keyword
https://read.qxmd.com/read/36976933/efficacy-and-safety-of-ut-dsaek-combined-with-carlevale-s-sutureless-scleral-fixation-iol
#21
JOURNAL ARTICLE
Agostino S Vaiano, Antonio Greco, Andrea Greco, Maria E Toro, Marco G Leto, Giacomo Savini
PURPOSE: To evaluate a novel surgical combination of ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) and sutureless scleral fixation for Carlevale intraocular lens (SSF-Carlevale IOL) implantation to manage corneal endothelial decompensation when there is a concomitant need for secondary IOL fixation. METHODS: Clinical data collected from 10 eyes of 9 patients with bullous keratopathy (BK) who underwent combined UT-DSAEK and SSF-Carlevale IOL implantation in a single procedure were retrospectively analyzed...
March 28, 2023: European Journal of Ophthalmology
https://read.qxmd.com/read/36913536/predictability-of-the-vault-after-implantable-collamer-lens-implantation-using-oct-and-artificial-intelligence-in-caucasian-eyes
#22
JOURNAL ARTICLE
Andrea Russo, Ottavia Filini, DMath Giacomo Savini, Giulia Festa, Francesco Morescalchi, Alessandro Boldini, Francesco Semeraro
PURPOSE: To compare the predicted vault using machine learning with the achieved vault using the online manufacturer's nomogram in patients undergoing posterior chamber implantation with an implantable collamer lens (ICL). SETTING: Centro Oculistico Bresciano, Brescia, Italy and I.R.C.C.S. - Bietti Foundation, Rome, Italy. DESIGN: Retrospective multicenter comparison study. METHODS: This study included 561 eyes from 300 consecutive patients who underwent ICL placement surgery...
March 13, 2023: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/36892239/accuracy-of-nine-formulas-to-calculate-the-powers-of-an-extended-depth-of-focus-iol-using-two-ss-oct-biometers
#23
JOURNAL ARTICLE
Sohee Jeon, Leonardo Taroni, Enrico Lupardi, Kenneth J Hoffer, Luigi Fontana, Domenico Schiano-Lomoriello, Hyunggoo Kwon, Giacomo Savini
PURPOSE: To evaluate the accuracy of nine formulas to calculate the power of a new extended depth-of-focus intraocular lens (EDOF IOL), the AcrySof IQ Vivity (Alcon Laboratories, Inc), using measurements from two optical biometers, the IOLMaster 700 (Carl Zeiss Meditec AG) and Anterion (Heidelberg Engineering GmbH). METHODS: After constant optimization, the accuracy of these formulas was analyzed in 101 eyes: Barrett Universal II, EVO 2.0, Haigis, Hoffer Q, Holladay 1, Kane, Olsen, RBF 3...
March 2023: Journal of Refractive Surgery
https://read.qxmd.com/read/36867472/method-to-analyze-the-refractive-outcomes-of-online-intraocular-lens-power-formulas
#24
LETTER
Enrico Lupardi, Kenneth J Hoffer, Luigi Fontana, Giacomo Savini
No abstract text is available yet for this article.
March 1, 2023: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/36862309/corneal-higher-order-aberrations-measurements-precision-of-sd-oct-placido-topography-and-comparison-with-a-scheimpflug-placido-topography-in-eyes-after-small-incision-lenticule-extraction
#25
JOURNAL ARTICLE
Rui Ning, Xiaomin Huang, Yili Jin, Chak Seng Lei, Xindi Ma, Shuoyu Xu, Jinxuan Xiahou, Giacomo Savini, Domenico Schiano-Lomoriello, Xiaoying Wang, Xingtao Zhou, Jinhai Huang
INTRODUCTION: The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device). METHODS: A total of 56 eyes (56 patients) were included in this prospective study...
March 2, 2023: Ophthalmology and Therapy
https://read.qxmd.com/read/36829259/agreement-between-a-new-optical-low-coherence-reflectometry-biometer-and-an-anterior-segment-optical-coherence-tomographer
#26
JOURNAL ARTICLE
Yiran Wang, Ting Wan, Luze Liu, Yuyuan Xue, Xinyao Chen, Giacomo Savini, Domenico Schiano-Lomoriello, Xingtao Zhou, Jinjin Yu, Jinhai Huang
BACKGROUND: To assess agreement of measurements between a new optical low coherence reflectometry (OLCR) biometer (SW-9000, Suoer, Tianjin, China) and a spectral-domain optical coherence tomographer (SD-OCT)/Placido topographer (MS-39, CSO, Florence, Italy) in healthy subjects. METHODS: A total of 66 right eyes from 66 healthy subjects were enrolled in this prospective study. Three consecutive measurements were randomly obtained with both devices by the same experienced operator to assess agreement...
February 25, 2023: Eye and Vision (London, England)
https://read.qxmd.com/read/36729423/comparison-of-the-new-hoffer-qst-with-4-modern-accurate-formulas
#27
COMPARATIVE STUDY
Leonardo Taroni, Kenneth J Hoffer, Marco Pellegrini, Enrico Lupardi, Giacomo Savini
PURPOSE: To investigate the new Hoffer QST (Savini/Taroni) formula (HQST) and compare it with the original Hoffer Q (HQ) and 4 latest generation formulas. SETTING: I.R.C.C.S.-G.B. Bietti Foundation, Rome, Italy. DESIGN: Retrospective case series. METHODS: Refractive outcomes of the HQST, Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) 2.0, HQ, Kane, and Radial Basis Function (RBF) 3.0 formulas were compared...
April 1, 2023: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/36593481/comprehensive-comparisons-of-ocular-biometry-a%C3%A2-network-based-big-data%C3%A2-analysis
#28
JOURNAL ARTICLE
Jinjin Yu, Daizong Wen, Jing Zhao, Yiran Wang, Ke Feng, Ting Wan, Giacomo Savini, Colm McAlinden, Xuanqiao Lin, Lingling Niu, Sisi Chen, Qingyi Gao, Rui Ning, Yili Jin, Xingtao Zhou, Jinhai Huang
PURPOSE: To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data. METHODS: PubMed, Embase, the Cochrane Library and the US trial registry ( www. CLINICALTRIAL: gov ) were used to systematically search trials published up to October 22nd, 2020. We included comparative studies reporting the following parameters measured by at least two devices: axial length (AL), flattest meridian keratometry (Kf), steepest meridian keratometry (Ks), mean keratometry (Km), astigmatism (AST), astigmatism vectors J0 and J45 , anterior chamber depth (ACD), aqueous depth (AQD), central corneal thickness (CCT), corneal diameter (CD) and lens thickness (LT)...
December 10, 2022: Eye and Vision (London, England)
https://read.qxmd.com/read/36252676/optical-biometry-and-iol-calculation-in-a-commercially-available-optical-coherence-tomography-device-and-comparison-with-pentacam-axl
#29
JOURNAL ARTICLE
Piotr Kanclerz, Kenneth J Hoffer, Natasza Bazylczyk, Xiaogang Wang, Giacomo Savini
PURPOSE: Optical devices are the gold standard for ocular biometry, however, they are unable to obtain high quality optical coherence tomography (OCT) images. The current study aimed to evaluate ocular measurements and intraocular lens (IOL) calculation employed in an anterior/posterior segment OCT device and compare the results to a validated biometer. DESIGN: Prospective evaluation of a diagnostic tool. METHODS: This study enrolled healthy subjects at the Hygeia Clinic, Gdańsk, Poland, between October 2021 and November 2021...
October 14, 2022: American Journal of Ophthalmology
https://read.qxmd.com/read/36100171/reply-comment-on-iol-power-calculation-with-ray-tracing-based-on-anterior-segment-oct-and-adjusted-axial-length-after-myopic-excimer-laser-surgery
#30
JOURNAL ARTICLE
Giacomo Savini, Kenneth J Hoffer, Filomena Ribeiro, Joao Mendañha Dias, Catarina Coutinho, Piero Barboni, Domenico Schiano-Lomoriello
No abstract text is available yet for this article.
September 6, 2022: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/36026703/repeatability-of-new-optical-biometer-and-agreement-with-two-validated-optical-biometers-all-based-on-swept-source-optical-coherence-tomography
#31
JOURNAL ARTICLE
Alice Galzignato, Enrico Lupardi, Kenneth J Hoffer, Piero Barboni, Domenico Schiano-Lomoriello, Giacomo Savini
PURPOSE: to evaluate the repeatability of the measurements provided by a new optical biometer (EyeStar 900, Haag-Streit) based on swept-source optical coherence tomography (SS- OCT) and their agreement with the measurements given by two validated biometers based on the same technology, the IOLMaster 700 (Carl Zeiss Meditec) and Argos (Movu). SETTING: IRCCS G.B. Bietti Foundation, Rome, Italy. DESIGN: Prospective evaluation of diagnostic test...
August 23, 2022: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/35889993/detection-of-brucella-abortus-vaccine-strain-rb51-in-water-buffalo-bubalus-bubalis-milk
#32
JOURNAL ARTICLE
Daniela Averaimo, Fabrizio De Massis, Giovanni Savini, Giuliano Garofolo, Flavio Sacchini, Anna Abass, Manuela Tittarelli, Giacomo Migliorati, Antonio Petrini
The isolation of B. abortus RB51 vaccine strain from a milk sample in a water buffalo farm in southern Italy emphasizes the risk to public health of consuming contaminated milk or milk products following illegal vaccination.
June 30, 2022: Pathogens
https://read.qxmd.com/read/35858193/iol-power-calculation-in-eyes-undergoing-combined-descemet-membrane-endothelial-keratoplasty-and-cataract-surgery
#33
JOURNAL ARTICLE
Karl Anders Knutsson, Giacomo Savini, Kenneth J Hoffer, Enrico Lupardi, Federico Bertuzzi, Leonardo Taroni, Domenico Schiano-Lomoriello, Giorgio Paganoni, Paolo Rama
PURPOSE: To assess the accuracy of different corneal powers for intraocular (IOL) power calculation in combined Descemet membrane endothelial keratoplasty (DMEK) and cataract surgery and investigate whether preoperative parameters correlate to the prediction error (PE). METHODS: This prospective case series involved patients with Fuchs endothelial dystrophy receiving combined DMEK and cataract surgery. Preoperatively, patients underwent optical biometry and anterior segment OCT (AS-OCT)...
July 2022: Journal of Refractive Surgery
https://read.qxmd.com/read/35786808/reply-comparison-of-different-methods-to-calculate-the-axial-length-measured-by-optical-biometry
#34
LETTER
Giacomo Savini, Kenneth J Hoffer, Laura Carballo, Leonardo Taroni, Domenico Schiano-Lomoriello
No abstract text is available yet for this article.
August 1, 2022: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/35665335/agreement-between-predicted-and-actual-measured-ablation-depth-after-fs-lasik-using-different-rotating-scheimpflug-cameras-and-oct
#35
JOURNAL ARTICLE
Hao Chen, Ziqian Wang, Kunke Li, Yiran Wang, Xin Li, Lan Du, Meimin Lin, Giacomo Savini, Qinmei Wang, Ayong Yu, Sisi Chen
Purpose: To compare the predicted ablation depth (AD) with the postoperatively measured corneal ablation depth (postop-AD) at central, paracentral, and midperipheral locations using two rotating Scheimpflug analyzers and a Fourier-domain optical coherence tomographer in eyes that underwent femtosecond laser-assisted LASIK (FS-LASIK). Methods: The values of corneal thickness were measured preoperatively and postoperatively at one and three months. The difference between preoperative and postoperative was defined as postop-AD...
2022: Frontiers in Medicine
https://read.qxmd.com/read/35636310/epidemiological-and-genomic-findings-of-the-first-documented-italian-outbreak-of-sars-cov-2-alpha-variant-of-concern
#36
JOURNAL ARTICLE
Laura Amato, Luca Candeloro, Arturo Di Girolamo, Lara Savini, Ilaria Puglia, Maurilia Marcacci, Marialuigia Caporale, Iolanda Mangone, Cesare Cammà, Annamaria Conte, Giuseppe Torzi, Adamo Mancinelli, Francesca Di Giallonardo, Alessio Lorusso, Giacomo Migliorati, Thomas Schael, Nicola D'Alterio, Paolo Calistri
From 24 December 2020 to 8 February 2021, 163 cases of SARS-CoV-2 Alpha variant of concern (VOC) were identified in Chieti province, Abruzzo region. Epidemiological data allowed the identification of 14 epi-clusters. With one exception, all the epi-clusters were linked to the town of Guardiagrele: 149 contacts formed the network, two-thirds of which were referred to the family/friends context. Real data were then used to estimate transmission parameters. According to our method, the calculated Re(t) was higher than 2 before the 12 December 2020...
May 13, 2022: Epidemics
https://read.qxmd.com/read/35616506/corneal-diameter-measurements-by-3-optical-biometers-and-their-effect-on-phakic-intraocular-lens-sizing
#37
JOURNAL ARTICLE
Giacomo Savini, Enrico Lupardi, Kenneth J Hoffer, Jaime Aramberri, Domenico Schiano-Lomoriello
PURPOSE: To compare phakic lens size calculations based on corneal diameter (CD) measurements by 3 instruments. SETTING: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. DESIGN: Retrospective interventional case series. METHODS: 54 eyes (29 patients) with the Implantable Collamer Lens (ICL, STAAR Surgical) were enrolled. Preoperatively, CD was measured with the Aladdin (Topcon EU), IOLMaster 700 (Carl Zeiss) and Pentacam AXL Wave (Oculus)...
May 26, 2022: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/35121684/intraocular-lens-power-calculation-with-ray-tracing-based-on-as-oct-and-adjusted-axial-length-after-myopic-excimer-laser-surgery
#38
JOURNAL ARTICLE
Giacomo Savini, Kenneth J Hoffer, Filomena J Ribeiro, Joao Mendanha Dias, Catarina P Coutinho, Piero Barboni, Domenico Schiano-Lomoriello
PURPOSE: To report the results of intraocular lens (IOL) power calculation by ray tracing in eyes with previous myopic excimer laser surgery. SETTING: G.B. Bietti Foundation I.R.C.C.S., Rome, Italy. DESIGN: Retrospective interventional case series. METHODS: A series of consecutive patients undergoing phacoemulsification and IOL implantation after myopic excimer laser was investigated. IOL power was calculated using ray-tracing software available on the anterior segment optical coherence tomographer MS-39...
August 1, 2022: Journal of Cataract and Refractive Surgery
https://read.qxmd.com/read/34914555/comparison-of-corneal-power-calculation-by-standard-keratometry-and-total-keratometry-in-eyes-with-previous-myopic-fs-lasik
#39
JOURNAL ARTICLE
Enrico Lupardi, Leonardo Taroni, Kenneth J Hoffer, Domenico Schiano-Lomoriello, Giacomo Savini
PURPOSE: To compare the accuracy of Total Keratometry (TK) and standard keratometry (K) with the IOLMaster 700 (Carl Zeiss Meditec) in evaluating the corneal refractive change in eyes with previous myopic femtosecond laser-assisted LASIK (FS-LASIK). METHODS: A series of consecutive patients who had undergone myopic FS-LASIK was prospectively enrolled. The refractive change in spherical equivalent (ΔSE) was defined as the difference between the preoperative target correction entered into the laser software and the postoperative cycloplegic refraction...
December 2021: Journal of Refractive Surgery
https://read.qxmd.com/read/34759175/immersion-ultrasound-biometry-vs-optical-biometry
#40
JOURNAL ARTICLE
David L Cooke, Rhonda Waldron, Giacomo Savini, Kamran M Riaz, Leonardo Taroni, David A Murphy, Fabio Guaraldi
PurposeAxial length (AL) measurements are routinely obtained by optical biometry (OB). Sometimes, however, immersion ultrasound (IUS) is required. Due to the small discrepancies between the two methods, it is unknown if optimized constants for OB are accurate for IUS. We compared these techniques and found how to use OB constants for eyes with AL by IUS.SettingMulticenter studyDesignRetrospective observational case seriesMethodsAgreement between OB and IUS ALs was investigated in 4 subsets. Also, in a test database, the prediction error for IUS AL was assessed with four methods: 1) data-optimized constants; 2) User group for Laser Interference Biometry (ULIB) constants with IUS biometry; 3) with recalibrated AL; and 4) ULIB A-constant-0...
November 9, 2021: Journal of Cataract and Refractive Surgery
keyword
keyword
12537
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.