Read by QxMD icon Read

Arterial catheter

Matthias Hansen
Advanced hemodynamic monitoring is necessary for adequate management of high-risk patients or patients with derangement of circulation. Studies demonstrate a benefit of early goal directed therapy in unstable cardiopulmonary situations. In these days we have different possibilities of minimally invasive or invasive hemodynamic monitoring. Minimally invasive measurements like pulse conture analysis or pulse wave analysis being less accurate under some circumstances, however only an artery catheter is needed for cardiac output monitoring...
October 2016: Anästhesiologie, Intensivmedizin, Notfallmedizin, Schmerztherapie: AINS
Anuj Mahajan, Sherwin Abdoli, Sukgu Han, Christian Ochoa
No abstract text is available yet for this article.
August 2016: Journal of Vascular Surgery
Jason Q Alexander, Claire Ostertag-Hill, Peter Alden, Jesse Manunga, Jess Titus, Elliot Stephenson, Kasia Hryniewicz-Czeneszew, Timothy Sullivan
No abstract text is available yet for this article.
August 2016: Journal of Vascular Surgery
Atsushi Nakagomi, Sho Okada, Toshihiro Shoji, Yoshio Kobayashi
Our aim was to assess the discrepancy in the blood pressure amplification (BPA) value defined as the aortic-to-brachial increase in systolic BP (SBP) between invasive and noninvasive brachial cuff-based methods. In 45 patients undergoing cardiac catheterization, BP in the brachial artery and ascending aorta were measured with an invasive catheter and a brachial cuff-based oscillometric device. To calculate aortic SBP, brachial waveforms were calibrated by the brachial systolic and diastolic BP (DBP) (C1 calibration) or by the brachial mean BP and DBP (C2 calibration)...
October 20, 2016: Hypertension Research: Official Journal of the Japanese Society of Hypertension
Shigemitsu Shirai, Keisuke Hirano, Norihiro Kobayashi
It is difficult to treat a thrombotic embolism in the common femoral artery or popliteal artery (POP A), i.e., the non-stenting zone. We report a new technique for the treatment of thrombotic embolism in the non-stenting zone using a self-expandable nitinol stent. Case 1 had an external iliac artery (EIA) occlusion that occurred over several months. A self-expandable nitinol stent was placed in the right EIA lesion via a retrograde approach using a distal 9-Fr balloon protection guide catheter in the right femoral artery...
October 19, 2016: Catheterization and Cardiovascular Interventions
Takayuki Warisawa, Toru Naganuma, Sunao Nakamura
We report a case of percutaneous coronary intervention in a bifurcation lesion involving left circumflex (LCx) artery and 2 major posterolateral (PL) arteries. The target LCx had diffuse long and severely calcified lesion with the acute takeoff angle from the left main. Despite adequate lesion preparation with rotational atherectomy and balloon angioplasty, the stent was not deliverable, even with deep intubation of 7Fr-guiding catheter. Conventional use of guiding extension catheter (GEC) would have required removal of a wire from at least one PL because of the device interference in the GEC...
October 18, 2016: Cardiovascular Intervention and Therapeutics
Matthias Peter Hilty, Andrea Müller, Daniela Flück, Christoph Siebenmann, Peter Rasmussen, Stefanie Keiser, Katja Auinger, Carsten Lundby, Marco Maggiorini
: Matthias Peter Hilty, Andrea Mueller, Daniela Flück, Christoph Siebenmann, Peter Rasmussen, Stefanie Keiser, Katja Auinger, Carsten Lundby, and Marco Maggiorini. Effect of increased blood flow on the pulmonary circulation before and during high altitude acclimatization. High Alt Med Biol. 00:000-000, 2016.-Introduction and Methods: Acute exposure to high altitude increases pulmonary artery pressure (Ppa) and pulmonary vascular resistance (PVR). The evolution of Ppa and PVR with continuous hypoxic exposure remains, however, elusive...
October 18, 2016: High Altitude Medicine & Biology
Thomas Weber
Validation of a medical device measuring a biomarker is a complex process, involving technical aspects (What is actually measured by the device, and how is this done ? Is the measurement reproducible ? Is there a gold standard for measurement of the particular biomarker ? If yes, how accurate and how precise are the measurements by the device, compared to the gold standard ?) and clinical aspects (Do the measurements predict outcome ? If yes, is there added value, when standard clinical parameters are considered ? Is there a treatment strategy, based on the mesurements of the novel device ? Is this strategy cost-effective ?)...
September 2016: Journal of Hypertension
Markus Schlaich
Accumulating evidence from mainly uncontrolled and unblinded clinical studies with various types of ablation catheters have shown that renal denervation (RDN) can be applied safely and is effective in lowering blood pressure (BP) in most patients with treatment resistant hypertension. Sustained BP lowering has been documented up to 3 years at this stage. Furthermore, RDN has been associated with regression of target organ damage, such as left ventricular hypertrophy, arterial stiffness and others. Several studies indicate potential benefit in other common clinical conditions associated with increased sympathetic tone including chronic kidney disease and heart failure...
September 2016: Journal of Hypertension
Kate Denton, Karen Moritz, Lindsey Booth, Clive May, Geoff Head, Markus Schlaich, Reetu Singh
OBJECTIVE: Renal sympathetic nerves contribute significantly to the control of kidney function and blood pressure. A critical question is whether catheter-based renal denervation (cDNX) has adverse consequences, in situations of clinical challenge, such as hemorrhage. The aim was to examine the effects of cDNX on basal mean arterial pressure (MAP) and glomerular filtration rate (GFR) and in response to hemorrhage in hypertensive sheep with chronic kidney disease (CKD). DESIGN AND METHOD: Hypertension and CKD was induced in sheep by performing fetal unilateral nephrectomy (CKD; N = 14)...
September 2016: Journal of Hypertension
Stanislav Pekarskiy, Andrei Baev, Viktor Mordovin, Galina Semke, Tatiana Ripp, Alla Falkovskaya, Ekaterina Sitkova, Valeria Lichikaki, Irina Zubanova, Maria Kuzmichkina, Sergei Popov
OBJECTIVE: A failure of endovascular renal denervation (RDN) as a series of point treatments equally distributed within main trunk of renal artery (Symplicity and other methods) was easily predictable. It may only be effective if all renal nerves closely follow the course of renal artery (RA) from aorta to the kidney. However, surgical studies demonstrated that proximally most renal nerves go at a distance from RA and join mainly its distal part. To evaluate whether denervation treatment in distal part of RA is more effective than conventional RDN...
September 2016: Journal of Hypertension
Chikao Miyazaki, Mao Takahashi, Kazuhiro Shimizu, Tatsuo Chiba, Takenori Morisita, Tomoyuki Yamamoto, Nobuo Sugo, Akira Takahara, Kohji Shirai
OBJECTIVE: Cardio ankle vascular index (CAVI) is reflecting stiffness of the arterial tree from the origin of aorta to the ankles. We observed elevated CAVI in patients who suffered from apoplexy attack. To clarify the role and the mechanism by which arterial stiffness elevated just after apoplexy attack, the effect of enhanced intracranial pressure (ICP) by injecting saline into the cisterna magna of the rabbit on blood pressure, CAVI and cervical blood flow, were studied. Furthermore the role of sympathetic nerve was studied...
September 2016: Journal of Hypertension
Joon Kyungjoon Lim, Benjie Barzel, Sandra Burke
OBJECTIVE: Hypertension affects one third of the population around the world and is a major contributor to cardiovascular disease. There is strong evidence that the main cause of hypertension is increases sympathetic nerve activity to specific organs. Plasma leptin levels correlate with blood pressure (BP) and renal sympathetic nerve activity (RSNA). The central effects of leptin are mediated primarily through the arcuate (ARC) nucleus of the hypothalamus. Both neuropeptide-Y (NPY) and alpha-melanocyte stimulating hormone (α-MSH) containing neurons ascend from the ARC and terminate in ventromedial hypothalamus (VMH) which are the key centres of energy homeostasis, hemodynamics and sympathetic tone to renal vasculature...
September 2016: Journal of Hypertension
Jorge Aramburu, Raúl Antón, Alejandro Rivas, Juan Carlos Ramos, Bruno Sangro, José Ignacio Bilbao
Radioembolization, which consist of the implantation of radioactive microspheres via intra-arterially placed microcatheter, is a safe and effective treatment for liver cancer. Nevertheless, radioembolization-related complications and side effects may arise, which are an active area of ongoing research. The catheter design has been claimed as an option in reducing these complications. In this paper, the influence of catheter type and location are investigated. The study was undertaken by numerically simulating the particle-hemodynamics in a patient-specific hepatic artery during liver radioembolization...
October 7, 2016: Journal of Biomechanics
Kriton-Ioannis Roukas, Konstantinos Lampropoulos, Anastasios Salachas
No abstract text is available yet for this article.
September 2016: Indian Heart Journal
Masahiro Takita, Mina Iwanishi, Tomohiro Minami, Masashi Kono, Hirokazo Chishina, Tadaaki Arizumi, Norihisa Yada, Satoru Hagiwara, Yasunori Minami, Hiroshi Ida, Kazuomi Ueshima, Nishida Naoshi, Masatoshi Kudo
OBJECTIVE: The objective of treatment for polycystic liver disease is to reduce the liver volume and reduce or resolve compression symptoms such as abdominal fullness and abdominal pain due to hepatomegaly. Liver cysts are treated internally by puncture and aspiration of the cyst contents or hepatic artery embolization and surgically by cyst fenestration or hepatectomy, but no clear consensus has been reached concerning their selection. We introduced monoethanolamine oleate (EO) sclerotherapy therapy for liver cysts in 1999 and reported its effectiveness...
2016: Digestive Diseases
Lei Zhao, Long-Bo Li, Zhi-Hui Wang, Yong-Feng Shi, Jun-Duo Wu, Ji-Chang Zhang, Bin Liu
BACKGROUND: The CrossBoss coronary chronic total occlusion (CTO) crossing catheter has been demonstrated to have greatly improved the success rate of crossing CTO lesions, but there are no published data on its application for in-stent CTO lesions. METHODS: In the current study, we retrospectively reviewed the clinical data of 8 patients with in-stent CTO lesions that were managed with the CrossBoss catheter and herein we report the efficacy and safety of the CrossBoss crossing and re-entry system for this clinically challenging condition...
October 2016: Medicine (Baltimore)
David A Berlin, Harrison Peprah-Mensah, Seth Manoach, Paul M Heerdt
OBJECTIVE: The study tests the hypothesis that noninvasive cardiac output monitoring based upon bioreactance (Cheetah Medical, Portland, OR) has acceptable agreement with intermittent bolus thermodilution over a wide range of cardiac output in an adult porcine model of hemorrhagic shock and resuscitation. DESIGN: Prospective laboratory animal investigation. SETTING: Preclinical university laboratory. SUBJECTS: Eight ~ 50 kg Yorkshire swine with a femoral artery catheter for blood pressure measurement and a pulmonary artery catheter for bolus thermodilution...
October 3, 2016: Critical Care Medicine
Rodrigo Rios, Susan R Foerster, Todd M Gudausky
The Melody® transcatheter pulmonary valve system was developed for placement within right ventricle-to-pulmonary artery conduits in patients with CHD for treatment of stenosis or regurgitation, providing an alternative to open-heart surgery. Abnormal systemic venous connections altering the catheter course to the right ventricle-to-pulmonary artery conduit may present a challenge to Melody® valve implantation. We present two such cases, in which the Melody® valve was successfully implanted in teenage patients with congenitally corrected transposition of the great arteries after Senning atrial switch operation...
October 17, 2016: Cardiology in the Young
Masaaki Murakami, Genichi Sakaguchi, Noriko Mori
OBJECTIVE: In patients with a high risk of fistula immaturity, we created arteriovenous fistulas (AVFs) combined with brachial artery superficialization. With this procedure, the superficialized arteries are used as drawing routes and the AVFs as returning routes. This is a technical report about AVFs combined with brachial artery superficialization. METHODS: Twenty-four consecutive patients with a high risk of fistula immaturity who underwent AVFs with brachial artery superficialization were included in this single-center retrospective study...
October 12, 2016: Journal of Vascular Surgery
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"