keyword
Keywords "Haemodynamic Monitoring" OR "...

"Haemodynamic Monitoring" OR "Hemodynamic Monitoring"

https://read.qxmd.com/read/38540989/evaluation-of-hemodynamic-changes-and-fluid-response-during-anesthesia-in-lumbar-disc-hernias-with-pleth-variability-index-pvi
#21
JOURNAL ARTICLE
Seda Sarihan, Tolga Koyuncu, Leyla Kazancioglu, Sule Batcik, Hizir Kazdal
The study aimed to assess the pleth variability index (PVI) in patients undergoing lumbar disc herniation surgery under general and spinal anesthesia, exploring its correlation with fluid responsiveness, position, and hemodynamic parameters. Methods: This prospective study included 88 ASA 1-2 patients, aged 18-65, undergoing 1-3 h elective lumbar disc herniation surgery. Patients in groups GA and SA were observed for demographic, operative, and hemodynamic parameters at specified time points. (3) Results: PVI values were comparable between the GA and SA groups...
February 25, 2024: Journal of Personalized Medicine
https://read.qxmd.com/read/38533144/successful-fluid-management-in-respiratory-failure-due-to-clazosentan-following-a-cerebral-aneurysm-clipping-a-case-report
#22
Hirotaka Kinoshita, Kodai Kato, Yuma Yamazaki, Eiji Hashiba, Kazuyoshi Hirota
Clazosentan, a potent selective endothelin receptor subtype A antagonist, has been demonstrated to be effective in preventing cerebral vasospasms after subarachnoid hemorrhage. We report the successful management of respiratory failure due to pulmonary edema associated with clazosentan, with a hemodynamic monitoring system. A 49-year-old Japanese man underwent emergency clipping for a right internal carotid-posterior communicating artery aneurysm. The surgery and general anesthesia for the rupture proceeded with no complications...
February 2024: Curēus
https://read.qxmd.com/read/38530625/acute-high-output-heart-failure-with-pulmonary-hypertension-and-severe-liver-injury-caused-by-amlodipine-poisoning-a-case-report
#23
JOURNAL ARTICLE
Chenlong Wang, Qingcheng Zhu, Dingyu Tan, Joseph Walline, Yachao Wang
Acute high-output heart failure (HOHF) with pulmonary hypertension and liver injury caused by amlodipine poisoning is very rare. We report a 52-year-old woman who suffered from severe shock after an overdose of amlodipine. Hemodynamic monitoring showed that while her left ventricular systolic function and cardiac output were elevated, her systemic vascular resistance decreased significantly. At the same time, the size of her right heart, her central venous pressure, and the oxygen saturation of her central venous circulation all increased abnormally...
March 26, 2024: Cardiovascular Toxicology
https://read.qxmd.com/read/38529464/can-currently-available-non-invasive-continuous-blood-pressure-monitors-replace-invasive-measurement-with-an-arterial-catheter
#24
REVIEW
Payton Gore, Hong Liu, Christian Bohringer
Deviations from normal blood pressure (BP) during general anesthesia have been clearly linked to several adverse outcomes. Measuring BP accurately is therefore critically important for producing excellent outcomes in health care. Normal BP does not necessarily guarantee adequate organ perfusion however and adverse events have occurred even when BP seemed adequate. Invasive blood pressure monitoring has recently evolved beyond merely measuring BP. Arterial line-derived pulse contour analysis is used now to assess both cardiac output and stroke volume variation as indices of adequate intravascular volume...
February 2024: Curēus
https://read.qxmd.com/read/38526192/echocardiography-in-the-neonatal-unit-current-status-and-future-prospects
#25
REVIEW
Yogen Singh
INTRODUCTION: Traditionally echocardiography was used by pediatric cardiologists to diagnose congenital heart defects in neonates. Formalized neonatal hemodynamic fellowships have been established where neonatologists acquire advanced echocardiographic skills to gain anatomical, physiological, and hemodynamic information in real time and utilize this information in making a timely and accurate physiology-based clinical decision. AREA COVERED: Differences between a comprehensive formal structural echocardiography, neonatologist performed targeted echocardiography and limited assessment on point-of-care-ultrasonography for specific indications have been covered...
March 25, 2024: Expert Review of Medical Devices
https://read.qxmd.com/read/38525306/usefulness-of-non-invasive-parameters-inferior-vena-cava-diameter-inferior-vena-cava-collapsibility-inferior-vena-cava-aortic-ratio-for-hemodynamic-monitoring-in-critically-ill-children-a-systematic-review
#26
REVIEW
Dzulfikar Djalil Lukman Hakim, Fina Meilyana, Stanza Uga Peryoga, Irma Arniawati, Elrika Anastasia Wijaya, Muhamad Rinaldhi Martiano
PURPOSE: Volume measurement in critically ill children can be conducted using invasive procedure such as Central Venous Pressure (CVP), or non-invasive procedure such as measurement of Inferior Vena Cava (IVC) indices using ultrasonography. However, their accuracy and efficacy are still under scrutiny. We aim to compare CVP and IVC indices as non-invasive parameters in assessing volume status in critically ill children. METHODS: We conducted a systematic review based on literature searching from four electronic databases which were PubMed, Cochrane, ScienceDirect, SpringerLink with keywords: "CENTRAL VENOUS PRESSURE", "INFERIOR VENA CAVA DIAMETER", "INFERIOR VENA CAVA COLLAPSIBILITY", "INFERIOR VENA CAVA AORTIC-RATIO", "VOLUME STATUS", "FLUID STATUS", "CRITICAL ILL", "CHILDREN", and "PEDIATRICS"...
2024: Medical Devices: Evidence and Research
https://read.qxmd.com/read/38524770/impact-of-goal-directed-hemodynamic-therapy-on-perioperative-outcomes-in-head-and-neck-free-flap-surgery-a-before-and-after-pilot-study
#27
JOURNAL ARTICLE
Justine Philteos, Stuart A McCluskey, Sophia Emerson, George Djaiani, David Goldstein, Sabri Soussi
BACKGROUND: Free flap reconstruction for head and neck cancer is associated with a high risk of perioperative complications. One of the modifiable risk factors associated with perioperative morbidity is intraoperative hypotension (IOH). The main aim of this pilot study is to determine if the intraoperative use of goal-directed hemodynamic therapy (GDHT) is associated with a reduction in the number of IOH events in this population. METHODS: A before-and-after study design...
March 2024: Health Science Reports
https://read.qxmd.com/read/38520314/echocardiographic-haemodynamic-monitoring-in-the-context-of-heartmate-3%C3%A2-therapy-a-systematic-review
#28
JOURNAL ARTICLE
Linus Ohlsson, Joanna-Maria Papageorgiou, Tino Ebbers, Meriam Åström Aneq, Éva Tamás, Hans Granfeldt
AIMS: While echocardiography remains essential within haemodynamic monitoring of durable mechanical circulatory support, previous echocardiographic guidelines are missing scientific evidence for the novel HeartMate 3™ (HM3) system. Accordingly, this review aims to summarize available echocardiographic evidence including HM3. METHODS AND RESULTS: This systematic review adhered to the PRISMA 2020 guidelines. Searches were conducted during August 2023 across PubMed, Embase, and Google Scholar using specific echocardiographic terms combined with system identifiers...
March 23, 2024: ESC Heart Failure
https://read.qxmd.com/read/38510955/paradoxical-pulmonary-artery-systolic-pressure-response-with-catheter-directed-therapies-for-pulmonary-embolism
#29
JOURNAL ARTICLE
Patrick Ho, Farouk Al-Chami, Mara Caroline, Eric Gnall, Joseph Bonn, Lee Greenspon
BACKGROUND: Early data on use of catheter-directed therapies (CDT) for treatment of Intermediate or High-Risk pulmonary embolism (PE) show improvement in pulmonary artery systolic pressures (PAsP) and RV/LV ratios. Occasionally a paradoxical rise in PAsP was observed with CDT utilizing ultrasound-assisted thrombolysis (USAT). It is unclear whether this pattern is seen with CDT utilizing mechanical aspiration. OBJECTIVES: To investigate and compare the changes in PAsP between those who underwent CDT with USAT to those with mechanical aspiration...
October 2023: American heart journal plus: cardiology research and practice
https://read.qxmd.com/read/38506945/intravenous-administration-of-ultrasound-contrast-to-critically-ill-pediatric-patients
#30
JOURNAL ARTICLE
Becky J Riggs, Santiago Martinez-Correa, Joseph Stern, Luis Octavio Tierradentro-Garcia, Sophie Haddad, Sudha Anupindi, Susan J Back, Kassa Darge, Misun Hwang
BACKGROUND: The off-label use of contrast-enhanced ultrasound has been increasingly used for pediatric patients. OBJECTIVE: The purpose of this retrospective study is to report any observed clinical changes associated with the intravenous (IV) administration of ultrasound contrast to critically ill neonates, infants, children, and adolescents. MATERIALS AND METHODS: All critically ill patients who had 1 or more contrast-enhanced ultrasound scans while being closely monitored in the neonatal, pediatric, or pediatric cardiac intensive care units were identified...
March 20, 2024: Pediatric Radiology
https://read.qxmd.com/read/38506816/peripheral-arterial-catheter-securement-and-catheter-survival-in-the-pediatric-intensive-care-unit
#31
JOURNAL ARTICLE
Mary S Pilarz, Sarah B Walker, Matthew J Rowland
BACKGROUND: Peripheral arterial catheters (PACs), and their associated complications, are common in the pediatric intensive care unit (PICU). Accidental catheter displacement and non-functional PACs are the most common complications, and this may be related to inadequate catheter securement. There is mixed guidance on the best way to secure PACs to prevent complications. The authors hypothesized that sutures would not be associated with a decreased risk of malfunction or accidental removal...
March 20, 2024: Journal of Vascular Access
https://read.qxmd.com/read/38500304/assessing-the-impact-of-haemodynamic-monitoring-with-cardiomems-on-heart-failure-patients-a-cost-benefit-analysis
#32
JOURNAL ARTICLE
Pau Codina, José Ángel Vicente Gómez, Guillem Hernández Guillamet, Laura Ricou Ríos, Andrea Carrete, Victoria Vilalta, Oriol Estrada, Jordi Ara, Josep Lupón, Antoni Bayés-Genís, Francesc López Seguí
AIMS: The objective of this study was to perform a cost-benefit analysis of the CardioMEMS HF System (Abbott Laboratories, Abbott Park, IL, USA) in a heart failure (HF) clinic in Spain by evaluating the real-time remote monitoring of pulmonary artery pressures, which has been shown to reduce HF-related hospitalizations and improve the quality of life for selected HF patients. Particularly, the study aimed to determine the value of CardioMEMS in Southern Europe, where healthcare costs are significantly lower and its effectiveness remains uncertain...
March 18, 2024: ESC Heart Failure
https://read.qxmd.com/read/38483559/consistency-of-data-reporting-in-fluid-responsiveness-studies-in-the-critically-ill-setting-the-codefire-consensus-from-the-cardiovascular-dynamic-section-of-the-european-society-of-intensive-care-medicine
#33
JOURNAL ARTICLE
Antonio Messina, Michelle S Chew, Daniele Poole, Lorenzo Calabrò, Daniel De Backer, Katia Donadello, Glenn Hernandez, Olfa Hamzaoui, Mathieu Jozwiak, Christopher Lai, Manu L N G Malbrain, Jihad Mallat, Sheyla Nainan Myatra, Laurent Muller, Gustavo Ospina-Tascon, Michael R Pinsky, Sebastian Preau, Bernd Saugel, Jean-Louis Teboul, Maurizio Cecconi, Xavier Monnet
PURPOSE: To provide consensus recommendations regarding hemodynamic data reporting in studies investigating fluid responsiveness and fluid challenge (FC) use in the intensive care unit (ICU). METHODS: The Executive Committee of the European Society of Intensive Care Medicine (ESICM) commissioned and supervised the project. A panel of 18 international experts and a methodologist identified main domains and items from a systematic literature, plus 2 ancillary domains...
March 14, 2024: Intensive Care Medicine
https://read.qxmd.com/read/38476069/the-correlation-between-carotid-artery-doppler-and-stroke-volume-during-central-blood-volume-loss-and-resuscitation
#34
JOURNAL ARTICLE
Isabel Kerrebijn, Sarah Atwi, Mai Elfarnawany, Andrew M Eibl, Joseph K Eibl, Jenna L Taylor, Chul Ho Kim, Bruce D Johnson, Jon-Émile S Kenny
BACKGROUND: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. METHODS: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory...
February 2024: Acute and critical care
https://read.qxmd.com/read/38475832/prehospital-invasive-arterial-blood-pressure-monitoring-in-critically-ill-patients-attended-by-a-uk-helicopter-emergency-medical-service-a-retrospective-observational-review-of-practice
#35
JOURNAL ARTICLE
Emma D Butterfield, James Price, Marco Bonsano, Kate Lachowycz, Zachary Starr, Christopher Edmunds, Jon Barratt, Rob Major, Paul Rees, Ed B G Barnard
BACKGROUND: Accurate haemodynamic monitoring in the prehospital setting is essential. Non-invasive blood pressure measurement is susceptible to vibration and motion artefact, especially at extremes of hypotension and hypertension: invasive arterial blood pressure (IABP) monitoring is a potential solution. This study describes the largest series to date of cases of IABP monitoring being initiated prehospital. METHODS: This retrospective observational study was conducted at East Anglian Air Ambulance (EAAA), a UK helicopter emergency medical service (HEMS)...
March 12, 2024: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
https://read.qxmd.com/read/38464864/validation-of-the-openwater-wearable-optical-system-cerebral-hemodynamic-monitoring-during-a-breath-hold-maneuver
#36
JOURNAL ARTICLE
Christopher G Favilla, Sarah Carter, Brad Hartl, Rebecca Gitlevich, Michael T Mullen, Arjun G Yodh, Wesley B Baker, Soren Konecky
SIGNIFICANCE: Bedside cerebral blood flow (CBF) monitoring has the potential to inform and improve care for acute neurologic diseases, but technical challenges limit the use of existing techniques in clinical practice. AIM: Here, we validate the Openwater optical system, a novel wearable headset that uses laser speckle contrast to monitor microvascular hemodynamics. APPROACH: We monitored 25 healthy adults with the Openwater system and concurrent transcranial Doppler (TCD) while performing a breath-hold maneuver to increase CBF...
January 2024: Neurophotonics
https://read.qxmd.com/read/38461034/hemodynamic-monitoring-in-the-cardiac-surgical-patient-comparison-of-three-arterial-catheters
#37
RANDOMIZED CONTROLLED TRIAL
Danny Bui, Geoffrey Hayward, Tzong Huei Chen, Patricia Apruzzese, Shyamal Asher, Matthew Maslow, Michelle Gorgone, Caroline Hunter, Devon Flaherty, Mark Kendall, Andrew Maslow
OBJECTIVE: Systemic systolic (SAP) and mean (MAP) arterial pressure monitoring is the cornerstone in hemodynamic management of the cardiac surgical patient, and the radial artery is the most common site of catheter placement. The present study compared 3 different arterial line procedures. It is hypothesized that a 20-G 12.7- cm catheter inserted into the radial artery will be equal to a 20-G 12.7- cm angiocath placed in the brachial artery, and superior to a 20-G 5.00 cm angiocath placed in the radial artery...
May 2024: Journal of Cardiothoracic and Vascular Anesthesia
https://read.qxmd.com/read/38459599/risk-factors-for-arterial-catheter-failure-and-complications-during-critical-care-hospitalisation-a-secondary-analysis-of-a-multisite-randomised-trial
#38
JOURNAL ARTICLE
Jessica A Schults, Emily R Young, Nicole Marsh, Emily Larsen, Amanda Corley, Robert S Ware, Marghie Murgo, Evan Alexandrou, Matthew McGrail, John Gowardman, Karina R Charles, Adrian Regli, Hideto Yasuda, Claire M Rickard
OBJECTIVES: Arterial catheters (ACs) are critical for haemodynamic monitoring and blood sampling but are prone to complications. We investigated the incidence and risk factors of AC failure. METHODS: Secondary analysis of a multi-centre randomised controlled trial (ACTRN 12610000505000). Analysis included a subset of adult intensive care unit patients with an AC. The primary outcome was all-cause device failure. Secondary outcomes were catheter associated bloodstream infection (CABSI), suspected CABSI, occlusion, thrombosis, accidental removal, pain, and line fracture...
March 8, 2024: Journal of Intensive Care
https://read.qxmd.com/read/38452387/influence-of-different-intraoperative-fluid-management-on-postoperative-outcome-after-abdominal-tumours-resection
#39
JOURNAL ARTICLE
Matej Jenko, Katarina Mencin, Vesna Novak-Jankovic, Alenka Spindler-Vesel
BACKGROUND: Intraoperative fluid management is a crucial aspect of cancer surgery, including colorectal surgery and pancreatoduodenectomy. The study tests if intraoperative multimodal monitoring reduces postoperative morbidity and duration of hospitalisation in patients undergoing major abdominal surgery treated by the same anaesthetic protocols with epidural analgesia. PATIENTS AND METHODS: A prospective study was conducted in 2 parallel groups. High-risk surgical patients undergoing major abdominal surgery were randomly selected in the control group (CG), where standard monitoring was applied (44 patients), and the protocol group (PG), where cerebral oxygenation and extended hemodynamic monitoring were used with the protocol for intraoperative interventions (44 patients)...
March 7, 2024: Radiology and Oncology
https://read.qxmd.com/read/38427062/evaluation-of-hemorrhagic-shock-and-fluid-resuscitation-in-pigs-using-handless-doppler-carotid-artery-ultrasound
#40
JOURNAL ARTICLE
Xiaoli Zhao, Wei Yuan, Shuo Wang, Junyuan Wu, Chunsheng Li
OBJECTIVE: This study aimed to utilize a hemorrhagic shock pig model to compare two hemodynamic monitoring methods, pulse index continuous cardiac output (PiCCO) and spectral carotid artery Doppler ultrasound (CDU). Additionally, we sought to explore the feasibility of employing CDU as a non-invasive hemodynamic monitoring tool in the context of hemorrhagic shock and fluid resuscitation. DESIGN: Animal experiments. SETTING AND SUBJECTS: Female pigs were selected, and hemorrhagic shock was induced by rapid bleeding through an arterial sheath...
March 1, 2024: European Journal of Trauma and Emergency Surgery: Official Publication of the European Trauma Society
keyword
keyword
158309
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.