keyword
https://read.qxmd.com/read/30987026/ratio-between-height-and-thickness-of-the-buccal-tissues-a-pilot-study-on-32-single-implants
#21
JOURNAL ARTICLE
Davide Farronato, Mattia Manfredini, Francesco Mangano, Giada Goffredo, Marco Colombo, Pietro Pasini, Andrea Orsina, Marco Farronato
BACKGROUND: Previous studies have suggested that mucosal height is related to the bone level and soft tissue thickness. The purpose of this pilot study was to investigate the ratio between the height and width of the tissues around single implants with a conical connection and platform switching. METHODS: All patients receiving single implants (Anyridge® , MegaGen, Gyeongbuk, South Korea) and restored with single crowns, in a three-month period, were included in this study...
April 2, 2019: Dentistry Journal
https://read.qxmd.com/read/29862286/correlation-between-insertion-torque-and-implant-stability-quotient-in-tapered-implants-with-knife-edge-thread-design
#22
MULTICENTER STUDY
Domenico Baldi, Teresa Lombardi, Jacopo Colombo, Gabriele Cervino, Giuseppe Perinetti, Roberto Di Lenarda, Claudio Stacchi
Aim: To evaluate the correlation between insertion torque (IT) and implant stability quotient (ISQ) in tapered implants with knife-edge threads. Methods: Seventy-five identical implants (Anyridge, Megagen) were inserted by using a surgical drilling unit with torque control and an integrated resonance frequency analysis module (Implantmed, W&H). IT (N/cm) and ISQ were recorded and implants were divided into three groups ( n = 25) according to the IT: low (<30), medium (30 < IT < 50), and high torque (>50)...
2018: BioMed Research International
https://read.qxmd.com/read/29732018/immediate-functional-loading-of-single-implants-a-multicenter-study-with-4-years-of-follow-up
#23
JOURNAL ARTICLE
Filiep Raes, Tammaro Eccellente, Carolina Lenzi, Michele Ortolani, Giuseppe Luongo, Carlo Mangano, Francesco Mangano
Background. In the current scientific literature there are only few studies on the immediate functional loading of single implants. The aim of the present present study was to evaluate the 4-year survival rate, complication rate and peri-implant marginal bone loss (PIMBL) of immediately loaded single implants inserted in healed ridges and fresh post-extraction sites. Methods. Six centers were involved in this prospective study. The surgical and prosthetic protocol was defined in detail, before the start of recruiting patients...
2018: Journal of Dental Research, Dental Clinics, Dental Prospects
https://read.qxmd.com/read/29557401/immediate-early-6-weeks-and-delayed-loading-3-months-of-single-partial-and-full-fixed-implant-supported-prostheses-1-year-post-loading-data-from-a-multicentre-randomised-controlled-trial
#24
RANDOMIZED CONTROLLED TRIAL
Miltiadis Mitsias, Konstantinos Siormpas, Valeria Pistilli, Anna Trullenque-Eriksson, Marco Esposito
PURPOSE: To compare the clinical outcome of single, partial and complete fixed implant supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks, and conventionally loaded at 3 months (delayed loading). MATERIALS AND METHODS: A total of 54 patients (18 requiring single implants, 18 partial fixed prostheses, and 18 total fixed cross-arch prostheses) were randomised in equal numbers at two private practices to immediate loading (18 patients), early loading (18 patients), and conventional loading (18 patients) according to a parallel group design with three arms...
2018: European Journal of Oral Implantology
https://read.qxmd.com/read/29557400/posterior-atrophic-jaws-rehabilitated-with-prostheses-supported-by-5-%C3%A3-5-mm-implants-with-a-nanostructured-calcium-incorporated-titanium-surface-or-by-longer-implants-in-augmented-bone-3-year-results-from-a-randomised-controlled-trial
#25
RANDOMIZED CONTROLLED TRIAL
Giorgio Gastaldi, Pietro Felice, Valeria Pistilli, Carlo Barausse, Daniela Rita Ippolito, Marco Esposito
PURPOSE: To evaluate whether 5.0 × 5.0 mm dental implants with a novel nanostructured calcium-incorporated titanium surface could be an alternative to implants of at least 10.0 mm long placed in bone augmented with bone substitutes in posterior atrophic jaws. MATERIALS AND METHODS: Forty patients with atrophic posterior (premolar and molar areas) mandibles with 5.0 mm to 7.0 mm bone height above the mandibular canal, and 40 patients with atrophic maxillas with 4...
2018: European Journal of Oral Implantology
https://read.qxmd.com/read/29258208/scanning-electron-microscope-sem-evaluation-of-the-interface-between-a-nanostructured-calcium-incorporated-dental-implant-surface-and-the-human-bone
#26
JOURNAL ARTICLE
Francesco Mangano, Mario Raspanti, Hassan Maghaireh, Carlo Mangano
Purpose . The aim of this scanning electron microscope (SEM) study was to investigate the interface between the bone and a novel nanostructured calcium-incorporated dental implant surface in humans. Methods . A dental implant (Anyridge® , Megagen Implant Co., Gyeongbuk, South Korea) with a nanostructured calcium-incorporated surface (Xpeed® , Megagen Implant Co., Gyeongbuk, South Korea), which had been placed a month earlier in a fully healed site of the posterior maxilla (#14) of a 48-year-old female patient, and which had been subjected to immediate functional loading, was removed after a traumatic injury...
December 17, 2017: Materials
https://read.qxmd.com/read/29234748/early-loading-of-maxillary-titanium-implants-with-a-nanostructured-calcium-incorporated-surface-xpeed-5-year-results-from-a-multicentre-randomised-controlled-trial
#27
RANDOMIZED CONTROLLED TRIAL
Giorgio Gastaldi, Maria Gabriella Grusovin, Pietro Felice, Carlo Barausse, Daniela Rita Ippolito, Marco Esposito
PURPOSE: To evaluate clinical safety and effectiveness of a novel calcium-incorporated titanium implant (Xpeed, MegaGen Implant Co. Limited, Gyeongbuk, South Korea). MATERIALS AND METHODS: In total, 60 patients were randomised to receive one to six titanium implants in the maxilla with either calcium-incorporated (Xpeed) or control resorbable blasted media (RBM) surfaces, according to a parallel group design at two centres. Implants were submerged and exposed at three different endpoints in equal groups of 20 patients at 12, 10 and 8 weeks, respectively...
2017: European Journal of Oral Implantology
https://read.qxmd.com/read/28944355/wide-diameter-immediate-post-extractive-implants-vs-delayed-placement-of-normal-diameter-implants-in-preserved-sockets-in-the-molar-region-1-year-post-loading-outcome-of-a-randomised-controlled-trial
#28
RANDOMIZED CONTROLLED TRIAL
Vittorio Checchi, Pietro Felice, Giovanni Zucchelli, Carlo Barausse, Maurizio Piattelli, Roberto Pistilli, Giovanni Grandi, Marco Esposito
PURPOSE: To compare the effectiveness of 6.0 to 8.0 mm-wide diameter implants, placed immediately after tooth extraction, with conventional 4.0 or 5.0 mm diameter implants placed in a preserved socket after a 4-month period of healing in the molar region. MATERIALS AND METHODS: Just after extraction of one or two molar teeth, and with no vertical loss of the buccal bone in relation to the palatal wall, 100 patients requiring immediate post-extractive implants were randomly allocated to immediate placement of one or two 6...
2017: European Journal of Oral Implantology
https://read.qxmd.com/read/28626763/implant-stability-in-the-posterior-maxilla-a-controlled-clinical-trial
#29
JOURNAL ARTICLE
Raquel Zita Gomes, Mario Ramalho de Vasconcelos, Isabel Maria Lopes Guerra, Rute Alexandra Borges de Almeida, Antonio Cabral de Campos Felino
AIM: To evaluate the primary and secondary stability of implants in the posterior maxilla. METHODS: Patients were allocated into three groups: (A) native bone, (B) partially regenerated bone, and (C) nearly totally regenerated bone. Insertion torque (IT) and implant stability quotient (ISQ) were measured at placement, to evaluate whether satisfactory high primary stability (IT ≥ 45 N/cm; ISQ ≥ 60) was achieved; ISQ was measured 15, 30, 45, and 60 days after placement, to investigate the evolution to secondary stability...
2017: BioMed Research International
https://read.qxmd.com/read/28611844/immediate-loading-of-single-implants-in-the-anterior-maxilla-a-1-year-prospective-clinical-study-on-34-patients
#30
JOURNAL ARTICLE
Miguel Stanley, Filipa Calheiros Braga, Beatriz Mota Jordao
PURPOSE: To present the outcomes of immediately loaded single implants placed in the anterior maxilla. METHODS: Over a 2-year period, all patients referred to a private clinic were considered for enrolment in this study. Inclusion criteria were single-tooth placement in postextraction sockets or healed sites of the anterior maxilla. All implants were immediately loaded and followed for a period of 1 year after the placement of definitive crowns. The outcome measures were implant stability, survival, and success...
2017: International Journal of Dentistry
https://read.qxmd.com/read/28280731/early-bone-formation-around-immediately-loaded-transitional-implants-inserted-in-the-human-posterior-maxilla-the-effects-of-fixture-design-and-surface
#31
RANDOMIZED CONTROLLED TRIAL
Carlo Mangano, Jamil Awad Shibli, Jefferson Trabach Pires, Giuseppe Luongo, Adriano Piattelli, Giovanna Iezzi
Aim. To evaluate the effects of fixture design and surface on the early bone formation around immediately loaded implants inserted in the human posterior maxilla. Materials and Methods. Ten totally edentulous subjects received two transitional implants: one tapered implant with knife-edge threads/nanostructured calcium-incorporated surface (test: Anyridge®, Megagen, Gyeongbuk, South Korea) and one cylindrical implant with self-tapping threads/sandblasted surface (control: EZPlus®, Megagen). The implants were placed according to a split-mouth design and immediately loaded to support an interim complete denture; after 8 weeks, they were removed for histologic/histomorphometric analysis...
2017: BioMed Research International
https://read.qxmd.com/read/28246595/fixed-full-arches-supported-by-tapered-implants-with-knife-edge-thread-design-and-nanostructured-calcium-incorporated-surface-a-short-term-prospective-clinical-study
#32
JOURNAL ARTICLE
Soheil Bechara, Algirdas Lukosiunas, Giorgio Andrea Dolcini, Ricardas Kubilius
Purpose. To evaluate implant survival, peri-implant bone loss, and complications affecting fixed full-arch (FFA) restorations supported by implants with a knife-edge thread design and nanostructured, calcium-incorporated surface. Methods. Between January 2013 and December 2015, all patients referred for implant-supported FFA restorations were considered for enrollment in this study. All patients received implants with a knife-edge thread design and nanostructured calcium-incorporated surface (Anyridge®, Megagen, South Korea) were restored with FFA restorations and enrolled in a recall program...
2017: BioMed Research International
https://read.qxmd.com/read/27999799/alveolar-ridge-reconstruction-with-titanium-meshes-and-simultaneous-implant-placement-a-retrospective-multicenter-clinical-study
#33
MULTICENTER STUDY
Raquel Zita Gomes, Andres Paraud Freixas, Chang-Hun Han, Sohueil Bechara, Isaac Tawil
Objective. To evaluate horizontal bone gain and implant survival and complication rates in patients treated with titanium meshes placed simultaneously with dental implants and fixed over them. Methods. Twenty-five patients treated with 40 implants and simultaneous guided bone regeneration with titanium meshes (i-Gen®, MegaGen, Gyeongbuk, Republic of Korea) were selected for inclusion in the present retrospective multicenter study. Primary outcomes were horizontal bone gain and implant survival; secondary outcomes were biological and prosthetic complications...
2016: BioMed Research International
https://read.qxmd.com/read/27722223/immediate-early-6-weeks-and-delayed-loading-3%C3%A2-months-of-single-implants-4-month-%C3%A2-post-loading-from-a-multicenter-pragmatic-randomised-controlled-trial
#34
RANDOMIZED CONTROLLED TRIAL
Marco Esposito, Konstantinos Siormpas, Miltiadis Mitsias, Soheil Bechara, Anna Trullenque-Eriksson, Roberto Pistilli
PURPOSE: To compare the clinical outcome of single, partial and full fixed implant-supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks and conventionally loaded at 3 months (delayed loading). MATERIALS AND METHODS: Eighty-one patients (27 requiring single implants, 27 requiring partial fixed prostheses and 27 requiring total fixed cross-arch prostheses) were randomised in equal numbers in three private practices to immediate loading (27 patients), early loading (27 patients) and conventional loading (27 patients) according to a parallel group design with three arms...
2016: European Journal of Oral Implantology
https://read.qxmd.com/read/27699890/the-effect-of-implant-macro-thread-design-on-implant-stability-in-the-early-post-operative-period-a-randomized-controlled-pilot-study
#35
RANDOMIZED CONTROLLED TRIAL
Jeffrey J McCullough, Perry R Klokkevold
INTRODUCTION: Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread design on this process is scant. AIM: The specific aim of this study was to evaluate the role of macro-thread design on implant stability in the early post-operative healing period using resonance frequency analysis (RFA)...
October 2017: Clinical Oral Implants Research
https://read.qxmd.com/read/27492985/accuracy-of-torque-limiting-devices-a-comparative-evaluation
#36
COMPARATIVE STUDY
Haydar Albayrak, Hasan Onder Gumus, Funda Tursun, Hasan Huseyin Kocaagaoglu, Halil Ibrahim Kilinc
STATEMENT OF PROBLEM: To prevent the loosening of implant screws, clinicians should be aware of the output torque values needed to achieve the desired preload. Accurate torque-control devices are crucial in this regard; however, little information is currently available comparing the accuracy of mechanical with that of electronic torque-control devices. PURPOSE: The purpose of this in vitro study was to identify and compare the accuracy of different types of torque-control devices...
January 2017: Journal of Prosthetic Dentistry
https://read.qxmd.com/read/27433693/histological-evaluation-of-nano-micro-titanium-implant-surface-treatment-in-beagle-humerus
#37
JOURNAL ARTICLE
Kwidug Yun, Seongsoo Kang, Gyejeong Oh, Hyunpil Lim, Kwangmin Lee, Hongso Yang, Mongsook Vang, Sangwon Park
The objective of this study was to investigate the effects of nano-micro titanium implant surface using histology in beagle dogs. A total of 48 screw-shaped implants (Megagen, Daegu, Korea) which dimensions were 4 mm in diameter and 8.5 mm in length, were used. The implants were classified into 4 groups (n = 12): machined surface (M group), RBM (Resorbable Blasting Media) surface (R group), nano surface which is nanotube formation on the machined surface (MA group) and nano-micro surface which is nanotube formation on the RBM surface (RA group)...
February 2016: Journal of Nanoscience and Nanotechnology
https://read.qxmd.com/read/27402427/short-6-mm-dental-implants-versus-sinus-floor-elevation-and-placement-of-longer-%C3%A2-10-mm-dental-implants-a-randomized-controlled-trial-with-a-3-year-follow-up
#38
RANDOMIZED CONTROLLED TRIAL
Souheil Bechara, Ricardas Kubilius, Giovanni Veronesi, Jefferson T Pires, Jamil A Shibli, Francesco G Mangano
OBJECTIVES: To investigate whether short (6-mm) dental implants could be an alternative to sinus floor elevation (SFE) and placement of longer (≥10-mm) implants in the posterior maxilla. MATERIALS AND METHODS: Over a 3-year period, all patients presenting with partial edentulism in the posterior maxilla were considered for inclusion in this randomized controlled trial. Patients were randomly chosen either to receive short (6-mm) implants (test group [TG]) or to undergo SFE with simultaneous placement of standard-length (≥10-mm) implants (control group [CG])...
September 2017: Clinical Oral Implants Research
https://read.qxmd.com/read/27314118/dental-implants-with-internal-versus-external-connections-5-year-post-loading-results-from-a-pragmatic-multicenter-randomised-controlled-trial
#39
RANDOMIZED CONTROLLED TRIAL
Marco Esposito, Hassan Maghaireh, Roberto Pistilli, Maria Gabriella Grusovin, Sang Taek Lee, Anna Trullenque-Eriksson, Federico Gualini
PURPOSE: To evaluate advantages and disadvantages of identical implants with internal or external connections. MATERIALS AND METHODS: One hundred and twenty patients with any type of edentulism (single tooth, partial and total edentulism), requiring one implant-supported prosthesis were randomly allocated in two equal groups to receive either implants with an external connection (EC) or implants of the same type with an internal connection (IC) (EZ Plus, MegaGen Implant, Gyeongbuk, South Korea), at four centres...
2016: European Journal of Oral Implantology
https://read.qxmd.com/read/27298621/soft-tissue-stability-around-single-implants-inserted-to-replace-maxillary-lateral-incisors-a-3d-evaluation
#40
JOURNAL ARTICLE
F G Mangano, F Luongo, G Picciocchi, C Mortellaro, K B Park, C Mangano
Purpose. To evaluate the soft tissue stability around single implants inserted to replace maxillary lateral incisors, using an innovative 3D method. Methods. We have used reverse-engineering software for the superimposition of 3D surface models of the dentogingival structures, obtained from intraoral scans of the same patients taken at the delivery of the final crown (S1) and 2 years later (S2). The assessment of soft tissues changes was performed via calculation of the Euclidean surface distances between the 3D models, after the superimposition of S2 on S1; colour maps were used for quantification of changes...
2016: International Journal of Dentistry
keyword
keyword
104949
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.