keyword
MENU ▼
Read by QxMD icon Read
search

4 mm implant

keyword
https://www.readbyqxmd.com/read/28817742/minimum-abutment-height-to-eliminate-bone-loss-influence-of-implant-neck-design-and-platform-switching
#1
Sergio Spinato, Pablo Galindo-Moreno, Fabio Bernardello, Davide Zaffe
PURPOSE: This retrospective study quantitatively analyzed the minimum prosthetic abutment height to eliminate bone loss after 4.7-mm-diameter implant placement in maxillary bone and how grafting techniques can affect the marginal bone loss in implants placed in maxillary areas. MATERIALS AND METHODS: Two different implant types with a similar neck design were singularly placed in two groups of patients: the test group, with platform-switched implants, and the control group, with conventional (non-platform-switched) implants...
August 17, 2017: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/28817740/influence-of-microtextured-implant-surfaces-on-peri-implantitis-and-its-treatment-a-preclinical-trial
#2
Juan C Rodriguez, Tapan Koticha, Diana L Eubanks, Ivan Rudek, Fred J Molz, Ludovica Chiavaccini, Andrew Claude, Steven Elder, Hom-Lay Wang
PURPOSE: The prevalence of peri-implantitis has increased significantly, forcing clinicians to search for ways to prevent it. Laser-microtextured surfaces promote soft tissue attachment and provide a tight seal around implants. Hence, the aim of this study was to examine the clinical, radiographic, and histologic features of ligature-induced peri-implantitis, as well as the effect of surgical treatment of these induced peri-implantitis lesions on laser-microtextured implants in a controlled animal model...
August 17, 2017: International Journal of Oral & Maxillofacial Implants
https://www.readbyqxmd.com/read/28817137/immediately-loaded-implant-supported-overdentures-retained-by-a-milled-bar-an-up-to-5-year-retrospective-clinical-study
#3
Franco Villa, Felice Roberto Grassi, Maja Popovic, Raffaele Sordillo, Zamira Kalemaj
This study was conducted as an up-to-5-year retrospective investigation estimating survival rate, marginal bone loss (MBL), patient satisfaction, complications, and required prosthodontic maintenance for immediately loaded, milled bar-retained, implant-supported overdentures (ISOs). A total of 60 patients, 69 overdentures, and 179 implants were examined. The implant survival rate was 96.65%, and the mean MBL was 0.57 mm (SD 0.52). High subjective satisfaction ratings, ranging from 3 to 5 with a mean of 4.3 (SD 0...
September 2017: International Journal of Periodontics & Restorative Dentistry
https://www.readbyqxmd.com/read/28817132/plasma-of-argon-cleaning-treatment-on-implant-abutments-in-periodontally-healthy-patients-six-years-postloading-results-of-a-randomized-controlled-trial
#4
Luigi Canullo, Marco Tallarico, Miguel Penarrocha, Giuseppe Corrente, Joseph Fiorellini, David Penarrocha
The aim of this randomized, match-paired, triple-blinded, controlled clinical trial was to assess the 6-year radiographic changes around customized platform-switched abutments placed according to the one abutment-one time concept, with and without plasma of argon cleaning treatment. A total of 20 periodontally healthy patients received one maxillary implant between the premolars. Immediately before stage 2 surgery and abutment connection, patients were randomly assigned to the control (cleaning protocol by steam) or test group (plasma of argon treatment)...
September 2017: International Journal of Periodontics & Restorative Dentistry
https://www.readbyqxmd.com/read/28816291/-influence-of-the-interforaminal-arch-form-of-edentulous-mandibles-on-design-of-all-on-4-preliminary-research-based-on-conebeam-computed-tomography
#5
S Y Li, G Li, H L Feng, S X Pan
OBJECTIVE: To classify the interforaminal arch form of edentulous mandibles by measuring the anterior-posterior distance (A-P distance) of implants planned to be inserted in "All-on-4" protocol using conebeam computed tomography (CBCT) data, and to investigate the influence of the arch form on the "All-on-4" distally tilted implants. METHODS: Seventy-four CBCT images of edentulous mandibles were collected, including 35 males and 39 females respectively. "All-on-4"implant supported fixed prostheses were designed for these patients based on the CBCT data...
August 18, 2017: Beijing da Xue Xue Bao. Yi Xue Ban, Journal of Peking University. Health Sciences
https://www.readbyqxmd.com/read/28816146/quality-assessment-of-stereotactic-radiosurgery-of-a-melanoma-brain-metastases-model-using-a-mouselike-phantom-and-the-small-animal-radiation-research-platform
#6
Cheng-Chia Wu, Kunal R Chaudhary, Yong Hum Na, David Welch, Paul J Black, Adam M Sonabend, Peter Canoll, Yvonne M Saenger, Tony J C Wang, Cheng-Shie Wuu, Tom K Hei, Simon K Cheng
PURPOSE: To establish a novel preclinical model for stereotactic radiosurgery (SRS) with combined mouselike phantom quality assurance in the setting of brain metastases. METHODS AND MATERIALS: C57B6 mice underwent intracranial injection of B16-F10 melanoma cells. T1-weighted postcontrast magnetic resonance imaging (MRI) was performed on day 11 after injection. The MRI images were fused with cone beam computed tomography (CBCT) images using the Small Animal Radiation Research Platform (SARRP)...
September 1, 2017: International Journal of Radiation Oncology, Biology, Physics
https://www.readbyqxmd.com/read/28810287/seeding-density-is-a-crucial-determinant-for-the-in-vivo-vascularisation-capacity-of-adipose-tissue-derived-microvascular-fragments
#7
T Später, C Körbel, F S Frueh, R M Nickels, M D Menger, M W Laschke
Adipose tissue-derived microvascular fragments (ad-MVF) represent effective vascularisation units for the seeding of dermal substitutes. However, particularly in case of extensive skin defects, the required amounts of donor fat tissue for the harvesting of ad-MVF may not always be available. Therefore, we herein determined the lowest ad-MVF density needed to induce a sufficient vascularisation and incorporation of seeded implants. Collagen-glycosaminoglycan matrices (Integra®; diameter: 4 mm) were seeded with 15,000 (HD), 10,000 (MD) and 5,000 (LD) ad-MVF and implanted into full-thickness skin defects within mouse dorsal skinfold chambers, to analyse their in vivo vascularisation and incorporation...
August 15, 2017: European Cells & Materials
https://www.readbyqxmd.com/read/28809637/-comparison-of-short-therm-results-of-conservative-versus-operative-treatment-of-distal-ulna-fractures-associated-with-distal-radius-fracture-treated-by-plate-osteosynthesis
#8
P Meluzinová, L Kopp, P Dráč, K Edelmann, P Obruba
PURPOSE OF THE STUDY The study aims to evaluate and compare the results of conservative and operative treatment of individual types of distal ulna fractures associated with distal radius fracture treated by plate osteosynthesis and to verify the conclusions of the other authors regarding the recommended therapeutic procedures in these fractures. MATERIAL AND METHODS In the period from 08/2013 to 09/2015, a total of 81 patients participated in the prospective randomised study, with the mean follow-up period of 24 months (6-36)...
2017: Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca
https://www.readbyqxmd.com/read/28809634/-wear-and-roughness-of-bearing-surface-in-retrieved-polyethylene-bicon-plus-cups
#9
M Ranuša, J Gallo, M Hobza, M Vrbka, D Nečas, M Hartl
PURPOSE OF THE STUDY By 7th December 2016, 4,755 Bicon-Plus cups in total were implanted in the Czech Republic. Some of them have been continuously re-operated, while the most frequent reason of failure is polyethylene wear and aseptic loosening. The present study is focused on surface analysis of retrieved polyethylene Bicon-Plus cups and the determination of the roughness of their bearing surfaces. MATERIAL AND METHODS In this study, we had 13 high molecular weight polyethylene cups with the average time in situ of 8...
2017: Acta Chirurgiae Orthopaedicae et Traumatologiae Cechoslovaca
https://www.readbyqxmd.com/read/28808925/recommendations-of-the-spanish-brachytherapy-group-geb-of-spanish-society-of-radiation-oncology-seor-and-the-spanish-society-of-medical-physics-sefm-for-high-dose-rate-hdr-non-melanoma-skin-cancer-brachytherapy
#10
S Rodríguez, M Arenas, C Gutierrez, J Richart, J Perez-Calatayud, F Celada, M Santos, A Rovirosa
Clinical indications of brachytherapy in non-melanoma skin cancers, description of applicators and dosimetry recommendations are described based on the literature review, clinical practice and experience of Spanish Group of Brachytherapy and Spanish Society of Medical Physics reported in the XIV Annual Consensus Meeting on Non Melanoma Skin Cancer Brachytherapy held in Benidorm, Alicante (Spain) on October 21st, 2016. All the recommendations for which consensus was achieved are highlighted in blue. Regular and small surfaces may be treated with Leipzig, Valencia, flap applicators or electronic brachytherapy (EBT)...
August 14, 2017: Clinical & Translational Oncology
https://www.readbyqxmd.com/read/28808628/distal-radius-volar-rim-plate-technical-and-radiographic-considerations
#11
Michelle Spiteri, Darren Roberts, Wayne Ng, Jamie Matthews, Dominic Power
AIM: To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS: This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS: Twenty-six of the 382 internally fixed distal radial fractures at our unit (6...
July 18, 2017: World Journal of Orthopedics
https://www.readbyqxmd.com/read/28803418/clinical-results-after-microincision-biaxial-cataract-surgery-and-implantation-of-an-incise-intraocular-lens
#12
Wojciech Lubiński, Marta Kirkiewicz, Karolina Podborączyńska-Jodko
PURPOSE: To evaluate clinical outcomes after uncomplicated microincision biaxial cataract surgery and implantation of Incise intraocular lens (IOL). METHODS: This study included 47 eyes of 29 patients (mean age 62.2 ± 8.6 years), who underwent 1.4-mm biaxial cataract surgery with implantation of the Incise IOL (Bausch and Lomb). At third month, surgically induced astigmatism (SIA) was calculated. Three, 6 and 12 months postoperatively, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), corrected near visual acuity (CNVA) LogMAR ETDRS, spherical equivalent refraction (SER), photopic distance corrected contrast sensitivity (CS) with and without glare (85 cd/m(2)) (CSV-1000) were assessed...
August 12, 2017: International Ophthalmology
https://www.readbyqxmd.com/read/28803112/in-vivo-documentation-of-shape-and-position-changes-of-mri-visible-mesh-placed-in-rectovaginal-septum
#13
Urbankova Iva, Sindhwani Nikhil, Callewaert Geertje, Turri Alice, Rinkijevic Rita, Hympanova Lucie, Feola Andrew, Deprest Jan
BACKGROUND AND OBJECTIVE: Large deformations in synthetic meshes used in pelvic organ prolapse surgery may lead to suboptimal support for the underlying tissue, graft-related complications as well as recurrence. Our aim was to quantify in vivo longitudinal changes in mesh shape and geometry in a large animal model. We compare two commonly used mesh shapes, armed and flat, that are differently affixed. The secondary outcomes were active and passive biomechanical properties. METHODS: A total of 18 animals were used...
August 5, 2017: Journal of the Mechanical Behavior of Biomedical Materials
https://www.readbyqxmd.com/read/28801202/a-biomechanical-study-comparing-proximal-femur-nail-and-proximal-femur-locking-compression-plate-in-fixation-of-reverse-oblique-proximal-femur-fractures
#14
Ashutosh Kumar Singh, N Narsaria, R K Gupta
BACKGROUND: The reverse oblique trochanteric fractures are common fractures and its treatment poses a challenge. The purpose of this study was to compare the biomechanical parameters of the construct using proximal femoral nail (PFN) and proximal femoral locking compression plates (PFLCP) in these fractures using cadaveric specimens. MATERIALS AND METHODS: Twenty freshly harvested cadaveric femoral specimens were randomly assigned to two groups after measuring bone mineral density, ten of which were implanted with PFN and the other ten with PFLCP...
May 22, 2017: Injury
https://www.readbyqxmd.com/read/28798987/maximization-of-interventricular-conduction-time-by-means-of-quadripolar-leads-for-cardiac-resynchronization-therapy
#15
Giuseppe Stabile, Valter Bianchi, Francesco Solimene, Assunta Iuliano, Quintino Parisi, Patrizia Pepi, Mario Bocchiardo, Francesco Urraro, Antonio De Simone, Roberto Ospizio, Antonio D'Onofrio
PURPOSE: Identifying the left ventricular (LV) site associated with the maximum spontaneous interventricular conduction time (right ventricle (RV)-to-LV interval) has proved to be an effective strategy for optimal LV pacing site selection in cardiac resynchronization therapy (CRT). The aim of our study was to determine whether quadripolar LV lead technology allows RV-to-LV interval maximization. METHODS: We enrolled 108 patients undergoing implantation of a CRT system using an LV quadripolar lead and 114 patients who received a bipolar lead...
August 10, 2017: Journal of Interventional Cardiac Electrophysiology: An International Journal of Arrhythmias and Pacing
https://www.readbyqxmd.com/read/28798929/accuracy-of-bone-measurements-in-the-vicinity-of-titanium-implants-in-cbct-data-sets-a-comparison-of-radiological-and-histological-findings-in-minipigs
#16
Alexander Gröbe, Jan Semmusch, Maximilian Schöllchen, Henning Hanken, Michael Hahn, Wolfgang Eichhorn, Gerhard Schön, Ole Jung, Jamal M Stein, Aline Reitmeier, Max Heiland, Ralf Smeets, Clarissa Precht
PURPOSE: The aim of this animal study was the determination of accuracy of bone measurements in CBCT (cone-beam computed tomography) in close proximity to titanium implants. MATERIAL AND METHODS: Titanium implants were inserted in eight Göttingen minipigs. 60 implants were evaluated histologically in ground section specimen and radiologically in CBCT in regard to thickness of the buccal bone. With random intercept models, the difference of histologic measurements and CBCT measurements of bone thickness was calculated...
2017: BioMed Research International
https://www.readbyqxmd.com/read/28798783/mesh-covered-roadsaver-stent-as-a-new-treatment-modality-for-symptomatic-or-high-risk-carotid-stenosis
#17
Roman Machnik, Piotr Paluszek, Łukasz Tekieli, Karolina Dzierwa, Damian Maciejewski, Mariusz Trystuła, Andrzej Brzychczy, Krzysztof Banaszkiewicz, Robert Musiał, Piotr Pieniążek
INTRODUCTION: Prevention of periprocedural stroke has a crucial role in carotid artery stenting (CAS) procedures. AIM: To assess retrospectively 30-day safety and effectiveness of 41 procedures of internal and common carotid artery stenting using the Roadsaver double nitinol layer micromesh stent in 40 non-consecutive patients with symptomatic or high-risk carotid artery stenosis. MATERIAL AND METHODS: The patients were men (n = 31) and women (n = 9); mean age was 67...
2017: Postępy W Kardiologii Interwencyjnej, Advances in Interventional Cardiology
https://www.readbyqxmd.com/read/28797431/implantation-and-30-day-follow-up-on-all%C3%A2-4-valve-sizes-within-the-portico-transcatheter-aortic-bioprosthetic-family
#18
Helge Möllmann, Axel Linke, David M Holzhey, Thomas Walther, Ganesh Manoharan, Ulrich Schäfer, Karl Heinz-Kuck, Ad J Van Boven, Simon R Redwood, Jan Kovac, Christian Butter, Lars Søndergaard, Alexander Lauten, Gerhard Schymik, Stephen G Worthley
OBJECTIVES: The aim of this study was to evaluate the short-term safety and performance of the full range of valve sizes offered within the Portico transcatheter aortic valve replacement system. BACKGROUND: The Portico transcatheter aortic heart valve is a fully resheathable, repositionable, and self-expanding bioprosthesis designed to achieve optimal valve position and hemodynamic performance and limit conduction disturbances. METHODS: Patients (n = 222) with symptomatic (New York Heart Association functional class ≥II) severe aortic stenosis considered by a multidisciplinary heart team to be at high surgical risk were recruited between December 2011 and September 2015 in this prospective, nonrandomized, multicenter study...
August 14, 2017: JACC. Cardiovascular Interventions
https://www.readbyqxmd.com/read/28797353/clinical-outcomes-with-a-repositionable-self-expanding-transcatheter-aortic%C3%A2-valve%C3%A2-prosthesis-the-international-forward-study
#19
Eberhard Grube, Nicolas M Van Mieghem, Sabine Bleiziffer, Thomas Modine, Johan Bosmans, Ganesh Manoharan, Axel Linke, Werner Scholtz, Didier Tchétché, Ariel Finkelstein, Ramiro Trillo, Claudia Fiorina, Antony Walton, Christopher J Malkin, Jae K Oh, Hongyan Qiao, Stephan Windecker
BACKGROUND: Clinical outcomes in large patient populations from real-world clinical practice with a next-generation self-expanding transcatheter aortic valve are lacking. OBJECTIVES: This study sought to document the clinical and device performance outcomes of transcatheter aortic valve replacement (TAVR) with a next-generation, self-expanding transcatheter heart valve (THV) system in patients with severe symptomatic aortic stenosis (AS) in routine clinical practice...
August 15, 2017: Journal of the American College of Cardiology
https://www.readbyqxmd.com/read/28795567/buckled-thin-film-transistors-and-circuits-on-soft-elastomers-for-stretchable-electronics
#20
Giuseppe Cantarella, Christian Vogt, Raoul Hopf, Niko Münzenrieder, Panagiotis Andrianakis, Luisa Petti, Alwin Daus, Stefan Knobelspies, Lars Büthe, Gerhard Troester, Giovanni A Salvatore
Although recent progress in the field of flexible electronics has allowed the realization of biocompatible and conformable electronics, systematic approaches which combine high bendability (< 3 mm bending radius), high stretchability ( > 3-4 %) and low complexity in the fabrication process are still missing. Here, we show a technique to induce randomly-oriented and customized wrinkles on the surface of a biocompatible elastomeric substrate, where Thin-Film Transistors (TFTs) and circuits (inverter and logic NAND gates) based on Amorphous-IGZO are fabricated...
August 10, 2017: ACS Applied Materials & Interfaces
keyword
keyword
15933
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"