keyword
MENU ▼
Read by QxMD icon Read
search

STIC volumes

keyword
https://www.readbyqxmd.com/read/29603310/fetal-intelligent-navigation-echocardiography-fine-detects-98-of-congenital-heart-disease
#1
Lami Yeo, Suchaya Luewan, Roberto Romero
OBJECTIVE: Fetal intelligent navigation echocardiography (FINE) is a novel method that automatically generates and displays 9 standard fetal echocardiographic views in normal hearts by applying intelligent navigation technology to spatiotemporal image correlation (STIC) volume data sets. The main objective was to determine the sensitivity and specificity of FINE in the prenatal detection of congenital heart disease (CHD). METHODS: A case-control study was conducted in 50 fetuses with a broad spectrum of CHD (cases) and 100 fetuses with normal hearts (controls) in the second and third trimesters...
March 30, 2018: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/29395311/processing-of-fallopian-tube-ovary-and-endometrial-surgical-pathology-specimens-a-survey-of-u-s-laboratory-practices
#2
Goli Samimi, Britton Trabert, Máire A Duggan, Jennifer L Robinson, Kisha I Coa, Elizabeth Waibel, Edna Garcia, Lori M Minasian, Mark E Sherman
OBJECTIVE: Many high-grade serous carcinomas initiate in fallopian tubes as serous tubal intraepithelial carcinoma (STIC), a microscopic lesion identified with specimen processing according to the Sectioning and Extensive Examination of the Fimbria protocol (SEE-Fim). Given that the tubal origin of these cancers was recently recognized, we conducted a survey of pathology practices to assess processing protocols that are applied to gynecologic surgical pathology specimens in clinical contexts in which finding STIC might have different implications...
March 2018: Gynecologic Oncology
https://www.readbyqxmd.com/read/29287138/4d-fetal-echocardiography-an-update
#3
Greggory R DeVore, Gary Satou, Mark Sklansky
With the introduction of the electronic 4-dimensional and spatial-temporal image Correlation (e-STIC), it is now possible to obtain large volume datasets of the fetal heart that are virtually free of artifact. This allows the examiner to use a number of imaging modalities when recording the volumes that include two-dimensional real time, power and color Doppler, and B-flow images. Once the volumes are obtained, manipulation of the volume dataset allows the examiner to recreate views of the fetal heart that enable examination of cardiac anatomy...
December 2017: Echocardiography
https://www.readbyqxmd.com/read/29287134/prenatal-diagnosis-of-total-anomalous-pulmonary-venous-connection-by-2d-and-3d-fetal-echocardiography
#4
Ye Zhang, Qin Shao, Lin Sun, Shuping Ge, Yihua He
OBJECTIVE: Prenatal diagnosis of total anomalous pulmonary venous connection (TAPVC) by fetal echocardiography (FE) remains a challenge. We sought to ascertain the diagnostic accuracy of 2D and 3D spatiotemporal image correlation (STIC) FE and the potential incremental value of 3D STIC FE for prenatal diagnosis and assessment of TAPVC. METHODS: This study was conducted retrospectively in a single tertiary referral center. The study population consisted of 74 TAPVC from 17 063 fetuses by FE from August 2010 to April 2016...
December 2017: Echocardiography
https://www.readbyqxmd.com/read/29112643/assessment-of-fetal-congenital-heart-diseases-by-4-dimensional-ultrasound-using-spatiotemporal-image-correlation-pictorial-review
#5
Edward Araujo Júnior, Gabriele Tonni, Nathalie Jeanne Bravo-Valenzuela, Fabricio Da Silva Costa, Simon Meagher
The aim of this pictorial review is to describe the technical advances achieved through the application of 4-dimensional (4D) ultrasound using spatiotemporal image correlation (STIC) over conventional 2-dimensional ultrasound in the prenatal detection of congenital heart disease (CHD). Spatiotemporal image correlation is a volume imaging technique that simplifies fetal heart studies while providing more diagnostic information than is typically available from traditional 2-dimensional studies. Four-dimensional software allows the study of cardiac anatomy and function during a single cardiac cycle and has greatly contributed to diagnostic enhancement of CHD...
March 2018: Ultrasound Quarterly
https://www.readbyqxmd.com/read/28836088/feasibility-assessment-for-successfully-visualizing-the-fetal-heart-utilizing-spatiotemporal-image-correlation
#6
Eisuke Inubashiri, Sayuri Tatedo, Naomi Nishiyama, Hiina Minami, Yukio Watanabe, Noriyuki Akutagawa, Katumaru Kuroki, Masaki Sugawara, Nobuhiko Maeda, Keiji Haseyama
PURPOSE: Spatiotemporal image correlation (STIC) is an excellent imaging modality for observing the fetal heart. High-quality STIC volume data are needed for an antenatal anatomic survey to diagnose congenital heart disease. We aimed to clarify the causes of unsuccessful STIC volume data acquisition and describe a more accurate, efficient STIC examination. METHODS: This cross-sectional study of 1124 women with fetuses assessed risk factors for unsuccessful acquisition of STIC volume data...
April 2018: Journal of Medical Ultrasonics
https://www.readbyqxmd.com/read/28809063/color-and-power-doppler-combined-with-fetal-intelligent-navigation-echocardiography-fine-to-evaluate-the-fetal-heart
#7
L Yeo, R Romero
OBJECTIVE: To evaluate the performance of color and bidirectional power Doppler ultrasound combined with Fetal Intelligent Navigation Echocardiography (FINE) in examining the fetal heart. METHODS: A prospective cohort study was conducted of fetuses in the second and third trimesters with a normal heart or with congenital heart disease (CHD). One or more spatiotemporal image correlation (STIC) volume datasets, combined with color or bidirectional power Doppler (S-flow) imaging, were acquired in the apical four-chamber view...
October 2017: Ultrasound in Obstetrics & Gynecology
https://www.readbyqxmd.com/read/28641300/prenatal-diagnosis-of-dextrocardia-with-complex-congenital-heart-disease-using-fetal-intelligent-navigation-echocardiography-fine-and-a-literature-review
#8
Lami Yeo, Suchaya Luewan, Dor Markush, Navleen Gill, Roberto Romero
Fetal dextrocardia is a type of cardiac malposition where the major axis from base to apex points to the right side. This condition is usually associated with a wide spectrum of complex cardiac defects. As a result, dextrocardia is conceptually difficult to understand and diagnose on prenatal ultrasound. The advantage of four-dimensional sonography with spatiotemporal image correlation (STIC) is that this modality can facilitate fetal cardiac examination. A novel method known as fetal intelligent navigation echocardiography (FINE) allows automatic generation of nine standard fetal echocardiography views in normal hearts by applying intelligent navigation technology to STIC volume datasets...
2018: Fetal Diagnosis and Therapy
https://www.readbyqxmd.com/read/28337810/electronic-spatiotemporal-image-correlation-improves-four-dimensional-fetal-echocardiography
#9
F Guasina, F Bellussi, G Morganelli, G Salsi, G Pilu, G Simonazzi
OBJECTIVES: To compare the efficiency of electronic spatiotemporal image correlation (eSTIC) with that of conventional STIC to acquire four-dimensional (4D) fetal cardiac volumes of diagnostic quality. METHODS: This was a randomized controlled trial of 100 patients in mid-gestation with normal sonograms. In half of the cases, STIC volumes of the fetal heart were obtained with a conventional mechanical 4D probe and in the remaining cases eSTIC volumes were obtained with an electronic 4D probe...
March 2018: Ultrasound in Obstetrics & Gynecology
https://www.readbyqxmd.com/read/28224652/cardio-stic-based-reference-ranges-of-fetal-thymus-size-in-singleton-pregnancies
#10
Sirida Pittyanont, Suchaya Luewan, Theera Tongsong
OBJECTIVES: To establish the reference ranges of the fetal thymus size among Thai fetuses. METHODS: The database of spatio-temporal image correlation (cardio-STIC) was assessed to obtain the volume data sets for offline analysis. The volume data sets acquired at 16 to 38 weeks were measured for the thymus transverse diameter (TD) and the thymus/thoracic (TT) ratio at the three-vessel view. The measured values were regressed to identify the best-fitted model. RESULTS: A total of 622 volumes were successfully measured and the reference ranges of TD and TT ratio were established...
June 2017: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27314236/feasibility-study-on-prenatal-cardiac-screening-using-four-dimensional-ultrasound-with-spatiotemporal-image-correlation-a-multicenter-study
#11
Liqing Zhao, Yurong Wu, Sun Chen, Yunyun Ren, Ping Chen, Jianmei Niu, Cao Li, Kun Sun
OBJECTIVE: This study aimed at investigating the feasibility of using the spatiotemporal image correlation (STIC) technology for prenatal cardiac screening, finding factors that influence the offline evaluation of reconstructed fetal heart, and establishing an optimal acquisition scheme. METHODS: The study included 452 gravidae presenting for routine screening at 3 maternity centers at 20-38 gestational weeks. The factors influencing the quality of STIC volume data were evaluated using t test, chi-square test, and logistic regression analysis...
2016: PloS One
https://www.readbyqxmd.com/read/27309391/a-prospective-study-of-the-use-of-fetal-intelligent-navigation-echocardiography-fine-to-obtain-standard-fetal-echocardiography-views
#12
Paola Veronese, Gianna Bogana, Alessia Cerutti, Lami Yeo, Roberto Romero, Maria Teresa Gervasi
OBJECTIVE: To evaluate the performance of Fetal Intelligent Navigation Echocardiography (FINE) applied to spatiotemporal image correlation (STIC) volume datasets of the normal fetal heart in generating standard fetal echocardiography views. METHODS: In this prospective cohort study of patients with normal fetal hearts (19-30 gestational weeks), one or more STIC volume datasets were obtained of the apical four-chamber view. Each STIC volume successfully obtained was evaluated by STICLoop™ to determine its appropriateness before applying the FINE method...
2017: Fetal Diagnosis and Therapy
https://www.readbyqxmd.com/read/27174768/fetal-septum-primum-excursion-spe-and-septum-primum-excursion-index-spei-as-sonomarkers-of-fetal-anemia-using-hemoglobin-bart-s-fetuses-as-a-study-model
#13
Sirinart Sirilert, Fuanglada Tongprasert, Kasemsri Srisupundit, Suchaya Luewan, Theera Tongsong
OBJECTIVES: The objectives the study are to evaluate the effectiveness of septum primum excursion (SPE) and SPEI (SPE index, a ratio of SPE to left atrial diameter) in predicting fetal hemoglobin (Hb) Bart's disease and to determine the correlation between Hb levels and SPE/SPEI METHODS: The database of Cardio-STIC volume datasets (VDSs) of fetuses at risk of Hb Bart's disease at 18 to 22 weeks was assessed. The VDSs were blindly analyzed offline for measurements of SPE and SPEI. RESULTS: Of 180 VDSs recruited, 44 were acquired from fetuses with Hb Bart's disease, while 136 were derived from unaffected fetuses...
July 2016: Prenatal Diagnosis
https://www.readbyqxmd.com/read/27091914/how-to-acquire-cardiac-volumes-for-sonographic-examination-of-the-fetal-heart-part-1
#14
Lami Yeo, Roberto Romero
Four-dimensional sonography with spatiotemporal image correlation (STIC) technology allows acquisition of a fetal cardiac volume data set and displays a cine loop of a complete single cardiac cycle in motion. Part 1 of this 2-part article reviews STIC technology and its features, the importance of operator training/experience, and acquisition of high-quality STIC volumes, as well as factors that affect STIC volume acquisition rates. We also propose a detailed and practical stepwise approach to performing 4-dimensional sonography with STIC and begin herein by providing general recommendations...
May 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27091912/how-to-acquire-cardiac-volumes-for-sonographic-examination-of-the-fetal-heart-part-2
#15
Lami Yeo, Roberto Romero
The effective performance of fetal cardiac examination using spatiotemporal image correlation (STIC) technology requires 2 essential steps: volume acquisition and postprocessing. An important prerequisite is training sonologists to acquire high-quality volume data sets so that when analyzed, such volumes are informative. This article is part 2 of a series on 4-dimensional sonography with STIC. Part 1 focused on STIC technology and its features, the importance of operator training/experience and acquisition of high-quality STIC volumes, factors that affect STIC volume acquisition rates, and general recommendations on performing 4D sonography with STIC...
May 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/27066831/evaluation-of-right-ventricular-function-in-fetal-hypoplastic-left-heart-syndrome-using-spatio-temporal-image-correlation-stic
#16
Jing Zhang, Qichang Zhou, Yili Zhao, Qinghai Peng, Zheli Gong, Xiangdang Long
BACKGROUND: Postnatal outcome of fetuses with hypoplastic left heart syndrome (HLHS) is mainly determined by right ventricular function. In the present study we used spatio-temporal image correlation (STIC) to assess right ventricular function of fetuses with HLHS. METHODS: Three-dimensional ultrasound with STIC technique was used to acquire heart images from fetuses that had HLHS and the normal controls, between 24(+0) and 37(+6) weeks of gestation. Right ventricular end-diastolic volume (RVEDV) and right ventricular end-systolic volume (RVESV) were determined using the virtual organ computer-aided analysis software, and the parameters of right ventricular function were calculated...
April 11, 2016: Cardiovascular Ultrasound
https://www.readbyqxmd.com/read/26963426/three-and-four-dimensional-ultrasound-in-fetal-echocardiography-an-up-to-date-overview
#17
REVIEW
B M E Adriaanse, J M G van Vugt, M C Haak
Congenital heart diseases (CHD) are the most commonly overlooked lesions in prenatal screening programs. Real-time two-dimensional ultrasound (2DUS) is the conventionally used tool for fetal echocardiography. Although continuous improvements in the hardware and post-processing software have resulted in a good image quality even in late first trimester, 2DUS still has its limitations. Four-dimensional ultrasound with spatiotemporal image correlation (STIC) is an automated volume acquisition, recording a single three-dimensional (3D) volume throughout a complete cardiac cycle, which results in a four-dimensional (4D) volume...
September 2016: Journal of Perinatology: Official Journal of the California Perinatal Association
https://www.readbyqxmd.com/read/26839373/prenatal-visualization-of-the-pulmonary-and-aortic-valves-and-leaflets-is-feasible-using-4-dimensional-sonography
#18
Bauke M E Adriaanse, Lukas B Uittenbogaard, Chantal H N Tromp, Martijn W Heymans, John M G van Vugt, Monique C Haak
OBJECTIVES: The purpose of this study was to determine whether the morphologic characteristics and area of the semilunar valves in healthy fetuses and fetuses with cardiac defects can be visualized by using spatiotemporal image correlation (STIC). METHODS: Spatiotemporal image correlation volumes from 74 healthy fetuses were recorded in 5 examinations between the 15th and 36th weeks of pregnancy. Second, we recorded STIC volumes from 64 fetuses with various cardiac defects...
March 2016: Journal of Ultrasound in Medicine: Official Journal of the American Institute of Ultrasound in Medicine
https://www.readbyqxmd.com/read/26674446/the-core-contribution-of-transmission-electron-microscopy-to-functional-nanomaterials-engineering
#19
Sophie Carenco, Simona Moldovan, Lucian Roiban, Ileana Florea, David Portehault, Karine Vallé, Philippe Belleville, Cédric Boissière, Laurence Rozes, Nicolas Mézailles, Marc Drillon, Clément Sanchez, Ovidiu Ersen
Research on nanomaterials and nanostructured materials is burgeoning because their numerous and versatile applications contribute to solve societal needs in the domain of medicine, energy, environment and STICs. Optimizing their properties requires in-depth analysis of their structural, morphological and chemical features at the nanoscale. In a transmission electron microscope (TEM), combining tomography with electron energy loss spectroscopy and high-magnification imaging in high-angle annular dark-field mode provides access to all features of the same object...
January 21, 2016: Nanoscale
https://www.readbyqxmd.com/read/26668971/viewing-rate-and-reproducibility-of-papillary-muscle-areas-in-foetal-atrioventricular-valves-using-spatio-temporal-image-correlation-in-the-rendering-mode-in-congenital-heart-disease
#20
Liliam Cristine Rolo, Maria Elena Pietrolucci, Edward Araujo Júnior, Fernanda Silveira Bello Barros, Luciano Marcondes Machado Nardozza, Wellington P Martina, Antonio Fernandes Moron, Domenico Arduin, Giuseppe Rizzo
OBJECTIVE: To assess the viewing rate and reproducibility of areas of the papillary muscles (PMs) of foetal atrioventricular valves using spatio-temporal image correlation (STIC) in the rendering mode in congenital heart disease (CHD). METHODS: We retrospectively reviewed 40 4D-STIC volume datasets from different foetal CHD cases at a gestational age of 18w6d–35w6d. The following papillary muscles (PMs) were assessed: antero-lateral (MPAL) and postero-medial (MPPM) to the mitral valve and antero-superior (MPAS), inferior (MPI) and septal (MPS) to the tricuspid valve...
August 2015: Journal of Maternal-fetal & Neonatal Medicine
keyword
keyword
167268
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"