journal
Journals Contact Lens & Anterior Eye : ...

Contact Lens & Anterior Eye : the Journal of the British Contact Lens Association

https://read.qxmd.com/read/38462405/central-and-peripheral-corneal-sagittal-height-in-keratoconus-and-healthy-eyes
#21
JOURNAL ARTICLE
Manel Larrosa, Joan Gispets, Núria Lupón, Genis Cardona, Anaïs Sempere
PURPOSE: To determine central and peripheral corneal sagittal height (z) values in keratoconus and healthy eyes with the Oculus Pentacam point-by-point data extraction software. METHODS: Forty eyes from patients with central or paracentral (4 mm) keratoconus (32.0 ± 12.5 years) and 40 eyes from healthy subjects (29.1 ± 7.9 years) were included. The Oculus Pentacam software was employed to determine z values referenced to a plane tangent to the corneal apex for five circles concentric with the centre of the pupil with diameters 4, 6, 8, 9 and 10...
March 9, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38462404/rethinking-contact-lens-aftercare
#22
EDITORIAL
Shehzad Naroo
No abstract text is available yet for this article.
March 9, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38443210/are-artificial-intelligence-chatbots-a-reliable-source-of-information-about-contact-lenses
#23
JOURNAL ARTICLE
Nery García-Porta, Megan Vaughan, Sofia Rendo-González, Ana I Gómez-Varela, Autumn O'Donnell, Joaquim de-Moura, Jorge Novo-Bujan, Marcos Ortega-Hortas
INTRODUCTION: Artificial Intelligence (AI) chatbots are able to explain complex concepts using plain language. The aim of this study was to assess the accuracy of three AI chatbots answering common questions related to contact lens (CL) wear. METHODS: Three open access AI chatbots were compared: Perplexity, Open Assistant and ChatGPT 3.5. Ten general CL questions were asked to all AI chatbots on the same day in two different countries, with the questions asked in Spanish from Spain and in English from the U...
March 4, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38443209/assessing-the-proficiency-of-artificial-intelligence-programs-in-the-diagnosis-and-treatment-of-cornea-conjunctiva-and-eyelid-diseases-and-exploring-the-advantages-of-each-other-benefits
#24
JOURNAL ARTICLE
Eyupcan Sensoy, Mehmet Citirik
PURPOSE: It was aimed to determine the knowledge level of ChatGPT, Bing, and Bard artificial intelligence programs related to corneal, conjunctival, and eyelid diseases and treatment modalities, to examine their reliability and superiority to each other. METHODS: Forty-one questions related to corneal, conjunctival, and eyelid diseases and treatment modalities were asked to the ChatGPT, Bing, and Bard chatbots. The answers to the questions were compared with the answer keys and grouped as correct or incorrect...
March 4, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38423868/evaluating-the-in-vitro-wettability-and-coefficient-of-friction-of-a-novel-and-contemporary-reusable-silicone-hydrogel-contact-lens-materials-using-an-in-vitro-blink-model
#25
JOURNAL ARTICLE
Chau-Minh Phan, Vivian Wy Chan, Elizabeth Drolle, Alex Hui, William Ngo, Susmita Bose, Amanda Shows, Shuang Liang, Vinay Sharma, Lakshman Subbaraman, Ying Zheng, Xinfeng Shi, James Wu, Lyndon Jones
PURPOSE: To evaluate the in vitro wettability and coefficient of friction of a novel amphiphilic polymeric surfactant (APS), poly(oxyethylene)-co-poly(oxybutylene) (PEO-PBO) releasing silicone hydrogel (SiHy) contact lens material (serafilcon A), compared to other reusable SiHy lens materials. METHODS: The release of fluorescently-labelled nitrobenzoxadiazole (NBD)-PEO-PBO was evaluated from serafilcon A over 7 days in a vial. The wettability and coefficient of friction of serafilcon A and three contemporary SiHy contact lens materials (senofilcon A; samfilcon A; comfilcon A) were evaluated using an in vitro blink model over their recommended wearing period; t = 0, 1, 7, 14 days for all lens types and t = 30 days for samfilcon A and comfilcon A (n = 4)...
February 29, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38403480/the-effect-of-the-back-optic-zone-diameter-on-the-treatment-zone-area-and-axial-elongation-in-orthokeratology
#26
JOURNAL ARTICLE
Wenzhi Ding, Dongdong Jiang, Yuyin Tian, Weicong Lu, Lin Shi, Rongyuan Ji, Chenpei Zhao, Lin Leng
PURPOSE: To investigate the influence of corneal parameters on the treatment zone area (TZA) after Corneal Refractive Therapy (CRT) with a 5.0-mm back optical zone diameter (BOZD) were worn and to compare changes in the axial length (AL) with traditional 6.0-mm BOZD lenses. METHODS: This retrospective study involved 146 subjects (7-12 years) who wore orthokeratology (ortho-K) lenses for one year: 86 subjects were treated with CRT 5.0-mm lenses, and 60 subjects were treated with CRT 6...
February 25, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38350814/influence-of-serial-intravitreal-injections-on-measures-of-dry-eye-a-systemic-review-and-meta-analysis
#27
REVIEW
Meng Gao, Fei Xia, Ping Wang, ZhenHua Feng, XinXin Wang
PURPOSE: The aim of this study was to evaluate the long-term effects of serial intravitreal injections (IVI) on measures of dry eye. METHODS: The PubMed, EMBASE, and Cochrane databases were searched according to the PROSPERO protocol (CRD42023455727). Studies evaluating the influence of serial IVI on the ocular surface compared with untreated fellow eyes were included. The measures of dry eye after IVI were used as outcome variables. The results are presented as mean difference (MD) with a corresponding 95% confidence interval (CI)...
February 12, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38342733/knowledge-and-compliance-with-contact-lens-care-a-population-based-study-at-a-referral-center-in-northeast-mexico
#28
JOURNAL ARTICLE
Eugenia M Ramos-Dávila, Raul E Ruiz-Lozano, Kathia Gutierrez-Juarez, Carlos Manuel Rusque-Lavalle, Patricio A Garza-Villarreal, Fredy Nacif-Lopéz, Yolanda Macias-Rodriguez
OBJECTIVE: Despite the increasing prevalence of contact lens (CL) wear, knowledge and compliance with proper care remain suboptimal. This study aims to assess the level of knowledge and compliance with lens care practices in patients attending a third-level institution in Northeast Mexico. METHODS: A cross-sectional study using a self-administered online survey was conducted. Patients at the Instituto Tecnolgico de Monterrey were invited to participate. The questionnaire consisted of three sections: demographic data and CL information, CL practices, and CL care knowledge...
February 10, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38342732/profile-of-contact-lens-prescribing-in-gcc-countries
#29
JOURNAL ARTICLE
Babu Noushad, Zoelfigar Mohamed, Gopi Suresh Vankudre, Jameel Rizwana Hussaindeen, Kalsoom Rani, Muzamil Elhaj, Nasser Alshamli
PURPOSE: This study aimed to report the pattern of contact lens prescribing from the Gulf Cooperation Council (GCC) countries. METHODS: Optometrists in the GCC region were contacted to participate in a web-based survey hosted on Qualtrics XM (Provo, Utah, USA). The survey methodology was adapted from the International Contact Lens Prescribing Consortium, and participants were asked to report their last five lens fits. It collected information on practitioner demographics (age, gender, nationality, qualification, country of practice, and number of years of experience), CL user demographics (age and gender) and on lens specific details such as lens type, lens design, lens material, replacement plan, and modality of lens wear...
February 10, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38341309/the-activity-of-antimicrobial-peptoids-against-multidrug-resistant-ocular-pathogens
#30
JOURNAL ARTICLE
Manjulatha Sara, Muhammad Yasir, Parthasarathi Kalaiselvan, Alex Hui, Rajesh Kuppusamy, Naresh Kumar, Sudip Chakraborty, Tsz Tin Yu, Edgar H H Wong, Natalia Molchanova, Håvard Jenssen, Jennifer S Lin, Annelise E Barron, Mark Willcox
BACKGROUND: Ocular infections caused by antibiotic-resistant pathogens can result in partial or complete vision loss. The development of pan-resistant microbial strains poses a significant challenge for clinicians as there are limited antimicrobial options available. Synthetic peptoids, which are sequence-specific oligo-N-substituted glycines, offer potential as alternative antimicrobial agents to target multidrug-resistant bacteria. METHODS: The antimicrobial activity of synthesised peptoids against multidrug-resistant (MDR) ocular pathogens was evaluated using the microbroth dilution method...
February 9, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38057197/effect-of-myopia-management-contact-lens-design-on-accommodative-microfluctuations-and-eye-movements-during-reading
#31
RANDOMIZED CONTROLLED TRIAL
Neema Ghorbani-Mojarrad, Muskaan Hussain, Aleksandra Mankowska, Edward Mallen, Matthew Cufflin
BACKGROUND: Soft contact lenses have been developed and licensed for reducing myopia progression. These lenses have different designs, such as extended depth of focus (EDOF) and dual focus (DF). In this prospective, double-masked, cross-over study, different lens designs were investigated to see whether these had impact on accommodative microfluctuations and eye movements during reading. METHODS: Participants were fitted with three lenses in a randomised order; a single vision (SV) design (Omafilcon A2; Proclear), a DF design (Omafilcon A2; MiSight), and an EDOF lens design (Etafilcon A; NaturalVue),...
February 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/37977905/orthokeratology-combined-with-spectacles-in-moderate-to-high-myopia-adolescents
#32
JOURNAL ARTICLE
Feifu Wang, Ge Wu, Xindi Xu, Haoran Wu, Yiyi Peng, Yiran Lin, Jun Jiang
PURPOSE: Wearing ortho-k lenses overnight may not fully correct their daytime refractory errors of adolescents with moderate to high myopia. There are three common ways to deal with the daytime residual refractive error (RRE): 1) wearing spectacles to correct the RRE; 2) wear ortho-k lenses during the daytime instead of overnight.; 3) not correcting the residual refractive error. According to previous laboratory studies, myopic peripheral refraction is associated with better myopic control...
February 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/37951738/platelet-rich-plasma-for-treating-dry-eye-disease-a-systematic-review-and-meta-analysis
#33
JOURNAL ARTICLE
Prince Kwaku Akowuah, Chukwuemeka Junior Obinwanne, Ebenezer Owusu, Sylvester Kyeremeh, Kwaku Bonsu, Lucy Akua Afriyie Karikari, Felicia Akyaa Akomeah, Ernest Kyei Nkansah, Emmanuel Kobia-Acquah
PURPOSE: Dry eye disease has public health and economic significance. Platelet-rich plasma is rich in anti-inflammatory agents and growth factors, both beneficial for ocular surface repair. This study aimed to conduct a systematic review and meta-analysis to summarize the benefits of platelet-rich plasma for treating dry eye disease and its adverse effects. METHODS: Prospective comparative studies using platelet-rich plasma as monotherapy for dry eye disease were included for efficacy assessment...
February 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38246852/assessment-of-dynamic-corneal-response-parameters-in-chinese-patients-of-different-ages-with-myopia-and-orthokeratology-lenses-using-the-corvis-st
#34
JOURNAL ARTICLE
Shuxian Zhang, Jinghua Liu, Juan Gao, Yarong Yan, Peng Hao, Xuan Li
OBJECTIVE: To investigate the effects of orthokeratology lenses (OK lenses) on corneal biomechanics in subjects of different ages. METHODS: Fifty subjects with mild to moderate myopia were categorized into three groups (Group I-III) based on their age. Corvis ST was used to collect dynamic corneal response parameters (DCRs) at different follow-up time points. Repeated measures analysis of variance combined with simple effect analysis was used to analyze the changes in DCRs in different groups during the follow-up period...
January 20, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38220498/clinical-outcomes-and-prognostic-factors-in-acanthamoeba-keratitis
#35
JOURNAL ARTICLE
Rodrigo Vilares-Morgado, Ana Margarida Ferreira, Pedro Marques-Couto, Carolina Madeira, Raúl Moreira, Luís Torrão, Pedro Neves-Cardoso, Ana Maria Cunha, Sandra Rebelo, João Pinheiro-Costa
PURPOSE: To report clinical findings and prognostic factors for visual and morphological outcomes in patients with Acanthamoeba keratitis (AK). METHODS: Single-center, retrospective, longitudinal study of 51 cases of AK diagnosed by real-time polymerase chain reaction (RT-PCR) between March 2010 and October 2022. The primary outcome was the final best corrected visual acuity (BCVA). Poor visual outcome was defined as a final BCVA ≥ 1 logMAR unit, while good visual outcome was defined as a final BCVA < 1 logMAR unit...
January 13, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38220497/different-efficacy-in-myopia-control-comparison-between-orthokeratology-and-defocus-incorporated-multiple-segment-lenses
#36
JOURNAL ARTICLE
Weicong Lu, Rongyuan Ji, Dongdong Jiang, Lin Shi, Wenzhi Ding, Yuyin Tian, Chenpei Zhao, Lin Leng
PURPOSE: To compare the efficiency of orthokeratology (OK) and defocus-incorporated multiple segment (DIMS) lenses in myopia control in children. METHODS: This prospective study involved 540 subjects (7-14 years) categorized into three groups: DIMS lenses (180 cases), OK lenses (180 cases), or single-vision spectacles (SVS) (180 cases). After a one-year follow-up, changes in axial length (AL) and differences among the groups were analyzed. The subjects were further divided into a low myopia degree subgroup (LM, -1...
January 13, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38216392/multifocal-contact-lens-success-predictability
#37
JOURNAL ARTICLE
Percy Lazon de la Jara, Anna Sulley, Pasquale Pepe, Karen Walsh, Michel Guillon
PURPOSE: The current multi-study analysis combined data from three studies to quantify the relationship between the initial reaction to soft multifocal contact lens (MFCL) design types at dispensing and evaluate the predictability of overall vision satisfaction (OVS) and intention to purchase (ITP) after 1 week of wear. METHOD: Three prospective studies tested MFCLs over 1-week of wear following the same protocol, using a range of potentially predictive ratings at dispensing, and both OVS and ITP at 1-week as an indicator acceptance level...
January 11, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38195312/bcla-presidential-address-2023-opportunities-for-growth-in-the-contact-lens-sector
#38
EDITORIAL
Rakesh Kapoor
No abstract text is available yet for this article.
January 8, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38195311/the-influence-of-eyelid-pressure-and-eye-contour-factors-on-rigid-corneal-contact-lens-fitting
#39
JOURNAL ARTICLE
Hongqing Ma, Meng Lin, Jian Zhao, Yijie Xu, Lijie Miao, Xueli Shao, Zhiqiang Xu, Jia Qu, Fan Lu, Liang Hu
PURPOSE: This study aimed to investigate the impact of eyelid pressure (ELP) and eye contour factors on rigid corneal contact lens fitting. METHODS: This prospective cross-sectional study involved 20 participants (one eye per person). Rigid corneal contact lenses with three different base curves were selected for each participant. The base curves were calculated according to the average keratometry value. The original value and its variations (+0.1 mm and - 0...
January 8, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
https://read.qxmd.com/read/38171997/settling-characteristics-of-scleral-lenses-in-chinese-adults-with-refractive-error
#40
JOURNAL ARTICLE
Ruzhi Deng, Bichi Chen, Feifu Wang, Li Tian, Zhiyang Lin, Kou Zhang, Jieli Mao, Maoyuan Yang, Jun Jiang
PURPOSE: To investigate the settling characteristics of a scleral lens in Chinese adults with refractive error and to provide guidance for its clinical application. METHODS: A total of 21 healthy Chinese adults (27.2 ± 4.1 years) with refractive error were enrolled in this study. The average spherical equivalent was -5.50 ± 2.92 D. Subjects were fitted with 15.6 mm diameter scleral lenses. The central post-lens tear thickness (PoLTT) was measured immediately after lens placement, 30, 60, 120, and 240 min after lens insertion at the dispensing visit and immediately after lens placement and 240 min after three months through optical coherence tomography...
January 2, 2024: Contact Lens & Anterior Eye: the Journal of the British Contact Lens Association
journal
journal
32839
2
3
Fetch more papers »
Fetching more papers... Fetching...
Remove bar
Read by QxMD icon Read
×

Save your favorite articles in one place with a free QxMD account.

×

Search Tips

Use Boolean operators: AND/OR

diabetic AND foot
diabetes OR diabetic

Exclude a word using the 'minus' sign

Virchow -triad

Use Parentheses

water AND (cup OR glass)

Add an asterisk (*) at end of a word to include word stems

Neuro* will search for Neurology, Neuroscientist, Neurological, and so on

Use quotes to search for an exact phrase

"primary prevention of cancer"
(heart or cardiac or cardio*) AND arrest -"American Heart Association"

We want to hear from doctors like you!

Take a second to answer a survey question.