https://www.readbyqxmd.com/read/27924213/drug-eluting-stents-appear-superior-to-bare-metal-stents-for-vein-graft-pci-in-vessels-up-to-a-stent-diameter-of-4-mm
#1
Oliver P Guttmann, Daniel A Jones, Kassem A Safwan, Sean Gallagher, Krishnaraj S Rathod, Steve Hamshere, Elliot J Smith, Ajay K Jain, Anthony Mathur, Andrew Wragg, Charles J Knight, Roshan Weerackody
BACKGROUND: Research trials have shown improved short-term outcome with drug-eluting stents (DES) over bare metal stents (BMS) in saphenous vein graft (SVG) percutaneous coronary intervention (PCI), primarily by reducing target vessel revascularization (TVR) for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter. METHODS: Data were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011...
January 2016: Heart International
https://www.readbyqxmd.com/read/27922962/retention-and-mechanical-behavior-of-attachment-systems-for-implant-retained-auricular-prostheses
#2
Eder Alberto Sigua-Rodriguez, Douglas Rangel Goulart, Zarina Tatia Santos, Natalia Alvarez-Pinzon, Sergio Olate, José Ricardo de Albergaria-Barbosa
OBJECTIVE: Auricular prostheses are artificial substitutes for facial defects. The retention of these has often been a problem. This study aimed to evaluate the mechanical behavior of 3 retained auricular prosthetic connections when submitted to a mechanical cycling test. MATERIALS AND METHODS: Twelve samples with installed implants were obtained and divided into 3 groups according to their retention system with 4 samples in each group. I: bar-clip system; II: magnet system; and III: ball/o-ring system...
December 5, 2016: Journal of Craniofacial Surgery
https://www.readbyqxmd.com/read/27922455/primary-stability-of-cylindrical-and-conical-dental-implants-in-relation-to-insertion-torque-a-comparative-ex-vivo-evaluation
#3
Henning Staedt, Victor Palarie, Arne Staedt, Jens M Wolf, Karl Martin Lehmann, Peter Ottl, Peer W Kämmerer
INTRODUCTION: The aim of this ex vivo study was to investigate the influence of different insertion torques on primary stability of a conical and a cylindrical implant system. MATERIALS AND METHODS: Thirty-two dental implants (Astra Tech OsseoSpeed 5.0 S × 11 mm cylindrical [n = 16] and 5.0 × 11 mm conical [n = 16]) were inserted with 20, 30, 40, and 45 N·cm into fresh porcine bone of mixed trabecular-cortical quality. Before insertion, bone quality was assessed via cone beam tomography...
December 2, 2016: Implant Dentistry
https://www.readbyqxmd.com/read/27917354/results-of-a-hydroxyapatite-coated-femoral-stem-corail-in-chinese-a-minimum-10-year-follow-up
#4
Jianda Xu, Zikang Xie, Jianning Zhao, Yi Gao, Hong Zhao, Libo Peng, Yuxing Qu
BACKGROUND: Due to the adverse effects of cemented hip arthroplasty, uncemented stems with hydroxyapatite (HA) coating reduces these risks and enhanced integration. The concept of an extensive HA coating for the fixation of a tapered femoral stem (Corail(®)) was introduced, which can achieve durable biological fixation and preserve normal periprosthetic bone activity. Here we describe the clinical and radiological outcome in patients with the Corail(®) stem. METHODS: 92 total hip replacements in 81 patients using the Corail(®) stem were followed-up...
2016: SpringerPlus
https://www.readbyqxmd.com/read/27916373/antibiotic-releasing-microspheres-prevent-mesh-infection-in%C3%A2-vivo
#5
Kevin T Grafmiller, Sean T Zuckerman, Clayton Petro, Lijia Liu, Horst A von Recum, Michael J Rosen, Julius N Korley
BACKGROUND: Infection remains a dreaded complication after implantation of surgical prosthetics, particularly after hernia repair with synthetic mesh. We previously demonstrated the ability of a newly developed polymer to provide controlled release of an antibiotic in a linear fashion over 45 d. We subsequently showed that coating mesh with the drug-releasing polymer prevented a Staphylococcus aureus (SA) infection in vivo. To broaden the applicability of this technology, the polymer was synthesized as isolated "microspheres" and loaded with vancomycin (VM) before conducting a noninferiority analysis...
November 2016: Journal of Surgical Research
https://www.readbyqxmd.com/read/27915343/intravitreal-dexamethasone-implant-for-the-treatment-of-postoperative-macular-edema
#6
André Klamann, Katharina Böttcher, Philipp Ackermann, Gerd Geerling, Marc Schargus, Rainer Guthoff
INTRODUCTION: Macular edema after cataract surgery (Irvine-Gass syndrome) or pars plana vitrectomy is a postoperative complication which can lead to permanent visual loss. Increased inflammatory substances, such as prostaglandins and cytokines, are discussed to be causative. Currently, there are no evidence-based guidelines for the treatment of postoperative macular edema. Intravitreal dexamethasone (DEX) could be effective by its anti-inflammatory effect. We examined the functional and morphological results of treatment with 0...
December 3, 2016: Ophthalmologica. Journal International D'ophtalmologie
https://www.readbyqxmd.com/read/27913738/extracorporeal-membrane-oxygenation-in-transcatheter-aortic-valve-replacement
#7
Elena Dolmatova, Kasra Moazzami, Thomas P Cocke, Elie Elmann, Pranay Vaidya, Arthur F Ng, Kumar Satya, Rajeev L Narayan
BACKGROUND: Patients undergoing transcatheter aortic valve replacement can experience severe perioperative complications leading to hemodynamic instability and death. Venoarterial extracorporeal membrane oxygenation can be used to provide cardiorespiratory support during this time. METHODS: From 2012 to 2015, of 247 patients who underwent transcatheter aortic valve replacement, 6 (2.42%) required extracorporeal membrane oxygenation support. Their mean age was 82 ± 7...
December 2, 2016: Asian Cardiovascular & Thoracic Annals
https://www.readbyqxmd.com/read/27909134/what-is-the-morbidity-of-a-non-invasive-growing-prosthesis
#8
M M Gilg, C L Gaston, M C Parry, L Jeys, A Abudu, R M Tillman, S R Carter, R J Grimer
AIMS: Extendible endoprostheses have been available for more than 30 years and have become more sophisticated with time. The latest generation is 'non-invasive' and can be lengthened with an external magnetic force. Early results have shown a worryingly high rate of complications such as infection. This study investigates the incidence of complications and the need for further surgery in a cohort of patients with a non-invasive growing endoprosthesis. PATIENTS AND METHODS: Between 2003 and June 2014, 50 children (51 prostheses) had a non-invasive growing prosthesis implanted for a primary bone sarcoma...
December 2016: Bone & Joint Journal
https://www.readbyqxmd.com/read/27908149/real-time-electromagnetic-seed-drop-detection-for-permanent-implants-brachytherapy-technology-overview-and-performance-assessment
#9
E Racine, G Hautvast, D Binnekamp, L Beaulieu
PURPOSE: To describe the principles and report on the performance of a novel real-time electromagnetic (EM) seed drop detection technology for permanent implants brachytherapy procedures. METHODS: A novel EM hollow needle prototype was recently developed by Philips. It possesses standard 3D tracking capability as well as a seed drop detection mechanism, both performed from a single custom built EM sensor. The detection mechanism is based on the magnetic permeability changes in the sensor as the seeds pass through...
December 2016: Medical Physics
https://www.readbyqxmd.com/read/27906085/tissue-engineered-cardiac-patch-seeded-with-human-induced-pluripotent-stem-cell-derived-cardiomyocytes-promoted-the-regeneration-of-host-cardiomyocytes-in-a-rat-model
#10
Tadahisa Sugiura, Narutoshi Hibino, Christopher K Breuer, Toshiharu Shinoka
BACKGROUND: Thousands of babies are born with congenital heart defects that require surgical repair involving a prosthetic implant. Lack of growth in prosthetic grafts is especially detrimental in pediatric surgery. Cell seeded biodegradable tissue engineered grafts are a novel solution to this problem. The purpose of the present study is to evaluate the feasibility of seeding human induced pluripotent stem cell derived cardiomyocytes (hiPS-CMs) onto a biodegradable cardiac patch. METHODS: The hiPS-CMs were cultured on a biodegradable patch composed of a polyglycolic acid (PGA) and a 50:50 poly (l-lactic-co-ε-caprolactone) copolymer (PLCL) for 1 week...
December 1, 2016: Journal of Cardiothoracic Surgery
https://www.readbyqxmd.com/read/27904718/biomechanical-analysis-of-a-novel-wedge-locking-plate-in-a-porcine-tibial-model
#11
Jeong-Ku Ha, Chul Hyun Yeom, Ho Su Jang, Han Eui Song, Sung Jae Lee, Kang Hee Kim, Kyu Sung Chung, Mahendar Gururaj Bhat, Jin Goo Kim
BACKGROUND: The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. METHODS: A uniform 8-mm OWHTO was performed in 12 porcine tibiae. Six of them were subsequently fixed with the plate without a wedge, whereas the other 6 were additionally reinforced with a metal wedge of 8 mm. Biomechanical properties (stiffness, displacement of the osteotomy gap, and failure load) were evaluated under axial load...
December 2016: Clinics in Orthopedic Surgery
https://www.readbyqxmd.com/read/27904088/the-effect-of-implant-diameter-on-strain-around-implants-retaining-a-mandibular-overdenture-with-locator-attachments-an-in-vitro-study
#12
Moustafa Abdou Elsyad, Ahmed Abdelsalam Elhddad, Ahmed Samir Khirallah
This study evaluated the effect of implant diameter on strain around implants retaining mandibular overdentures with Locator attachments. Three mandibular acrylic resin models were constructed with 2 implants inserted in canine areas and classified according to implant diameter into 3 groups: large (4.2 mm), medium (3.7 mm), and small (3.3 mm) diameter implants. Duplicate dentures were connected to the implants with Locator attachments. Four strain gauges were bonded to the acrylic resin at mesial, distal, buccal and lingual surfaces of each implant and strain was measured at loading and non-loading sides during 1st premolar and 1st molar loading...
2016: Dental Materials Journal
https://www.readbyqxmd.com/read/27902850/biomechanical-comparison-of-2-veterinary-locking-plates-to-monocortical-screw-polymethylmethacrylate-fixation-in-canine-cadaveric-cervical-vertebral-column
#13
Bianca F Hettlich, Geoffrey T Fosgate, Alan S Litsky
OBJECTIVE: To compare the biomechanical properties of 2 veterinary locking plates and monocortical screws/polymethylmethacrylate (PMMA) fixation in canine cadaveric cervical vertebral columns. STUDY DESIGN: Biomechanical cadaveric study. MATERIALS: Nineteen cervical vertebral columns (C2-C7) from large breed, skeletally mature, canine cadavers were used. A cortical ring was placed as a disk spacer at C4-C5 in all specimens. Seven vertebral columns were plated at C4-C5 with two 4-hole, 3...
November 30, 2016: Veterinary Surgery: VS
https://www.readbyqxmd.com/read/27901393/comparison-of-desired-radiographic-advancement-distance-and-true-advancement-distance-required-for-patellar-tendon-tibial-plateau-angle-reduction-to-the-ideal-90%C3%A2-in-dogs-by-use-of-the-modified-maquet-technique
#14
Paul Pillard, Veronique Livet, Quentin Cabon, Camille Bismuth, Juliette Sonet, Denise Remy, Didier Fau, Claude Carozzo, Eric Viguier, Thibaut Cachon
OBJECTIVE To evaluate the validity of 2 radiographic methods for measurement of the tibial tuberosity advancement distance required to achieve a reduction in patellar tendon-tibial plateau angle (PTA) to the ideal 90° in dogs by use of the modified Maquet technique (MMT). SAMPLE 24 stifle joints harvested from 12 canine cadavers. PROCEDURES Radiographs of stifle joints placed at 135° in the true lateral position were used to measure the required tibial tuberosity advancement distance with the conventional (A(M)) and correction (A(E)) methods...
December 2016: American Journal of Veterinary Research
https://www.readbyqxmd.com/read/27899119/clinical-outcome-and-hemodynamic-behavior-of-the-labcor-dokimos-plus-aortic-valve
#15
Torsten Christ, Konstantin Zhigalov, Wolfgang Konertz, Sebastian Holinski
BACKGROUND: The Labcor Dokimos Plus (LDP) is a stented externally mounted pericardial aortic bioprosthesis, which was recently introduced in Europe. Aims of the study are evaluation of operative and postoperative results as well as hemodynamic performance. METHODS: One hundred consecutive patients with a mean age of 65.9 ± 10.7 years (range 35-87) and a mean EuroSCORE II of 3.1 ± 3.9 (range 0.67-24.5) underwent aortic valve replacement with the LDP. Mean valve-size was 25...
November 29, 2016: Journal of Cardiothoracic Surgery
https://www.readbyqxmd.com/read/27898433/transcatheter-aortic-valve-implantation-in-nonagenarians
#16
Adam Penkalla, Joerg Kempfert, Axel Unbehaun, Semih Buz, Thorsten Drews, Miralem Pasic, Volkmar Falk
OBJECTIVE: In this report, we assess the outcome of transcatheter aortic valve implantation (TAVI) in nonagenarians at our institution during a 6-year period. METHODS: Between April 2008 and July 2014, 40 patients with a mean ± SD age of 91.8 ± 2.3 years (range, 90-98 years) underwent TAVI. Thirty-three patients (82.5%) received transapical TAVI, and seven patients (17.5%) received transfemoral TAVI. Baseline characteristics were as follows: mean ± SD EuroSCORE II, 23...
November 28, 2016: Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
https://www.readbyqxmd.com/read/27897461/stability-development-of-immediately-loaded-hybrid-self-tapping-implants-inserted-in-the-posterior-maxilla-1-year-results-of-a-randomized-controlled-trial
#17
Vladimir S Todorovic, Miroslav Vasovic, Mia-Michaela Beetge, Andre W van Zyl, Vladimir Kokovic
The objective of the present study was to elucidate stability development of immediately loaded hybrid self-tapping implants inserted in the posterior maxilla. Forty-eight hybrid self-tapping implants with a chemically modified surface (∅4.1; length 8 mm) were inserted bilateral in the maxillary 1st and 2nd premolar and 1st molar sites of eight patients. In each patient, both sides of maxilla were randomly assigned to either immediate (IL) or early (EL) loading group. Implant stability was evaluated by means of resonance frequency analysis immediately after implant placement and after 1, 2, 3, 4, 5, 6, 12, 26 and 52 weeks...
November 29, 2016: Journal of Oral Implantology
https://www.readbyqxmd.com/read/27897030/influence-of-cardiac-motion-on-stent-lumen-visualization-in-third-generation-dual-source-ct-employing-a-pulsatile-heart-model
#18
Nils Petri, Tobias Gassenmaier, Thomas Allmendinger, Thomas Flohr, Wolfram Voelker, Thorsten A Bley
OBJECTIVE: To detect an in-stent restenosis an invasive coronary angiography is commonly performed. Due to the risk associated to this procedure, a non-invasive method to detect or exclude an in-stent restenosis is desirable. The purpose of this study was to evaluate the influence of cardiac motion on stent lumen visibility in a third-generation dual-source CT scanner (SOMATOM Force, Siemens Healthcare, Forchheim, Germany), employing a pulsatile heart model (CoroSim by Mecora). METHODS: Thirteen coronary stents with a diameter of 3...
November 29, 2016: British Journal of Radiology
https://www.readbyqxmd.com/read/27896843/impact-of-clinical-presentation-on-early-vascular-healing-after-bioresorbable-vascular-scaffold-implantation
#19
Moritz Baquet, Christoph Brenner, Maximilian Wenzler, Madeleine Eickhoff, Jochheim David, Stefan Brunner, Hans Theiss, Steffen Massberg, Giulio Guagliumi, Julinda Mehilli
BACKGROUND: Optimal strut coverage and early vascular healing are important factors to reduce the risk of stent thrombosis. Data on early vascular healing with the new bioresorbable vascular scaffolds (BVS) are lacking. Further, healing response after BVS implantation in different clinical presentation has not been fully investigated. METHODS AND RESULTS: We assessed with optical coherence tomography (OCT) the early vascular response to BVS implantation in 26 consecutive patients presenting with acute coronary syndrome (ACS) or stable angina (SA)...
November 28, 2016: Journal of Interventional Cardiology
https://www.readbyqxmd.com/read/27896007/in-vivo-monitoring-of-tissue-oxygen-saturation-in-deep-brain-structures-using-a-single-fiber-optical-system
#20
Linhui Yu, Ying Wu, Jeff F Dunn, Kartikeya Murari
We propose a single fiber optical system for monitoring tissue oxygen saturation (sO2) based on continuous-wave reflectance spectroscopy in the visible wavelengths. The system is designed for measurements in deep brain structures by stereotaxically implanting the 200 μm-core fiber probe into the tissue of interest. Monte Carlo (MC) simulations were used to estimate the measurement tissue volume between 0.02-0.03 mm(3). Experiments in an optical phantom indicated the system had a root mean squared error (RMSE) of 4...
November 1, 2016: Biomedical Optics Express
keyword
keyword
15933
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"