keyword
MENU ▼
Read by QxMD icon Read
search

Giacomo savini

keyword
https://www.readbyqxmd.com/read/28991853/simulated-keratometry-versus-total-corneal-power-by-ray-tracing-a-comparison-in-prediction-accuracy-of-intraocular-lens-power
#1
Giacomo Savini, Kenneth J Hoffer, Domenico Schiano Lomoriello, Pietro Ducoli
PURPOSE: To investigate the relationship between corneal powers measured by simulated keratometry (Sim-K) and ray tracing and understand whether their difference influences intraocular lens (IOL) power calculation. METHODS: In a first sample of healthy eyes, corneal curvature was measured using a rotating Scheimpflug camera (Sirius, CSO). Sim-K was obtained from anterior corneal curvature using the 1.3375 keratometric index. Ray tracing was performed through both corneal surfaces to calculate the total corneal power (TCP)...
November 2017: Cornea
https://www.readbyqxmd.com/read/28991609/optimized-keratometry-and-total-corneal-astigmatism-for-toric-intraocular-lens-calculation
#2
Giacomo Savini, Kristian Næser, Domenico Schiano-Lomoriello, Pietro Ducoli
PURPOSE: To compare keratometric astigmatism (KA) and different modalities of measuring total corneal astigmatism (TCA) for toric intraocular lens (IOL) calculation and optimize corneal measurements to eliminate the residual refractive astigmatism. SETTING: G.B. Bietti Foundation IRCCS, Rome, Italy. DESIGN: Prospective case series. METHODS: Patients who had a toric IOL were enrolled. Preoperatively, a Scheimpflug camera (Pentacam HR) was used to measure TCA through ray tracing...
September 2017: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/28991337/accuracy-of-a-new-swept-source-optical-coherence-tomography-biometer-for-iol-power-calculation-and-comparison-to-iolmaster
#3
Giacomo Savini, Kenneth J Hoffer, H John Shammas, Jaime Aramberri, Jinhai Huang, Piero Barboni
PURPOSE: To investigate the accuracy of the measurements provided by a new optical biometer (OA-2000, Tomey Corporation, Nagoya, Japan) for calculating the intraocular lens (IOL) power and to compare the refractive outcomes to those obtained with the IOLMaster 500 (Carl Zeiss Meditec, Jena, Germany). METHODS: In this interventional multicenter study, consecutive patients having cataract surgery were enrolled. Only the IOL model used in the largest sample of patients was selected and the eyes implanted with that IOL were subsequently analyzed...
October 1, 2017: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/28885259/clinical-results-of-the-hoffer-h-5-formula-in-2707-eyes-first-5th-generation-formula-based-on-gender-and-race
#4
Kenneth J Hoffer, Giacomo Savini
No abstract text is available yet for this article.
2017: International Ophthalmology Clinics
https://www.readbyqxmd.com/read/28861697/optical-coherence-tomography-angiography-in-acute-arteritic-and-non-arteritic-anterior-ischemic-optic-neuropathy
#5
Nicole Balducci, Mariachiara Morara, Chiara Veronese, Piero Barboni, Nicoletta Lelli Casadei, Giacomo Savini, Vincenzo Parisi, Alfredo A Sadun, Antonio Ciardella
PURPOSE: The purpose of our study was to describe the feature of acute non-arteritic or arteritic anterior ischemic optic neuropathy (NA-AION and A-AION) using optical coherence tomography angiography (OCT-A) and to compare it with fluorescein angiography (FA) and indocyanine green angiography (ICGA). METHODS: In this retrospective, observational case-control study four NA-AION patients and one A-AION patient were examined by FA, ICGA and OCT-A within 2 weeks from disease presentation...
November 2017: Graefe's Archive for Clinical and Experimental Ophthalmology
https://www.readbyqxmd.com/read/28780778/iol-power-calculation-in-short-and-long-eyes
#6
Kenneth J Hoffer, Giacomo Savini
An analysis of the studies published in the past 50 years reveals that the Haigis, Hoffer Q, and Holladay 2 formulas are the best options for intraocular lens power prediction in short eyes (<22 mm). In long eyes (>26 mm), the Barrett Universal II, Haigis (with optimized constants), Olsen, and SRK/T formulas provide the most accurate outcomes for intraocular lens power prediction.
July 2017: Asia-Pacific Journal of Ophthalmology
https://www.readbyqxmd.com/read/28681907/corneal-asphericity-and-iol-power-calculation-in-eyes-with-aspherical-iols
#7
Giacomo Savini, Kenneth J Hoffer, Piero Barboni, Domenico Schiano Lomoriello, Pietro Ducoli
PURPOSE: Given that a previous study found that corneal asphericity influences the refractive outcome of intraocular lens (IOL) power calculation by means of thin-lens formulas in eyes with spherical IOLs, the authors aimed to verify whether such influence can also be observed in eyes with aspherical IOLs. METHODS: In this retrospective comparative case series, IOL power was calculated with the Haigis, Hoffer Q, Holladay 1, and SRK/T formulas in two groups of eyes undergoing phacoemulsification and implantation of an aspherical IOL (Acrysof SN60WF; Alcon Laboratories, Inc...
July 1, 2017: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/28590287/effect-of-gender-and-race-on-ocular-biometry
#8
Kenneth J Hoffer, Giacomo Savini
No abstract text is available yet for this article.
2017: International Ophthalmology Clinics
https://www.readbyqxmd.com/read/28559547/comparison-of-ocular-biometric-measurements-between-a-new-swept-source-optical-coherence-tomography-and-a-common-optical-low-coherence-reflectometry
#9
Rongrong Gao, Hao Chen, Giacomo Savini, Yaxin Miao, Xiaorui Wang, Jing Yang, Weiqi Zhao, Qinmei Wang, Jinhai Huang
The purpose of the current study was to compare the measurements between a new optical biometer based on swept-source optical coherence tomography (SS-OCT), the OA-2000 (Tomey, Japan), and an optical biometer based on optical low coherence reflectometry (OLCR), the Lenstar (Haag-Streit, Switzerland). Ninety-nine eyes of 99 healthy subjects were included. The axial length (AL), central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), keratometry (K) readings, including flat K (Kf), steep K (Ks), mean K (Km), astigmatism vectors J0, J45 at diameters of 2...
May 30, 2017: Scientific Reports
https://www.readbyqxmd.com/read/28463890/estimating-total-corneal-astigmatism-from-anterior-corneal-data
#10
Kristian Næser, Giacomo Savini, Jesper Flethøj Bregnhøj
PURPOSE: To determine keratometric astigmatism (KA), posterior corneal astigmatism (PCA), and total corneal astigmatism (TCA) in 951 normal eyes, to establish a model for estimating TCA from anterior corneal data, and to test this method in a new group of eyes with toric intraocular lenses (TIOLs). METHODS: We used a Pentacam HR (high-resolution) Scheimpflug camera to determine KA, PCA, and TCA in 951 normal eyes. A model to estimate TCA from anterior corneal data was evaluated by the difference (=error) between the measured TCA and the estimated value...
July 2017: Cornea
https://www.readbyqxmd.com/read/28355262/correction-accuracy-of-optical-biometry-combined-with-placido-disc-corneal-topography-for-intraocular-lens-power-calculation
#11
Giacomo Savini, Kenneth J Hoffer, Piero Barboni, Nicole Balducci, Domenico Schiano-Lomoriello, Pietro Ducoli
[This corrects the article DOI: 10.1371/journal.pone.0172634.].
2017: PloS One
https://www.readbyqxmd.com/read/28286264/optical-coherence-tomography-angiography-of-the-peripapillary-retina-and-optic-nerve-head-in-dominant-optic-atrophy
#12
Nicole Balducci, Antonio Ciardella, Roberto Gattegna, Qienyuan Zhou, Maria Lucia Cascavilla, Chiara La Morgia, Giacomo Savini, Vincenzo Parisi, Francesco Bandello, Valerio Carelli, Piero Barboni
Peripapillar and nerve head vessel density (VD) was measured in 10 patients affected by Dominant optic atrophy (DOA) using optical coherence tomography angiography (OCT-A) and compared to the measurements of 15 age- and gender-matched controls. DOA patients showed VD reduction, mostly in the temporal and inferotemporal peripapillary sectors, according to the preferential involvement of the papillomacular bundle. Despite poor best-corrected visual acuity (BCVA), OCT-A revealed good repeatability. VD correlated with functional (mean deviation of visual field and BCVA) and structural (retinal nerve fiber layer thickness) parameters and could be a non-invasive, quantitative tool for the monitoring of the disease and of the therapeutic approaches...
March 10, 2017: Mitochondrion
https://www.readbyqxmd.com/read/28231267/accuracy-of-optical-biometry-combined-with-placido-disc-corneal-topography-for-intraocular-lens-power-calculation
#13
Giacomo Savini, Kenneth J Hoffer, Piero Barboni, Nicole Balducci, Domenico Schiano-Lomoriello, Pietro Ducoli
PURPOSE: To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS: Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferometry and Placido-disc corneal topography. IOL power was calculated with the Hoffer Q, Holladay 1 and SRK/T formulas...
2017: PloS One
https://www.readbyqxmd.com/read/28002110/total-corneal-astigmatism-measurements-agreement-between-2-rotating-scheimpflug-cameras
#14
COMPARATIVE STUDY
Giacomo Savini, Kristian Næser, Domenico Schiano-Lomoriello, Pietro Ducoli
PURPOSE: To investigate agreement between rotating Scheimpflug camera (Pentacam HR, Oculus) and rotating Scheimpflug camera combined with Placido disc corneal topography (Sirius, CSO) in measuring total corneal astigmatism (TCA). METHODS: In this observational study, all patients undergoing cataract surgery with preoperative measurement of TCA by both devices and a validated corneal topographer (Keratron, Optikon 2000) were retrospectively evaluated. Astigmatism analysis was performed with and without vector analysis separately in eyes with with-the-rule, against-the-rule, and oblique astigmatism...
April 2017: Cornea
https://www.readbyqxmd.com/read/27853297/changes-in-choroidal-thickness-follow-the-rnfl-changes-in-leber-s-hereditary-optic-neuropathy
#15
Enrico Borrelli, Giacinto Triolo, Maria Lucia Cascavilla, Chiara La Morgia, Giovanni Rizzo, Giacomo Savini, Nicole Balducci, Paolo Nucci, Rosa Giglio, Fatemeh Darvizeh, Vincenzo Parisi, Francesco Bandello, Alfredo A Sadun, Valerio Carelli, Piero Barboni
Leber's hereditary optic neuropathy (LHON) is typically characterized by vascular alterations in the acute phase. The aim of this study was to evaluate choroidal changes occurring in asymptomatic, acute and chronic stages of LHON. We enrolled 49 patients with LHON, 19 with Dominant Optic Atrophy (DOA) and 22 healthy controls. Spectral Domain-Optical Coherence Tomography (SD-OCT) scans of macular and peripapillary regions were performed in all subjects, to evaluate macular and peripapillary choroidal thickness, and retinal nerve fiber layer (RNFL) thicknes...
November 17, 2016: Scientific Reports
https://www.readbyqxmd.com/read/27722757/comparison-of-al-scan-and-iolmaster-500-partial-coherence-interferometry-optical-biometers
#16
COMPARATIVE STUDY
Kenneth J Hoffer, Giacomo Savini
PURPOSE: To investigate agreement between the ocular biometry measurements provided by a newer optical biometer, the AL-Scan (Nidek Co, Ltd., Gamagori, Japan) and those provided by the IOLMaster 500 (Carl Zeiss Meditec, Jena Germany), which are both based on partial coherence interferometry. METHODS: Axial length, corneal power, and anterior chamber depth (corneal epithelium to lens) were measured in 86 eyes of 86 patients scheduled for cataract surgery using both biometers...
October 1, 2016: Journal of Refractive Surgery
https://www.readbyqxmd.com/read/27548454/hemorrhagic-occlusive-retinal-vasculitis-after-first-eye-cataract-surgery-without-subsequent-second-eye-involvement
#17
Nicole Balducci, Giacomo Savini, Piero Barboni, Pietro Ducoli, Antonio Ciardella
A case of monocular postoperative hemorrhagic occlusive retinal vasculitis (HORV) after uncomplicated bilateral cataract surgery is described. HORV is a severe syndrome that leads to painless visual loss after uncomplicated cataract surgery. The same surgical procedure was adopted in both eyes except for the use of intracameral vancomycin, which was injected only in the eye that developed HORV. Diffuse retinal ischemia with vascular sheathing and intraretinal hemorrhages were detected during the fourth postoperative day...
August 1, 2016: Ophthalmic Surgery, Lasers & Imaging Retina
https://www.readbyqxmd.com/read/27531293/comparison-of-a-new-optical-biometer-using-swept-source-optical-coherence-tomography-and-a-biometer-using-optical-low-coherence-reflectometry
#18
Kenneth J Hoffer, Peter C Hoffmann, Giacomo Savini
PURPOSE: To investigate agreement between the IOLMaster 700 based on swept-source optical coherence tomography (SS-OCT) and the Lenstar LS 900 based on optical low-coherence reflectometry (OLCR). SETTING: Private practice, Castrop-Rouxelle, Germany. DESIGN: Prospective evaluation of diagnostic test. METHODS: Axial length (AL), keratometry (K), anterior chamber depth (corneal epithelium to lens) (ACD), lens thickness, and central corneal thickness (CCT) were measured in 183 eyes of 183 patients...
August 2016: Journal of Cataract and Refractive Surgery
https://www.readbyqxmd.com/read/27503393/repeatability-and-interobserver-reproducibility-of-a-new-optical-biometer-based-on-swept-source-optical-coherence-tomography-and-comparison-with-iolmaster
#19
COMPARATIVE STUDY
Jinhai Huang, Giacomo Savini, Kenneth J Hoffer, Hao Chen, Weicong Lu, Qingjie Hu, Fangjun Bao, Qinmei Wang
OBJECTIVE: To evaluate the precision of the measurements in healthy subjects obtained with a new optical biometer (OA-2000, Tomey, Nagoya, Japan) using swept-source optical coherence tomography (SS-OCT) and compare these measurements with those provided by the IOLMaster v5.4 (Carl Zeiss Meditec AG, Jena, Germany) using partial coherence interferometry (PCI). METHODS: Axial length (AL), keratometry (K) over 2.5 mm and 3.0 mm diameters, anterior chamber depth (ACD) (corneal epithelium to lens), lens thickness (LT), central corneal thickness and corneal diameter (CD) were measured with SS-OCT by two experienced operators...
April 2017: British Journal of Ophthalmology
https://www.readbyqxmd.com/read/27403339/comparison-between-a-new-optical-biometry-device-and-an-anterior-segment-optical-coherence-tomographer-for-measuring-central-corneal-thickness-and-anterior-chamber-depth
#20
Jinhai Huang, Weicong Lu, Giacomo Savini, Hao Chen, Chengfang Wang, Xinxin Yu, Fangjun Bao, Qinmei Wang
Purpose. To compare between a new optical biometer (AL-Scan, Nidek Co., Aichi, Japan) and an anterior segment optical coherence tomographer (Visante AS-OCT, Carl Zeiss Meditec, Dublin, USA) for measuring central corneal thickness (CCT), anterior chamber depth (ACD), and aqueous depth (AD). Methods. Sixty-three eyes of 63 normal subjects were examined with AL-Scan and Visante AS-OCT in this prospective study. One eye per subject was measured three times with both devices to record their CCT, ACD, and AD. All procedures were performed by the same operator...
2016: Journal of Ophthalmology
keyword
keyword
12537
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"