keyword
https://read.qxmd.com/read/38606957/monoaxial-screws-versus-polyaxial-screws-osteosynthesis-for-unstable-atlas-fractures-a-retrospective-comparative-study-with-a-minimum-follow-up-of-3-years
#21
JOURNAL ARTICLE
He-Gang Niu, Cheng-Kun Zhao, Kun Yang, Hui Tao, Chang Liu, Jing-Jing Zhang, Cai-Liang Shen, Yin-Shun Zhang
STUDY DESIGN: Retrospective cohort study. OBJECTIVE: The study aimed to compare the radiological parameters, clinical outcomes, and long-term effects of the posterior osteosynthesis with polyaxial screw-rod system and the monoaxial screw-rod system in the treatment of unstable atlas fractures. METHODS: We retrospectively analyzed the clinical data of 33 patients with posterior ORIF for unstable atlas fractures in our hospital from August 2013 to June 2020, with a minimum of 3 years of follow-up...
April 12, 2024: Global Spine Journal
https://read.qxmd.com/read/38604919/effective-strategies-in-the-management-of-anterior-mandibular-fractures-a-comprehensive-systematic-review
#22
REVIEW
Rajan Savani, Hu Weihsin, Shital Patel, Naiya Shah, Shyam Chauhan, Yashasvi Chavda
This review examines the prevailing modalities for fractures of the anterior mandible, which represent a significant proportion of the maxillofacial injuries commonly treated by oral and maxillofacial surgeons. The article traces the historical shift from conservative techniques to the dominant management strategies of open reduction and fixation. Encompassing a range of studies, the review, in accordance with PRISMA 2020 recommendations, meticulously examines various fixation methods, assessing their efficacy in achieving stability of fracture, early healing, and mobilisation...
February 27, 2024: British Journal of Oral & Maxillofacial Surgery
https://read.qxmd.com/read/38604397/improvement-of-coracoid-process-union-rates-a-comparative-study-of-conventional-open-and-arthroscopic-assisted-bristow-procedures-for-treating-anterior-shoulder-instability-in-rugby-players
#23
JOURNAL ARTICLE
Makoto Tanaka, Takehito Hirose, Hiroto Hanai, Yuki Kotani, Kosuke Kuratani, Hidekazu Nakai, Kenji Hayashida
BACKGROUND: The Bristow coracoid transfer procedure is a reliable technique for treating anterior shoulder instability in patients with large glenoid bone loss or those involved in collision sports. However, its success is marred by its inferior bone union rate of the coracoid process as compared to the Latarjet procedure. This study aimed to evaluate whether arthroscopic confirmation of the secured coracoid fixation during the Bristow procedure improves the bone union rate and clinical outcomes as compared to the open procedure...
April 9, 2024: Journal of Shoulder and Elbow Surgery
https://read.qxmd.com/read/38603511/kink-bands-promote-exceptional-fracture-resistance-in-a-nbtatihf-refractory-medium-entropy-alloy
#24
JOURNAL ARTICLE
David H Cook, Punit Kumar, Madelyn I Payne, Calvin H Belcher, Pedro Borges, Wenqing Wang, Flynn Walsh, Zehao Li, Arun Devaraj, Mingwei Zhang, Mark Asta, Andrew M Minor, Enrique J Lavernia, Diran Apelian, Robert O Ritchie
Single-phase body-centered cubic (bcc) refractory medium- or high-entropy alloys can retain compressive strength at elevated temperatures but suffer from extremely low tensile ductility and fracture toughness. We examined the strength and fracture toughness of a bcc refractory alloy, NbTaTiHf, from 77 to 1473 kelvin. This alloy's behavior differed from that of comparable systems by having fracture toughness over 253 MPa·m1/2 , which we attribute to a dynamic competition between screw and edge dislocations in controlling the plasticity at a crack tip...
April 12, 2024: Science
https://read.qxmd.com/read/38601890/outpatient-limb-lengthening-using-magnetic-intramedullary-nails-a-single-institution-s-experience
#25
JOURNAL ARTICLE
Jeremy A Dubin, Sandeep S Bains, Mallory Moore, Michael A Assayag, Phillip K McClure
INTRODUCTION: The advantages of outpatient surgery have been shown in other orthopedic subspecialities to be a means of driving down costs and reducing the average length of hospital stay. However, there is a scarcity of literature examining the utility of a specific, hospital-based facility performing such procedures for limb lengthening. Considering this, we aimed to investigate surgical factors, patient characteristics, and the incidence of outpatient postoperative complications for patients undergoing surgery and subsequent distraction osteogenesis utilizing the Precice® nail, a state-of-the-art magnetic intramedullary nail (MILN)...
July 2024: Journal of Orthopaedics
https://read.qxmd.com/read/38601240/results-of-a-novel-technique-for-increasing-%C3%A2-bone-contact-and-stability-in-mandibular-reconstruction-with-micro-vascularized-fibula-flap
#26
JOURNAL ARTICLE
Marcio Vinícius Hurczulack, Maria Isabela Guebur, Gyl Henrique Albrecht Ramos, Alfredo Benjamin Duarte da Silva, Laurindo Moacir Sassi
BACKGROUND: Reconstruction of large mandibular defects requires reestablishment of mandibular continuity with bone and soft tissue. The microvascularized fibula flap (MFF) has the advantage of providing both, with adequate length, low resorption rate, low infection risk and possibility of dental implant insertion. It can be adapted to mandibular defects in many different ways. PURPOSE: This retrospective study will present and evaluate the results of the male-female joint technique for flap positioning and fixation...
April 2024: Journal of Maxillofacial and Oral Surgery
https://read.qxmd.com/read/38601234/modified-eyelet-wiring-a-technical-note
#27
JOURNAL ARTICLE
Ramakrishna Shenoi, Simran Sangani, Jignesh Rajguru, Kshitij Bang, Nimish Situt
INTRODUCTION: The objective of establishing intra-operative occlusion by temporary inter-maxillary fixation remains constant even with evolving principles for the treatment of facial fractures. MATERIAL AND METHODS: In the novel technique, a pre-stretched 24- gauge round stainless-steel wire of six inches length is used. RESULTS: The novel technique is a modification of the conventional eyelet wiring, which can achieve both horizontal stabilization and maxillo-mandibular fixation...
April 2024: Journal of Maxillofacial and Oral Surgery
https://read.qxmd.com/read/38601232/versatility-of-titanium-mesh-in-comminuted-maxillofacial-fractures-a-retrospective-study
#28
JOURNAL ARTICLE
Syeda Sana Arman, Akshay Shetty, Nida Ahmed, Ravalika Singarapu, Bhanu Priya, Aditya Iyengar
BACKGROUND: Titanium mesh provides three-dimensional stability, it is easier and quick in placement, highly malleable and adaptable hence, proved to be worth in restoring the function and form in cases of comminuted maxillofacial fractures. MATERIALS AND METHODS: A total of 12 patients were included in this retrospective study at Department of Oral and maxillofacial surgery, Sri Rajiv Gandhi College of Dental Science and Hospital, from December 2015 to June 2020...
April 2024: Journal of Maxillofacial and Oral Surgery
https://read.qxmd.com/read/38601059/feed-factor-profile-prediction-model-for-two-component-mixed-powder-in-the-twin-screw-feeder
#29
JOURNAL ARTICLE
Yuki Kobayashi, Sanghong Kim, Takuya Nagato, Takuya Oishi, Manabu Kano
In continuous pharmaceutical manufacturing processes, it is crucial to control the powder flow rate. The feeding process is characterized by the amount of powder delivered per screw rotation, referred to as the feed factor. This study aims to develop models for predicting the feed factor profiles (FFPs) of two-component mixed powders with various formulations, while most previous studies have focused on single-component powders. It further aims to identify the suitable model type and to determine the significance of material properties in enhancing prediction accuracy by using several FFP prediction models with different input variables...
June 2024: International journal of pharmaceutics: X
https://read.qxmd.com/read/38600978/femoral-interference-screw-divergence-as-a-result-of-anteromedial-portal-insertion-and-outside-in-flipcutter-femoral-tunnel-drilling-a-cadaveric-study
#30
JOURNAL ARTICLE
Carson Gardner, Samuel Wu, Jamal Zahir, Oliver Dong, Oluwatodimu Raji, Jeremi Leasure, Patrick McGahan
AIMS AND OBJECTIVES: To investigate whether interference screw fixation through an anteromedial portal into an outside-in drilled femoral tunnel via a flip cutter results in acceptable hardware position. MATERIALS & METHODS: 10 cadaveric knees underwent ACL-reconstruction with patellar BTB autograft. Femoral tunnel drilling was performed utilizing an outside-in flip cutter drill and interference screws for femoral fixation. Lateral and anterior-posterior (AP) fluoroscopic images were taken to measure screw divergence within the femoral tunnel...
June 2024: Journal of Orthopaedics
https://read.qxmd.com/read/38600312/radiographic-outcomes-and-non-union-factor-analysis-in-fragmentary-segmental-femoral-shaft-fractures-ao-ota-32c3-treated-with-reamed-antegrade-nailing
#31
JOURNAL ARTICLE
Won-Tae Cho, Jae Hoon Jang, Seung Ryeol Park, Hoon-Sang Sohn
This study retrospectively assessed radiographic outcomes and risk factors associated with non-union in femoral shaft fragmentary segmental fractures (AO/OTA 32C3) treated with reamed antegrade intra-medullary nailing. Radiological outcomes, including union and alignment, were evaluated. The risk factors for non-union were investigated, including demographics and treatment-related characteristics, such as the number of interlocking screws, segmentation length, main third fragment length, distance of the main third fragment, width ratio and exposed nail length in one cortex from immediate post-operative radiographs...
April 10, 2024: Scientific Reports
https://read.qxmd.com/read/38600003/one-time-definitive-attachment-connection-versus-healing-abutment-placement-for-an-implant-retained-mandibular-overdenture-peri-implant-metabolic-activity
#32
JOURNAL ARTICLE
Abdallah Mohammed Ibrahim, Mohamed Elgamal, Nourhan Ahmed Ragheb
STATEMENT OF PROBLEM: Unscrewing the healing abutment can affect the soft tissue integration and apical migration of the biological width, which may compromise the integrity of peri-implant soft tissue. PURPOSE: The purpose of this clinical study was to determine the level of glycosaminoglycan (GAG) detected in the peri-implant crevicular fluid (PICF) between the test group (1-time abutment) and control group (healing abutment) for implant-retained mandibular overdentures...
April 9, 2024: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/38599830/exploring-prosthetic-screw-rupture-in-titanium-and-zirconia-superstructures-under-various-conditions
#33
JOURNAL ARTICLE
Myu Hayashi, Yu Kataoka, Yuji Sato, Tokiko Osawa, Kohei Yamashita, Junichi Furuya
The fastening mechanics of prosthetic screws under various conditions is crucial to the maintenance of dental implants. This study comprehensively explores the prosthetic screw rupture in titanium (Ti) and zirconia (ZrO2 ) superstructures under wet and dry conditions. Superstructures were fabricated using digital technology and subjected to tightening torque trials. Experimental results suggested that the implications of the conventionally recommended torque of 15 N•cm differ significantly between dry and wet environments...
April 11, 2024: Dental Materials Journal
https://read.qxmd.com/read/38599605/the-effect-of-supplementary-staple-fixation-on-biomechanical-properties-of-soft-tissue-graft-tibial-fixation-in-anterior-cruciate-ligament-reconstruction
#34
JOURNAL ARTICLE
Cem Yıldırım, Mehmet Demirel, Emre Koraman, Osman Görkem Muratoğlu, Fatih Yamak, Süreyya Ergün Bozdağ, Yavuz Kocabey
This study aimed to test and compare the biomechanical properties of three tibial fixation methods of anterior cruciate ligament (ACL) tendon grafts under cyclic load and load-to-failure testing in the bovine proximal tibiae, comprising (1) staple fixation alone, (2) interference screw fixation alone, and (3) interference screw fixation with a supplementary staple. Twenty-four bovine tibiae used in the study were divided into three groups (eight proximal tibiae in each group) based on tibial fixation methods of ACL tendon grafts: group A (a spiked ligament staple alone), group B (a cannulated interference screw alone), and group C (a cannulated interference screw with a supplementary staple)...
April 10, 2024: Journal of Knee Surgery
https://read.qxmd.com/read/38599454/added-transverse-screw-in-tripod-construct-increases-stiffness-in-mason-iii-radial-head-fractures-a-finite-element-analysis
#35
JOURNAL ARTICLE
Jared Walker, Deniz Erbulut, Paul R Rebgetz, Fraser J Taylor
BACKGROUND: The tripod screw configuration has been shown to offer similar stiffness characteristics to a laterally placed plate. However, concern has been raised that the construct may be prone to failure in scenarios where the screw intersects at the fracture line. We performed a finite element analysis to assess potentially ideal and unideal screw placements in the tripod construct among Mason III radial head fractures. METHODS: A 3-dimensional proximal radius model was developed using a computed tomography scan of an adult male radius...
April 8, 2024: Journal of Shoulder and Elbow Surgery
https://read.qxmd.com/read/38598981/delayed-slipped-capital-femoral-epiphysis-after-orif-for-subtrochanteric-femur-fracture
#36
Zied Mansi, Mohsen Chamakh, Ltifi Atef, Wajdi Chermiti, Haggui Ali, Gazzah Wael
INTRODUCTION AND IMPORTANCE: Slipped capital femoral epiphysis (SCFE) is a common phenomenon of the proximal femur in adolescents with an unclear etiology. It is more common in boys than girls and there does seem to be some predilection to race, weight, and age (Lehmann et al., 2006 [7]). CASE PRESENTATION: We reported a 13-year-old boy who presented with unilateral SCFE following subtrochanteric left femur fracture, which was fixed by blade plate 6 monthes before the SCFE...
March 28, 2024: International Journal of Surgery Case Reports
https://read.qxmd.com/read/38597836/the-contribution-of-the-distal-oblique-band-to-distal-radioulnar-joint-stability
#37
JOURNAL ARTICLE
Jorge L Orbay, Brandon Gardner, John J Heifner, Anthony Martin, Deana M Mercer
PURPOSE: The distal radioulnar joint (DRUJ) is supported by an array of dynamic and static stabilizers, of which the triangular fibrocartilage complex (TFCC) is the most important, and the distal interosseous ligament is next in importance. The distal oblique band (DOB) is an identifiable component of the distal interosseous ligament, found in a subset of the population. Our objective was to determine the contribution of the DOB to DRUJ stability in the presence of a disrupted TFCC. METHODS: Twenty-three above-elbow specimens were prepared by removing the TFCC and the DRUJ joint capsule, preserving the distal interosseous ligament and the pronator quadratus...
April 8, 2024: Journal of Hand Surgery
https://read.qxmd.com/read/38597509/biomechanical-behavior-of-three-maxillary-expanders-in-cleft-lip-and-palate-a-finite-element-study
#38
JOURNAL ARTICLE
Angela Maria Bautista Patiño, Monise de Paula Rodrigues, Roberto Sales Pessoa, Salomón Yezioro Rubinsky, Ki Beom Kim, Carlos José Soares, Guilherme de Araújo Almeida
This study evaluated the stress distribution in the dentoalveolar and palatal bone structures during maxillary expansion in a 17-year-old male patient with bilateral cleft lip and palate (BCLP) using expanders with dental (HYRAX) and skeletal anchorage (MARPE). For the generation of the specific finite element models, cone-beam computed tomography was used, and the DICOM files were exported to Mimics 3-Matic (Materialise) and Patran (MSC Software) software. Three specific three-dimensional models were generated: A) HYRAX: conventional four-banded hyrax screw (9 mm); B) MARPE-DS: 3 miniscrews (1...
2024: Brazilian Oral Research
https://read.qxmd.com/read/38596741/x-ray-diffraction-from-dislocation-half-loops-in-epitaxial-films
#39
JOURNAL ARTICLE
Vladimir M Kaganer
X-ray diffraction from dislocation half-loops consisting of a misfit segment with two threading arms extending from it to the surface is calculated by the Monte Carlo method. The diffraction profiles and reciprocal space maps are controlled by the ratio of the total lengths of the misfit and the threading segments of the half-loops. A continuous transformation from the diffraction characteristic of misfit dislocations to that of threading dislocations with increasing thickness of epitaxial film is studied. Diffraction from dislocations with edge- and screw-type threading arms is considered and the contributions of the two types of dislocations are compared...
April 1, 2024: Journal of Applied Crystallography
https://read.qxmd.com/read/38596584/novel-approach-to-difficult-spinal-reconstruction-bilateral-simultaneous-rib-and-iliac-crest-vascularized-bone-graft-spinoplastic-surgery
#40
JOURNAL ARTICLE
Maria Shvedova, Isra Abdulwadood, Daniel M Vernik, Max A Shrout, Jonathan L Jeger, Dylon C Buchanan, Alexander Ropper, Sebastian Winocour, Michael Bohl, Maziyar A Kalani, Edward M Reece
Pseudoarthrosis is a severe complication of spinal fusion surgery with occurrence rates as high as 35%-40%. Current options of revision surgery to correct pseudoarthrosis frequently carry high failure rates and risk of developing junctional kyphosis. Pedicled vascularized bone grafts (VBGs) are an innovative approach to boost spinal fusion rates via improving structural integrity and increasing the delivery of blood to the donor site. This versatile technique can be performed at different spinal levels without additional skin incisions and with minimal added operative time...
April 2024: Plastic and Reconstructive Surgery. Global Open
keyword
keyword
168166
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.