keyword
https://read.qxmd.com/read/36526831/titanium-base-abutments-may-have-similar-long-term-peri-implant-effects-as-non-bonded-one-piece-abutments
#1
REVIEW
Kelvin I Afrashtehfar, Adrian Weber, Samir Abou-Ayash
Design A single-centre (private practice), prospective, longitudinal, split-mouth, single-blind, randomised controlled clinical trial reported peri-implant parameters of individualised abutments bonded to titanium (Ti) bases during a five-year follow-up. The study complied with the ethical principles of the Helsinki Declaration and the CONSORT (Consolidated Standards of Reporting Trials) guidelines. It was approved by the Medical Ethical Committee of the University of Freiburg (013/1630) and registered in the German Clinical Trials Register (DRKS00006163)...
December 2022: Evidence-based Dentistry
https://read.qxmd.com/read/33899126/does-the-macro-design-of-an-implant-affect-the-accuracy-of-template-guided-implantation-a-prospective-clinical-study
#2
JOURNAL ARTICLE
Sigmar Schnutenhaus, Cornelia Edelmann, Heike Rudolph
BACKGROUND: An implant prosthesis aims to ensure the best possible rehabilitation of function and esthetics following tooth loss. Template-guided insertion is used to achieve an optimal position of the implant with regard to prosthetic restorability, bone availability, and condition of the surrounding soft tissues. The accuracy of template-guided implant placement is subject to various influencing factors. The clinically achievable accuracy depending on the macro design of the implant body was investigated in this prospective clinical study...
April 26, 2021: International Journal of Implant Dentistry
https://read.qxmd.com/read/33430004/an-in-vitro-evaluation-of-primary-stability-values-for-two-differently-designed-implants-to-suit-immediate-loading-in-very-soft-bone
#3
JOURNAL ARTICLE
Dirk Krischik, Selen Ergin Tokgöz, Andreas van Orten, Anton Friedmann, Hakan Bilhan
The achievement of sufficient implant stability in poor quality bone seems to be a challenge. Most manufacturers develop special dental implants, which are claimed to show higher stability even in very soft bone. The aim of this experimental study was to compare two recently introduced dental implants with differing thread designs. A total of 11 implants of each group were inserted in the part of the fresh bovine ribs, corresponding to very soft bone. The primary stability was measured with resonance frequency analysis (RFA) and Periotest; the average of two measurements for each method and for each implant was taken and statistical analysis was applied...
January 8, 2021: Dentistry Journal
https://read.qxmd.com/read/32921422/effect-of-airborne-particle-abrasion-of-a-titanium-base-abutment-on-the-stability-of-the-bonded-interface-and-retention-forces-of-crowns-after-artificial-aging
#4
JOURNAL ARTICLE
João Pitta, Felix Burkhardt, Mustapha Mekki, Vincent Fehmer, Philippe Mojon, Irena Sailer
STATEMENT OF PROBLEM: Published data have shown that a mechanical surface treatment of titanium surfaces increases bonding potential. However, most of the studies are based on shear or tensile tests performed on flat-surfaced specimens and do not take into consideration the retention given by the titanium base (ti-base) axial walls and the thermomechanical loading seen in a clinical setting. PURPOSE: The purpose of this in vitro study was to evaluate the influence of different airborne-particle abrasion (APA) methods of the ti-base surface on the stability of the bonded interface and retention forces between these titanium bases and lithium disilicate crowns after thermomechanical aging...
September 10, 2020: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/32266497/clinical-and-patient-reported-outcome-of-implant-restorations-with-internal-conical-connection-in-daily-dental-practices-prospective-observational-multicenter-trial-with-up-to-7-year-follow-up
#5
JOURNAL ARTICLE
Karl-Ludwig Ackermann, Thomas Barth, Claudio Cacaci, Steffen Kistler, Markus Schlee, Michael Stiller
BACKGROUND: The interpretation of the results of randomized clinical trials is often questioned in relation with daily circumstances in practices. This prospective observational multicenter study was instigated to reflect the need for information in real-life situations with dental implants with internal conical implant-abutment connection (Conelog implant system). The implants were followed up at least 5-year post-loading; survival analysis (Kaplan-Meier), changes of soft tissue, and bone level over time, as well as patient satisfaction were evaluated...
April 8, 2020: International Journal of Implant Dentistry
https://read.qxmd.com/read/32205206/soft-tissue-augmentation-around-dental-implants-with-connective-tissue-graft-ctg-and-xenogenic-collagen-matrix-xcm-1-year-randomized-control-trail
#6
RANDOMIZED CONTROLLED TRIAL
Monika Puzio, Jakub Hadzik, Artur Błaszczyszyn, Tomasz Gedrange, Marzena Dominiak
BACKGROUND: The anatomy of soft tissues around dental implants is extremely important to prevent inflammatory periimplant diseases and ensure healthy, stable and long-term survival of a dental implant. Various methods and materials for increasing the physiological thickness of tissues have been described including connective tissue graft (CTG) and xenogenic collagen matrix (XCM). While assessing various materials it is necessary to establish objective measurement method to determine the minimum amount of tissue thickness to maintain a stable level of bone around the implant...
July 2020: Annals of Anatomy
https://read.qxmd.com/read/30934031/mechanical-stability-of-zirconia-meso-abutments-bonded-to-titanium-bases-restored-with-different-monolithic-all-ceramic-crowns
#7
JOURNAL ARTICLE
João Pitta, Stefan P Hicklin, Vincent Fehmer, Johannes Boldt, Petra C Gierthmuehlen, Irena Sailer
PURPOSE: To evaluate the bending moments and failure modes of zirconia meso-abutments bonded to titanium bases restored with different monolithic all-ceramic crowns after aging, and to compare them to titanium abutments restored with all-ceramic crowns. MATERIALS AND METHODS: Forty-eight internal conical connection implants (Conelog, Camlog 4.3 mm diameter) were restored with four different computer-aided design/computed-aided manufacturing (CAD/CAM) abutment-crown combinations (n = 12)...
September 2019: International Journal of Oral & Maxillofacial Implants
https://read.qxmd.com/read/30324572/a-non-interventional-multicenter-study-to-document-the-implants-success-and-survival-rates-in-daily-dental-practices-of-the-conelog-screw-line-implant
#8
JOURNAL ARTICLE
Claudio Cacaci, Karl-Ludwig Ackermann, Thomas Barth, Steffen Kistler, Michael Stiller, Markus Schlee
OBJECTIVE: This multicenter prospective non-interventional study evaluated the success and survival of the CONELOG implants inserted according to the standard protocol with one- or two-step surgery in daily practice three years after loading. Changes of soft tissue and bone level over time, esthetical outcome, and patient satisfaction were assessed. MATERIALS AND METHODS: The study included patients in six centers. The implants were used in accordance with standard practice of each particular center, and the use was documented systematically...
October 15, 2018: Clinical Oral Investigations
https://read.qxmd.com/read/29971991/effect-of-ultraviolet-photofunctionalization-of-dental-titanium-implants-on-osseointegration
#9
JOURNAL ARTICLE
Christian Mehl, Matthias Kern, Friederike Neumann, Telse Bähr, Jörg Wiltfang, Volker Gassling
OBJECTIVE: The aim of the current study was to evaluate the effect of ultraviolet (UV) photofunctionalization of dental titanium implants with exposure to the oral cavity on osseointegration in an animal model. METHODS: Forty-eight titanium implants (Camlog® Conelog® 4.3 mmx9.0 mm) were placed epicrestally into the edentulous jaws of three minipigs and implant stability was assessed by measuring the implant stability quotient (ISQ). Prior to implantation half of the implants were photofunctionalized with intense UV-light...
July 2018: Journal of Zhejiang University. Science. B
https://read.qxmd.com/read/29281715/correlation-between-the-thickness-of-the-crestal-and-buccolingual-cortical-bone-at-varying-depths-and-implant-stability-quotients
#10
JOURNAL ARTICLE
Kanthanat Chatvaratthana, Sita Thaworanunta, Dutmanee Seriwatanachai, Natthamet Wongsirichat
BACKGROUND/PURPOSE: Resonance frequency analysis (RFA) is clinically used in dentistry to access the stiffness of dental implants in surrounding bone. However, the clear advantages and disadvantages of this method are still inconclusive. The aim of this study was to investigate and compare implant stability quotient (ISQ) values obtained from RFA with parameters obtained from a cone beam computed tomography (CBCT) scan of the same region. MATERIALS AND METHODS: Nineteen implants (Conelog) were inserted in the posterior maxillary and mandibular partially edentulous regions of 16 patients...
2017: PloS One
https://read.qxmd.com/read/29248711/ultrasound-assessment-of-soft-tissue-augmentation-around-implants-in-the-aesthetic-zone-using-a-connective-tissue-graft-and-xenogeneic-collagen-matrix-1-year-randomised-follow-up
#11
JOURNAL ARTICLE
Monika Puzio, Artur Błaszczyszyn, Jakub Hadzik, Marzena Dominiak
PURPOSE: A comparative, ultrasound evaluation of the thickness of keratinized mucosa (TKT) around implants one year after gingival augmentation (GA) by means of a connective tissue graft (CTG) and the xenogeneic collagen matrix (CMX). MATERIALS AND METHODS: A total of 75 bone level tapered implants (Conelog® Camlog) were inserted in 57 patients in the aesthetic area of both jaws. The patients were divided into 3 groups: control group I- without GA; group II- GA 3 months before implantation, and group III- GA 3 months after implantation...
May 2018: Annals of Anatomy
https://read.qxmd.com/read/29049323/one-time-versus-repeated-abutment-connection-for-platform-switched-implant-a-systematic-review-and-meta-analysis
#12
REVIEW
Qing-Qing Wang, Ruoxi Dai, Chris Ying Cao, Hui Fang, Min Han, Quan-Li Li
OBJECTIVE: This review aims to compare peri-implant tissue changes in terms of clinical and radiographic aspects of implant restoration protocol using one-time abutment to repeated abutment connection in platform switched implant. METHOD: A structured search strategy was applied to three electronic databases, namely, Pubmed, Embase and Web of Science. Eight eligible studies, including seven randomised controlled studies and one controlled clinical study, were identified in accordance with inclusion/exclusion criteria...
2017: PloS One
https://read.qxmd.com/read/28710653/mechanical-performance-of-cement-and-screw-retained-all-ceramic-single-crowns-on-dental-implants
#13
JOURNAL ARTICLE
Matthias Obermeier, Oliver Ristow, Kurt Erdelt, Florian Beuer
OBJECTIVES: This in-vitro study was performed to compare the contact wear, fracture strength and failure mode of implant-supported all-ceramic single crowns manufactured with various fabrication and fixation concepts. MATERIALS AND METHODS: Fifty dental implants (Conelog Ø 4,3mm/L11mm, Camlog Biotechnologies AG) were embedded and treated with all-ceramic molar single-crowns. Three groups received hand-layered zirconia crowns (IPS e.max Ceram/ IPS e.max ZirCAD, Ivoclar Vivadent AG): CZL (cement-retained zirconia-based layered) group crowns were cemented conventionally, SZL (screw-retained zirconia-based layered) group crowns were screw-retained, MZL (modified zirconia-based layered) group crowns showed a different coping design with screw retention...
March 2018: Clinical Oral Investigations
https://read.qxmd.com/read/28567530/immediate-definitive-individualized-abutments-reduce-peri-implant-bone-loss-a-randomized-controlled-split-mouth-study-on-16-patients
#14
RANDOMIZED CONTROLLED TRIAL
M Erhan Çömlekoğlu, Nejat Nizam, Mine Dündar Çömlekoğlu
OBJECTIVES: This paper aims to observe peri-implant time-related vertical bone level and soft tissue changes with immediate, non-detached glass-ceramic (lithium-disilicate) individualized abutments and dis-/reconnections. MATERIALS AND METHODS: Sixteen split-mouth patients received provisionalized immediate definitive individualized abutments (test T) versus dis-/reconnected individualized abutments (control C). In group T, digital impressions were made by using titanium bases (Conelog, Camlog), and individualized abutments (E...
January 2018: Clinical Oral Investigations
https://read.qxmd.com/read/28042450/removal-torque-evaluation-of-three-different-abutment-screws-for-single-implant-restorations-after-mechanical-cyclic-loading
#15
JOURNAL ARTICLE
T Paepoemsin, P A Reichart, P Chaijareenont, F P Strietzel, P Khongkhunthian
PURPOSE: The aim of this study was to evaluate the removal torque of three different abutment screws and pull out strength of implant-abutment connection for single implant restorations after mechanical cyclic loading. METHODS: The study was performed in accordance with ISO 14801:2007. Three implant groups (n=15) were used: group A, PW Plus® with flat head screw; group B, PW Plus® with tapered screw; and group C, Conelog® with flat head screw. All groups had the same implant-abutment connection feature: cone with mandatory index...
October 2016: Oral & Implantology
https://read.qxmd.com/read/27861650/influence-of-four-different-abutment-materials-and-the-adhesive-joint-of-two-piece-abutments-on-cervical-implant-bone-and-soft-tissue
#16
JOURNAL ARTICLE
Christian Mehl, Volker Gassling, Stephan Schultz-Langerhans, Yahya Açil, Telse Bähr, Jörg Wiltfang, Matthias Kern
PURPOSE: The main aim of this study was to evaluate the influence of four different abutment materials and the adhesive joint of two-piece abutments on the cervical implant bone and soft tissue. MATERIALS AND METHODS: Sixty-four titanium implants (Camlog Conelog; 4.3 ± 9 mm) were placed bone level into the edentulous arches of four minipigs. Four different types of abutments were placed at implant exposure: zirconium dioxide, lithium disilicate, and titanium bonded to a titanium luting base with resin cement; one-piece titanium abutments served as the control...
November 2016: International Journal of Oral & Maxillofacial Implants
1
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.