keyword
MENU ▼
Read by QxMD icon Read
search

Xive

keyword
https://www.readbyqxmd.com/read/28413592/marginal-bone-loss-around-platform-switched-and-non-platform-switched-implants-after-two-years-of-placement-a-clinical-trial
#1
Ali Zarandi, Maryam Novin
Background. The present study was conducted to investigate the marginal bone loss around two different types of implant‒abutment junctions, called platform-switched (Implantium system) and non-platform switched (XiVE system) after two years of loading. Methods. Sixty-four implants in 49 patients were included in the study. The implants were placed in the posterior mandibular region according to the relevant protocols. The extent of bone loss around the implants was measured and compared after 24 months, using digital parallel periapical radiographs...
2017: Journal of Dental Research, Dental Clinics, Dental Prospects
https://www.readbyqxmd.com/read/28334057/esthetic-and-patient-centered-outcomes-of-single-implants-a-retrospective-study
#2
Björn Gjelvold, Bruno Ramos Chrcanovic, Ingrid Collin Bagewitz, Jenö Kisch, Tomas Albrektsson, Ann Wennerberg
PURPOSE: The aims of this clinical study were to retrospectively evaluate implant survival, patient satisfaction, and radiographic, clinical, and esthetic outcomes following single-implant treatment. MATERIALS AND METHODS: Eighty-seven patients, with a total of 126 implants (XiVE S, Dentsply Implants), who received single implant-retained crowns between 2004 and 2011 were retrospectively evaluated. Implant survival, marginal bone levels (MBL), changes in implant/mesial tooth vertical relationship, pink esthetic score (PES), white esthetic score (WES), patient assessment of the esthetics (visual analog scale), and oral health impact profile (OHIP-14) were evaluated...
March 23, 2017: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/28149455/the-influence-of-length-of-implant-on-primary-stability-an-in-vitro-study-using-resonance-frequency-analysis
#3
Anwar B Bataineh, Ala M Al-Dakes
BACKGROUND: Primary stabilityis not sufficientin less contact area between the implant and bone, the healing process because will be disrupted due to micro-motions and fibrous tissue affects osseointegration. MATERIAL AND METHODS: We implemented an in vitro experimental study of total 135 XiVE® implants were inserted in 22.5 bovine cow ribs with bone quality similar to a type IV human bone. Each rib end received a group of three different implant lengths, which were 8mm, 13mm and 15mm and had the same diameter 3...
January 2017: Journal of Clinical and Experimental Dentistry
https://www.readbyqxmd.com/read/27999789/marginal-bone-level-evaluation-after-functional-loading-around-two-different-dental-implant-designs
#4
Ko-Ning Ho, Eisner Salamanca, Hsi-Kuai Lin, Sheng-Yang Lee, Wei-Jen Chang
Purpose. To investigate peri-implant alveolar bone changes using periapical radiographs before and after prosthetic delivery in submerged and nonsubmerged dental implants. Methods. Digital periapical films of 60 ITI Straumann nonsubmerged dental implants and 60 Xive Dentsply submerged dental implants were taken before, immediately after, and 12 and 24 weeks after the prosthetic restoration was delivered. Results. The 60-nonsubmerged dental implant group showed mean marginal bone resorption at baseline of 0...
2016: BioMed Research International
https://www.readbyqxmd.com/read/27538921/correlation-between-resonance-frequency-insertion-torque-and-bone-implant-contact-in-self-cutting-threaded-implants
#5
Yahya Açil, Jan Sievers, Aydin Gülses, Mustafa Ayna, Jörg Wiltfang, Hendrik Terheyden
The aim of this study was to evaluate the correlation between resonance frequency analysis (RFA) values and the histomorphometric bone-implant contact (BIC) immediately after insertion of the implant. Additionally, it was examined to define which extent peak insertion torque (PIT) was correlated with the latter measurements. 15 Xive(®) S plus root from dental implants were inserted in fresh porcine frontal bones. The insertion torque was measured with the Kavo Intrasurg 300 surgical unit. RFA connector was coupled to the implants and the mean value of 20 consecutive RFA measurements was calculated via Osstell(®) ISQ device...
August 18, 2016: Odontology
https://www.readbyqxmd.com/read/27183065/transfer-of-bacteria-into-the-internal-cavity-of-dental-implants-after-application-of-disinfectant-or-sealant-agents-in-vitro
#6
Anke Podhorsky, Stefanie Biscoping, Peter Rehmann, Philipp Streckbein, Eugen Domann, Bernd Wöstmann
PURPOSE: Bacterial colonization of the inner part of dental implants has been reported in numerous studies. The aim of this in vitro study was to analyze the bacterial colonization of the implant lumen of two implant systems that were partly subjected to a thermal cycling regimen after three different approaches to reducing bacterial load: filling of the hollow parts with either a disinfectant agent, a setting sealing compound, or a nonsetting sealing compound. MATERIALS AND METHODS: Two implant systems with internal connections (the Bego Semados RI implant, Bego, and the Xive S Plus Screw Implant, Dentsply) were used in this study...
May 2016: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/26249208/effect-of-double-conical-abutment-screw-on-implant-preload
#7
Gerwin Vincent Arnetzl, Michael Payer, Frank Falkensammer, Gerwin Arnetzl
OBJECTIVE: This study compared the loosening torque of experimental double conical abutment screws to that of conventional conical abutment screws and flat-head screws in implants with internal connections before and after mechanical loading. MATERIAL AND METHODS: Eighty implant-screw-abutment assemblies were divided into four groups: flat-head screw (Xive S), conical screw (Straumann), conical screw (Nobel Biocare), and double conical screw (RTB). Abutments were tightened to a torque of 30 Ncm...
May 2016: Clinical Oral Implants Research
https://www.readbyqxmd.com/read/26096295/10-year-prospective-cohort-follow-up-of-immediately-restored-xive-implants
#8
Marco Degidi, Diego Nardi, Adriano Piattelli
OBJECTIVE: The aim of this prospective cohort study was to assess the ten-year performance of the condensing thread, self-tapping apex and internal hexagonal connection XiVE implant supporting partial fixed prostheses placed with an immediate restoration approach. MATERIAL AND METHODS: All patients received a fixed two- to four-unit partial provisional restoration supported by immediately loaded implants. The final gold alloy/ceramic restorations were cemented approximately 28 weeks after implant insertion...
June 2016: Clinical Oral Implants Research
https://www.readbyqxmd.com/read/25672384/effect-of-using-nano-and-micro-airborne-abrasive-particles-on-bond-strength-of-implant-abutment-to-prosthesis
#9
COMPARATIVE STUDY
Mansour Rismanchian, Amin Davoudi, Elham Shadmehr
Connecting prostheses to the implant abutments has become a concern and achieving a satisfactory retention has been focused in cement-retention prostheses recently. Sandblasting is a method to make a roughened surface for providing more retention. The aim of this study was to compare effects of nano and micro airborne abrasive particles (ABAP) in roughening surface of implant abutments and further retention of cemented copings. Thirty Xive abutments and analogues (4.5 D GH1) were mounted vertically in self-cured acrylic blocks...
January 2015: Brazilian Dental Journal
https://www.readbyqxmd.com/read/25216149/effect-of-estrogen-deficiency-on-implant-osseointegration-in-dogs
#10
COMPARATIVE STUDY
Nan Hua, Yuanzhi Xu, Xioashan Tang, Guangwei Shang, Yun Shen, Raorao Wang
PURPOSE: This study investigated the effect of the absence of estrogen on the process of implant osseointegration in the jaws of beagle dogs. MATERIALS AND METHODS: Of eight beagle dogs, four underwent bilateral ovariectomy (OVX), and the other four constituted a control group. Twelve weeks postsurgery, XiVE implants (Dentsply) were placed in the second premolar site in the mandible and in the canine site in the maxilla. Zero, 4, 8, 12, and 16 weeks after implant placement, implant stability quotients (ISQs) were measured by resonance frequency analysis (RFA)...
September 2014: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/24995411/a-7-year-prospective-radiographic-evaluation-of-marginal-bone-level-around-two-different-implant-systems-a-randomized-clinical-trial
#11
Doris Burtscher, Burkhard Norer, Daniel Dalla Torre, Ulrike Beier, Katharina Schubert, Ingrid Grunert
OBJECTIVE: The aim of this study was to evaluate the change in marginal bone level radiographically around two different implant systems after 7 years of use. MATERIAL AND METHODS: Twenty fully edentulous patients were included in the study and randomly assigned to two treatment groups of machined surface implants (Brånemark, n = 40) and rough-surface implants (Xive, n = 40). The implants were early loaded with individual bar-retained overdentures. All patients were treated by the same surgeon and the same prosthodontist...
November 2015: Clinical Oral Implants Research
https://www.readbyqxmd.com/read/24843205/clinical-evaluation-of-immediate-implants-using-different-types-of-bone-augmentation-materials
#12
M Viswambaran, Vimal Arora, R C Tripathi, R K Dhiman
BACKGROUND: The immediate placement of implants into fresh extraction socket has proven to be a safe and predictable procedure. However, there is lack of scientific evidence regarding the healing pattern and osseointegration associated with immediate implants especially with different grafting materials. METHODS: A total of 30 patients male or female, with a mean age of 23.1 years ± 6.0 in the age group of 18-38 years, each having at least one tooth indicated for extraction (either maxillary or mandibular anterior teeth) were selected and randomly divided in to two groups...
April 2014: Medical Journal, Armed Forces India
https://www.readbyqxmd.com/read/24396353/biomechanical-effects-of-platform-switching-in-two-different-implant-systems-a-three-dimensional-finite-element-analysis
#13
Mahasti Sahabi, Mehdi Adibrad, Fatemeh Sadat Mirhashemi, Sareh Habibzadeh
OBJECTIVES: The purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3D) finite element models. MATERIALS AND METHODS: Six 3D finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were represented: model XiVE-a: 3.8-mm-diameter implant and 3.8-mm-diameter abutment; model XiVE-b (platform-switching model): 4...
May 2013: Journal of Dentistry of Tehran University of Medical Sciences
https://www.readbyqxmd.com/read/24313278/mechanical-resistance-of-screwless-morse-taper-and-screw-retained-implant-abutment-connections
#14
COMPARATIVE STUDY
Cihan Sadi Ugurel, Martin Steiner, Gul Isik-Ozkol, Omer Kutay, Matthias Kern
OBJECTIVE: The screwless morse taper (SMT) implant-abutment connection is an alternative to conventional external or internal screw-retained (ISR) connections. The aim of this in vitro study was to evaluate mechanical resistance of the SMT connection and to compare it with three different ISR connections. MATERIALS AND METHODS: Four implant systems were tested in this study: SMT system; Tasarimmed Octo (Istanbul, Turkey), ISR systems; Straumann Bone Level (Basel, Switzerland), Biohorizons Internal (Birmingham, AL, USA), and Dentsply Friadent Xive (Mannheim, Germany)...
February 2015: Clinical Oral Implants Research
https://www.readbyqxmd.com/read/24304290/pre-fabricated-zirconium-dioxide-implant-abutments-for-single-tooth-replacement-in-the-posterior-region-success-and-failure-after-3-years-of-function
#15
Frank P Nothdurft, Joerg Nonhoff, Peter R Pospiech
OBJECTIVE: Zirconia implant abutments have gained a much broader clinical use over the past few years. The aim of the present study was to assess the clinical performance of a pre-fabricated zirconium dioxide implant abutment for single-tooth replacement in the posterior region. MATERIALS AND METHODS: Forty implants of the XiVE(®) S plus screw type (DENTSPLY Friadent, Mannheim, Germany) were inserted in the posterior region of 24 patients and provided with zirconium dioxide abutments (FRIADENT(®) CERCON(®) Abutment, DENTSPLY Friadent)...
July 2014: Acta Odontologica Scandinavica
https://www.readbyqxmd.com/read/24278925/correction-of-buccal-dehiscence-at-the-time-of-implant-placement-without-barrier-membranes-a-retrospective-cone-beam-computed-tomographic-study
#16
Arthur Rodriguez Gonzalez Cortes, Djalma Nogueira Cortes, Emiko Saito Arita
PURPOSE: To assess the clinical and tomographic findings of a grafting approach without barrier membranes to treat peri-implant buccal bone dehiscences at the time of implant placement. MATERIALS AND METHODS: This retrospective study was conducted on all patients who needed implant placement with buccal bone grafting and were treated consecutively between March 2007 and June 2010. Two different implant systems were used (PSI, Globtek; XiVE Plus, Dentsply/Friadent)...
November 2013: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/23873839/synthesis-and-biological-evaluation-of-a-novel-series-of-6-8-dibromo-4-3h-quinazolinone-derivatives-as-anticancer-agents
#17
Marwa F Ahmed, Mahmoud Youns
Three novel series of 6,8-dibromo-4(3H)quinazolinone derivatives were synthesized. Some of the novel quinazolinone derivatives were tested for their antitumor activity against the human breast carcinoma cell line MCF-7. Compounds XIIIb, IX, XIVd, XIVb, XIVe, XIIIa, XIVc, XVc, and XIVa exerted powerful cytotoxic effects against the MCF7 cells, with very low IC50 values compared to doxorubicin (positive control). The IC50 values were 1.7, 1.8, 1.83, 5.4, 6.84, 10.8, 13.9, 15.7, and 29.6 µg/mL, respectively...
August 2013: Archiv der Pharmazie
https://www.readbyqxmd.com/read/23552794/-osteotome-sinus-floor-elevation-technique-without-grafting-material-clinical-analysis-of-eight-cases
#18
Nan Hua, Guang-hui Yi
PURPOSE: To study the clinical results of XIVE implants placed immediately after sinus floor elevation using osteotomes without bone grafting. METHODS: Totally 14 XIVE implants were placed in 8 patients immediately after sinus floor elevation using osteotomes without bone grafting. The survival rates of the implants during the prosthodontic process and six months after the crowns fabricated were recorded and analyzed. RESULTS: One implant was loosen and extracted during the prosthodontic process and no implant failed six months after the crowns were placed...
February 2013: Shanghai Kou Qiang Yi Xue, Shanghai Journal of Stomatology
https://www.readbyqxmd.com/read/23527950/retentive-strength-of-two-piece-cad-cam-zirconia-implant-abutments
#19
Peter Gehrke, Jochen Alius, Carsten Fischer, Kurt J Erdelt, Florian Beuer
PURPOSE: The purpose of this study is to evaluate the retention of two-piece computer-aided design (CAD)/computer aided manufacturing (CAM) zirconia abutments after artificial aging under simulated oral conditions using three different types of resin-based luting agents. MATERIAL AND METHODS: Twenty-one CAD/CAM-generated zirconia copings (CERCON Compartis, Degudent, Hanau, Germany) were bonded to a prefabricated secondary titanium implant insert (XiVE Ti-Base, Dentsply Friadent, Mannheim, Germany), using three different types of resin-based luting agents: group A: Panavia 21 (Kuraray Co, Kurashiki, Japan); group B: Multilink Implant (Ivoclar Vivadent, Schaan, Liechtenstein); and group C: SmartCem2 (Dentsply DeTrey, Konstanz, Germany)...
December 2014: Clinical Implant Dentistry and related Research
https://www.readbyqxmd.com/read/23295126/bone-healing-with-or-without-platelet-rich-plasma-around-four-different-dental-implant-surfaces-in-beagle-dogs
#20
RANDOMIZED CONTROLLED TRIAL
Philipp Streckbein, Wilfried Kleis, Rainer S R Buch, Torsten Hansen, Gernot Weibrich
PURPOSE: Surface development is one of the major aims in dental implant engineering. Additive application of substances could possibly improve the new bone formation around dental implants. The present study evaluated the bone reaction on four different implant surfaces with or without platelet-rich plasma (PRP). MATERIALS AND METHODS: Four self-tapping titanium screw implants (Brånemark MK III [Nobel Biocare, Göteborg, Sweden], Osseotite [3i, Miami, FL, USA], Xive [Densply Friadent, Mannheim, Germany], and Compress [IGfZ eG, Diez, Germany]) with different surfaces were inserted in each hemimandible of 12 female beagle dogs; the implant positions and the application of PRP were randomized...
August 2014: Clinical Implant Dentistry and related Research
keyword
keyword
31051
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"