keyword
MENU ▼
Read by QxMD icon Read
search

IOL power calculations

keyword
https://www.readbyqxmd.com/read/28050320/changes-in-anterior-chamber-depth-after-phacoemulsification-in-pseudoexfoliative-eyes-and-their-effect-on-accuracy-of-intraocular-lens-power-calculation
#1
Sirel Gür Güngör, Ahmet Akman, Leyla Asena, Mustafa Aksoy, Almila Sarıgül Sezenöz
OBJECTIVES: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study...
December 2016: Turkish Journal of Ophthalmology
https://www.readbyqxmd.com/read/28040496/analysis-of-cataract-surgery-induced-astigmatism-two-polar-methods-comparison
#2
Veronica García-López, Claudia García-López, Victoria de Juan, Raul Martin
PURPOSE: Surgically induced astigmatism (SIA) caused by the incision after cataract surgery may be calculated to improve IOL toric power calculation and achieve better visual outcome. SIA could be determined as the difference between preoperative and postoperative keratometry expressed in polar values using different equations. The objective of this study is to compare the SIA calculated with two different polar value analysis methods [Method #1: KP (90)/KP (135) developed to be used with incisions placed at 90° and Method #2: AKP/AKP (+45) developed to be used independently of the incision location]...
December 28, 2016: Journal of Optometry
https://www.readbyqxmd.com/read/28002107/astigmatism-correction-with-toric-intraocular-lenses-in-descemet-membrane-endothelial-keratoplasty-triple-procedures
#3
Hideaki Yokogawa, P James Sanchez, Zachary M Mayko, Michael D Straiko, Mark A Terry
PURPOSE: To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. METHODS: Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging...
December 20, 2016: Cornea
https://www.readbyqxmd.com/read/27957314/the-relationship-between-anterior-chamber-depth-axial-length-and-intraocular-lens-power-among-candidates-for-cataract-surgery
#4
Mohammad Reza Sedaghat, Ali Azimi, Peyman Arasteh, Naghmeh Tehranian, Shahram Bamdad
INTRODUCTION: Basic anatomical parameters in ophthalmology are variable in different countries according to ethnic groups, genetics and some environmental factors. The aim of this study was to determine the relationship between axial length (AL), anterior chamber depth (ACD) and intraocular lens power (IOL) in a referral center from eastern Iran among patients who had cataract surgery, in comparison to studies from other regions of the world. METHODS: In a cross-sectional retrospective study from 2011 to 2013, the records of 698 cataract patients referring to Khatam Al Anbia general hospital in Mashhad, Iran were evaluated...
October 2016: Electronic Physician
https://www.readbyqxmd.com/read/27956289/pterygium-size-and-effect-on-intraocular-lens-power-calculation
#5
Mustafa Koc, Mehmet Murat Uzel, Emre Aydemir, Fuat Yavrum, Pinar Kosekahya, Pelin Yılmazbaş
PURPOSE: To evaluate the effects of pterygium on biometry measurements and the relationship between these effects and pterygium size. SETTING: Ulucanlar Eye Hospital, Ankara, Turkey. DESIGN: Prospective comparative study. METHODS: Patients who had unilateral primary pterygium excision were included in the study group. Anterior segment photographed images were taken of eyes with pterygia to calculate the pterygium length and area using the ImageJ program...
November 2016: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/27956286/residual-astigmatism-after-toric-intraocular-lens-implantation-analysis-of-data-from-an-online-toric-intraocular-lens-back-calculator
#6
Brent A Kramer, John P Berdahl, David R Hardten, Richard Potvin
PURPOSE: To evaluate some possible causes for residual astigmatism after toric intraocular lens (IOL) implantation based on an analysis of data from an online toric IOL back-calculator. DESIGN: Retrospective data review. METHODS: An online toric back-calculator was designed to allow users to input preoperative toric planning information along with postoperative IOL orientation and refractive results. These were then used to determine the optimum orientation of the IOL to reduce refractive astigmatism...
November 2016: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/27956285/influence-on-intraocular-lens-power-calculation-of-corneal-radii-measurement-using-an-image-guided-system
#7
Bettina C Thomas, Andreas Mueller, Gerd U Auffarth, Mike P Holzer
PURPOSE: To analyze the influence on intraocular lens (IOL) power calculation of corneal radii measured by the Verion Image-Guided System in comparison with those measured by partial coherence interferometry (PCI) (IOLMaster) and optical low-coherence reflectometry (OLCR) (Lenstar) systems. SETTING: International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany. DESIGN: Prospective case series...
November 2016: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/27846894/corneal-power-evaluation-after-myopic-corneal-refractive-surgery-using-artificial-neural-networks
#8
Robert Koprowski, Michele Lanza, Carlo Irregolare
BACKGROUND: Efficacy and high availability of surgery techniques for refractive defect correction increase the number of patients who undergo to this type of surgery. Regardless of that, with increasing age, more and more patients must undergo cataract surgery. Accurate evaluation of corneal power is an extremely important element affecting the precision of intraocular lens (IOL) power calculation and errors in this procedure could affect quality of life of patients and satisfaction with the service provided...
November 15, 2016: Biomedical Engineering Online
https://www.readbyqxmd.com/read/27843285/clinical-outcomes-with-toric-intraocular-lenses-planned-using-an-optical-low-coherence-reflectometry-ocular-biometer-with-a-new-toric-calculator
#9
Kjell G Gundersen, Richard Potvin
PURPOSE: To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs) using preoperative keratometry from an optical low coherence reflectometry (OLCR) ocular biometer (Lenstar(®) LS900) and the built-in Barrett toric calculator. PATIENTS AND METHODS: A prospective observational study recruited one or both eyes of subjects who underwent uncomplicated cataract surgery with toric IOL implantation using OLCR biometery data and the Barrett toric IOL calculator for toric IOL planning...
2016: Clinical Ophthalmology
https://www.readbyqxmd.com/read/27834962/agreement-and-clinical-comparison-between-a-new-swept-source-optical-coherence-tomography-based-optical-biometer-and-an-optical-low-coherence-reflectometry-biometer
#10
P Arriola-Villalobos, J Almendral-Gómez, N Garzón, J Ruiz-Medrano, C Fernández-Pérez, J M Martínez-de-la-Casa, D Díaz-Valle
PurposeTo compare measurements taken using a swept-source optical coherence tomography-based optical biometer (IOLmaster 700) and an optical low-coherence reflectometry biometer (Lenstar 900), and to determine the clinical impacts of differences in their measurements on intraocular lens (IOL) power predictions.MethodsEighty eyes of 80 patients scheduled to undergo cataract surgery were examined with both biometers. The measurements made using each device were axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW), and pupil diameter (PD)...
November 11, 2016: Eye
https://www.readbyqxmd.com/read/27833928/comparison-of-a-new-optical-biometer-and-a-standard-biometer-in-cataract-patients
#11
Pipat Kongsap
BACKGROUND: Cataract surgery is the most common surgical procedure in ophthalmology. Biometry data and accurate intraocular lens (IOL) calculations are very important in achieving the desired refractive outcomes. The aim of this study was to compare measurements using a new optical low coherence reflectometry (OLCR) biometer (OA-2000) and the gold standard partial coherence interferometry (PCI) optical biometer (IOLMaster 500). METHODS: Ocular biometry of cataract patients were measured by the OA-2000 and IOLMaster 500 to compare keratometry (K), axial length (AL), anterior chamber depth (ACD), white-to-white (WTW) diameter, and IOL power using the SRK/T formula...
2016: Eye and Vision (London, England)
https://www.readbyqxmd.com/read/27793471/effect-of-pharmacological-pupil-dilation-on-measurements-and-iol-power-calculation-made-using-the-new-swept-source-optical-coherence-tomography-based-optical-biometer
#12
P Arriola-Villalobos, J Almendral-Gómez, N Garzón, J Ruiz-Medrano, C Fernández-Pérez, J M Martínez-de-la-Casa, D Díaz-Valle
PURPOSE: To determine whether pupil dilation affects biometric measurements and intraocular lens (IOL) power calculation made using the new swept-source optical coherence tomography-based optical biometer (IOLMaster 700(©); Carl Zeiss Meditec, Jena, Germany). PROCEDURES: Eighty-one eyes of 81 patients evaluated for cataract surgery were prospectively examined using the IOLMaster 700(©) before and after pupil dilation with tropicamide 1%. The measurements made were: axial length (AL), central corneal thickness (CCT), aqueous chamber depth (ACD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW) and pupil diameter (PD)...
December 2016: Journal Français D'ophtalmologie
https://www.readbyqxmd.com/read/27785598/pseudo-accommodation-in-non-amblyopic-children-after-bilateral-cataract-surgery-and-implantation-with-a-monofocal-intraocular-lens-prevalence-and-possible-mechanisms
#13
Charlotte Dénier, Pascal Dureau, Catherine Edelson, Amandine Barjol, Georges Caputo
BACKGROUND: Some pseudophakic patients implanted with a monofocal intraocular lens (IOL) have good near visual acuity (VA) with their distance correction. The objective was to evaluate the prevalence of pseudo-accommodation in children after bilateral cataract surgery, without amblyopia, and to define its mechanisms. METHODS: Observational study that took place in a pediatric ophthalmology department, Paris, France. A total of 68 eyes were included, 40 from 23 children and 28 from 14 adults, with a corrected distance VA above 20/25 and a normal near VA (20/25) with +3 addition...
October 26, 2016: Graefe's Archive for Clinical and Experimental Ophthalmology
https://www.readbyqxmd.com/read/27769585/prediction-of-postoperative-intraocular-lens-position-with-angle-to-angle-depth-using-anterior-segment-optical-coherence-tomography
#14
So Goto, Naoyuki Maeda, Shizuka Koh, Kazuhiko Ohnuma, Kenichi Hayashi, Ikko Iehisa, Toru Noda, Kohji Nishida
PURPOSE: To evaluate the accuracy of a new formula for predicting postoperative anterior chamber depth (ACD) with preoperative angle-to-angle (ATA) depth using anterior segment (AS) optical coherence tomography (OCT) and to compare it with established methods. DESIGN: Retrospective consecutive case series. PARTICIPANTS: Three hundred four eyes (276 patients) implanted with acrylic intraocular lenses (IOLs) were divided randomly into a training set (152 eyes) and a validation set (152 eyes)...
December 2016: Ophthalmology
https://www.readbyqxmd.com/read/27703323/toric-intraocular-lens-orientation-and-residual-refractive-astigmatism-an-analysis
#15
Rick Potvin, Brent A Kramer, David R Hardten, John P Berdahl
PURPOSE: To analyze intraocular lens (IOL) orientation data from an online toric back-calculator (astigmatismfix.com) for determining if differences were apparent by lens type. METHODS: A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis. RESULTS: Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69%) involved lenses oriented 5° or more from their intended position...
2016: Clinical Ophthalmology
https://www.readbyqxmd.com/read/27702623/changes-in-ocular-parameters-and-intraocular-lens-powers-in-aging-cycloplegic-eyes
#16
Pelin Özyol, Erhan Özyol, Ercan Baldemir
PURPOSE: Age-related changes in lens elasticity and ciliary muscle contractility can affect how ocular parameters respond to cycloplegia, and therefore intraocular lens (IOL) power measurements calculated by formulas using anterior chamber depth (ACD), lens thickness (LT), or white-to-white (WtW) for effective lens position prediction can vary. In response, using swept-source optical biometry in prepresbyopic and presbyopic eyes, we investigated changes in ocular parameters and IOL power calculations attributable to cycloplegia...
January 2017: American Journal of Ophthalmology
https://www.readbyqxmd.com/read/27672591/effects-of-posterior-corneal-astigmatism-on-the-accuracy-of-acrysof-toric-intraocular-lens-astigmatism-correction
#17
Bin Zhang, Jing-Xue Ma, Dan-Yan Liu, Cong-Rong Guo, Ying-Hua Du, Xiu-Jin Guo, Yue-Xian Cui
AIM: To evaluate the effects of posterior corneal surface measurements on the accuracy of total estimated corneal astigmatism. METHODS: Fifty-seven patients with toric intraocular lens (IOL) implantation and posterior corneal astigmatism exceeding 0.5 diopter were enrolled in this retrospective study. The keratometric astigmatism (KA) and total corneal astigmatism (TA) were measured using a Pentacam rotating Scheimpflug camera to assess the outcomes of AcrySof IOL implantation...
2016: International Journal of Ophthalmology
https://www.readbyqxmd.com/read/27642519/outcomes-of-sutureless-iris-claw-lens-implantation
#18
Tomasz Choragiewicz, Robert Rejdak, Andrzej Grzybowski, Katarzyna Nowomiejska, Joanna Moneta-Wielgoś, Małgorzata Ozimek, Anselm G M Jünemann
Purpose. To evaluate the indications, refraction, and visual and safety outcomes of iris-claw intraocular lens implanted retropupillary with sutureless technique during primary or secondary operation. Methods. Retrospective study of case series. The Haigis formula was used to calculate intraocular lens power. In all cases the wound was closed without suturing. Results. The study comprised 47 eyes. The mean follow-up time was 15.9 months (SD 12.2). The mean preoperative CDVA was 0.25 (SD 0.21). The final mean CDVA was 0...
2016: Journal of Ophthalmology
https://www.readbyqxmd.com/read/27586670/scheimpflug-camera-combined-with-placido-disk-corneal-topography-and-optical-biometry-for-intraocular-lens-power-calculation
#19
Ahmet Kirgiz, Kurşat Atalay, Havva Kaldirim, Kubra Serefoglu Cabuk, Mehmet Orcun Akdemir, Muhittin Taskapili
The purpose of this study was to compare the keratometry (K) values obtained by the Scheimpflug camera combined with placido-disk corneal topography (Sirius) and optical biometry (Lenstar) for intraocular lens (IOL) power calculation before the cataract surgery, and to evaluate the accuracy of postoperative refraction. 50 eyes of 40 patients were scheduled to have phacoemulsification with the implantation of a posterior chamber intraocular lens. The IOL power was calculated using the SRK/T formula with Lenstar K and K readings from Sirius...
September 1, 2016: International Ophthalmology
https://www.readbyqxmd.com/read/27562431/influence-of-patient-age-on-intraocular-lens-power-prediction-error
#20
Ken Hayashi, Soichiro Ogawa, Motoaki Yoshida, Koichi Yoshimura
PURPOSE: To examine whether intraocular lens (IOL) power prediction error (PE) after cataract surgery differs according to patient age. DESIGN: Prospective cohort study. METHODS: We consecutively enrolled 75 eyes of 75 patients 59 years of age or younger, and 150 eyes of 150 patients in each of 3 age groups (60-69, 70-79, and 80-89 years), for whom phacoemulsification and implantation of a single-piece acrylic IOL was planned. The IOL power was calculated using the optimized SRK/T formula...
October 2016: American Journal of Ophthalmology
keyword
keyword
20168
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"