keyword
MENU ▼
Read by QxMD icon Read
search

Transcatheter valve

keyword
https://www.readbyqxmd.com/read/28820553/is-transcatheter-tricuspid-valve-in-valve-implantation-feasible-in-the-presence-of-right-atrial-thrombus
#1
Jan Henzel, Zofia Dzielińska, Marek Konka, Maciej Dąbrowski, Marcin Protasiewicz, Adam Witkowski, Marcin Demkow
The case is reported of a successful transcatheter implantation of an Edwards SAPIEN 3 valve (29 mm) into a failing tricuspid bioprosthesis (Sorin Pericarbon, 31 mm). The procedure was performed in a 69-year-old woman with post-rheumatic mitral and tricuspid valve disease. Multiple previous cardiac surgeries precluded the use of another surgical approach. A large, organized, two-piece thrombus in the enlarged right atrium was not considered an absolute contraindication to the procedure. The SAPIEN 3 valve was implanted under general anesthesia, via a femoral venous access, under three-dimensional transesophageal echocardiography guidance...
March 2017: Journal of Heart Valve Disease
https://www.readbyqxmd.com/read/28820543/minimally-invasive-versus-transcatheter-and-surgical-aortic-valve-replacement-a-propensity-matched-study
#2
Matthew D Terwelp, Vinod H Thourani, Yelin Zhao, Prakash Balan, Catalin Loghin, Daniel Ocazionez, Anthony Estrera, Carson T Hoffmann, Vasilis C Babaliaros, Joseph Lamelas, Tom C Nguyen
BACKGROUND: An increasing number of options exist for the treatment of severe symptomatic aortic stenosis. The study aim was to compare short-term outcomes in patients undergoing surgical aortic valve replacement (SAVR), minimally invasive aortic valve replacement (MIAVR), and transcatheter aortic valve replacement (TAVR). METHODS: A multi-institutional retrospective review of 2,571 patients undergoing SAVR (n = 842), MIAVR via right anterior thoracotomy (n = 699) and TAVR (n = 1,030) between 2011 and 2014 was conducted...
March 2017: Journal of Heart Valve Disease
https://www.readbyqxmd.com/read/28820542/efficacy-and-complications-of-transcatheter-aortic-valve-implantation-with-and-without-balloon-aortic-valvuloplasty
#3
Kuljit Singh, Kristin Carson, Onn Akbar Ali, Rohan Jayasinghe, Alexander Dick, Christopher Glover, Marino Labinaz
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an effective treatment for severe aortic stenosis in high-risk patients. Several complications related to the TAVI procedure, including aortic regurgitation (AR), cerebrovascular accident (CVA) and the requirement for permanent pacemaker (PPM), are thought to be secondary to balloon aortic valvuloplasty (BAV) before TAVI. The aim of the present review was to evaluate any beneficial role of the direct TAVI approach over BAVTAVI...
March 2017: Journal of Heart Valve Disease
https://www.readbyqxmd.com/read/28820541/automatic-estimation-of-optimal-deployment-of-transcatheter-aortic-valve-implantation-using-computed-tomography
#4
Arthur Kerner, Sobhi Abadi, Roy Dotan, Marcia Javitt, Doron Aronson, Jonathan Lessick
BACKGROUND: A comparison was made between the accuracy of and time saved by using novel automated software for pre-procedural computed tomography (CT) planning before transcatheter aortic valve implantation (TAVI) and manual methods. Preprocedural CT to assess aortic annulus dimensions and predict the optimal C-arm implant angle before TAVI can reduce complications related to incorrect prosthesis sizing and positioning. METHODS: A total of 61 consecutive patients underwent TAVI using either the SAPIEN XT or CoreValve prosthesis...
March 2017: Journal of Heart Valve Disease
https://www.readbyqxmd.com/read/28820030/epidemiology-of-cardiovascular-disease-in-the-united-states-implications-for-the-perfusion-profession-a-2017-update
#5
Joseph J Sistino, David C Fitzgerald
INTRODUCTION: By analyzing epidemiological trends in cardiovascular disease (CVD), key stakeholders can make informed decisions on the future of disease burden and treatment. Accordingly, the cardiovascular perfusion community would benefit from data that would help predict future professional resource utilization. METHODS: In 2003, the changes in the number of hospital discharges for CVD from 1990 to 2000 were published, based on data from the National Center for Health Statistics (NCHS)...
September 2017: Perfusion
https://www.readbyqxmd.com/read/28819953/impact-of-post-dilatation-on-the-reduction-of-paravalvular-leak-and-mortality-after-transcatheter-aortic-valve-implantation
#6
Paweł Kleczyński, Artur Dziewierz, Marzena Daniec, Maciej Bagieński, Łukasz Rzeszutko, Danuta Sorysz, Jarosław Trębacz, Robert Sobczyński, Marek Tomala, Dariusz Dudek
BACKGROUND: Post-implantation paravalvular leak (PVL) remains a significant complication of transcatheter aortic valve implantation (TAVI). More importantly, its occurrence may impact long-term mortality. AIM: We sought to evaluate the effects of balloon post-dilatation (PD) on the reduction of PVL and mortality in patients undergoing TAVI. METHODS: A total of 101 consecutive patients undergoing TAVI were enrolled. Angiography, echocardiography, and the aortic regurgitation index (ARI) were used to assess the severity of PVL before and after balloon PD...
2017: Kardiologia Polska
https://www.readbyqxmd.com/read/28818562/conduction-recovery-and-avoidance-of-permanent-pacing-after-transcatheter-aortic-valve-implantation
#7
Corinne Marzahn, Cornel Koban, Martin Seifert, Akihiro Isotani, Michael Neuß, Frank Hölschermann, Christian Butter
BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe aortic stenosis and high surgical risk. Currently, various prosthesis types are available. Atrioventricular block (AVB) requiring pacemaker (PM) implantation is a typical complication after TAVI. This study investigated the recovery of AV node conduction and mid-term outcome of patients with or without PM implantation after TAVI according to prosthesis type. METHODS: From July 2008 to May 2015, 856 transcatheter heart valves were implanted at our center (age: 80...
August 14, 2017: Journal of Cardiology
https://www.readbyqxmd.com/read/28818190/aortic-bioprosthetic-valve-durability-incidence-mechanisms-predictors-and-management-of-surgical%C3%A2-and-transcatheter-valve-degeneration
#8
REVIEW
Tania Rodriguez-Gabella, Pierre Voisine, Rishi Puri, Philippe Pibarot, Josep Rodés-Cabau
In recent times, there has been a considerable increase in the use of aortic bioprostheses (vs. mechanical prostheses) for treating aortic valve disease, and this tendency is likely to continue in the near future. However, the occurrence of structural valve degeneration, limiting valve durability, remains an important drawback of surgical and transcatheter bioprostheses. In this paper, we provide an overview of bioprosthetic valve durability, focusing on the definition, incidence, mechanisms, predictive factors, and management of structural degeneration of aortic bioprostheses...
August 22, 2017: Journal of the American College of Cardiology
https://www.readbyqxmd.com/read/28817669/the-association-between-renal-recovery-after-acute-kidney-injury-and-long-term-mortality-after-transcatheter-aortic-valve-replacement
#9
Charat Thongprayoon, Wisit Cheungpasitporn, Narat Srivali, Wonngarm Kittanamongkolchai, Ankit Sakhuja, Kevin L Greason, Kianoush B Kashani
BACKGROUND: This study aimed to examine the association between renal recovery status at hospital discharge after acute kidney injury (AKI) and long-term mortality following transcatheter aortic valve replacement (TAVR). METHODS: We screened all adult patients who survived to hospital discharge after TAVR for aortic stenosis at a quaternary referral medical center from January 1, 2008, through June 30, 2014. An AKI was defined as an increase in serum creatinine level of 0...
2017: PloS One
https://www.readbyqxmd.com/read/28812435/transcatheter-aortic-valve-implantation-compared-with-surgical-aortic-valve-replacement-in-patients-with-anaemia
#10
Paola D'Errigo, Fausto Biancari, Stefano Rosato, Corrado Tamburino, Marco Ranucci, Gennaro Santoro, Marco Barbanti, Martina Ventura, Danilo Fusco, Fulvia Seccareccia
OBJECTIVES: We compared the outcome of anaemic patients undergoing transcatheter (TAVI) and surgical aortic valve replacement (SAVR) for severe aortic valve stenosis. METHODS: Anaemic patients (haemoglobin <13.0 g/dL in men and <12.0 g/dL in women) undergoing TAVI and SAVR from the OBSERVANT study were the subjects of this analysis. RESULTS: Preoperative anaemia was an independent predictor of 3-year mortality after either TAVI (HR 1...
August 16, 2017: Acta Cardiologica
https://www.readbyqxmd.com/read/28808772/longitudinal-strain-assessed-by-cardiac-magnetic-resonance-correlates-to-hemodynamic-findings-in-patients-with-severe-aortic-stenosis-and-predicts-positive-remodeling-after-transcatheter-aortic-valve-replacement
#11
Dominik Buckert, Maciej Cieslik, Raid Tibi, Michael Radermacher, Volker Rasche, Peter Bernhardt, Vinzenz Hombach, Wolfgang Rottbauer, Jochen Wöhrle
AIMS: To assess left-ventricular strain parameters before and after transcatheter aortic valve replacement (TAVR) by feature tracking cardiac magnetic resonance imaging (FT CMR) and to correlate the findings to hemodynamic state and left-ventricular remodeling. METHODS AND RESULTS: Patients with symptomatic AS underwent FT CMR before and after TAVR. Patients were carefully evaluated by a comprehensive work-up including CMR, echocardiography and left and right heart catheterization...
August 14, 2017: Clinical Research in Cardiology: Official Journal of the German Cardiac Society
https://www.readbyqxmd.com/read/28807801/impact-of-diabetes-mellitus-on-clinical-outcomes-and-quality-of-life-after-transcatheter-aortic-valve-implantation-for-severe-aortic-valve-stenosis
#12
Tomasz Tokarek, Artur Dziewierz, Agata Wiktorowicz, Maciej Bagienski, Lukasz Rzeszutko, Danuta Sorysz, Pawel Kleczynski, Dariusz Dudek
BACKGROUND: Diabetes mellitus (DM) has been considered as a marker of poor prognosis after cardiac surgery. We sought to investigate the impact of DM on clinical outcomes and quality of life (QoL) after transcatheter aortic valve implantation (TAVI). METHODS: A total of 148 consecutive patients with symptomatic, severe aortic stenosis who underwent TAVI were included. Baseline characteristics, procedural and long-term clinical outcomes as well as the results of frailty and QoL assessment with EQ-5D-3L questionnaire were compared between patients with and without DM...
August 11, 2017: Hellenic Journal of Cardiology: HJC, Hellēnikē Kardiologikē Epitheōrēsē
https://www.readbyqxmd.com/read/28806252/quality-and-safety-in-health-care-part-xxx-transcatheter-aortic-valve-therapy
#13
Jay A Harolds
Initially, the transcatheter aortic valve replacement procedure was approved only for patients with aortic stenosis that was both severe and symptomatic who either also had too high a risk of aortic valve replacement surgery to have the surgery or who had a high risk for the surgery. Between the years 2012 and 2015, the death rate at 30 days declined from an initial rate of 7.5% to 4.6%. There has also been more use of the transfemoral approach over the years. In 2016, the transcatheter aortic valve replacement was approved for patients with aortic stenosis at intermediate risk of surgery...
August 12, 2017: Clinical Nuclear Medicine
https://www.readbyqxmd.com/read/28806240/quality-and-safety-in-health-care-part-xxxi-selected-risk-factors-for-transcatheter-aortic-valve-replacement
#14
Jay A Harolds
The Transcatheter Valve Therapy Registry has been very helpful in providing data to better understand patient risk factors for transcatheter aortic valve replacement (TAVR). The outcome of TAVR depends on many patient indicators, some of which are given in this article, including the age, dependence on oxygen, classification of pulmonary disease, gender, and the speed of walking. Patient characteristics also help determine which approach will be used to place the device. There are models for the outcome of the TAVR procedure now and more being developed...
August 12, 2017: Clinical Nuclear Medicine
https://www.readbyqxmd.com/read/28805039/unnatural-milieu-thrombus-after-transcatheter-mitral-valve-replacement
#15
EDITORIAL
Jaffar M Khan, Robert J Lederman
What the article teaches Transcatheter heart valve thrombosis in the mitral position causes increased valve gradients, valve dysfunction, and symptoms, and may be associated with lack of therapeutic anticoagulation. How it will impact practice Anticoagulation with a vitamin K antagonist should be considered in all patients undergoing transcatheter mitral valve replacement. What new research/study would help answer the question posed Efficacy, optimal duration, and safety of anticoagulation therapy, balancing reduced thrombosis against increased bleeding risk, needs to be assessed in larger cohort studies and prospective trials...
August 1, 2017: Catheterization and Cardiovascular Interventions
https://www.readbyqxmd.com/read/28803656/outcomes-of-transcatheter-versus-surgical-aortic-valve-implantation-for-aortic-stenosis-in-patients-with-hepatic-cirrhosis
#16
Fahad Alqahtani, Sami Aljohani, Anas Ghabra, Fares Alahdab, Akram Kawsara, David R Holmes, Mohamad Alkhouli
Current risk prediction tools for transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR) do not include variables associated with clinically significant hepatic disease. Accordingly, outcome data of TAVI or SAVR in patients with liver cirrhosis are limited. We sought to assess contemporary trends and outcomes of TAVI and SAVR in patients with liver cirrhosis using a national database. The Nationwide Inpatient Sample was used to identify patients with liver cirrhosis who underwent TAVI or SAVR between 2003 and 2014...
July 14, 2017: American Journal of Cardiology
https://www.readbyqxmd.com/read/28801838/erratum-to-imaging-for-planning-of-transcatheter-aortic-valve-implantation
#17
H A Hildebrandt, A A Mahabadi, M Totzeck, R A Janosi, A Y Lind, T Schlosser, M Forsting, T Rassaf, P Kahlert
No abstract text is available yet for this article.
August 11, 2017: Herz
https://www.readbyqxmd.com/read/28800985/assessment-of-paravalvular-leak-after-transcatheter-aortic-valve-replacement-transesophageal-echocardiography-compared-with-transthoracic-echocardiography
#18
Emily G Teeter, Claire Dakik, Mary Cooter, Zainab Samad, Kamrouz Ghadimi, J Kevin Harrison, Jeffery Gaca, Mark Stafford-Smith, Brandi A Bottiger
OBJECTIVES: Determine whether moderate or greater paravalvular leak (PVL) after transcatheter aortic valve replacement quantified using intraoperative transesophageal echocardiography (TEE) is associated with mortality and investigate the correlation between PVL grading using intraoperative TEE and postoperative transthoracic echocardiography (TTE). DESIGN: Retrospective, observational study. SETTING: Single academic institution. PARTICIPANTS: The study comprised adult patients undergoing elective transcatheter aortic valve replacement between April 2011 and February 2014...
August 2017: Journal of Cardiothoracic and Vascular Anesthesia
https://www.readbyqxmd.com/read/28799521/transcatheter-mitral-valve-replacement-long-term-outcomes-of-first-in-man-experience-with-an-apically-tethered-device-a-case-series-from-a-single-centre
#19
Alison Duncan, Anan Daqa, James Yeh, Simon Davies, Anselm Uebing, Cesare Quarto, Neil Moat
AIMS: Transcatheter mitral valve replacement (TMVR) is a novel technique for treating mitral regurgitation. We report 18-month/2-year outcomes of the 5 first-in-man patients undergoing chronic TMVR with the Tendyne device. METHODS AND RESULTS: Five patients (STS score 14%-23%) underwent TMVR using a Tendyne system under compassionate use at a single centre. 1 patient (who was noncompliant with anti-coagulation) died 9 months after TMVR following a cerebrovascular accident...
August 13, 2017: EuroIntervention
https://www.readbyqxmd.com/read/28799113/angles-between-the-aortic-root-and-the-left-ventricle-assessed-by-mdct-are-associated-with-the-risk-of-aortic-regurgitation-after-transcatheter-aortic-valve-replacement
#20
Vincent Roule, Alexandre Placente, Rémi Sabatier, Mathieu Bignon, Vladimir Saplacan, Calin Ivascau, Paul Milliez, Farzin Beygui
OBJECTIVES: To evaluate the impact of the angles quantified by multidetector computed tomography (MDCT) between the ascending aorta's long axis and, the left ventricular inflow long axis (LVLA), or the left ventricule outflow tract long axis, and the occurrence of post-transcatheter aortic valve replacement (TAVR) aortic regurgitation (AR). METHODS: We prospectively included 136 consecutive patients who underwent a transfemoral TAVR with a preoperative MDCT. The groups were defined according to AR <2 or ≥2 assessed by echocardiography at 1 month...
August 10, 2017: Heart and Vessels
keyword
keyword
27153
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"