserted subcrestally to general and local factors...
August 4, 2019: Journal of Clinical Medicine
https://read.qxmd.com/read/30987026/ratio-between-height-and-thickness-of-the-buccal-tissues-a-pilot-study-on-32-single-implants
#8
JOURNAL ARTICLE
Davide Farronato, Mattia Manfredini, Francesco Mangano, Giada Goffredo, Marco Colombo, Pietro Pasini, Andrea Orsina, Marco Farronato
BACKGROUND: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching. METHODS: All patients receiving single implants (Anyridge® , MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study...
April 2, 2019: Dentistry Journal
https://read.qxmd.com/read/29862286/correlation-between-insertion-torque-and-implant-stability-quotient-in-tapered-implants-with-knife-edge-thread-design
#9
MULTICENTER STUDY
Domenico Baldi, Teresa Lombardi, Jacopo Colombo, Gabriele Cervino, Giuseppe Perinetti, Roberto Di Lenarda, Claudio Stacchi
Aim: To evaluate the correlation between insertion torque (IT) and implant stability quotient (ISQ) in tapered implants with knife-edge threads. Methods: Seventy-five identical implants (Anyridge, Megagen) were inserted by using a surgical drilling unit with torque control and an integrated resonance frequency analysis module (Implantmed, W&H). IT (N/cm) and ISQ were recorded and implants were divided into three groups ( n = 25) according to the IT: low (<30), medium (30 < IT < 50), and high torque (>50)...
2018: BioMed Research International
https://read.qxmd.com/read/29732018/immediate-functional-loading-of-single-implants-a-multicenter-study-with-4-years-of-follow-up
#10
JOURNAL ARTICLE
Filiep Raes, Tammaro Eccellente, Carolina Lenzi, Michele Ortolani, Giuseppe Luongo, Carlo Mangano, Francesco Mangano
Background. In the current scientific literature there are only few studies on the immediate functional loading of single implants. The aim of the present present study was to evaluate the 4-year survival rate, complication rate and peri-implant marginal bone loss (PIMBL) of immediately loaded single implants inserted in healed ridges and fresh post-extraction sites. Methods. Six centers were involved in this prospective study. The surgical and prosthetic protocol was defined in detail, before the start of recruiting patients...
2018: Journal of Dental Research, Dental Clinics, Dental Prospects
https://read.qxmd.com/read/29258208/scanning-electron-microscope-sem-evaluation-of-the-interface-between-a-nanostructured-calcium-incorporated-dental-implant-surface-and-the-human-bone
#11
JOURNAL ARTICLE
Francesco Mangano, Mario Raspanti, Hassan Maghaireh, Carlo Mangano
Purpose . The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods . A dental implant (Anyridge® , Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed® , Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury...
December 17, 2017: Materials
https://read.qxmd.com/read/28626763/implant-stability-in-the-posterior-maxilla-a-controlled-clinical-trial
#12
JOURNAL ARTICLE
Raquel Zita Gomes, Mario Ramalho de Vasconcelos, Isabel Maria Lopes Guerra, Rute Alexandra Borges de Almeida, Antonio Cabral de Campos Felino
AIM: To evaluate the primary and secondary stability of implants in the posterior maxilla. METHODS: Patients were allocated into three groups: (A) native bone, (B) partially regenerated bone, and (C) nearly totally regenerated bone. Insertion torque (IT) and implant stability quotient (ISQ) were measured at placement, to evaluate whether satisfactory high primary stability (IT ≥ 45 N/cm; ISQ ≥ 60) was achieved; ISQ was measured 15, 30, 45, and 60 days after placement, to investigate the evolution to secondary stability...
2017: BioMed Research International
https://read.qxmd.com/read/28611844/immediate-loading-of-single-implants-in-the-anterior-maxilla-a-1-year-prospective-clinical-study-on-34-patients
#13
JOURNAL ARTICLE
Miguel Stanley, Filipa Calheiros Braga, Beatriz Mota Jordao
PURPOSE: To present the outcomes of immediately loaded single implants placed in the anterior maxilla. METHODS: Over a 2-year period, all patients referred to a private clinic were considered for enrolment in this study. Inclusion criteria were single-tooth placement in postextraction sockets or healed sites of the anterior maxilla. All implants were immediately loaded and followed for a period of 1 year after the placement of definitive crowns. The outcome measures were implant stability, survival, and success...
2017: International Journal of Dentistry
https://read.qxmd.com/read/28280731/early-bone-formation-around-immediately-loaded-transitional-implants-inserted-in-the-human-posterior-maxilla-the-effects-of-fixture-design-and-surface
#14
RANDOMIZED CONTROLLED TRIAL
Carlo Mangano, Jamil Awad Shibli, Jefferson Trabach Pires, Giuseppe Luongo, Adriano Piattelli, Giovanna Iezzi
Aim. To evaluate the effects of fixture design and surface on the early bone formation around immediately loaded implants inserted in the human posterior maxilla. Materials and Methods. Ten totally edentulous subjects received two transitional implants: one tapered implant with knife-edge threads/nanostructured calcium-incorporated surface (test: Anyridge®, Megagen, Gyeongbuk, South Korea) and one cylindrical implant with self-tapping threads/sandblasted surface (control: EZPlus®, Megagen). The implants were placed according to a split-mouth design and immediately loaded to support an interim complete denture; after 8 weeks, they were removed for histologic/histomorphometric analysis...
2017: BioMed Research International
https://read.qxmd.com/read/28246595/fixed-full-arches-supported-by-tapered-implants-with-knife-edge-thread-design-and-nanostructured-calcium-incorporated-surface-a-short-term-prospective-clinical-study
#15
JOURNAL ARTICLE
Soheil Bechara, Algirdas Lukosiunas, Giorgio Andrea Dolcini, Ricardas Kubilius
Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program...
2017: BioMed Research International
https://read.qxmd.com/read/27699890/the-effect-of-implant-macro-thread-design-on-implant-stability-in-the-early-post-operative-period-a-randomized-controlled-pilot-study
#16
RANDOMIZED CONTROLLED TRIAL
Jeffrey J McCullough, Perry R Klokkevold
INTRODUCTION: Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. AIM: The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA)...
October 2017: Clinical Oral Implants Research
https://read.qxmd.com/read/27443360/chemical-and-topographic-analysis-of-eight-commercially-available-dental-implants
#17
JOURNAL ARTICLE
Mogammad T Peck, Bruno R Chrcanovic
BACKGROUND: Surface characterization of dental implants allows us to better understand the effects of the implant on the host biological response. In this study, we analyzed and compared these characteristics among implants commercially available in South Africa. MATERIALS AND METHODS: Eight implants from different manufacturers were chosen for analysis (Touareg, ICE, (R)Evolutions, Uniti, AnyRidge, MIS, Ivory-QSI, Southern), using scanning electron microscopy (SEM), interferometry, and energy dispersive X-ray spectroscopy to study the surface chemical composition and morphology...
May 1, 2016: Journal of Contemporary Dental Practice
https://read.qxmd.com/read/27402427/short-6-mm-dental-implants-versus-sinus-floor-elevation-and-placement-of-longer-%C3%A2-10-mm-dental-implants-a-randomized-controlled-trial-with-a-3-year-follow-up
#18
RANDOMIZED CONTROLLED TRIAL
Souheil Bechara, Ricardas Kubilius, Giovanni Veronesi, Jefferson T Pires, Jamil A Shibli, Francesco G Mangano
OBJECTIVES: To investigate whether short (6-mm) dental implants could be an alternative to sinus floor elevation (SFE) and placement of longer (≥10-mm) implants in the posterior maxilla. MATERIALS AND METHODS: Over a 3-year period, all patients presenting with partial edentulism in the posterior maxilla were considered for inclusion in this randomized controlled trial. Patients were randomly chosen either to receive short (6-mm) implants (test group [TG]) or to undergo SFE with simultaneous placement of standard-length (≥10-mm) implants (control group [CG])...
September 2017: Clinical Oral Implants Research
https://read.qxmd.com/read/27298621/soft-tissue-stability-around-single-implants-inserted-to-replace-maxillary-lateral-incisors-a-3d-evaluation
#19
JOURNAL ARTICLE
F G Mangano, F Luongo, G Picciocchi, C Mortellaro, K B Park, C Mangano
Purpose. To evaluate the soft tissue stability around single implants inserted to replace maxillary lateral incisors, using an innovative 3D method. Methods. We have used reverse-engineering software for the superimposition of 3D surface models of the dentogingival structures, obtained from intraoral scans of the same patients taken at the delivery of the final crown (S1) and 2 years later (S2). The assessment of soft tissues changes was performed via calculation of the Euclidean surface distances between the 3D models, after the superimposition of S2 on S1; colour maps were used for quantification of changes...
2016: International Journal of Dentistry
https://read.qxmd.com/read/26064701/custom-made-computer-aided-design-computer-aided-manufacturing-biphasic-calcium-phosphate-scaffold-for-augmentation-of-an-atrophic-mandibular-anterior-ridge
#20
JOURNAL ARTICLE
Francesco Guido Mangano, Piero Antonio Zecca, Ric van Noort, Samvel Apresyan, Giovanna Iezzi, Adriano Piattelli, Aldo Macchi, Carlo Mangano
This report documents the clinical, radiographic, and histologic outcome of a custom-made computer-aided-design/computer-aided-manufactured (CAD/CAM) scaffold used for the alveolar ridge augmentation of a severely atrophic anterior mandible. Computed tomographic (CT) images of an atrophic anterior mandible were acquired and modified into a 3-dimensional (3D) reconstruction model; this was transferred to a CAD program, where a custom-made scaffold was designed. CAM software generated a set of tool-paths for the manufacture of the scaffold on a computer-numerical-control milling machine into the exact shape of the 3D design...
2015: Case Reports in Dentistry
keyword
keyword
33716
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.