keyword
MENU ▼
Read by QxMD icon Read
search

Pillcam

keyword
https://www.readbyqxmd.com/read/28229607/therapeutic-impact-of-colon-capsule-endoscopy-with-pillcam%C3%A2-colon-2-after-incomplete-standard-colonoscopy-a-spanish-multicenter-study
#1
Óscar Nogales, Javier García-Lledó, Marisol Luján, David Nicolás, José Francisco Juanmartiñena, Begoña González-Suárez, Francisco Sánchez Ceballos, Ignacio Couto, José Olmedo, Cristina Garfia, Cristina Carretero, Ignacio Fernández Urién, Sarbelio Rodríguez, Matilde Asteinza, Pilar Olivencia, Ángeles Masedo, Miguel Muñoz-Navas, Beatriz Merino, Cecilia González Asanza
INTRODUCTION: Colon capsule endoscopy (CCE) is an alternative approach for the examination of the colon in patients who refuse colonoscopy or after incomplete colonoscopy (IC). We conducted a study to determine the frequency of complete colonoscopy after IC, the diagnostic yield of CCE, the therapeutic impact of lesions found in CCE, the level of colon cleanliness and the safety of the procedure. METHODS: We performed a prospective, multicenter study involving ten Spanish hospitals...
February 23, 2017: Revista Española de Enfermedades Digestivas
https://www.readbyqxmd.com/read/28122387/clinical-validity-of-flexible-spectral-imaging-color-enhancement-fice-in-small-bowel-capsule-endoscopy-a-systematic-review-and-meta-analysis
#2
Diana E Yung, Pedro Boal Carvalho, Andry Giannakou, Uri Kopylov, Bruno Rosa, Emanuele Rondonotti, Ervin Toth, John N Plevris, Anastasios Koulaouzidis
Patients and methods A comprehensive literature search was conducted. We measured pooled rate of lesion visualization improvement and improvement in lesion detection comparing FICE settings 1 - 3 and WLE, for angioectasias and ulcers/erosions. Pooled results were derived using the random-effects model because of high heterogeneity as measured by I(2). Repeated-measures analysis of variance (ANOVA) was used to measure differences in lesion detection between WLE and the three FICE modes. Results 13 studies were analyzed...
March 2017: Endoscopy
https://www.readbyqxmd.com/read/28103205/is-the-use-of-agile-patency-capsule-prior-to-videocapsule-endoscopy-useful-in-all-patients-with-spondyloarthritis
#3
Andrada Gheorghe, Denise Carmen Mihaela Zahiu, Theodor Alexandru Voiosu, Bogdan Radu Mateescu, Mihail Radu Voiosu, Mihai Rimbaş
BACKGROUND AND AIMS: As already known, spondyloarthritis patients present a striking resemblance in intestinal inflammation with early Crohn's disease. Moreover, the frequent use of nonsteroidal anti-inflammatory drugs is an important part of their treatment. Both conditions could lead to intestinal stenoses. Therefore we proposed to investigate the usefulness of the patency capsule test in patients with spondyloarthritis. MATERIAL AND METHODS: 64 consecutive patients (33 males; mean age 38 ± 11 years) that fulfilled the AMOR criteria for seronegative spondyloarthropathy (59...
January 18, 2017: Romanian Journal of Internal Medicine, Revue Roumaine de Médecine Interne
https://www.readbyqxmd.com/read/28079233/suspected-blood-indicator-in-capsule-endoscopy-a-valuable-tool-for-gastrointestinal-bleeding-diagnosis
#4
Pedro Boal Carvalho, Joana Magalhães, Francisca Dias DE Castro, Sara Monteiro, Bruno Rosa, Maria João Moreira, José Cotter
BACKGROUND: Small bowel bleeding is a leading indication for small bowel capsule endoscopy. The Suspected Blood Indicator (SBI) is a software feature directed to automatically detect bleeding lesions during small bowel capsule endoscopy. OBJECTIVE: - We aimed to assess SBI diagnostic accuracy for small bowel haemorrhage or potentially bleeding lesions during small bowel capsule endoscopy for small bowel bleeding. Methods - Single-centre retrospective study including 281 consecutive small bowel capsule endoscopy performed for small bowel bleeding during 6 years...
January 2017: Arquivos de Gastroenterologia
https://www.readbyqxmd.com/read/28052292/evaluation-for-the-clinical-efficacy-of-colon-capsule-endoscopy-in-the-detection-of-laterally-spreading-tumors
#5
COMPARATIVE STUDY
Atsushi Igawa, Shiro Oka, Shinji Tanaka, Ichiro Otani, Sayoko Kunihara, Kazuaki Chayama
BACKGROUND AND AIM: The manner in which colorectal lesions are being detected with PillCam COLON2 capsule endoscopy (CCE2) has markedly improved in recent days. However, limited data are available on CCE2 for detecting laterally spreading tumors (LSTs). The aim of this study was to compare CCE2 with optical colonoscopy (OC), which is currently the gold standard used in the detection of LSTs. METHODS: We performed a prospective, single-academic center study comparing CCE2 with OC in patients with LSTs diagnosed using OC, which was performed during the 3-month period prior to CCE2...
2017: Digestion
https://www.readbyqxmd.com/read/27761464/erratum-to-pillcam-colon-capsule-endoscopy-pcce-in-colonic-diseases
#6
(no author information available yet)
[This corrects the article DOI: 10.21037/atm.2016.08.28.].
September 2016: Annals of Translational Medicine
https://www.readbyqxmd.com/read/27747276/extracolonic-findings-with-the-pillcam-colon-is-panendoscopy-with-capsule-endoscopy-closer
#7
Javier Romero-Vázquez, Ángel Caunedo-Álvarez, Alba Belda-Cuesta, Victoria Alejandra Jiménez-García, Francisco Pellicer-Bautista, Juan Manuel Herrerías-Gutiérrez
Background and study aims: Colon capsules display images from the moment they are ingested, making the study of other extracolonic areas possible. The aim of this study was to analyze the significance of these extracolonic findings. Patients and methods: In this single-center, prospective study, 165 patients underwent colon capsule endoscopy (CCE) between September 2009 and October 2012 to rule out colonic pathology. Images were recorded, without interruptions, from the moment the capsule was ingested until its battery ran out...
October 2016: Endoscopy International Open
https://www.readbyqxmd.com/read/27701883/validation-of-the-computed-assessment-of-cleansing-score-with-the-mirocam%C3%A2-system
#8
Ana Ponte, Rolando Pinho, Adélia Rodrigues, Joana Silva, Jaime Rodrigues, João Carvalho
BACKGROUND AND AIMS: A computed assessment of cleansing (CAC) score was developed to objectively evaluate small-bowel cleansing in the PillCam® capsule endoscopy (CE) system and to overcome the subjectivity and complexity of previous scoring systems. Our study aimed to adapt the CAC score to the Mirocam® system, evaluate its reliability with the Mirocam® CE system and compare it with three validated subjective grading scales. PATIENTS AND METHODS: Thirty CE were prospectively and independently reviewed by two authors who classified the degree of small-bowel cleanliness according to a quantitative index, a qualitative evaluation and an overall adequacy assessment...
November 2016: Revista Española de Enfermedades Digestivas
https://www.readbyqxmd.com/read/27698664/colon-capsule-endoscopy-review-and-perspectives
#9
REVIEW
David Friedel, Rani Modayil, Stavros Stavropoulos
Colon capsule endoscopy utilizing PillCam COLON 2 capsule allows for visualization potentially of the entire colon and is currently approved for patients who cannot withstand the rigors of traditional optical colonoscopy (OC) and associated sedation as well as those that had an OC that was incomplete for technical reasons other than a poor preparation. We will then describe the prior experience and current status of colon capsule endoscopy.
2016: Gastroenterology Research and Practice
https://www.readbyqxmd.com/read/27668227/pillcam-colon-capsule-endoscopy-pcce-in-colonic-diseases
#10
REVIEW
Dan Carter, Rami Eliakim
Diseases affecting the colon are common worldwide and can cause a major health problem. Colorectal cancer (CRC) as well as Inflammatory bowel diseases represent a major cause of morbidity and mortality in western countries. PillCam colon capsule endoscopy (PCCE) is a novel and promising technology that can be useful for the screening and monitoring of colonic diseases. In the recent years many articles examined the use of various versions of PCCE-the 1st and 2nd generation versus various other endoscopic or radiologic modalities both for detection of colonic polyps or cancer and in both ulcerative colitis (UC) and Crohn's disease...
August 2016: Annals of Translational Medicine
https://www.readbyqxmd.com/read/27640052/retention-of-the-cellophane-wall-of-a-patency-capsule-by-intestinal-stenosis-a-report-of-three-cases
#11
Keiko Saito, Tomoo Nakagawa, Hirotaka Koseki, Takashi Taida, Takehiro Sakurai, Sayuri Yoshihama, Masaya Saito, Daisuke Maruoka, Tomoaki Matsumura, Hirotsugu Watabe, Makoto Arai, Tatsuro Katsuno, Osamu Yokosuka
Here we report three cases in which the cellophane wall of the PillCam(®) patency capsule (tag-less PC), lacking a radio frequency identification tag, was retained. Case 1 A 33-year-old man with Crohn's disease (CD) who was administered the tag-less PC, subsequently underwent resection for perforated colon. We recovered the cellophane wall that could perforate the intestine and cause peritonitis. Case 2 A 34-year-old man with a recurring intestinal obstruction of unknown cause was administered the tag-less PC test...
December 2016: Clinical Journal of Gastroenterology
https://www.readbyqxmd.com/read/27333609/automated-adaptive-brightness-in-wireless-capsule-endoscopy-using-image-segmentation-and-sigmoid-function
#12
Ravi Shrestha, Shahed K Mohammed, Md Mehedi Hasan, Xuechao Zhang, Khan A Wahid
Wireless capsule endoscopy (WCE) plays an important role in the diagnosis of gastrointestinal (GI) diseases by capturing images of human small intestine. Accurate diagnosis of endoscopic images depends heavily on the quality of captured images. Along with image and frame rate, brightness of the image is an important parameter that influences the image quality which leads to the design of an efficient illumination system. Such design involves the choice and placement of proper light source and its ability to illuminate GI surface with proper brightness...
August 2016: IEEE Transactions on Biomedical Circuits and Systems
https://www.readbyqxmd.com/read/27305848/impact-of-demographic-and-clinical-parameters-on-video-capsule-transit-time
#13
Eva Niv, Hadassa Pinchasovich, Henit Yanai
BACKGROUND: Small bowel (SB) capsule endoscopy (CE) studies provide data on both gastric and SB transit times (GTT and SBTT, respectively). AIMS: This study aimed to evaluate the influence of demographic and clinical parameters on the GTT and SBTT. Transit times for two generations of capsules (Pillcam SB2 and SB3) were also compared. METHODS: Consecutive adult patients undergoing CE were included. GTT, SBTT, and cecum arrival rates were calculated and correlated to demographics and clinical characteristics...
October 2016: European Journal of Gastroenterology & Hepatology
https://www.readbyqxmd.com/read/27194532/symptomatic-patency-capsule-retention-in-suspected-crohn-s-disease
#14
Bjørn Rasmussen, Torben Nathan, Michael Dam Jensen
The main limitation of capsule endoscopy is the risk of capsule retention. In patients with suspected Crohn's disease, however, this complication is rare, and if a small bowel stenosis is not reliably excluded, small bowel patency can be confirmed with the Pillcam patency capsule. We present two patients examined for suspected Crohn's disease who experienced significant symptoms from a retained patency capsule. Both patients had Crohn's disease located in the terminal ileum. In one patient, the patency capsule caused abdominal pain and vomiting and was visualized at magnetic resonance enterography 9 days after ingestion...
December 2016: Journal of Crohn's & Colitis
https://www.readbyqxmd.com/read/27186182/esophageal-capsule-endoscopy-is-not-the-optimal-technique-to-determine-the-need-for-primary-prophylaxis-in-patients-with-cirrhosis
#15
Karen L Krok, Rebecca Rankin Wagennar, Sergey V Kantsevoy, Paul J Thuluvath
INTRODUCTION: Capsule endoscopy has been suggested as a potential alternative to endoscopy for detection of esophagogastric varices and severe portal hypertensive gastropathy (PHG). The aim of the study was to determine whether PillCam esophageal capsule endoscopy could replace endoscopy for screening purposes. MATERIAL AND METHODS: Sixty-two patients with cirrhosis with no previous variceal bleeding had PillCam capsule endoscopy and video endoscopy performed on the same day...
April 1, 2016: Archives of Medical Science: AMS
https://www.readbyqxmd.com/read/27092333/morpho-functional-evaluation-of-small-bowel-using-wireless-motility-capsule-and-video-capsule-endoscopy-in-patients-with-known-or-suspected-crohn-s-disease-pilot-study
#16
Diana Yung, Sarah Douglas, Anthony R Hobson, Andry Giannakou, John N Plevris, Anastasios Koulaouzidis
BACKGROUND AND STUDY AIMS: SmartPill(®) (Given Imaging Corp.,Yoqneam,Israel) is an ingestible, non-imaging capsule that records physiological data including contractions and pH throughout the gastrointestinal tract. There are scarce data looking at SmartPill(®) assessment of patients with known/suspected small-bowel Crohn's Disease (CD). This pilot study aims to investigate feasibility and safety of SmartPill(®) to assess gut motility in this group.  PATIENTS AND METHODS: Over 1 year, patients with known/suspected CD, referred for small-bowel capsule endoscopy (SBCE), were invited to participate and 12 were recruited (7 female, 5 male, mean age 44...
April 2016: Endoscopy International Open
https://www.readbyqxmd.com/read/27049493/small-bowel-capsule-endoscopy-and-portal-hypertensive-enteropathy-in-cirrhotic-patients-results-from-a-tertiary-referral-centre
#17
Konstantinos J Dabos, Diana E Yung, Leonidas Bartzis, Peter C Hayes, John N Plevris, Anastasios Koulaouzidis
BACKGROUND AND RATIONALE: Portal hypertensive enteropathy (PHE) remains difficult to diagnose in patients with cirrhosis and portal hypertension. Limited test choices exist for the inspection of the small bowel in these patients. Small bowel capsule endoscopy (SBCE) is ideal in this situation but rarely performed. We aimed to determine the prevalence of PHE using SBCE in a cirrhotic patient population and correlate its presence with clinical and CT imaging findings. MATERIAL AND METHODS: We retrospectively analysed data from cirrhotic patients who underwent SBCE at our unit...
May 2016: Annals of Hepatology
https://www.readbyqxmd.com/read/26973404/pillcam%C3%A2-sb3-capsule-does-the-increased-frame-rate-eliminate-the-risk-of-missing-lesions
#18
LETTER
Sara Monteiro, Francisca Dias de Castro, Pedro Boal Carvalho, Maria João Moreira, Bruno Rosa, José Cotter
Since its emergence in 2000, small bowel capsule endoscopy (SBCE) has assumed a pivotal role as an investigation method for small bowel diseases. The PillCam(®) SB2-ex offers 12 h of battery time, 4 more than the previous version (SB2). Rahman et al recently found that the PillCam(®) SB2-ex has a significantly increased completion rate, although without higher diagnostic yield, compared with the SB2. We would like to discuss these somewhat surprising results and the new potentialities of the PillCam(®) SB3 regarding the diagnostic yield of small bowel studies...
March 14, 2016: World Journal of Gastroenterology: WJG
https://www.readbyqxmd.com/read/26880902/clinical-experience-with-the-pillcam-patency-capsule-prior-to-video-capsule-endoscopy-a-real-world-experience
#19
C Römmele, J Brueckner, H Messmann, S K Gölder
Background. In patients with known or suspected risk factors for gastrointestinal stenosis, the PillCam patency capsule (PC) is given before a video capsule endoscopy (VCE) in order to minimize the risk of capsule retention (CR). CR is considered unlikely upon excretion of the PC within 30 hours, excretion in an undamaged state after 30 hours, or radiological projection to the colon. Methods. We performed a retrospective analysis of 38 patients with risk factors for CR, who received a PC from 02/2013 to 04/2015 at Klinikum Augsburg...
2016: Gastroenterology Research and Practice
https://www.readbyqxmd.com/read/26854834/feasibility-of-a-colon-capsule-overnight-procedure-followed-by-colonoscopy
#20
T Brechmann, W Schmiegel, L Klute, T Rösch, C Pox
BACKGROUND AND AIM: Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. METHODS: Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study...
February 2016: Zeitschrift Für Gastroenterologie
keyword
keyword
102072
1
2
Fetch more papers »
Fetching more papers... Fetching...
Read by QxMD. Sign in or create an account to discover new knowledge that matter to you.
Remove bar
Read by QxMD icon Read
×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"