JOURNAL ARTICLE
Ying Zhang, Zhihui Wen, Michael P Washburn, Laurence Florens
Several methods to obtain low-ppm mass accuracy have been described. In particular, online or offline lock mass approaches can use background ions, produced by electrospray under ambient conditions, as calibrants. However, background ions such as protonated and ammoniated polydimethylcyclosiloxane ions have relatively weak and fluctuating intensity. To address this issue, we implemented dynamic offline lock mass (DOLM). Within every MS1 survey spectrum, DOLM dynamically selected the strongest n background ions for statistical treatments and m/z recalibration...
December 15, 2011: Analytical Chemistry
https://read.qxmd.com/read/21953191/software-lock-mass-by-two-dimensional-minimization-of-peptide-mass-errors
#22
JOURNAL ARTICLE
Jürgen Cox, Annette Michalski, Matthias Mann
Mass accuracy is a key parameter in proteomic experiments, improving specificity, and success rates of peptide identification. Advances in instrumentation now make it possible to routinely obtain high resolution data in proteomic experiments. To compensate for drifts in instrument calibration, a compound of known mass is often employed. This 'lock mass' provides an internal mass standard in every spectrum. Here we take advantage of the complexity of typical peptide mixtures in proteomics to eliminate the requirement for a physical lock mass...
August 2011: Journal of the American Society for Mass Spectrometry
https://read.qxmd.com/read/21461040/ultra-fast-searching-assists-in-evaluating-sub-ppm-mass-accuracy-enhancement-in-u-hplc-orbitrap-ms-data
#23
JOURNAL ARTICLE
Arjen Lommen, Arjen Gerssen, J Efraim Oosterink, Harrie J Kools, Ainhoa Ruiz-Aracama, Ruud J B Peters, Hans G J Mol
A strategy, detailed methodology description and software are given with which the mass accuracy of U-HPLC-Orbitrap data (resolving power 50,000 FWHM) can be enhanced by an order of magnitude to sub-ppm levels. After mass accuracy enhancement all 211 reference masses have mass errors within 0.5 ppm; only 14 of these are outside the 0.2 ppm error margin. Further demonstration of mass accuracy enhancement is shown on a pre-concentrated urine sample in which evidence for 89 (342 ions) potential hydroxylated and glucuronated DHEA-metabolites is found...
March 2011: Metabolomics: Official Journal of the Metabolomic Society
https://read.qxmd.com/read/21192031/building-an-empirical-mass-spectra-library-for-screening-of-organic-pollutants-by-ultra-high-pressure-liquid-chromatography-hybrid-quadrupole-time-of-flight-mass-spectrometry
#24
JOURNAL ARTICLE
Ramón Díaz, María Ibáñez, Juan V Sancho, Félix Hernández
Hybrid quadrupole time-of-flight mass spectrometry (QTOF MS) has gained wide acceptance in many fields of chemistry, for example, proteomics, metabolomics and small molecule analysis. This has been due to the numerous technological advances made to this mass analyser in recent years. In the environmental field, the instrument has proven to be one of the most powerful approaches for the screening of organic pollutants in different matrices due to its high sensitivity in full acquisition mode and mass accuracy measurements...
January 30, 2011: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/21133379/24-hour-lock-mass-protection
#25
JOURNAL ARTICLE
Kimberly A Lee, Chris Farnsworth, Wen Yu, Leo E Bonilla
The positive role and application of highly accurate mass measurements in proteomics is well documented. The new generation of hybrid FTMS and Q-TOF instruments, including the LTQ-Orbitrap (OT), is remarkable in their ability to routinely produce single-digit to subppm statistical mass accuracy while maintaining high analytical sensitivity. The use of mass calibrants (lock masses) to reduce the systematic error of mass-to-charge measurements has also been reported and, in some cases, incorporated in the instrument control software by the instrument manufacturers...
February 4, 2011: Journal of Proteome Research
https://read.qxmd.com/read/20065514/multi-track-single-and-dual-channel-plastic-microchips-for-electrospray-mass-spectrometry
#26
JOURNAL ARTICLE
Luc Alexis Leuthold, Frédéric Reymond, Joël S Rossier, Emmanuel Varesio, Gérard Hopfgartner
Disposable plastic electrospray chips are particularly attractive for the automated analysis of organic compounds and organometallic compounds. Automated multi-track chip-based infusion electrospray mass spectrometry of low molecular weight compounds using an eight-channel plastic chip is presented. For that purpose, the commercial interface of a triple quadrupole linear ion trap was modified. A dual-channel plastic microchip, where two physically separated channels arrive very close to each other at the chip tip, was used to perform lock-mass accurate mass measurements on a quadrupole-time-of-flight instrument...
2010: European Journal of Mass Spectrometry
https://read.qxmd.com/read/17605142/methodical-approach-for-the-use-of-gc-tof-ms-for-screening-and-confirmation-of-organic-pollutants-in-environmental-water
#27
JOURNAL ARTICLE
Tania Portolés, Elena Pitarch, Francisco J López, Juan V Sancho, Félix Hernández
The potential of gas chromatography coupled to time-of-flight mass spectrometry (GC-TOF MS) for the screening of organic pollutants in water was explored. After a conventional SPE step with C(18) cartridges, the comparison of spectra with available libraries together with an evaluation of the mass accuracy was the first approach used for the screening and confirmation of target analytes. However, at low analyte concentrations (i.e. below 0.1 microg/l), this procedure was not feasible and the use of the application manager TargetLynx was evaluated...
September 2007: Journal of Mass Spectrometry: JMS
https://read.qxmd.com/read/17073410/polarity-switching-accurate-mass-measurement-of-pharmaceutical-samples-using-desorption-electrospray-ionization-and-a-dual-ion-source-interfaced-to-an-orthogonal-acceleration-time-of-flight-mass-spectrometer
#28
JOURNAL ARTICLE
Jonathan P Williams, Richard Lock, Vibhuti J Patel, James H Scrivens
A novel approach for the rapid, accurate mass analysis of pharmaceutical solid, liquid, and cream formulations using desorption electrospray ionization (DESI) is described. The method is based on polarity switching and real-time accurate mass measurement in an orthogonal acceleration time-of-flight mass spectrometer fitted with a dual-inlet electrospray ion source. Infusion of a reference compound into one inlet provides a single-point "lock mass" for accurate mass measurement. The other inlet sprays solvent at the sample being investigated using DESI...
November 1, 2006: Analytical Chemistry
https://read.qxmd.com/read/16759662/multi-residue-analysis-of-pharmaceuticals-in-wastewater-by-ultra-performance-liquid-chromatography-quadrupole-time-of-flight-mass-spectrometry
#29
JOURNAL ARTICLE
Mira Petrovic, Meritxell Gros, Damia Barcelo
In this work, a new multi-residue method using ultra-performance liquid chromatography (UPLC) quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was developed for screening and confirmation of 29 pharmaceutical compounds belonging to different therapeutical classes: analgesics and antiinflammatories, lipid regulating agents cholesterol lowering statin agents, psychiatric drugs, anti ulcer agents, histamine H2 receptor antagonist, antibiotics and beta-blockers. UPLC uses columns packed with 1.7 microm particles and enables elution of sample components in much narrower, more concentrated bands, resulting in better chromatographic resolution and increased peak height...
August 18, 2006: Journal of Chromatography. A
https://read.qxmd.com/read/16478717/top-down-protein-sequencing-and-ms3-on-a-hybrid-linear-quadrupole-ion-trap-orbitrap-mass-spectrometer
#30
JOURNAL ARTICLE
Boris Macek, Leonie F Waanders, Jesper V Olsen, Matthias Mann
Top-down proteomics, the analysis of intact proteins (instead of first digesting them to peptides), has the potential to become a powerful tool for mass spectrometric protein characterization. Requirements for extremely high mass resolution, accuracy, and ability to efficiently fragment large ions have often limited top-down analyses to custom built FT-ICR mass analyzers. Here we explore the hybrid linear ion trap (LTQ)-Orbitrap, a novel, high performance, and compact mass spectrometric analyzer, for top-down proteomics...
May 2006: Molecular & Cellular Proteomics: MCP
https://read.qxmd.com/read/16249172/parts-per-million-mass-accuracy-on-an-orbitrap-mass-spectrometer-via-lock-mass-injection-into-a-c-trap
#31
JOURNAL ARTICLE
Jesper V Olsen, Lyris M F de Godoy, Guoqing Li, Boris Macek, Peter Mortensen, Reinhold Pesch, Alexander Makarov, Oliver Lange, Stevan Horning, Matthias Mann
Mass accuracy is a key parameter of mass spectrometric performance. TOF instruments can reach low parts per million, and FT-ICR instruments are capable of even greater accuracy provided ion numbers are well controlled. Here we demonstrate sub-ppm mass accuracy on a linear ion trap coupled via a radio frequency-only storage trap (C-trap) to the orbitrap mass spectrometer (LTQ Orbitrap). Prior to acquisition of a spectrum, a background ion originating from ambient air is first transferred to the C-trap. Ions forming the MS or MS(n) spectrum are then added to this species, and all ions are injected into the orbitrap for analysis...
December 2005: Molecular & Cellular Proteomics: MCP
https://read.qxmd.com/read/16041729/site-specific-detection-of-s-nitrosylated-pkb-alpha-akt1-from-rat-soleus-muscle-using-caplc-q-tof-micro-mass-spectrometry
#32
JOURNAL ARTICLE
Xiao-Ming Lu, Mary Lu, Ronald G Tompkins, Alan J Fischman
Protein Kinase Balpha(PKBalpha, or Akt1) is believed to play a crucial role in programmed cell death, cancer progression and the insulin-signaling cascade. The protein is activated by phosphorylation at multiple sites and subsequently phosphorylates and activates eNOS. Free cysteine residues of the protein may capture reactive, endogenously produced nitric oxide (NO) as S-nitrosothiols. Site-specific detection of S-nitrosylated cysteine residues, usually at low stoichiometry, has been a major challenge in proteomic research largely due to the lack of mass marker for S-nitrosothiols that are very labile under physiologic conditions...
September 2005: Journal of Mass Spectrometry: JMS
https://read.qxmd.com/read/15915450/use-of-a-five-channel-multiplexed-electrospray-quadrupole-time-of-flight-hybrid-mass-spectrometer-for-metabolite-identification
#33
JOURNAL ARTICLE
Laurent Leclercq, Claude Delatour, Ilse Hoes, Françoise Brunelle, Xavier Labrique, José Castro-Perez
Metabolism data provided with reduced cycle time has become of increasing importance for the early evaluation of DMPK properties of drugs in discovery. In this regard, quadrupole time-of-flight hybrid mass spectrometers (Q-TOF) can provide very reliable metabolite identification via accurate mass measurement of ions and the consequent access to the elemental composition of the metabolite. However, due to their cost, they are often used for drug metabolism studies on later stage drug candidates or to address challenging metabolism questions...
2005: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/15853365/antioxidants-in-raspberry-on-line-analysis-links-antioxidant-activity-to-a-diversity-of-individual-metabolites
#34
COMPARATIVE STUDY
Jules Beekwilder, Harry Jonker, Patrick Meesters, Robert D Hall, Ingrid M van der Meer, C H Ric de Vos
The presence of antioxidant compounds can be considered as a quality parameter for edible fruit. In this paper, we studied the antioxidant compounds in raspberry (Rubus idaeus) fruits by high-performance liquid chromatography (HPLC) coupled to an on-line postcolumn antioxidant detection system. Both developmental and genetic factors were assessed by comparing fruits from a single cultivar of different ripening stages and by comparing ripe fruits of 14 raspberry cultivars, respectively. The HPLC-separated antioxidant compounds were identified using HPLC-photodiode array coupled to mass spectrometry (quadrupole time-of-flight tandem mass spectrometry), using a reference lock mass for determining accurate masses...
May 4, 2005: Journal of Agricultural and Food Chemistry
https://read.qxmd.com/read/15174182/a-modified-internal-lock-mass-method-for-calibration-of-the-product-ions-derived-from-sustained-off-resonance-irradiation-collision-induced-dissociation-using-a-fourier-transform-mass-spectrometer
#35
JOURNAL ARTICLE
Lifang Duan, T-W Dominic Chan
A modified internal lock-mass calibration method is introduced for improving the mass measurement accuracy of the product ion spectra derived from sustained off-resonance irradiation collision-induced dissociation (SORI-CID) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry. This method involves an initial external calibration of the Fourier transform mass spectrometer to obtain the initial A- and B-terms for the equation (f(i) = A/(m/z)(i) + B). The A-term is adjusted by using an empirical relationship between the up-shift of the A-term and the pulse-gas duration, whereas the B-term is adjusted by using the mass of the unfragmented precursor ion from the SORI-CID mass spectrum of the unknown sample as internal lock-mass...
2004: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/12820209/exact-mass-measurement-of-product-ions-for-the-structural-confirmation-and-identification-of-unknown-compounds-using-a-quadrupole-time-of-flight-spectrometer-a-simplified-approach-using-combined-tandem-mass-spectrometric-functions
#36
JOURNAL ARTICLE
Karine Clauwaert, Sofie Vande Casteele, Bart Sinnaeve, Dieter Deforce, Willy Lambert, Carlos Van Peteghem, Jan Van Bocxlaer
This article describes a simple method to perform lock mass corrected accurate mass measurements in tandem mass spectrometry (MS/MS) with a quadrupole time-of-flight (Q-TOF) mass spectrometer. The experimental approach consists of using the protonated molecule of a known compound, which is measured in a MS/MS function using low collision energy (no fragmentation), as mass calibrator. The unknown compound is acquired in MS/MS mode albeit using high collision energy. After the acquisition, the two MS/MS spectra of unknown and mass calibrator are combined, and the fragments of the unknown are lock mass corrected by using the protonated molecule of the mass calibrator...
2003: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/12820201/flow-injection-of-the-lock-mass-standard-for-accurate-mass-measurement-in-electrospray-ionization-time-of-flight-mass-spectrometry-coupled-with-liquid-chromatography
#37
JOURNAL ARTICLE
Laurence Charles
A method of flow injection of the lock mass for accurate mass measurement using electrospray ionization time-of-flight mass spectrometry is described. The reference compound is introduced in the chromatographic effluent via a six-port valve placed post-column, prior to the split connector. Flow injection is performed in such a way that the reference elution peak is superimposed in the total ion current and partially overlaps that of the investigated analyte, allowing independent ionization of the two compounds and thus accurate mass measurement with no ion suppression effects...
2003: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/11544596/screening-for-anabolic-steroids-and-related-compounds-in-illegal-cocktails-by-liquid-chromatography-time-of-flight-mass-spectrometry-and-liquid-chromatography-quadrupole-time-of-flight-tandem-mass-spectrometry-with-accurate-mass-measurement
#38
JOURNAL ARTICLE
M W Nielen, J P Vissers, R E Fuchs, J W van Velde, A Lommen
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer...
2001: Rapid Communications in Mass Spectrometry: RCM
https://read.qxmd.com/read/11048845/environmental-screening-of-acidic-compounds-based-on-capillary-zone-electrophoresis-laser-induced-fluorescence-detection-with-identification-by-gas-chromatography-mass-spectrometry-and-gas-chromatography-high-resolution-mass-spectrometry
#39
JOURNAL ARTICLE
W C Brumley, A H Grange, V Kelliher, D B Patterson, A Montcalm, J Glassman, J W Farley
This paper describes the application of capillary zone electrophoresis/laser-induced fluorescence detection (CZE/LIF) to the discovery of acidic compounds in environmental matrixes or the screening of extracts for acidic components. Published studies indicate that coal-derived materials contain a significant fraction of acidic compounds relative to materials derived from petroleum and shales. Such compounds may be useful as marker compounds for site assessment and source apportionment issues, and their identification may be important in toxicological and other health issues...
September 2000: Journal of AOAC International
https://read.qxmd.com/read/10749489/liquid-chromatography-electrospray-time-of-flight-mass-spectrometry-for-on-line-accurate-mass-determination-and-identification-of-cyclodepsipeptides-in-a-crude-extract-of-the-fungus-metarrhizium-anisopliae
#40
JOURNAL ARTICLE
O Potterat, K Wagner, H Haag
Electrospray ionisation time-of-flight mass spectrometry (ESI-TOF-MS) has been used for the detection and identification of destruxins (cyclodepsipeptides) in a crude extract of the fungus Metarrhizium anisopliae. HPLC-MS analyses were performed with a post-column addition of erythromycin as a reference compound (lock mass procedure). Seven destruxin derivatives could be identified on-line from their accurate masses (deviation from calculated values <5.5 ppm) through elemental composition calculations. As a highly sensitive and accurate method, ESI-TOF-MS proved to be very powerful for the analysis and dereplication of natural products in complex mixtures...
March 3, 2000: Journal of Chromatography. A
keyword
keyword
13019
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.