keyword
https://read.qxmd.com/read/38649919/is-ai-3d-printed-psi-an-accurate-option-for-patients-with-developmental-dysplasia-of-the-hip-undergoing-tha
#1
JOURNAL ARTICLE
Han Zheng, Eryou Feng, Yao Xiao, Xingyu Liu, Tianyu Lai, Zhibiao Xu, Jingqiao Chen, Shiwei Xie, Feitai Lin, Yiling Zhang
BACKGROUND: In traditional surgical procedures, significant discrepancies are often observed between the pre-planned templated implant sizes and the actual sizes used, particularly in patients with congenital hip dysplasia. These discrepancies arise not only in preoperative planning but also in the precision of implant placement, especially concerning the acetabular component. Our study aims to enhance the accuracy of implant placement during Total Hip Arthroplasty (THA) by integrating AI-enhanced preoperative planning with Patient-Specific Instrumentation (PSI)...
April 22, 2024: BMC Musculoskeletal Disorders
https://read.qxmd.com/read/38649874/15-year-survivorship-of-a-unique-dual-modular-femoral-stem-in-primary-hip-arthroplasty
#2
JOURNAL ARTICLE
David F Scott, Kade Eppich, Edin Mehić, Celeste Gray, Crystal Lederhos Smith, Michael Johnston
BACKGROUND: Hip offset, version, and length are interdependent femoral variables which determine stability and leg length. Balancing these competing variables remains a core challenge in hip arthroplasty. The potential benefits of modular femoral stems have been overshadowed by higher rates of failure. The objective of this study was to assess the survivorship of a unique dual-modular femoral stem at an average 15-year follow-up period. METHODS: The records of all patients with osteoarthritis who underwent primary total hip arthroplasty with this device between 2004-2009 were reviewed...
April 22, 2024: BMC Musculoskeletal Disorders
https://read.qxmd.com/read/38573818/evaluation-of-an-initial-robotic-assisted-direct-anterior-approach-cohort-receiving-a-new-short-metaphyseal-filling-collared-femoral-implant
#3
JOURNAL ARTICLE
Joshua P Rainey, Jeremy M Gililland, Kevin Marchand, Kelly Taylor, Michael A Mont, Robert C Marchand
BACKGROUND: Shorter, metaphyseal-filling collared stems have become popular with the direct anterior approach (DAA), based on their ease of broaching and insertion through less invasive surgical exposures. To aid with the DAA, robotic-assisted technology provides three-dimensional computed tomography (CT) preoperative planning and intraoperative guidance to accurately assess stem version. With other femoral stems, this has been shown to provide more accurate implant planning and improved patient outcomes...
April 4, 2024: Surgical Technology International
https://read.qxmd.com/read/38442247/modular-revision-system-for-complex-hip-revisions-a-case-series
#4
JOURNAL ARTICLE
Daniel Hameed, Brittany Oster, Bryan D Springer, Arthur L Malkani, Michael A Mont
Revision total hip arthroplasty (THA) is a procedure with many challenges, especially when patients exhibit femoral bone defects. The causes of these defects vary, ranging from removal of prior implants to aseptic loosening. As surgeons navigate these challenges, a reliable surgical system is important. One modular fluted tapered system provides surgeons with tools to address complex hip revision cases. Introduced in 2003, this system has been utilized in over 180,000 procedures, demonstrating its reliability and effectiveness...
March 1, 2024: Surgical Technology International
https://read.qxmd.com/read/38348693/determination-of-optimal-component-positioning-in-tha-using-3d-preoperative-planning
#5
JOURNAL ARTICLE
Michael LaCour, Manh Ta, Jarrod Nachtrab, Thang Nguyen, Richard Komistek
Advancements in three-dimensional (3D) preoperative planning tools can offer surgeons and design engineers detailed feedback and additional opportunities for clinical advancements. The objective of this study is to use a 3D total hip arthroplasty preoperative planning tool to compare femoral component alignment for three different stem systems. The planning tool in this study used morphology data of femoral bones gathered from a CT database, seven from postoperative patients and 63 from statistical shape models (SSMs), to suggest specific implant sizes and optimal placements in 3D to match each specific bone model...
February 13, 2024: Journal of Orthopaedic Research: Official Publication of the Orthopaedic Research Society
https://read.qxmd.com/read/38295835/migration-and-clinical-outcomes-of-a-novel-cementless-hydroxyapatite-coated-titanium-acetabular-shell-two-year-follow-up-of-a-randomized-controlled-trial-using-radiostereometric-analysis
#6
JOURNAL ARTICLE
Thies J N van der Lelij, Perla J Marang-van de Mheen, Bart L Kaptein, Lennard A Koster, Peter Ljung, Rob G H H Nelissen, Sören Toksvig-Larsen
AIMS: The objective of this study was to compare the two-year migration and clinical outcomes of a new cementless hydroxyapatite (HA)-coated titanium acetabular shell with its previous version, which shared the same geometrical design but a different manufacturing process for applying the titanium surface. METHODS: Overall, 87 patients undergoing total hip arthroplasty (THA) were randomized to either a Trident II HA or Trident HA shell, each cementless with clusterholes and HA-coating...
February 1, 2024: Bone & Joint Journal
https://read.qxmd.com/read/38205747/evaluation-of-the-native-femoral-neck-and-stem-version-reproducibility-using-robotic-arm-assisted-direct-anterior-total-hip-arthroplasty
#7
JOURNAL ARTICLE
H Geelen, V Vanryckeghem, G Leirs
The intraoperative measurement of the femoral version (FV) has gained attention in wake of an optimised combined version (CV) philosophy. Whereas some data is available utilising different approaches, to our belief this study provides the first in vivo FV data in DA-THA using the MAKO™ robot. To improve the accuracy of the femoral stem version in DA-THA, we want to ask the following question: How effectively can we reproduce the native femoral version in DA- THA using the MAKO™ robot? The first 125 total hip cases through DAA with the use of the combined anteversion concept and the help of the MAKO™ robot from a single institution, single surgeon from January 2020 to July 2021 were retrospectively analysed...
December 2023: Acta Orthopaedica Belgica
https://read.qxmd.com/read/38195511/variety-of-femoral-anteversion-and-its-measurement-in-cementless-total-hip-arthroplasty-does-robotic-technology-improve-accuracy
#8
JOURNAL ARTICLE
Hongyi Shao, Yong Huang, Dejin Yang, Wang Deng, Xiang-Dong Wu, Yixin Zhou
BACKGROUND: High-performance total hip arthroplasty (THA) depends on the accurate position of components. However, femoral anteversion is variable, and current studies only used traditional instruments to evaluate it, such as protractor and spirit level with limited cases. This study aimed to identify the variability in the measured femoral native anteversion and intraoperative stem anteversion under different measurement methods, including intraoperative robotic method. We hypothesized that robotic technology was more accurate than traditional instruments for femoral anteversion evaluation...
January 9, 2024: Journal of Orthopaedic Surgery and Research
https://read.qxmd.com/read/38071336/cemented-or-uncemented-fixation-which-allows-a-more-acceptable-prosthetic-femoral-version-in-total-hip-arthroplasty
#9
JOURNAL ARTICLE
Maria Moralidou, Anna Di Laura, Harry Hothi, Johann Henckel, Alister J Hart
BACKGROUND: Three-dimensional computed-tomography (3D-CT) planning for primary Total Hip Arthroplasty (THA) typically uses the external femoral surface; as a result, it is difficult to predict the prosthetic femoral version (PFV) for uncemented femoral stems that press-fit to the internal surface of the bone. Cemented fixation allows the surgeon to adjust the version independent of the internal femoral anatomy. We aimed to better understand the effect of the fixation type on PFV. METHODS: This was a case series study including a total of 95 consecutive patients (106 hips), who underwent uncemented (n = 81 hips) and cemented (n = 25 hips) primary THA using the posterior approach...
December 9, 2023: Journal of Orthopaedic Surgery and Research
https://read.qxmd.com/read/37763052/accuracy-of-positioning-and-risk-factors-for-malpositioning-custom-made-femoral-stems-in-total-hip-arthroplasty-a-retrospective-multicenter-analysis
#10
JOURNAL ARTICLE
Philip Mark Anderson, Tizian Heinz, Dominik Rak, Jörg Arnholdt, Boris Michael Holzapfel, Silke Dorsch, Manuel Weißenberger, Rüdiger von Eisenhart-Rothe, Max Jaenisch, Max Ertl, Michael Wagner, Henning Windhagen, Maximilian Rudert, Axel Jakuscheit
Total hip arthroplasty (THA) is commonly performed using off-the-shelf implants. In the case of a severe mismatch between the anatomy of the proximal femur and the geometry of the stem, the use of custom-made stems might become necessary. The goal of this study was to investigate the precision of the implantation of custom-made stems of one manufacturer (CTX stem, AQ Implants) and to determine risk factors for malpositioning. All patients receiving a custom-made CTX stem between 2014 and 2020 at six high-volume academic centers were retrospectively recruited...
August 22, 2023: Journal of Personalized Medicine
https://read.qxmd.com/read/37727965/defining-the-optimal-position-of-the-lipped-liner-in-combination-with-cup-orientation-and-stem-version
#11
JOURNAL ARTICLE
Alessandro Navacchia, Joseph Pagkalos, Edward T Davis
AIMS: The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice. METHODS: A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed...
September 20, 2023: Bone & Joint Research
https://read.qxmd.com/read/37662666/cemented-versus-uncemented-stems-for-revision-total-hip-replacement-a-systematic-review-and-meta-analysis
#12
JOURNAL ARTICLE
Hany Elbardesy, Fitzgerald Anazor, Mohammad Mirza, Mohamed Aly, Annis Maatough
BACKGROUND: The popularity of uncemented stems in revision total hip arthroplasty (THA) has increased in the last decade. AIM: To assess the outcomes of both cemented and uncemented stems after mid-term follow up. METHODS: This study was performed following both the Preferred Reporting Items for Systematic Reviews and Meta-analyses Statement and the Cochrane Handbook for systematic reviews and meta-analysis guidelines. Articles were chosen irrespective of country of origin or language utilized for the article full texts...
August 18, 2023: World Journal of Orthopedics
https://read.qxmd.com/read/37230697/can-version-of-the-proximal-femur-be-used-for-ct-planning-uncemented-femoral-stems
#13
JOURNAL ARTICLE
Maria Moralidou, Anna Di Laura, Johann Henckel, Alister J Hart
Three-Dimensional Computed Tomography (3D-CT) planning can predict the prosthetic femoral size in uncemented primary Total Hip Arthroplasty (THA). Correct sizing usually results in optimal varus/valgus femoral alignment; however, its effect on the Prosthetic Femoral Version (PFV) is poorly understood. Most 3D-CT planning systems use Native Femoral Version (NFV) to plan PFV. We aimed to assess the relationship between PFV and NFV in primary uncemented THA using 3D-CT analysis. Pre- and post-operative CT data was retrospectively collected from 73 patients (81 hips) undergoing primary uncemented THA with a straight-tapered stem...
June 2023: Medical Engineering & Physics
https://read.qxmd.com/read/37058277/guiding-prosthetic-femoral-version-using-3d-printed-patient-specific-instrumentation-psi-a-pilot-study
#14
JOURNAL ARTICLE
Maria Moralidou, Johann Henckel, Anna Di Laura, Alister Hart
BACKGROUND: Implantation of the femoral component with suboptimal version is associated with instability of the reconstructed hip joint. High variability of Prosthetic Femoral Version (PFV) has been reported in primary Total Hip Arthroplasty (THA). Three-dimensional (3D) Patient-Specific Instrumentation (PSI) has been recently developed and may assist in delivering a PFV within the intended range. We performed a pilot study to better understand whether the intra-operative use of a novel PSI guide, designed to deliver a PFV of 20°, results in the target range of PFV in primary cemented THA...
April 14, 2023: 3D Printing in Medicine
https://read.qxmd.com/read/36995410/tha-with-use-of-patient-specific-resurfacing-jigs-and-a-novel-customized-implant-design
#15
JOURNAL ARTICLE
Matthew Zinner, Lennart Schroeder, Cyrus A Pumilia, Eric K Lee, Gregory Martin
»: Conventional total hip arthroplasty (THA) largely remains an unguided procedure dependent on the ability and experience of the surgeon. New technologies, such as patient-specific instrumentation and robotics, have shown promising results in improving implant positioning, which has the potential to improve patient outcomes. »: The use of off-the-shelf (OTS) implant designs, however, limits the success of the technological advances since they are unable to recreate the native anatomy of the joint...
May 1, 2022: JBJS Reviews
https://read.qxmd.com/read/36769632/age-and-sex-influence-the-use-of-modular-femoral-components-in-total-hip-arthroplasty-performed-for-primary-osteoarthritis
#16
JOURNAL ARTICLE
Francesco Castagnini, Barbara Bordini, Monica Cosentino, Michele Di Liddo, Giuseppe Tella, Claudio Masetti, Francesco Traina
The impact of age and sex on femoral component choices in modular total hip arthroplasty (THA) is still unknown. A regional arthroplasty registry was interrogated about a modular stem in THA performed for primary osteoarthritis, with the aims to assess the influence of age and sex on stems sizes and neck choices. A total of 6830 THAs were included: all THAs had a modular stem (with 15 necks and 27 combinations per side). Patients were stratified by age in decades and sex. Necks were grouped according to the type of correction...
January 27, 2023: Journal of Clinical Medicine
https://read.qxmd.com/read/36725766/comparison-of-single-taper-and-dual-taper-versions-of-the-same-stem-design-in-total-hip-arthroplasty-for-primary-osteoarthritis
#17
JOURNAL ARTICLE
Francesco Castagnini, Barbara Bordini, Monica Cosentino, Enrico Tassinari, Giulia Guizzardi, Francesco Traina
BACKGROUND: In total hip arthroplasty (THA), the outcomes of single taper (ST) and dual taper (DT) versions of the same stem design have been scarcely studied. A registry study comparing ST and DT versions of the same stem design was designed, aiming to assess: (1) the survival rates and the hazard ratios for failure; (2) the survival rates and the hazard ratios for failure using stem-focused endpoints. MATERIAL AND METHODS: A regional arthroplasty registry was interrogated about stem designs with ST and DT versions in cementless THAs performed for primary osteoarthritis...
February 1, 2023: Journal of Orthopaedics and Traumatology: Official Journal of the Italian Society of Orthopaedics and Traumatology
https://read.qxmd.com/read/36451134/restoration-of-hip-geometry-after-total-hip-arthroplasty-retrospective-comparison-of-two-short-stems-and-one-straight-stem
#18
JOURNAL ARTICLE
Werner Maurer-Ertl, Joerg Friesenbichler, Michael Pfann, Michael Maier, Patrick Reinbacher, Andreas Leithner, Maria A Smolle
BACKGROUND: The preservation or restoration of hip geometry following total hip arthroplasty (THA) is of importance, considering that alterations in the centrum-collum-diaphysis (CCD)-angle, femoral offset (FO), acetabular offset (AO) and total offset (TO) change hip biomechanics. Therefore, the most suitable implant should be used. The aim of this study was to compare the ability of two short-stem-systems and one straight-stem-system to reconstruct hip geometry. METHODS: Two-hundred-fifty-one patients (mean age: 62...
November 30, 2022: BMC Musculoskeletal Disorders
https://read.qxmd.com/read/36317354/validating-the-use-of-3d-biplanar-radiography-versus-ct-when-measuring-femoral-anteversion-after-total-hip-arthroplasty-a-comparative-study
#19
JOURNAL ARTICLE
Christopher G Anderson, Zachary R Brilliant, Seong J Jang, Ruba Sokrab, David J Mayman, Jonathan M Vigdorchik, Peter K Sculco, Seth A Jerabek
AIMS: Although CT is considered the benchmark to measure femoral version, 3D biplanar radiography (hipEOS) has recently emerged as a possible alternative with reduced exposure to ionizing radiation and shorter examination time. The aim of our study was to evaluate femoral stem version in postoperative total hip arthroplasty (THA) patients and compare the accuracy of hipEOS to CT. We hypothesize that there will be no significant difference in calculated femoral stem version measurements between the two imaging methods...
November 2022: Bone & Joint Journal
https://read.qxmd.com/read/36267395/functional-femoral-anteversion-axial-rotation-of-the-femur-and-its-implications-for-stem-version-targets-in-total-hip-arthroplasty
#20
JOURNAL ARTICLE
Max Hardwick-Morris, Joshua Twiggs, Kunaal Kacker, Brad Miles, Jitendra Balakumar
BACKGROUND: Acetabular and femoral component positioning are important considerations in reducing adverse outcomes after total hip arthroplasty (THA). Previous assessments of femoral anteversion examined anatomic femoral anteversion (AFA) referenced to anatomic landmarks. However, this does not provide a functional understanding of the femur's relationship to the hip. We investigate a new measurement, functional femoral anteversion (FFA), and sought to measure its variability across a large sample of patients undergoing THA...
December 2022: Arthroplasty Today
keyword
keyword
163062
1
2
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.