journal
https://read.qxmd.com/read/26715832/sample-preparation-of-eggs-from-laying-hens-using-quechers-dispersive-extraction-for-the-simultaneous-determination-of-melamine-and-cyromazine-residues-by-hplc-dad
#21
JOURNAL ARTICLE
Niki Tsartsali, Victoria F Samanidou
A quick, easy, cheap, effective, rugged, and safe (QuEChERS) dispersive extraction method is proposed herein for the isolation and cleanup of melamine and cyromazine from chicken egg yolk. Analytes are determined by high-performance liquid chromatography using photodiode array detector after separation on a LiChroCART® (250 × 4 mm)-LiChrospher® RP-8e, 5 μm analytical column using a mobile phase of 0.1% trifluoracetic acid and methanol (80:20 v/v) delivered isocratically at a flow rate of 1 mL/minute. Extraction of isolated compounds was achieved by methanol and acetonitrile mixture (1:1 v/v)...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26692760/a-high-performance-thin-layer-chromatography-hptlc-method-for-simultaneous-determination-of-diphenhydramine-hydrochloride-and-naproxen-sodium-in-tablets
#22
JOURNAL ARTICLE
R P Bhole, S S Shinde, S S Chitlange, S B Wankhede
A rapid and simple high-performance thin layer chromatography (HPTLC) method with densitometry at 230 nm was developed and validated for simultaneous determination of diphenhydramine hydrochloride (DPH) and naproxen sodium (NPS) from pharmaceutical preparation. The separation was carried out on aluminum plates precoated with silica gel 60 F254 using mobile phase toluene:methanol:glacial acetic acid (7.5:1:0.2, v/v/v). The linearity range lies between 200 and 1200 ng/band for DPH and 1760 and 10,560 ng/band for NPS with correlation coefficients of 0...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26640364/organ-on-a-chip-new-platform-for-biological-analysis
#23
REVIEW
Fan An, Yueyang Qu, Xianming Liu, Runtao Zhong, Yong Luo
Direct detection and analysis of biomolecules and cells in physiological microenvironment is urgently needed for fast evaluation of biology and pharmacy. The past several years have witnessed remarkable development opportunities in vitro organs and tissues models with multiple functions based on microfluidic devices, termed as "organ-on-a-chip". Briefly speaking, it is a promising technology in rebuilding physiological functions of tissues and organs, featuring mammalian cell co-culture and artificial microenvironment created by microchannel networks...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26609215/spectrophotometric-investigations-of-macrolide-antibiotics-a-brief-review
#24
REVIEW
Mrudul R Keskar, Ravin M Jugade
Macrolides, one of the most commonly used class of antibiotics, are a group of drugs produced by Streptomyces species. They belong to the polyketide class of natural products. Their activity is due to the presence of a large macrolide lactone ring with deoxy sugar moieties. They are protein synthesis inhibitors and broad-spectrum antibiotics, active against both gram-positive and gram-negative bacteria. Different analytical techniques have been reported for the determination of macrolides such as chromatographic methods, flow injection methods, spectrofluorometric methods, spectrophotometric methods, and capillary electrophoresis methods...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26549970/immunohistochemical-markers-of-soft-tissue-tumors-pathologic-diagnosis-genetic-contributions-and-therapeutic-options
#25
REVIEW
David M Parham
After ~30 years of widespread usage, immunohistochemistry (IHC) has become a standard method of diagnosis for surgical pathology. Because of the plethora of diagnoses and often subtle nature of diagnostic criteria, IHC finds particular utility in soft tissue tumors. The use of progressively small amounts of tissue for diagnosis highlights the importance of this method. The sensitivity and crispness of IHC stains have progressively improved with the advent of new techniques. Traditionally, IHC detects cell-typic markers that characterize cell phenotypes, such as chromogranin for neuroectodermal tissue, myogenin for skeletal muscle, and cytokeratin for epithelium...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26483607/organophosphate-hydrolase-in-conductometric-biosensor-for-the-detection-of-organophosphate-pesticides
#26
JOURNAL ARTICLE
Ani Mulyasuryani, Sasangka Prasetyawan
The research has developed an enzyme biosensor for the detection organophosphate pesticide residues. The biosensor consists of a pair of screen-printed carbon electrode (SPCEs). One of electrodes contains immobilized organophosphate hydrolase (OPH) on a chitosan membrane by cross-linking it with glutaraldehyde. The area of the electrodes was optimized to 3, 5, and 7 mm(2). The OPH was isolated from Pseudomonas putida, and was purified by the ammonium sulfate precipitation method, with 6444 ppm (A) and 7865 ppm (B)...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26339186/determination-and-validation-of-a-solid-phase-extraction-gas-chromatography-mass-spectrometry-for-the-quantification-of-methadone-and-its-principal-metabolite-in-human-plasma
#27
JOURNAL ARTICLE
Fouad Chiadmi, Joël Schlatter
This study aimed to develop a solid-phase extraction gas chromatography-selected ion monitoring-mass spectrometry method for the determination of methadone (MDN) and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) in human plasma. The linear response was obtained over the concentration range from 10 to 2000 ng/mL for MDN and EDDP. The absolute recoveries of MDN and EDDP were 95.9%-98.9% and 94.8%-102.4%, with relative standard deviation (RSD) ranging from 1.8% to 2.7% and 1.8% to 3.9%, respectively...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/26279621/spectrophotometric-determination-of-cefixime-trihydrate-in-pharmaceutical-formulations-based-on-ion-pair-reaction-with-bromophenol-blue
#28
JOURNAL ARTICLE
Mrudul R Keskar, Ravin M Jugade
Cefixime trihydrate is a broad spectrum cephalosporin antibiotic, effective against gram-positive and gram-negative bacterial infections. Simple and rapid method has been developed for the determination of cefixime trihydrate in bulk and pharmaceutical formulations. This method was based on the formation of bluish-green ion-pair complex of cefixime trihydrate with bromophenol blue in dimethyl sulfoxide (DMSO)-acetonitrile medium. Different parameters were studied and optimized. A 2:1 complex was formed between the drug and reagent almost instantaneously at room temperature which has λmax of 610 nm...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/25698878/determination-of-chlorophenoxy-acid-methyl-esters-and-other-chlorinated-herbicides-by-gc-high-resolution-qtofms-and-soft-lonization
#29
JOURNAL ARTICLE
Viorica Lopez-Avila, Patrick Roach, Randall Urdahl
Gas chromatography with quadrupole time-of-flight mass spectrometry (GC-QTOFMS) and soft ionization generated by a rare-gas plasma is described here for the determination of various chlorophenoxy acid methyl esters and a few chlorinated herbicides. This plasma-based, wavelength-selectable ionization source, which can use Xe, Kr, Ar, Ne, or He as the plasma gas, enables ionization of GC-amenable compounds with ionization energies below 8.4, 10, 11.6, 16.5, or 22.4 eV, respectively. The advantages of soft ionization include enhanced molecular ions, reduced fragmentation, and reduced background noise as compared to electron ionization...
2015: Analytical Chemistry Insights
https://read.qxmd.com/read/25452691/a-study-of-method-development-validation-and-forced-degradation-for-simultaneous-quantification-of-paracetamol-and-ibuprofen-in-pharmaceutical-dosage-form-by-rp-hplc-method
#30
JOURNAL ARTICLE
Md Sarowar Jahan, Md Jahirul Islam, Rehana Begum, Ruhul Kayesh, Asma Rahman
A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/25210422/a-continuous-flow-system-for-the-measurement-of-ambient-nitrogen-oxides-no-no2-using-rhodamine-b-hydrazide-as-a-chemosensor
#31
JOURNAL ARTICLE
Pandurangappa Malingappa, Venkataramanappa Yarradoddappa
A new chemosensor has been used to monitor atmospheric nitrogen oxides [NO + NO2] at parts per billion (ppb) level. It is based on the catalytic reaction of nitrogen oxides with rhodamine B hydrazide (RBH) to produce a colored compound through the hydrolysis of the amide bond of the molecule. A simple colorimeter has been used to monitor atmospheric nitrogen dioxide at ppb level. The air samples were purged through a sampling cuvette containing RBH solution using peristaltic pump. The proposed method has been successfully applied to monitor the ambient nitrogen dioxide levels at traffic junction points within the city limits and the results obtained are compared with the standard Griess-Ilosvay method...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/25057239/preliminary-development-of-a-fiber-optic-sensor-for-measuring-bilirubin
#32
JOURNAL ARTICLE
Steven M Babin, Raymond M Sova
Preliminary development of a fiber optic bilirubin sensor is described, where an unclad sensing portion is used to provide evanescent wave interaction of the transmitted light with the chemical environment. By using a wavelength corresponding to a bilirubin absorption peak, the Beer-Lambert Law can be used to relate the concentration of bilirubin surrounding the sensing portion to the amount of absorbed light. Initial testing in vitro suggests that the sensor response is consistent with the results of bulk absorption measurements as well as the Beer-Lambert Law...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24963271/corrigendum-to-utility-of-experimental-design-in-pre-column-derivatization-for-the-analysis-of-tobramycin-by-hplc-fluorescence-detection-application-to-ophthalmic-solution-and-human-plasma
#33
https://read.qxmd.com/read/24940040/determination-of-xanthine-in-the-presence-of-hypoxanthine-by-adsorptive-stripping-voltammetry-at-the-mercury-film-electrode
#34
JOURNAL ARTICLE
Percio Augusto Mardini Farias, Arnaldo Aguiar Castro
A stripping method for the determination of xanthine in the presence of hypoxanthine at the submicromolar concentration levels is described. The method is based on controlled adsorptive accumulation at the thin-film mercury electrode followed by a fast linear scan voltammetric measurement of the surface species. Optimum experimental conditions were found to be the use of 1.0 × 10(-3) mol L(-1) NaOH solution as supporting electrolyte, an accumulation potential of 0.00 V for xanthine and -0.50 V for hypoxanthine-copper, and a linear scan rate of 200 mV second(-1)...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24932100/kinetic-study-of-the-alkaline-degradation-of-oseltamivir-phosphate-and-valacyclovir-hydrochloride-using-validated-stability-indicating-hplc
#35
JOURNAL ARTICLE
Ramzia I Al-Bagary, Asmaa A El-Zaher, Fahima A Morsy, Mai M Fouad
Aqueous alkaline degradation was performed for oseltamivir phosphate (OP) and valacyclovir hydrochloride (VA). Isocratic stability indicating the use of high-performance liquid chromatography (HPLC) was presented for each drug in the presence of its degradation product. The separations were performed using the Nucleosil ODS column and a mobile phase consisting of phosphate buffer (pH = 7), acetonitrile, and methanol 50:25:25 (v/v/v) for OP. For VA separation, a Nucleosil CN column using phosphate buffer (pH = 7) and methanol 85:15 (v/v) was used as a mobile phase...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24868142/a-uplc-ms-method-for-the-determination-of-ofloxacin-concentrations-in-aqueous-humor
#36
JOURNAL ARTICLE
Panagiotis Plotas, Charalampos Anastasopoulos, Olga E Makri, Michalis Leotsinidis, Constantine D Georgakopoulos
A rapid, simple, and specific method based on ultra performance liquid chromatography (UPLC) with mass spectrometry detection has been developed for quantitative analysis of ofloxacin in human aqueous humor using tobramycin as internal standard (IS). Chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 Shield column (150 × 2.1 mm, 1.7 μm) eluted with 95:5 water: acetonitrile (v/v) containing 0.1% formic acid and a flow rate of 0.3 mL/minute. The total analysis time was three minutes with ofloxacin eluting at 1...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24855334/spectrophotometric-and-spectrofluorimetric-studies-on-azilsartan-medoxomil-and-chlorthalidone-to-be-utilized-in-their-determination-in-pharmaceuticals
#37
JOURNAL ARTICLE
Walid M Ebeid, Ehab F Elkady, Asmaa A El-Zaher, Ramzia I El-Bagary, Gabor Patonay
The recently approved angiotensin II receptor blocker, azilsartan medoxomil (AZL), was determined spectrophotometrically and spectrofluorimetrically in its combination with chlorthalidone (CLT) in their combined dosage form. The UV-spectrophotometric technique depends on simultaneous measurement of the first derivative spectra for AZL and CLT at 286 and 257 nm, respectively, in methanol. The spectrofluorimetric technique depends on measurement of the fourth derivative of the synchronous spectra intensities of AZL in presence of CLT at 298 nm in methanol...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24812483/application-of-nanofiber-packed-spe-for-determination-of-urinary-1-hydroxypyrene-level-using-hplc
#38
JOURNAL ARTICLE
Okechukwu Clinton Ifegwu, Chimezie Anyakora, Samuel Chigome, Nelson Torto
It is always desirable to achieve maximum sample clean-up, extraction, and pre-concentration with the minimum possible organic solvent. The miniaturization of sample preparation devices was successfully demonstrated by packing 10 mg of 11 electrospun polymer nanofibers into pipette tip micro column and mini disc cartridges for efficient pre-concentration of 1-hydroxypyrene in urine samples. 1-hydroxypyrene is an extensively studied biomarker of the largest class of chemical carcinogens. Excretory 1-hydroxypyrene was monitored with HPLC/fluorescence detector...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24653644/buprenorphine-and-norbuprenorphine-determination-in-mice-plasma-and-brain-by-gas-chromatography-mass-spectrometry
#39
JOURNAL ARTICLE
Fouad Chiadmi, Joël Schlatter
A gas chromatography tandem mass spectrometry method for quantification of buprenorphine (BUP) and norbuprenorphine (NBUP) in brain and plasma samples from mice was developed and validated. Analytes were extracted from the brain or plasma by solid phase extraction and quantified within 20 minutes. Calibration was achieved by linear regression with a 1/x weighting factor and d4-buprenorphine internal standard. All products were linear from 1 to 2000 ng/mL with a correlation of determination >0.99. Assay accuracy and precision of back-calculated standards were within ±10%...
2014: Analytical Chemistry Insights
https://read.qxmd.com/read/24634579/synthesis-and-characterization-of-maillard-reaction-products-of-salbutamol-and-terbutaline-with-lactose-and-development-and-validation-of-an-lc-method-for-the-determination-of-salbutamol-and-terbutaline-in-the-presence-of-these-impurities
#40
JOURNAL ARTICLE
Asmaa A El-Zaher, Marwa A Fouad, Ehab F Elkady
Being secondary amines, both salbutamol (SLB) and terbutaline (TRB) react by Maillard reaction (MR) with lactose, which is added as an inactive ingredient in tablets. The Amadori rearrangement products were synthesized, isolated, and characterized by mass spectrometry. In addition, a simple, selective, and precise reversed-phase liquid chromatography (LC) method was developed and validated for the determination of SLB and TRB in tablets, each in the presence of its MR impurity. The chromatographic separation was performed on a Symmetry(®) Waters C18 column (150 mm × 4...
2014: Analytical Chemistry Insights
journal
journal
41857
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.